• 제목/요약/키워드: Acceptable Noise Level

검색결과 37건 처리시간 0.026초

Identification of plastic deformations and parameters of nonlinear single-bay frames

  • Au, Francis T.K.;Yan, Z.H.
    • Smart Structures and Systems
    • /
    • 제22권3호
    • /
    • pp.315-326
    • /
    • 2018
  • This paper presents a novel time-domain method for the identification of plastic rotations and stiffness parameters of single-bay frames with nonlinear plastic hinges. Each plastic hinge is modelled as a pseudo-semi-rigid connection with nonlinear hysteretic moment-curvature characteristics at an element end. Through the comparison of the identified end rotations of members that are connected together, the plastic rotation that furnishes information of the locations and plasticity degrees of plastic hinges can be identified. The force consideration of the frame members may be used to relate the stiffness parameters to the elastic rotations and the excitation. The damped-least-squares method and damped-and-weighted-least-squares method are adopted to estimate the stiffness parameters of frames. A noise-removal strategy employing a de-noising technique based on wavelet packets with a smoothing process is used to filter out the noise for the parameter estimation. The numerical examples show that the proposed method can identify the plastic rotations and the stiffness parameters using measurements with reasonable level of noise. The unknown excitation can also be estimated with acceptable accuracy. The advantages and disadvantages of both parameter estimation methods are discussed.

유체가 부분적으로 채워진 내부지지 연속 원통셸의 진동해석 (Vibration Analysis of Partially Fluid-filled Continuous Cylindrical Shells with Intermediate Supports)

  • 김영완
    • 한국소음진동공학회논문집
    • /
    • 제14권3호
    • /
    • pp.244-252
    • /
    • 2004
  • The theoretical method is developed to investigate the vibration characteristics for the partially fluid-filled continuous cylindrical shells with the intermediate supports. The intermediate supports are simulated by two types of artificial springs : the translational spring for the translation for each direction and the rotational spring for a rotation. The springs are continuously distributed along the circumferential direction. By allowing the spring stiffness to become very high compared to the stiffness of the structure, the rigid intermediate supports are approximated. In the theoretical procedure, the Love's thin shell theory is adopted to formulate the theoretical model. The frequency equation of the continuous cylindrical shell is derived by the Rayleigh-Ritz approach based on the energy method. Comparison and convergence studies are carried out to verify and establish the appropriate number of series term and the artificial spring stiffness to produce results with an acceptable order of accuracy. The effect of intermediate supports, their positions and fluid level on the natural frequencies and mode shapes are studied.

Plasma파암 실험토론회 (The discussion on the Plasma blasting Experimentation)

  • 박철화
    • 화약ㆍ발파
    • /
    • 제16권3호
    • /
    • pp.35-48
    • /
    • 1998
  • 지난 3월 27일 코롱건설(주) 회의실에서 그간 (주)수상중공업에서 새로 개발한 Plasma파암장비에 대한 수차에 걸친 실험결과를 가지고 개발자인 제환영 박사, 개발 DATA에 대한 분석을 맡았던 한국자원연구소 유창하 박사, 실험시 Plasma 파암의 파종별 식별 및 유사 기종과의 비교 등을 검토한 바 있는 허전박사, 그리고 Plasma 암비를 가지고 처음부터 끝까지 현장실험을 맏아 본 박철화 화학비관이기사(전문건설(주) 차장) 등 토론회에서 발표한 내용이다.

  • PDF

자동차 브레이크용 고분자 복합재료의 제조와 그 특성에 관한 연구 (Processing and physical properties of composite materials for the brake lining of the automobile)

  • 손태관;김봉식;김윤해
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제19권4호
    • /
    • pp.51-60
    • /
    • 1995
  • Along with the rapid development of automobile industry in this country the necessity of high quality braking material is ever increased to maintain the comfortness as well as the safety the passengers. Asbestos-based friction materials are banned in the developed countries because of their cancer-inducing effect. This study focuses on the development of non-acbestos friction material with acceptable properties such as wear resistant high temperature endurant and low-noise enducing. We have all the intermediate test results indicating the contribution of each additives. These are qualitatively analyzed. Manufacturing processes such as opening of the kevlar and degasing at elevated temperature is equally important to attain proper level of friction quality.

  • PDF

2중방진 시스템의 실험적 거동해석 (Experimental Behavior Analysis of Double Isolated Anti-Vibration System)

  • 이홍기;이신언
    • 소음진동
    • /
    • 제2권4호
    • /
    • pp.281-292
    • /
    • 1992
  • Two types of vibration problems are encountered in industrial field: active isolation and passive isolation. In a passive type of vibration isolation, a foundation of a delicated machinery such as TEM, SEM, inspection- probe test, photolithograph, etc. is designed to have a vibration amplitude lower than an acceptable limit. In an active type, the isolation is focused on the vibration reduction caused by the machine itself(pump, motor, press, compressor, etc.). The foundation for such a machine should be so designed as to reduce the transmitted vibration below the permissible level prescribed. At any case, a transmissibility and stability must to be considered. Since an active isolation type is aimed for a vibration source, it is useful to isolate the transmitted vibrations energy from a major vibration source at the specific location. In this paper, a designed methodology of double anti-vibration system has been examined in order to have low transmissibility and reliable stability. Also experiment of scale model behavior has been conducted. Finally, the experiment output of the transfer function is compared to the analytical data.

  • PDF

서울시 일부 학교의 실내 공기질 조사 및 인식도 평가 (Assessment of Conscious Coginition Degree and Survey on the Indoor Air Quality at a public School in Seoul)

  • 손종렬;변상훈;김영환;김종혁;조윤수;이재영;박윤주
    • 환경위생공학
    • /
    • 제18권3호통권49호
    • /
    • pp.100-109
    • /
    • 2003
  • Recently, Indoor air quality(IAQ) in workplace, residential environments and schools has been concern of people, scientists and related the public. And so in Seoul has recognized the healthy effect related to IAQ in schools. Therefore, the objective of this study reported in this article were to measure and compare the perception of IAQ of selected air pollutants at three different schools in Seoul. We performed a questionnaire survey of 400 students about their awareness for the importance of IAQ in our school. And we measured the IAQ of 3 schools considering as site region, construction year and studying level. The indoor air pollutants and parameters such as temperature, relative humidity, respirable particulate matter(PM10), formaldehyde(HCHO), total bacteria counts(TBC), carbon dioxide(CO$_2$), and noise were monitored in indoors. In results, all most response of occupant has recognized the awareness of IAQ at schools. The PMIO, TBC and Noise level of all schools were higher than the standard of the public 150 ${mu}$g/m$^3$ and 500CFU/m$^3$, the level formaldehyde(HCHO) was below 0.1 ppm of the healthy guideline of Korea And the concentration of CO$_2$ were investigated below 1,000 ppm of the standard implying ventilation in 2 schools except for 1 school(c school). Finally, the control of most important pollutants of IAQ in school were PM10, TBC and Noise. Therefore, it can be concluded that the indoor air quality of selected 3 schools studied was perceived as acceptable, it is recommended that the government related IAQ was suggested the guideline and control of IAQ problems in schools, and all member relating school need to be effort to reduce the exposure of sources to undesirable indoor pollutants such as Particlate and Noise.

Acceptance Test and Clinical Commissioning of CT Simulator

  • An, Hyun Joon;Son, Jaeman;Jin, Hyeongmin;Sung, Jiwon;Chun, Minsoo
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.160-166
    • /
    • 2019
  • This study examined the clinical use of two newly installed computed tomography (CT) simulators in the Department of Radiation Oncology. The accreditation procedure was performed by the Korean Institute for Accreditation of Medical Imaging. An Xi R/F dosimeter was used to measure the CT dose index for each plug of the CT dose index phantom. Image qualities such as the Hounsfield unit (HU) value of water, noise level, homogeneity, existence of artifacts, spatial resolution, contrast, and slice thickness were evaluated by scanning a CT performance phantom. All test items were evaluated as to whether they were within the required tolerance level. CT calibration curves-the relationship between CT number and relative electron density-were obtained for dose calculations in the treatment planning system. The positional accuracy of the lasers was also evaluated. The volume CT dose indices for the head phantom were 22.26 mGy and 23.70 mGy, and those for body phantom were 12.30 mGy and 12.99 mGy for the first and second CT simulators, respectively. HU accuracy, noise, and homogeneity for the first CT simulator were -0.2 HU, 4.9 HU, and 0.69 HU, respectively, while those for second CT simulator were 1.9 HU, 4.9 HU, and 0.70 HU, respectively. Five air-filled holes with a diameter of 1.00 mm were used for assessment of spatial resolution and a low contrast object with a diameter of 6.4 mm was clearly discernible by both CT scanners. Both CT simulators exhibited comparable performance and are acceptable for clinical use.

Cycle-Consistent Generative Adversarial Network: Effect on Radiation Dose Reduction and Image Quality Improvement in Ultralow-Dose CT for Evaluation of Pulmonary Tuberculosis

  • Chenggong Yan;Jie Lin;Haixia Li;Jun Xu;Tianjing Zhang;Hao Chen;Henry C. Woodruff;Guangyao Wu;Siqi Zhang;Yikai Xu;Philippe Lambin
    • Korean Journal of Radiology
    • /
    • 제22권6호
    • /
    • pp.983-993
    • /
    • 2021
  • Objective: To investigate the image quality of ultralow-dose CT (ULDCT) of the chest reconstructed using a cycle-consistent generative adversarial network (CycleGAN)-based deep learning method in the evaluation of pulmonary tuberculosis. Materials and Methods: Between June 2019 and November 2019, 103 patients (mean age, 40.8 ± 13.6 years; 61 men and 42 women) with pulmonary tuberculosis were prospectively enrolled to undergo standard-dose CT (120 kVp with automated exposure control), followed immediately by ULDCT (80 kVp and 10 mAs). The images of the two successive scans were used to train the CycleGAN framework for image-to-image translation. The denoising efficacy of the CycleGAN algorithm was compared with that of hybrid and model-based iterative reconstruction. Repeated-measures analysis of variance and Wilcoxon signed-rank test were performed to compare the objective measurements and the subjective image quality scores, respectively. Results: With the optimized CycleGAN denoising model, using the ULDCT images as input, the peak signal-to-noise ratio and structural similarity index improved by 2.0 dB and 0.21, respectively. The CycleGAN-generated denoised ULDCT images typically provided satisfactory image quality for optimal visibility of anatomic structures and pathological findings, with a lower level of image noise (mean ± standard deviation [SD], 19.5 ± 3.0 Hounsfield unit [HU]) than that of the hybrid (66.3 ± 10.5 HU, p < 0.001) and a similar noise level to model-based iterative reconstruction (19.6 ± 2.6 HU, p > 0.908). The CycleGAN-generated images showed the highest contrast-to-noise ratios for the pulmonary lesions, followed by the model-based and hybrid iterative reconstruction. The mean effective radiation dose of ULDCT was 0.12 mSv with a mean 93.9% reduction compared to standard-dose CT. Conclusion: The optimized CycleGAN technique may allow the synthesis of diagnostically acceptable images from ULDCT of the chest for the evaluation of pulmonary tuberculosis.

Parameter Design and Analysis for Aluminum Resistance Spot Welding

  • Cho, Yong-Joon;Li, Wei;Hu, S. Jack
    • Journal of Welding and Joining
    • /
    • 제20권2호
    • /
    • pp.102-108
    • /
    • 2002
  • Resistance spot welding of aluminum alloys is based upon Joule heating of the components by passing a large current in a short duration. Since aluminum alloys have the potential to replace steels fur automobile body assemblies, it is important to study the process robustness of aluminum spot welding process. In order to evaluate the effects of process parameters on the weld quality, major process variables and abnormal process conditions were selected and analyzed. A newly developed two-stage, sliding-level experiment was adopted fur effective parameter design and analysis. Suitable ranges of welding current and button diameters were obtained through the experiment. The effects of the factors and their levels on the variation of acceptable welding current were considered in terms of main effects. From the results, it is concluded that any abnormal process condition decreases the suitable current range in the weld lobe curve. Pareto analysis of variance was also introduced to estimate the significant factors on the signal-to-noise (S/N) ratio. Among the six factors studied, fit-up condition is found to be the most significant factor influencing the SM ratio. Using a Pareto diagram, the optimal condition is determined and the SM ratio is significantly improved using the optimal condition.

초소형 무선 내시경용 FSK송신기 설계 및 제작 (Design and Fabrication of FSK Transmitter for Miniaturized Wireless Endoscope)

  • 장경만;문연관;류원열;윤영섭;조진호;최현철
    • 한국전자파학회논문지
    • /
    • 제14권9호
    • /
    • pp.936-943
    • /
    • 2003
  • 초소형 무선내시경은 CMOS Image sensor, FPGA, LED, Battery,DC to DC Converter, Antenna 그리고 송신기로 구성되어 있다. 최대 전자파 노출규제, 시스템의기, 전력소모, 선형성 및 변조방법 등을 고려하여 지름 10 mm, 두께 2.3 mm인 FSK송신기를 설계, 제작 및 측정하였다. 제작된 송신기는 1.2 GHz 대역에서 동작하며, -3.67dBm의 출력전력, -99dBc/Hz(@100 KHz offset)의 위상잡음, -20.17 dBc의 고조파 억압을 나타내었다. 동물실험에서 제작된 무선내시경용 FSK 송신기는 만족할만한 성능을 나타내었다.