• 제목/요약/키워드: Active neutral-point-clamped

검색결과 42건 처리시간 0.019초

Active NPC 인버터의 모델링 및 성능 분석 (Performance Analysis of Active Neutral-Point-Clamped Inverter Systems)

  • 박흥석;이교범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.171-172
    • /
    • 2018
  • 본 논문에서는 NPC (Neutral-Point-Clamped) 인버터와 ANPC (Active Neutral-Point-Clamped) 인버터의 특성과 성능을 비교 분석한다. ANPC 인버터는 기존의 NPC 인버터와 비교하여 스위칭 부하를 분산시켜 발열의 불균형을 해소하고 소자 수명을 증가시킨다. 기존의 NPC 인버터 시스템과 ANPC 인버터에 대하여 이론적인 특징과 성능을 분석하고 모델링과 시뮬레이션을 통하여 비교 분석한다.

  • PDF

Active Voltage-balancing Control Methods for the Floating Capacitors and DC-link Capacitors of Five-level Active Neutral-Point-Clamped Converter

  • Li, Junjie;Jiang, Jianguo
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.653-663
    • /
    • 2017
  • Multilevel active neutral-point-clamped (ANPC) converter combines the advantages of three-level ANPC converter and multilevel flying capacitor (FC) converter. However, multilevel ANPC converter often suffers from capacitor voltage balancing problems. In order to solve the capacitor voltage balancing problems for five-level ANPC converter, phase-shifted pulse width modulation (PS-PWM) is used, which generally provides natural voltage balancing ability. However, the natural voltage balancing ability depends on the load conditions and converter parameters. In order to eliminate voltage deviations under steady-state and dynamic conditions, the active voltage-balancing control (AVBC) methods of floating capacitors and dc-link capacitors based on PS-PWM are proposed. First, the neutral-point current is regulated to balance the neutral-point voltage by injecting zero-sequence voltage. After that, the duty cycles of the redundant switch combinations are adjusted to balance the floating-capacitor voltages by introducing moderating variables for each of the phases. Finally, the effectiveness of the proposed AVBC methods is verified by experimental results.

A New Direct Power Control Strategy for NPC Three-Level Voltage Source Rectifiers Using a Novel Vector Influence Table Method

  • Xia, Chang-Liang;Xu, Zhe;Zhao, Jia-Xin
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.106-115
    • /
    • 2015
  • This paper proposes a novel direct power control (DPC) strategy for neutral-point-clamped (NPC) three-level rectifiers, to directly control the active power, the reactive power and the neutral point potential of the rectifiers by referring to three pre-calculated vector influence tables and minimizing an objective function. In the three vector influence tables, the influences of different voltage vectors on the active power, the reactive power and the neutral-point potential are shown explicitly. A conceptual description and control algorithm of the proposed controller are presented in this paper. Then, numerical simulations and experiments are carried out to validate the proposed method. Both the simulation and experimental results show that good performances during both the steady-state and transient operating conditions are achieved. As a result, the proposed strategy has been proven to be effective for NPC three-level rectifiers.

Active NPC를 적용한 계통연계형 해상 풍력 발전용 전력변환 시스템 (Grid-Connected Off-Shore Wind Power System Using 3-Level ANPC VSC (Active Neutral-Point-Clamped Voltage Source Converter))

  • 홍석진;신수철;이희준;최치환;원충연;김학성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.249-250
    • /
    • 2012
  • 해상 풍력 발전은 가장 유망한 재생 에너지원의 하나이며, 육상 풍력 발전보다 풍력이 강력하고 일정하여 장시간 고출력 발생이 가능하다. 또한 소음, 공간적 한계, 경관훼손 등 기존 육상 풍력 발전의 단점을 보완하고 초대형 단지조성이 가능한 장점이 있다. 초대형 해상풍력단지에는 일반적으로 MW급의 해상풍력발전기가 사용된다. 본 논문에서는 MW급의 해상 풍력발전기에 ANPC(Active Neutral-Point-Clamped) Multi-Level VSC(Voltage Source Converter)를 적용하여 Back-to-Back으로 구성한 시스템을 제안하고 계통연계형 풍력 발전 시스템을 모의한 시뮬레이션을 통하여 제안된 시스템의 성능을 검증한다.

  • PDF

계통 연계형 Hybrid Active NPC 인버터의 SiC MOSFET 오버슈트 전압 저감 (Reducing Overshoot Voltage of SiC MOSFET in Grid-Connected Hybrid Active NPC Inverters)

  • 이덕호;김예지;김석민;이교범
    • 전력전자학회논문지
    • /
    • 제24권6호
    • /
    • pp.459-462
    • /
    • 2019
  • This work presents methods for reducing overshoot voltages across the drain-source of silicon carbide (SiC) MOSFETs in grid-connected hybrid active neutral-point-clamped (ANPC) inverters. Compared with 3-level NPC-type inverter, the hybrid ANPC inverter can realize the high efficiency. However, SiC MOSFETs conduct its switching operation at high frequencies, which cause high overshoot voltages in such devices. These overshoot voltages should be reduced because they may damage switching devices and result in electromagnetic interference (EMI). Two major strategies are used to reduce the overshoot voltages, namely, adjusting the gate resistor and using a snubber capacitor. In this paper, advantages and disadvantages of these methods will be discussed. The effectiveness of these strategies is verified by experimental results.

Three-Level NPC-Based Dual Active Bridge Converter의 도통손실 절감을 위한 새로운 스위칭 방법 (A Control Method to Improve Power Conversion Efficiency of Three-level NPC-Based Dual Active Bridge Converter)

  • 이준영;최현준;김주용;정지훈
    • 전력전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.150-158
    • /
    • 2017
  • This study proposes a new pulse-width modulation switching pattern for the low conduction loss of a three-level neutral point clamped (NPC)-based dual-active bridge (DAB) converter. The operational principle for a bidirectional power conversion is a phase-shift modulation. The conventional switching method of the three-level NPC-based DAB converter shows a symmetric switching pattern. This method has a disadvantage of high root-mean-square (RMS) value of the coupling inductor current, which leads to high conduction loss. The proposed switching method shows an asymmetrical pattern, which can reduce the RMS value of the inductor current with lower conduction loss than that of the conventional method. The performance of the proposed asymmetrical switching method is theoretically analyzed and practically verified using simulation and experiment.

HF/LF 변조를 적용한 Active NPC 인버터의 개방 고장 허용 제어 (Open Switch Fault Tolerance Control of Active NPC Inverters With HF/LF Modulation)

  • 정원석;김예지;김석민;이교범
    • 전기전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.170-177
    • /
    • 2020
  • 본 논문은 HF/LF 변조 방법을 적용한 ANPC (active neutral point clamped) 인버터의 스위치 개방 고장에 대응하기 위한 허용 제어 방법을 제안한다. 기존 Si 기반 인버터에 비해 SiC MOSFET과 Si IGBT로 구성된 ANPC 인버터는 시스템의 효율이 높고 출력 품질이 우수하다. HF/LF 변조는 커뮤테이션 루프를 줄일 수 있어 MW 급 대용량 인버터를 위해 사용되는 변조 기법이다. MW 급 인버터의 스위치 개방 고장은 부하에 심각한 손상을 입히며, 인버터가 동작을 멈출 경우 막대한 경제적 손실을 야기한다. 제안하는 스위치 개방 고장의 허용 제어 기술은 ANPC 인버터의 지속적인 운전을 가능하게 하며 신뢰성을 향상 시킨다. 제안하는 기법의 성능은 시뮬레이션 결과를 통해 검증한다.

Common-Mode Voltage Elimination for Medium-Voltage Three-Level NPC Inverters Based on an Auxiliary Circuit

  • Le, Quoc Anh;Lee, Sangmin;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2076-2084
    • /
    • 2016
  • In this paper, a novel scheme to eliminate common-mode voltage (CMV) is proposed for three-level neutral-point clamped (NPC) inverters. In the proposed scheme, a low-power full-bridge converter is utilized to produce compensatory voltage for CMV, which is injected into an NPC inverter through a single-phase four-winding transformer. With the proposed circuit, the power range for applications is not limited, and the maximum modulation index of the inverter is not reduced. These features are suitable for high-power medium-voltage machine drives. The effectiveness of the proposed method is verified by simulation and experimental results.

Subsection Synchronous Current Harmonic Minimum Pulse Width Modulation for ANPC-5L Inverter

  • Feng, Jiuyi;Song, Wenxiang;Xu, Yuan;Wang, Fei
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1872-1882
    • /
    • 2017
  • Medium voltage drive systems driven by high-power multi-level inverters operating at low switching frequency can reduce the switching losses of the power device and increase the output power. Employing subsection synchronous current harmonic minimum pulse width modulation (CHMPWM) technique can maintain the total harmonic distortion of current at a very low level. It can also reduce the losses of the system, improve the system control performance and increase the efficiency of DC-link voltage accordingly. This paper proposes a subsection synchronous CHMPWM approach of active neutral point clamped five-level (ANPC-5L) inverter under low switching frequency operation. The subsection synchronous scheme is obtained by theoretical calculation based on the allowed maximum switching frequency. The genetic algorithm (GA) is adopted to get the high-precision initial values. So the expected switching angles can be achieved with the help of sequential quadratic programming (SQP) algorithm. The selection principle of multiple sets of the switching angles is also presented. Finally, the validity of the theoretical analysis and the superiority of the CHMPWM are verified through both the simulation results and experimental results.

Switching Voltage Modeling and PWM Control in Multilevel Neutral-Point-Clamped Inverter under DC Voltage Imbalance

  • Nguyen, Nho-Van;Nguyen, Tam-Khanh Tu;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.504-517
    • /
    • 2015
  • This paper presents a novel switching voltage model and an offset-based pulse width modulation (PWM) scheme for multilevel inverters with unbalanced DC sources. The switching voltage model under a DC voltage imbalance will be formulated in general form for multilevel neutral-point-clamped topologies. Analysis of the reference switching voltages from active and non-active switching voltage components in abc coordinates can enable voltage implementation for an unbalanced DC-source condition. Offset voltage is introduced as an indispensable variable in the switching voltage model for multilevel voltage-source inverters. The PWM performance is controlled through the design of two offset components in a subsequence. One main offset may refer to the common mode voltage, and the other offset restricts its effect on the quality of PWM control in related DC levels. The PWM quality can be improved as the switching loss is reduced in a discontinuous PWM mode by setting the local offset, which is related to the load currents. The validity of the proposed algorithm is verified by experimental results.