References
- Geise RA, McCullough EC. The use of CT scanners in megavoltage photon-beam therapy planning. Radiology. 1977;124:133-141. https://doi.org/10.1148/124.1.133
- Dobbs HJ, Parker RP, Hodson NJ, Hobday P, Husband JE. The use of CT in radiotherapy treatment planning. Radiother Oncol. 1983;1:133-141. https://doi.org/10.1016/S0167-8140(83)80016-4
- Parker RP, Hobday PA, Cassell KJ. The direct use of CT numbers in radiotherapy dosage calculations for inhomogeneous media. Phys Med Biol. 1979;24:802-809. https://doi.org/10.1088/0031-9155/24/4/011
- Garcia-Ramirez JL, Mutic S, Dempsey JF, Low DA, Purdy JA. Performance evaluation of an 85-cm-bore X-ray computed tomography scanner designed for radiation oncology and comparison with current diagnostic CT scanners. Int J Radiat Oncol Biol Phys. 2002;52:1123-1131. https://doi.org/10.1016/S0360-3016(01)02779-1
- Mutic S, Palta JR, Butker EK, Das IJ, Huq MS, Loo LN, et al. Quality assurance for computed-tomography simulators and the computed-tomography-simulation process: report of the AAPM Radiation Therapy Committee Task Group No. 66. Med Phys. 2003;30:2762-2792. https://doi.org/10.1118/1.1609271
- Bissonnette JP, Balter PA, Dong L, Langen KM, Lovelock DM, Miften M, et al. Quality assurance for image-guided radiation therapy utilizing CT-based technologies: a report of the AAPM TG-179. Med Phys. 2012;39:1946-1963. https://doi.org/10.1118/1.3690466
- American College of Radiology. CT accreditation program requirements. American College of Radiology. 2019.
- European Commission. European guidelines on quality criteria for computed tomography. European Commission. 1999.
- Park HJ, Jung SE, Lee YJ, Cho WI, Do KH, Kim SH, et al. The relationship between subjective and objective parameters in CT phantom image evaluation. Korean J Radiol. 2009;10:490-495. https://doi.org/10.3348/kjr.2009.10.5.490
- Deak PD, Smal Y, Kalender WA. Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product. Radiology. 2010;257:158-166. https://doi.org/10.1148/radiol.10100047
- McCollough CH, Leng S, Yu L, Cody DD, Boone JM, Mc-Nitt-Gray MF. CT dose index and patient dose: they are not the same thing. Radiology. 2011;259:311-316. https://doi.org/10.1148/radiol.11101800
- Chun M, Choi YH, Kim JH. Automated measurement of CT noise in patient images with a novel structure coherence feature. Phys Med Biol. 2015;60:9107-9122. https://doi.org/10.1088/0031-9155/60/23/9107
- SSchuhbaeck A, Schaefer M, Marwan M, Gauss S, Muschiol G, Lell M, et al. Patient-specific predictors of image noise in coronary CT angiography. J Cardiovasc Comput Tomogr. 2013;7:39-45. https://doi.org/10.1016/j.jcct.2012.10.011
- Tomic N, Papaconstadopoulos P, Aldelaijan S, Rajala J, Seuntjens J, Devic S. Image quality for radiotherapy CT simulators with different scanner bore size. Phys Med. 2018;45:65-71. https://doi.org/10.1016/j.ejmp.2017.11.017
- Seibert JA, Boone JM, Wootton-Gorges SL, Lamba R. Dose is not always what it seems: where very misleading values can result from volume CT dose index and dose length product. J Am Coll Radiol. 2014;11:233-237. https://doi.org/10.1016/j.jacr.2013.10.010
- Boone JM, Strauss KJ, Cody DD, McCollough CH, McNitt-Gray MF, Toth TL et al. Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations: the report of AAPM task group 204. Med Phys. 2011.
- Mccollough C, Bakalyar DM, Bostani M, Brady S, Boedeker K, Boone JM et al. Use of water equivalent diameter for calculating patient size and size-specific dose estimates (SSDE) in CT: the report of AAPM task group 220. Med Phys. 2014.
- Eck BL, Fahmi R, Brown KM, Zabic S, Raihani N, Miao J, et al. Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction. Med Phys. 2015;42:6098-6111. https://doi.org/10.1118/1.4929973
- Verdun FR, Racine D, Ott JG, Tapiovaara MJ, Toroi P, Bochud FO, et al. Image quality in CT: from physical measurements to model observers. Phys Med. 2015;31:823-843. https://doi.org/10.1016/j.ejmp.2015.08.007
- Battista JJ, Bronskill MJ. Compton scatter imaging of transverse sections: an overall appraisal and evaluation for radiotherapy planning. Phys Med Biol. 1981;26:81-99. https://doi.org/10.1088/0031-9155/26/1/009
- IAEA TRS Report 430. Commissioning and quality assurance of computerized planning systems for radiation treatment of cancer. Austria: International Atomic Energy Agency. 2004; 430.
- Davis AT, Palmer AL, Nisbet A. Can CT scan protocols used for radiotherapy treatment planning be adjusted to optimize image quality and patient dose? A systematic review. Br J Radiol. 2017;90:20160406. https://doi.org/10.1259/bjr.20160406
Cited by
- Basic Physical Principles and Clinical Applications of Computed Tomography vol.32, pp.1, 2019, https://doi.org/10.14316/pmp.2021.32.1.1
- Gold coated contact lens-type ocular in vivo dosimeter (CLOD) for monitoring of low dose in computed tomography: A Monte Carlo study vol.92, 2019, https://doi.org/10.1016/j.ejmp.2021.10.016