• Title/Summary/Keyword: Analog tester

Search Result 10, Processing Time 0.025 seconds

Techniques to Diagnose Short-Circuit Faults in the Switching Mode Power Supply for Display (디스플레이용 스위칭모드 전원장치의 단락 고장분석 검출기법)

  • Lee, Jae-Won;Chun, Tae-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1186-1192
    • /
    • 2016
  • This paper proposes techniques to diagnose short-circuit faults of both the diodes and power FET in switching mode power supply (SMPS) by using a simple analog tester. The diodes in full-bridge rectifier, power FET, switching transformer, and some sensors are modelled with resistor. The total resistance value measured at the input terminal of a SMPS is analyzed when the short-circuit faults of diodes in a full bridge rectifier or power FET are occurred. The short-circuit faults of one or two diodes in a full bridge rectifier, power FET, and both the diodes in a full bridge rectifier and power FET can be detected by a range of total resistance, which is measured by the analog tester. Through experiments, the theoretical analysis for total resistance under short-circuit faults can be verified.

Emulated Vision Tester for Automatic Functional Inspection of LCD Drive Module PCB (LCD 구동 모듈 PCB의 자동 기능 검사를 위한 Emulated Vision Tester)

  • Joo, Young-Bok;Han, Chan-Ho;Park, Kil-Houm;Huh, Kyung-Moo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.2
    • /
    • pp.22-27
    • /
    • 2009
  • In this paper, an automatic functional inspection system EVT (Emulated Vision Tester) for LCD drive module PCB has been proposed and implemented. Typical automatic inspection system such as probing methods and vision-based systems are widely known and used, however, there exist undetectable defects due to critical timing factors which they may miss to catch from LCD equipments. Especially typical vision-based systems have inconsistency on acquisition of images so that distinction between gray scales can be difficult which results in low level of performance and reliability on the inspection results. The proposed EVT system is pure hardware solution. It directly compares pattern signals from a pattern generator to output signals from LCD drive module. It also inspects variety of analog signals such as voltage, resistance, wave forms and so forth. The EVT system not only shows high performance in terms of reliability and processing speed but reduces costs on inspection and maintenance. Also, full automation of entire production line can be realized when EVT is applied in in-line inspection processes.

A Study on a Tester of the MEGACO Protocol Call Processing for the Next Generation Convergence Network (차세대 통합네트워크를 위한 MEGACO 프로토콜 호 처리 시험기 연구)

  • Lee, Kyou-Ho;Sung, Kil-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.12
    • /
    • pp.2265-2270
    • /
    • 2007
  • This paper discusses a tester of functionality and call processing performance, based on the MEGACO/H.248 protocol that both IETF and ITU-T recommend as a media gateway control protocol, of both a media gateway controller and an access gateway which constitute a next generation convergence network. Effective methods, a functional architecture and implementation for such testification are provided. Especially included are not only a virtual emulation function of analog subscriber lines connecting to an access gateway, but also a tester emulated as a counter system of the protocol for the testifying a media gateway controller and an access gateway system.

A study on how to discriminate the polarities of stator windings for 3 phase induction motors by using general purpose multi-testers (멀티테스터를 이용한 3상유도전동기 고정자 권선의 극성 판별법에 관한 연구)

  • Choi, Soon-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1137-1140
    • /
    • 2014
  • Faulty electric motors onboard vessels with anomalies in windings or poor insulation are usually repaired at land based workshops and reinstalled in place by crew hands after receiving the repaired motors. Especially for 3 phase induction motors which need Y-${\delta}$ starters with 6 lead wires, it would happen that the polarities of stator windings cannot be well distinguished if the original tags of these wires are erased or not visible clearly, resulting in subsequent damage to the repaired motor due to extreme current flow when the power is given to the motor the stator windings of which are wrongly connected in the polarity. This study proposes an easy way to make correct connection in winding polarities without failures based on the electro-magnetically induced voltages on windings when a slight DC current is supplied to a winding coil by using an analog multi-tester. The proposed method is applied to actual motors and delves into the applicability for polarity discrimination through a few measurements onboard vessels.

RPS Periodic Testing Method for Reliability and Availability (신뢰성과 유지보수를 위한 원자로보호계통 주기시험 방법 개발)

  • Park, Joo-Hyun;Lee, Dong-Young;Lee, Seong-Jin;Song, Deok-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.84-86
    • /
    • 2005
  • The digital systems such as PLC or DCS have been applied to non-safety systems of nuclear power plants because of many difficulties in using analog systems. Nowadays, digital systems have been applied to safety systems of the plants such as reactor protection system. One of the main advantages of digital systems is applicability of automatic testing methods to the systems. The protection system requires high-reliability and high-availability because it shall minimize the propagation of abnormal or accident conditions of nuclear power plants. The calculation of reliability and availability of systems depends on the maintenance period of the system. In general, the maintenance period of the protection system is one-month in case of the manual test. However, the cycle of test can be shortened in several hours by using automatic periodic testing. The reliability and availability of the system is better when test period is shortened because the reliability and availability is inverse proportion to the test period. In this research, we developed the automatic periodic testing method for KNICS Reactor Protection System, which can test the system automatically without an operator or a tester. The automatic testing contained all functions of reaction protection systems from analog-to-digital conversion function of the bistable Processor to the coincident trip function of the coincident processor. By applying the automatic periodic testing to reaction system, the maintenance cost can be cut down and the reliability can be increased.

  • PDF

The Development of the Low Power Consumption and Long Life Battery using a Galvanic Series (저전력형 반영구적인 갈바니 전원장치 개발)

  • Bae, Jeong-Hyo;Kim, Dae-Kyeong;Ha, Tae-Hyun;Lee, Hyun-Goo;Choi, Sang-Bong;Jeong, Seong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3201-3204
    • /
    • 2000
  • In general, analog tester or strip chart recorder have been used to measure the corrosion potential of structures such as gas pipelines, oil pipelines, hot water pipelines, power cables etc. Recently, automatic digital data logger substitutes for these manual equipment because using these manual equipments are tedious and time consuming. However, digital data logger also has a shortcoming, that is, short measuring time because of the short lifetime of batteries. Therefore, we developed a long lifetime and low power loss battery taking advantage of galvanic series. In this paper, the results of development for power generator using two metals and DC/DC converter in order to obtain enough voltage for the operation of digital data logger. DC/DC converter operates with 0.5[V]. Its output voltage is 3.5[V] and output current is from 60[mAh] to 1,200[mAh].

  • PDF

Design of a Rule-Based Solution Based on MFC for Inspection of the Hybrid Electronic Circuit Board (MFC 기반 하이브리드 전자보오드 검사를 위한 규칙기반 솔루션 설계)

  • Ko Yun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.9
    • /
    • pp.531-538
    • /
    • 2005
  • This paper proposes an expert system which is able to enhance the accuracy and productivity by determining the test strategy based on heuristic rules for test of the hybrid electronic circuit board producted massively in production line. The test heuristic rules are obtained from test system designer, test experts and experimental results. The guarding method separating the tested device with circumference circuit of the device is adopted to enhance the accuracy of measurements in the test of analog devices. This guarding method can reduce the error occurring due to the voltage drop in both the signal input line and the measuring line by utilizing heuristic rules considering the device impedance and the parallel impedance. Also, PSA(Parallel Signature Analysis) technique Is applied for test of the digital devices and circuits. In the PSA technique, the real-time test of the high integrated device is possible by minimizing the test time forcing n bit output stream from the tested device to LFSR continuously. It is implemented in Visual C++ computer language for the purpose of the implementation of the inference engine using the dynamic memory allocation technique, the interface with the electronic circuit database and the hardware direct control. Finally, the effectiveness of the builded expert system is proved by simulating the several faults occurring in the mounting process the electronic devices to the surface of PCB for a typical hybrid electronic board and by identifying the results.

Effects of sling exercise and McKenzie exercise program on neck disability, pain, muscle strength and range of motion in chronic neck pain

  • Seo, Seung-Cheol;Choi, Jin-Young;Joo, Min-Young;Kim, Je-Hoon;Chang, Seul-Ki
    • Physical Therapy Rehabilitation Science
    • /
    • v.1 no.1
    • /
    • pp.40-48
    • /
    • 2012
  • Objective: The aim of this study was to compare sling exercise group to McKenzie exercise group in patients with chronic neck pain. Design: Two group pretest-posttest design. Methods: Twenty subjects who have chronic neck pain were randomly divided into sling exercise group (n=10) and McKenzie exercise (n=10). Sling exercise group (n=10) received sling exercise for 30 minutes per day, twice a week over a 4 week period. And the other group were exercised McKenzie exercise (n=8) for 30 minutes per day, twice a week over a 4 week period. Neck disability index (NDI), Visual analog scale (VAS), algometer, digital manual muscle tester (MMT) and cervical muscle strength and cervical range of motion (ROM) are closely measured to identify the effect of sling exercise and McKenzie exercise. Results: For NDI, VAS, algometer on both trapezius, both rotation of cervical muscle strength, both lateral flexion of cervical muscle strength, cervical extension of ROM and both lateral flexion of ROM were significantly increased after intervention in sling exercise group (p<0.05), For VAS, algometer on both trapezius, left (Lt.) rotation of cervical muscle strength, Lt. lateral flexion of cervical muscle strength, cervical flexion and extension of ROM and Lt. lateral flexion of ROM were significantly increased after than before intervention in McKenzie exercise group (p<0.05). Conclusions: These study outcomes clearly support the notion that sling and McKenzie exercise improved pain, Muscle strength and ROM of patients with chronic neck pain. These results suggest that sling and McKenzie exercise program is suitable for chronic neck pain.

  • PDF

Effect of two types of muscle contraction training on muscle thickness, strength, and delayed onset of muscle soreness in persons with chronic stroke

  • Lim, Seung-yeop;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.7 no.4
    • /
    • pp.154-163
    • /
    • 2018
  • Objective: The purpose of this study was to investigate the effects of eccentric contraction training (ECT) and concentric contraction training (CCT) on the muscle thickness (MT), muscle strength (MS) and delayed onset of muscle soreness (DOMS) of the lower extremities in persons with chronic stroke. Design: Randomized controlled trial. Methods: Thirty persons with chronic stroke were randomly assigned to the ECT or the CCT group. The ECT was performed in a specially designed system of eccentric contraction of both legs and, the CCT was performed using a traditional stepper system for concentric contraction of both legs. The training was performed for 30 min/times, 3 times/wk for 6 weeks. Rehabilitation ultrasound imaging was used to measure MT of the vastus medialis/lateralis (VL), and soleus (SOL), a digital muscle tester was used to measure MS, and a visual analog scale was used to assess DOMS. Results: In the ECT group, MT was significantly improved except for SOL resting (p<0.01). In the CCT group, the MT was significantly improved except for VL contraction (p<0.05). The MS was significantly improved in both groups, especially in the ECT group (p<0.01). In the ECT group, muscle soreness was highest in the first week after training but gradually decreased, and in the CCT group, it was highest in the second week of training but gradually decreased (p<0.01). Conclusions: ECT can improve lower limb MT, MS, and DOMS of chronic stroke survivors. Therefore, it is recommended that ECT be used in the rehabilitation of persons with chronic stroke.

An Audio Comparison Technique for Verifying Flash Memories Mounted on MP3 Devices (MP3 장치용 플래시 메모리의 오류 검출을 위한 음원 비교 기법)

  • Kim, Kwang-Jung;Park, Chang-Hyeon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.47 no.5
    • /
    • pp.41-49
    • /
    • 2010
  • Being popularized the use of portable entertainment/information devices, the demand on flash memory has been also increased radically. In general, flash memory reveals various error patterns by the devices it is mounted, and thus the memory makers are trying to minimize error ratio in the final process through not only the electric test but also the data integrity test under the same condition as real application devices. This process is called an application-level memory test. Though currently various flash memory testing devices have been used in the production lines, most of the works related to memory test depend on the sensual abilities of human testers. In case of testing the flash memory for MP3 devices, the human testers are checking if the memory has some errors by hearing the audio played on the memory testing device. The memory testing process like this has become a bottleneck in the flash memory production line. In this paper, we propose an audio comparison technique to support the efficient flash memory test for MP3 devices. The technique proposed in this paper compares the variance change rate between the source binary file and the decoded analog signal and checks automatically if the memory errors are occurred or not.