• 제목/요약/키워드: Analog tester

검색결과 10건 처리시간 0.024초

디스플레이용 스위칭모드 전원장치의 단락 고장분석 검출기법 (Techniques to Diagnose Short-Circuit Faults in the Switching Mode Power Supply for Display)

  • 이재원;전태원
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1186-1192
    • /
    • 2016
  • This paper proposes techniques to diagnose short-circuit faults of both the diodes and power FET in switching mode power supply (SMPS) by using a simple analog tester. The diodes in full-bridge rectifier, power FET, switching transformer, and some sensors are modelled with resistor. The total resistance value measured at the input terminal of a SMPS is analyzed when the short-circuit faults of diodes in a full bridge rectifier or power FET are occurred. The short-circuit faults of one or two diodes in a full bridge rectifier, power FET, and both the diodes in a full bridge rectifier and power FET can be detected by a range of total resistance, which is measured by the analog tester. Through experiments, the theoretical analysis for total resistance under short-circuit faults can be verified.

LCD 구동 모듈 PCB의 자동 기능 검사를 위한 Emulated Vision Tester (Emulated Vision Tester for Automatic Functional Inspection of LCD Drive Module PCB)

  • 주영복;한찬호;박길흠;허경무
    • 전자공학회논문지SC
    • /
    • 제46권2호
    • /
    • pp.22-27
    • /
    • 2009
  • 본 논문에서는 LCD 구동 모듈 PCB의 기능 검사를 위한 자동 검사 시스템인 EVT (Emulated Vision Tester)를 제안하고 구현하였다. 기존의 대표적인 자동검사 방법으로는 전기적 검사나 영상기반 검사방식이 있으나 전기적 검사만으로는 Timing이 주요한 변수가 되는 LCD 장비에서는 검출할 수 없는 구동불량이 존재하며 영상기반 검사는 영상획득에 일관성이 결여되거나 Gray Scale의 구분이 불명확하여 검출결과의 재현성이 떨어진다. EVT 시스템은 Pattern Generator에서 인가된 입력 패턴 신호와 구동 모듈을 통한 후 출력되는 디지털 신호를 직접 비교하여 패턴을 검사하고 아날로그 신호 (전압, 저항, 파형)의 이상 여부도 신속 정확하게 검사할 수 있는 하드웨어적인 자동 검사 방법이다. 제안된 EVT 검사기는 높은 검출 신뢰도와 빠른 처리 속도 그리고 간결한 시스템 구성으로 원가 절감 및 전공정 검사 자동화의 실현을 가능케 하는 등 많은 장점을 가진다.

차세대 통합네트워크를 위한 MEGACO 프로토콜 호 처리 시험기 연구 (A Study on a Tester of the MEGACO Protocol Call Processing for the Next Generation Convergence Network)

  • 이규호;성길영
    • 한국정보통신학회논문지
    • /
    • 제11권12호
    • /
    • pp.2265-2270
    • /
    • 2007
  • 본 논문은 IETF와 ITU-T에서 공동으로 권고하는 미디어 게이트웨이 제어 프로토콜인 MEGACO/H.248 기반의 미디어 게이트웨이 컨트롤러와 액세스 게이트웨이의 호 처리 성능 및 기능시험 연구에 관한 내용이다. 기존 PSTN망에서 서비스되고 있는 음성 트래픽을 IP망으로 통합하는 차세대 통합네트워크의 핵심적인 구성요소로서 미디어 게이트웨이 컨트롤러와 액세스 게이트웨이의 호 처리 성능 및 기능을 시험하기 위한 효과적인 방법 및 시험 시스템 구조에 관한 연구로, 특히 시험 환경 구축을 위해 액세스 게이트웨이에 접속되는 다수의 아날로그 라인들에 대한 가상 에뮬레이션 기능과, 미디어 게이트웨이 컨트롤러와 액세스 게이트웨이 시험을 위해, 프로토콜의 상대역할을 에뮬레이션하는 시험기로 동작하는 효과적인 방안과 그 타당성을 논의한다.

멀티테스터를 이용한 3상유도전동기 고정자 권선의 극성 판별법에 관한 연구 (A study on how to discriminate the polarities of stator windings for 3 phase induction motors by using general purpose multi-testers)

  • 최순만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권9호
    • /
    • pp.1137-1140
    • /
    • 2014
  • 선박의 전동기에 고장이 발생하면 대개 육상에서 수리 후 본선에 다시 재설치 되고 있으나 연결 단자의 기호 표시가 지워지거나 분명치 않을 때는 결선과정에서 전동기 권선의 극성 구별이 어려워진다. 이로 인해 Y-${\delta}$ 기동의 전동기에서 한 권선의 극성을 반대로 잘못 연결하는 경우 전원 투입과 동시에 과다한 전류가 흐르면서 재차 2차 고장으로 이어질 위험이 있다. 이러한 문제와 관련하여 본 논문은 고정자의 1상 권선에 미소 직류전류를 흘릴 때 나머지 권선들에서 유도되는 과도 기전력의 특성을 토대로 아날로그 멀티테스터를 이용한 고정자 권선의 극성 판별법을 제시하고 관련 특성을 분석한다. 또한, 이 같은 방식을 실제 전동기에 적용하여 단계적인 측정과정을 통해 단자연결의 이상여부를 현장에서 용이하게 판별할 수 있는지를 확인해 보기로 한다.

신뢰성과 유지보수를 위한 원자로보호계통 주기시험 방법 개발 (RPS Periodic Testing Method for Reliability and Availability)

  • 박주현;이동영;이성진;송덕용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.84-86
    • /
    • 2005
  • The digital systems such as PLC or DCS have been applied to non-safety systems of nuclear power plants because of many difficulties in using analog systems. Nowadays, digital systems have been applied to safety systems of the plants such as reactor protection system. One of the main advantages of digital systems is applicability of automatic testing methods to the systems. The protection system requires high-reliability and high-availability because it shall minimize the propagation of abnormal or accident conditions of nuclear power plants. The calculation of reliability and availability of systems depends on the maintenance period of the system. In general, the maintenance period of the protection system is one-month in case of the manual test. However, the cycle of test can be shortened in several hours by using automatic periodic testing. The reliability and availability of the system is better when test period is shortened because the reliability and availability is inverse proportion to the test period. In this research, we developed the automatic periodic testing method for KNICS Reactor Protection System, which can test the system automatically without an operator or a tester. The automatic testing contained all functions of reaction protection systems from analog-to-digital conversion function of the bistable Processor to the coincident trip function of the coincident processor. By applying the automatic periodic testing to reaction system, the maintenance cost can be cut down and the reliability can be increased.

  • PDF

저전력형 반영구적인 갈바니 전원장치 개발 (The Development of the Low Power Consumption and Long Life Battery using a Galvanic Series)

  • 배정효;김대경;하태현;이현구;최상봉;정성환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3201-3204
    • /
    • 2000
  • In general, analog tester or strip chart recorder have been used to measure the corrosion potential of structures such as gas pipelines, oil pipelines, hot water pipelines, power cables etc. Recently, automatic digital data logger substitutes for these manual equipment because using these manual equipments are tedious and time consuming. However, digital data logger also has a shortcoming, that is, short measuring time because of the short lifetime of batteries. Therefore, we developed a long lifetime and low power loss battery taking advantage of galvanic series. In this paper, the results of development for power generator using two metals and DC/DC converter in order to obtain enough voltage for the operation of digital data logger. DC/DC converter operates with 0.5[V]. Its output voltage is 3.5[V] and output current is from 60[mAh] to 1,200[mAh].

  • PDF

MFC 기반 하이브리드 전자보오드 검사를 위한 규칙기반 솔루션 설계 (Design of a Rule-Based Solution Based on MFC for Inspection of the Hybrid Electronic Circuit Board)

  • 고윤석
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권9호
    • /
    • pp.531-538
    • /
    • 2005
  • This paper proposes an expert system which is able to enhance the accuracy and productivity by determining the test strategy based on heuristic rules for test of the hybrid electronic circuit board producted massively in production line. The test heuristic rules are obtained from test system designer, test experts and experimental results. The guarding method separating the tested device with circumference circuit of the device is adopted to enhance the accuracy of measurements in the test of analog devices. This guarding method can reduce the error occurring due to the voltage drop in both the signal input line and the measuring line by utilizing heuristic rules considering the device impedance and the parallel impedance. Also, PSA(Parallel Signature Analysis) technique Is applied for test of the digital devices and circuits. In the PSA technique, the real-time test of the high integrated device is possible by minimizing the test time forcing n bit output stream from the tested device to LFSR continuously. It is implemented in Visual C++ computer language for the purpose of the implementation of the inference engine using the dynamic memory allocation technique, the interface with the electronic circuit database and the hardware direct control. Finally, the effectiveness of the builded expert system is proved by simulating the several faults occurring in the mounting process the electronic devices to the surface of PCB for a typical hybrid electronic board and by identifying the results.

Effects of sling exercise and McKenzie exercise program on neck disability, pain, muscle strength and range of motion in chronic neck pain

  • Seo, Seung-Cheol;Choi, Jin-Young;Joo, Min-Young;Kim, Je-Hoon;Chang, Seul-Ki
    • Physical Therapy Rehabilitation Science
    • /
    • 제1권1호
    • /
    • pp.40-48
    • /
    • 2012
  • Objective: The aim of this study was to compare sling exercise group to McKenzie exercise group in patients with chronic neck pain. Design: Two group pretest-posttest design. Methods: Twenty subjects who have chronic neck pain were randomly divided into sling exercise group (n=10) and McKenzie exercise (n=10). Sling exercise group (n=10) received sling exercise for 30 minutes per day, twice a week over a 4 week period. And the other group were exercised McKenzie exercise (n=8) for 30 minutes per day, twice a week over a 4 week period. Neck disability index (NDI), Visual analog scale (VAS), algometer, digital manual muscle tester (MMT) and cervical muscle strength and cervical range of motion (ROM) are closely measured to identify the effect of sling exercise and McKenzie exercise. Results: For NDI, VAS, algometer on both trapezius, both rotation of cervical muscle strength, both lateral flexion of cervical muscle strength, cervical extension of ROM and both lateral flexion of ROM were significantly increased after intervention in sling exercise group (p<0.05), For VAS, algometer on both trapezius, left (Lt.) rotation of cervical muscle strength, Lt. lateral flexion of cervical muscle strength, cervical flexion and extension of ROM and Lt. lateral flexion of ROM were significantly increased after than before intervention in McKenzie exercise group (p<0.05). Conclusions: These study outcomes clearly support the notion that sling and McKenzie exercise improved pain, Muscle strength and ROM of patients with chronic neck pain. These results suggest that sling and McKenzie exercise program is suitable for chronic neck pain.

  • PDF

Effect of two types of muscle contraction training on muscle thickness, strength, and delayed onset of muscle soreness in persons with chronic stroke

  • Lim, Seung-yeop;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제7권4호
    • /
    • pp.154-163
    • /
    • 2018
  • Objective: The purpose of this study was to investigate the effects of eccentric contraction training (ECT) and concentric contraction training (CCT) on the muscle thickness (MT), muscle strength (MS) and delayed onset of muscle soreness (DOMS) of the lower extremities in persons with chronic stroke. Design: Randomized controlled trial. Methods: Thirty persons with chronic stroke were randomly assigned to the ECT or the CCT group. The ECT was performed in a specially designed system of eccentric contraction of both legs and, the CCT was performed using a traditional stepper system for concentric contraction of both legs. The training was performed for 30 min/times, 3 times/wk for 6 weeks. Rehabilitation ultrasound imaging was used to measure MT of the vastus medialis/lateralis (VL), and soleus (SOL), a digital muscle tester was used to measure MS, and a visual analog scale was used to assess DOMS. Results: In the ECT group, MT was significantly improved except for SOL resting (p<0.01). In the CCT group, the MT was significantly improved except for VL contraction (p<0.05). The MS was significantly improved in both groups, especially in the ECT group (p<0.01). In the ECT group, muscle soreness was highest in the first week after training but gradually decreased, and in the CCT group, it was highest in the second week of training but gradually decreased (p<0.01). Conclusions: ECT can improve lower limb MT, MS, and DOMS of chronic stroke survivors. Therefore, it is recommended that ECT be used in the rehabilitation of persons with chronic stroke.

MP3 장치용 플래시 메모리의 오류 검출을 위한 음원 비교 기법 (An Audio Comparison Technique for Verifying Flash Memories Mounted on MP3 Devices)

  • 김광중;박창현
    • 전자공학회논문지CI
    • /
    • 제47권5호
    • /
    • pp.41-49
    • /
    • 2010
  • 휴대용 정보기기와 엔터테인먼트기기 등의 사용이 대중화 되면서 플래쉬 메모리의 수요도 급격히 증가하였다. 일반적으로 플래시 메모리는 장착되는 장치에 따라 다양한 형태의 오류 패턴을 가지며, 메모리 생산자들은 최종적인 생산과정에서 실제 장착되는 기기와 동일한 환경에서 전기적/물리적 테스트를 수행한다. 이 과정을 메모리의 응용기기 실장 테스트라고 하며, 여기에서 사용되는 장비를 메모리 실장기라 한다. 현재 여러 가지 종류의 실장기들이 제작되어 메모리 생산 환경에서 사용되고 있으나 대부분이 검수자의 청각이나 시각 등의 감각에 의존하여 메모리의 오류를 판단하고 있다. MP3 실장기의 경우 음원의 재생 기능을 이용하여 메모리 오류를 판단하는데 적절한 자동 검수 기법이 존재하지 않아 검수자가 실장기에서 재생되는 음원을 직접 듣고 오류를 판단한다. 이런 과정은 실장환경의 자동화에 있어 큰 걸림돌이 되고 있으며 인력 활용 측면에서도 비효율적이다. 본 논문에서는 MP3 장치용 플래시 메모리의 효과적인 오류 검증을 위한 음원 비교 기법을 제안한다. 제안하는 방법은 원본 파일과 MP3 장치에서 재생되는 샘플값의 분산을 활용함으로써 메모리 오류 발생 여부를 판단한다.