• Title/Summary/Keyword: Air discharge

Search Result 1,009, Processing Time 0.025 seconds

A Study on the Electrochemical Performance of Fe-V Chloric/Sulfuric Mixed Acid Redox Flow Battery Depending on Electrode Activation Temperature (Fe-V Chloric/Sulfuric Mixed Acid 레독스흐름전지 전극의 활성화 온도에 따른 전기화학적 성능 고찰)

  • Lee, Han Eol;Kim, Dae Eop;Kim, Cheol Joong;Kim, Taekeun
    • Applied Chemistry for Engineering
    • /
    • v.31 no.6
    • /
    • pp.639-645
    • /
    • 2020
  • Among the components of redox flow battery (RFB), the electrode serves as a diffusion layer of an electrolyte and a path for electrons and also is a major component that directly affects the RFB performance. In this paper, chloric/sulfuric mixed acidwas used as a supporting electrolyte in RFB system with Fe2+/Fe3+ and V2+/V3+ as redox couple. The optimum electrode and activation temperature were suggested by comparing the capacity, coulombic efficiency and energy efficiency according to the electrode type and activation temperature. In the RFB single cell evaluation using 5 types of carbon electrodes used in the experiments, all of them showed close to the theoretical capacity to retain the reliability of the evaluation results. GFD4EA showed relatively excellent energy efficiency and charge/discharge capacity. In order to investigate the electrochemical performance according to the activation temperature, GFD4EA electrode was activated by heat treatment at different temperatures of 400, 450, 500, 600 and 700 ℃ under an air atmosphere. Changes in physical properties before and after the activation were observed using electrode mass retention, scanning electron microscope (SEM), XPS analysis, and electrochemical performance was compared by conducting RFB single evaluation using electrodes activated at each temperature given above.

Physical and Chemical Properties of Atomizing EFOS as Fine Aggregate for Concrete (아토마이징 전기로 산화슬래그 잔골재의 물리·화학적 특성)

  • Beom-Soo Kim;Sun-Mi Choi;Sang-Chul Shin;Sun-Gyu Park;Jin-Man Kim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.1
    • /
    • pp.70-78
    • /
    • 2023
  • Blast furnace slag, a by-product of the steel industry, is mostly recycled as concrete admixture, but electric arc furnace slag has not been recycled to date. In particular, since electric arc furnace slag partially contains free lime (free-CaO) in the discharge, it is necessary to review this in order to recycle f or construction materials. Recently an atomizing process which is a method of rapidly cooling electric arc furnace slag has been developed and applied. Therefore, in order to use the fine aggregate of oxidized slag from electric furnace restored by this method as an aggregate for concrete, physical damage and chemical reviewing are required. In this study, a physical and chemical review was conducted on the fine aggregate of Electric Arc Furnace Oxidizing Slag (EFOS) as a by-product of the steel manufacturing process with atomizing process. In this experimental study, EFOS was experimentally examined about whether it can be used as concrete fine aggregate. Also, we intend to provide basic data for the future use of the EFOS fine aggregate. As a result of the experimental study, it was found that the fine aggregate of the EFOS satisfied the quality standards of the fine aggregate for concrete in most items specified by Korean Standard.

Thermal Effluent Effects of Domestic Sewage and Industrial Wastewater on the Water Quality of Three Small Streams (Eung, Chiljang and Buso) during the Winter Season, Korea (동계 저온기의 소하천 수질에 미치는 하·폐수의 온배수 영향)

  • Soon-Jin, Hwang;Jeon, Gyeonghye;Eum, Hyun Soo;Kim, Nan-Young;Shin, Jae-Ki
    • Korean Journal of Ecology and Environment
    • /
    • v.50 no.2
    • /
    • pp.238-253
    • /
    • 2017
  • The sewage and wastewater (SAW) are a well-known major source of eutrophication and greentide in freshwaters and also a potential source of thermal pollution; however, there were few approaches to thermal effluent of SAW in Korea. This study was performed to understand the behavioral dynamics of the thermal effluents and their effects on the water quality of the connected streams during winter season, considering domestic sewage, industrial wastewater and hot spring wastewater from December 2015 to February 2016. Sampling stations were selected the upstream, the outlet of SAW, and the downstream in each connected stream, and the water temperature change was monitored toward the downstream from the discharging point of SAW. The temperature effect and its range of SAW on the stream were dependent not only on the effluent temperature and quantity but also on the local air temperature, water temperature and stream discharge. The SAW effects on the stream water temperature were observed with temperature increase by $2.1{\sim}5.8^{\circ}C$ in the range of 1.0 to 5.5 km downstream. Temperature effect was the greatest in the hot spring wastewater despite of small amount of effluent. The SAW was not only related to temperature but also to the increase of organic matter and nutrients in the connected stream. The industrial wastewater effluent was discharged with high concentration of nitrogen, while the hot spring wastewater was high in both phosphorus and nitrogen. The difference between these cases was due to with and without chemical T-P treatment in the industrial and the hot spring wastewater, respectively. The chlorophyll-a content of the attached algae was high at the outlet of SAW and the downstream reach, mostly in eutrophic level. These ecological results were presumably due to the high water temperature and phosphorus concentration in the stream brought by the thermal effluents of SAW. These results suggest that high temperature of the SAW needs to be emphasized when evaluating its effects on the stream water quality (water temperature, fertility) through a systematized spatial and temporal investigation.

Effects of Calcinations Temperature on the Electrochemical Properties of Li[Ni0.6Co0.2Mn0.2]O2 Lithium-ion Cathode Materials (리튬 이차전지용 양극활물질 Li[Ni0.6Co0.2Mn0.2]O2의 소성 온도가 전기화학적 특성에 미치는 영향)

  • Yoo, Gi-Won;Jeon, Hyo-Jin;Son, Jong-Tae
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.2
    • /
    • pp.59-64
    • /
    • 2013
  • Using $Na_2CO_3$ and $MeSO_4$ (Me = Ni, Co and Mn) as starting materials, the precursor of $[Ni_{0.6}Co_{0.2}Mn_{0.2}]CO_3$ has been synthesized by carbonate co-precipitation. The precursor was mixed with $Li_2CO_3$, and calcined at 750, 850, and$950^{\circ}C$ in air. Effect of calcinations temperature on characteristics of $Li[Ni_{0.6}Co_{0.2}Mn_{0.2}]O_2$ cathode materials was investigated. The structure and characteristics of $Li[Ni_{0.6}Co_{0.2}Mn_{0.2}]O_2$ were determined by X-ray diffraction (XRD), Scanning electron microscopy (SEM) and electrochemical measurements. The X-ray diffraction (XRD) results show that the intensity ratio of $I_{(003)}/I_{(104)}$ increased and the R-factor ratio decreased with the increase of calcinations temperature. And Scanning electron microscopy (SEM) result show that the primary particle size increased. Especially, the $Li[Ni_{0.6}Co_{0.2}Mn_{0.2}]O_2$ calcined at $950^{\circ}C$ for 24 H shows excellent electrochemical performances with reversible specific capacity of $165.3mAhg^{-1}$ [cut-off voltage 2.5~4.3 V, 0.1 C($17mAhg^{-1}$)] and good capacity retention of 95.4% after 50th charge/discharge cycles[cut-off voltage 2.5~4.3 V, 1 C($170mAhg^{-1}$)].

Quality characteristics of rice noodles treated with cold plasma (저온 플라즈마 처리한 쌀국수의 품질 특성)

  • Kim, Hyun-Joo;Lee, Byong Won;Baek, Ki Ho;Jo, Cheorun;Kim, Jae-Kyung;Lee, Jin Young;Lee, Yu-Young;Kim, Min Young;Kim, Mi Hyang;Lee, Byoungkyu
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.5
    • /
    • pp.560-563
    • /
    • 2020
  • Cold plasma has been applied to improve quality of food product; however, studies on its effects on microbial and physicochemical qualities of rice noodles are rarely conducted. In this study, changes in the quality characteristics of rice noodles treated by cold plasma were determined. Cold plasma was generated in a square-shaped plastic container (250 W, 15 kHz, ambient air), and dielectric barrier discharge plasma treatments were applied to rice noodle samples for 0, 10, or 20 min. Rice noodles inoculated with either Bacillus cereus or Escherichia coli O157:H7 were subjected to plasma treatment for 20 min, and the approximate bacterial count reduction were 4.10 and 2.75 log CFU/g, respectively. The Hunter color values of the sample were increased after cold plasma treatment. Peroxide values and thiobarbituric acid reactive substance (TBARS) were increased with an increase in cold plasma treatment time. Futhermore, lipid oxidation was enhanced. Although further studies are warranted to evaluate changes in chemical qualities, such as lipid oxidation of rice noodles, induced by cold plasma, the results suggest that cold plasma can improve the microbial and physical qualities of rice noodles.

Effect of Atmospheric Pressure Plasma on the Quality of Commercially Available Sunsik (대기압 플라즈마가 선식의 품질 특성에 미치는 영향)

  • Kim, Hyun-Joo;Woo, Koan Sik;Jo, Cheorun;Lee, Seuk Ki;Park, Hye Young;Sim, Eun-Yeong;Won, Yong-Jae;Lee, Sang-Bok;Oh, Sea-Kwan
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.5
    • /
    • pp.375-379
    • /
    • 2016
  • Atmospheric pressure plasma (APP) was applied to examine microbial safety and qualities of commercial Sunsik. APP was generated in a square-shaped plastic container (250 W, 15 kHz, ambient air) and dielectric barrier discharge plasma treatment was applied for periods of 0, 5, 10, and 20 minutes. The total aerobic bacterial count in the control was 4.44 log CFU/g. Under plasma treatment for 20 minutes, Sunsik samples inoculated with Bacillus cereus, B. subtilis, and Escherichia coli O157:H7 resulted in a reduction of bacterial counts by approximately 2.20, 2.22, and 2.52 log CFU/g, respectively. The pH of the sample was found to decrease after APP treatment. Although hunter color $L^*$ of Sunsik increased, $a^*$ and $b^*$ value decreased as a result of APP. Increasing the APP time also enhanced the peroxide value. Further, sensory evaluation revealed that APP decreased color, flavor, taste and overall acceptability. The results of this study indicated that APP treatment improved the microbial quality of Sunsik, although further studies should be conducted to reduce the deterioration of sensory quality induced by APP.

Chemical Properties and Nutrient Loadings of Rainwater during Farming Season (영농기 강우의 화학적 특성 및 부하량 평가)

  • Ko, Byong-Gu;Kim, Min-Kyeong;Lee, Jong-Sik;Kim, Gun-Yeob;Park, Seong-Jin;Kwon, Soon-Ik;Jung, Goo-Buk;Lee, Deog-Bae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.5
    • /
    • pp.578-583
    • /
    • 2010
  • Acid rain and its problem to environment such as acid precipitation and environmental problems related to the air pollution in East Asia has been emerging. To evaluate the acidity and chemical characteristics of rainwater precipitated in western Korea, Suwon and Taean, its pH and ion concentrations were investigated during farming season (April to November) in 2009. Also, ion composition and cation-affected neutralization were determined to evaluate the contribution of cations on the acidity of rainwater. Ion and electrical conductivity between the measured and the estimated showed high correlation. The $Na^+$ in rainwater was the main cation followed by ${NH_4}^+>Ca^{2+}>H^+>Mg^{2+}>K^+$. Sum of $Na^+$ and ${NH_4}^+$ contents was over 65% of total cations contents. In the case of anions, the concentration was in order of ${SO_4}^{2-}>{NO_3}^->Cl^-$. The ${SO_4}^{2-}$ among anions in rainwater composed about 61%, which showed on average 130.2 ${\mu}eq\;L^{-1}$ and 121.3 ${\mu}eq\;L^{-1}$ during monitoring at Suwon and Taean, respectively. Also, 89.6 and 88.6% of soluble sulfate in rainwater at Suwon and Taean area was NSS-${SO_4}^{2-}$ (Non-Sea Salt sulfate). Especially, ${NH_4}^+$ and $Ca^{2+}$ contributed greatly in neutralizing the acid rain in dry season. Total nitrogen content flowed into soil from rain was around 1~2 kg $ha^{-1}$ in each month, but in July at Suwon, it reached 6 kg $ha^{-1}$ due to heavy rain (over 7.3 mm).

A Study on Process Optimization for CSOs Application of Horizontal Flow Filtration Technology (수평흐름식 여과기술의 CSOs 적용을 위한 공정 최적화 연구)

  • Kim, Jae-Hak;Yang, Jeong-Ha;Lee, Young-Shin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.56-63
    • /
    • 2018
  • The management of Combined Sewer Overflows(CSOs) and Separated Sewer Overflows(SSOs) discharge directly to the effluent system in an untreated state, which occurs when the facility capacity is exceeded due to heavy rain, has become an important issue in recent years as the heavy rain becomes a regular phenomenon. Despite the continuous development of filtration technology, targeting densely populated urban areas, CSOs are rarely applied. Therefore, this study was carried out to optimize the process to apply CSOs in a pilot-scale horizontal flow filtration system with a rope-type synthetic fiber. The research was carried out in two steps: a preliminary study using artificial samples and a field study using sewage. In the preliminary study using an artificial sample, head loss of the filter media itself was analyzed to be approximately 1.1cm, and the head loss was increased by approximately 0.1cm as the linear velocity was increased by 10m/hr. In addition, the SS removal efficiency was stable at 81.4%, the filtration duration was maintained for more than 6 hours, and the average recovery rate of 98% was obtained by air backwashing only. In the on-site evaluation using sewage, the filtration duration was approximately 2 hours and the average removal efficiency of 83.9% was obtained when belt screen (over 450 mesh) was applied as a pre-treatment process to prevent the premature clogging of filter media. To apply the filtration process to CSOs and SSOs, it was concluded that the combination with the pre-treatment process was important to reinforce the hydraulic dimension for the stable maintain of operation period, rather than efficiency. Compared to the dry season, the quality of incoming sewage was lower in the rainy season, which was attributed to the characteristics of the drainage area with higher sanitary sewerage. In addition, the difference in removal efficiency according to the influent quality of the wet season and dry season was small.

Sputtering Yield and Secondary Electron Emission Coefficient(${\gamma}$) of the MgO, $MgAl_2O_4$ and $MgAl_2O_4/MgO$ Thin Film Grown on the Cu Substrate by Using the Focused Ion Beam (Cu 기판위에 성장한 MgO, $MgAl_2O_4$$MgAl_2O_4/MgO$ 박막의 집속이온빔을 이용한 스퍼터링수율 측정과 이차전자방출계수 측정)

  • Jung K.W.;Lee H.J.;Jung W.H.;Oh H.J.;Park C.W.;Choi E.H.;Seo Y.H.;Kang S.O.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.395-403
    • /
    • 2006
  • It is known that $MgAl_2O_4$ has higher resistance to moisture than MgO, in humid ambient MgO is chemically unstable. It reacts very easily with moisture in the air. In this study, the characteristic of $MgAl_2O_4$ and $MgAl_2O_4/MgO$ layers as dielectric protection layers for AC- PDP (Plasma Display Panel) have been investigated and analysed in comparison for conventional MgO layers. MgO and $MgAl_2O_4$ films both with a thickness of $1000\AA$ and $MgAl_2O_4/MgO$ film with a thickness of $200/800\AA$ were grown on the Cu substrates using the electron beam evaporation. $1000\AA$ thick aluminium layers were deposited on the protective layers in order to avoid the charging effect of $Ga^+$ ion beam while the focused ion beam(FIB) is being used. We obtained sputtering yieds for the MgO, $MgAl_2O_4$ and $MgAl_2O_4/MgO$ films using the FIB system. $MgAl_2O_4/MgO$ protective layers have been found th show $24{\sim}30%$ lower sputtering yield values from 0.244 up to 0.357 than MgO layers with the values from 0.364 up to 0.449 for irradiated $Ga^+$ ion beam with energies ranged from 10 kV to 14 kV. And $MgAl_2O_4$ layers have been found to show lowest sputtering yield values from 0.88 up to 0.109. Secondary electron emission coefficient(g) using the ${\gamma}$- FIB. $MgAl_2O_4/MgO$ and MgO have been found to have similar g values from 0.09 up to 0.12 for indicated $Ne^+$ ion with energies ranged from 50 V to 200 V. Observed images for the surfaces of MgO and $MgAl_2O_4/MgO$ protective layers, after discharge degradation process for 72 hours by SEM and AFM. It is found that $MgAl_2O_4/MgO$ protective layer has superior hardness and degradation resistance properties to MgO protective layer.

Treatment of Animal Wastewater Using Woodchip Trickling Filter System and Physical and Microbial Characteristics of Wood Chip Media (목편살수여상조를 이용한 축산뇨오수 처리와 목편여재의 물성 및 부착미생물 특성)

  • Ryoo, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.17 no.2
    • /
    • pp.71-80
    • /
    • 2011
  • Trickling filter has been extensively studied for the domestic wastewater treatment especially for the small scale plants in rural area. The purpose of this research is to survey the physical and microbial characteristics of wood chip media and the removal efficiency of animal wastewater using wood chip trickling filter system. The trickling filtration system comprises a filtration bed packed with wood chip media having a particle dia. of 5~7cm. The method comprises natural air from the bottom of the bed. The system also comprises a control mechanism including a time a constant discharge pump for controlling supply of the wastewater into the bed. The following conclusions were obtained from the results of this research. 1. The specific surface area of wood chip was 0.4123 $m^2$/g, pore volume was 0.0947 $cm^3$/g, density was 0.49 g/$cm^3$. It has forms of parallelogram and oblong which have numerous small pore space. This wood chip has been good condition for microorganism's habitat, having very larger specific surface area by complex the three dimension structure of cellulose at wood's major ingredients. 2. The total counts of in attached aerobic microbes were ranged from $10^6$ to $10^8$ CFU/g, and anaerobes microbial numbers were from $10^4$ to $10^7$. The aerobic microbial numbers appeared to be much more than those of anaerobic microbial numbers. 3. The average efficiency of $BOD_5$ and CODcr were 74.5% and 51.5%, respectively. The removal efficiency of T-N and T-P were 61.4%, 56.2%, respectively. But SS removal levels remain 19.3%.