• Title/Summary/Keyword: Abutment superimposition

Search Result 11, Processing Time 0.031 seconds

Clinical accuracy of impression technique using digital superimposition of customized abutment with subgingival margin: A case report (치은연하 변연을 가지는 맞춤형 지대주에서 디지털 중첩기술을 이용한 인상채득술의 임상 적용 증례)

  • Kim, Jin-Wan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Lee, Hyeonjong;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.169-175
    • /
    • 2020
  • Traditionally, gingival retraction has been performed to obtain customized abutment impressions with subgingival margins of the implant supported prosthesis. However, gingival retraction may have side effects such as gingival recession and bleed, leading to an inaccurate impression. In order to prevent these problems, in this case, the new technique has been introduced; a customized abutment which is designed for superimposition is used. Before the connection of the abutment to the implant fixture, pre-scanned shape data are stored, and then the optical impression without gingival retraction is obtained after connecting to the fixture. The suprastructure is fabricated by superimposing the two data. This technique showed the clinical efficacy of fabricating the implant supported prosthesis with subgingival margin, which satisfied the aesthetics, convenience, and clinically acceptable marginal and internal fit.

Effect of abutment superimposition process of dental model scanner on final virtual model (치과용 모형 스캐너의 지대치 중첩 과정이 최종 가상 모형에 미치는 영향)

  • Yu, Beom-Young;Son, Keunbada;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.203-210
    • /
    • 2019
  • Purpose: The purpose of this study was to verify the effect of the abutment superimposition process on the final virtual model in the scanning process of single and 3-units bridge model using a dental model scanner. Materials and methods: A gypsum model for single and 3-unit bridges was manufactured for evaluating. And working casts with removable dies were made using Pindex system. A dental model scanner (3Shape E1 scanner) was used to obtain CAD reference model (CRM) and CAD test model (CTM). The CRM was scanned without removing after dividing the abutments in the working cast. Then, CTM was scanned with separated from the divided abutments and superimposed on the CRM (n=20). Finally, three-dimensional analysis software (Geomagic control X) was used to analyze the root mean square (RMS) and Mann-Whitney U test was used for statistical analysis (${\alpha}=.05$). Results: The RMS mean abutment for single full crown preparation was $10.93{\mu}m$ and the RMS average abutment for 3 unit bridge preparation was $6.9{\mu}m$. The RMS mean of the two groups showed statistically significant differences (P<.001). In addition, errors of positive and negative of two groups averaged $9.83{\mu}m$, $-6.79{\mu}m$ and 3-units bridge abutment $6.22{\mu}m$, $-3.3{\mu}m$, respectively. The mean values of the errors of positive and negative of two groups were all statistically significantly lower in 3-unit bridge abutments (P<.001). Conclusion: Although the number of abutments increased during the scan process of the working cast with removable dies, the error due to the superimposition of abutments did not increase. There was also a significantly higher error in single abutments, but within the range of clinically acceptable scan accuracy.

Sinus floor elevation and implant-supported fixed dental prosthesis in the posterior area, with full-digital system: a case report (완전 디지털 시스템을 이용한 상악동 거상술 및 구치부 임플란트 고정성 보철 수복 증례)

  • Gang Soo Park;Sunjai Kim;Se-Wook Pyo;Jae-Seung Chang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.157-164
    • /
    • 2024
  • A variety of digital technologies are being used throughout the entire implant treatment process of diagnosis, surgery, impression, design, and fabrication of prostheses. In this case, using a digital surgical guide, sinus floor elevation was performed without complications, and the implants were placed in the planned position. After the healing period for osseointegration, CAD-CAM (Computer-aided design-Computer-aided manufacturing) customized abutments and provisional prostheses were delivered. While using the provisional prosthesis, occlusal change was observed. To transfer the intermaxillary relationship and abutment position that reflect occlusal change and axial displacement, double scanning and abutment-level digital impressions were taken. Abutment superimposition was used to capture the subgingival margin without gingival retraction. Then, the definitive prosthesis was designed and fabricated with digital system. We report a case applying digital system, to achieve the predictable result as well as the efficient treatment process from implant surgery to fabricating prosthesis in the posterior area.

A STUDY ON THE FIT OF IMPLANT-RETAINED PROSTHESES USING ELECTRIC DISCHARGE MACHINING (전기방전가공법을 이용한 임플랜트 보철물의 적합도 연구)

  • Han Eu-Taek;Kim Yung-Soo;Kim Chang-Whe;Yang Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.1-13
    • /
    • 2001
  • An absolutely passive fit at the interface with the superstructure and the abutment cylinders is need for implant longevity. In this study, a method of cast framework correction using spark erosion technology was evaluated. Electric discharge machining(EDM) is a process that uses electrical discharges, or sparks, to machine metal, The surface being machined is bombared with high-intensity electrical energy pulses that gradually melt away the stock until the desired configuration is obtained. Master model was fabricated by using metal block impression analogue, which fired 5 Branemark squared impression coping in an arc shaped metal block. Then framework using 4mm standard gold cylinder and type IV gold alloy was fabricated. In order to measure the fit of the framework we used both contact and noncontact coordinate measurement machine and data was processed by computer program. After superimposition of gold framework and master model numeric image data the distances between gold cylinder bearing surfaces and abutment replica bearing surfaces, and the angle deviations between gold cylinder and abutment replica centroid points were calculated. The results were as follows 1 The total mean distance (p<0.01) and standard deviation (p<0.001) between the gold cylinders and abutment bearing surfaces were significantly decreased after EDM 2. The total mean of maximum distances was significantly decreased after EDM (p<0.05). 3. After EDM, the mean angle deviation between centroid points was decreased.

  • PDF

Comparative evaluation of the fitness of anterior and posterior interim crowns fabricated by additive manufacturing (적층가공 방식으로 제작한 전치와 구치 임시보철물의 적합도 비교)

  • Park, Young-Dae;Kang, Wol
    • Journal of Technologic Dentistry
    • /
    • v.43 no.4
    • /
    • pp.153-159
    • /
    • 2021
  • Purpose: The purpose of this study was to assess the fitness of anterior and posterior interim crowns fabricated by three different additive manufacturing technologies. Methods: The working model was digitized, and single crowns (maxillary right central incisor and maxillary right first molar) were designed using computer-aided design software (DentalCad 2.2; exocad). On each abutment, interim crowns (n=60) were fabricated using three types of additive manufacturing technologies. Then, the abutment appearance and internal scan data of the interim crown was obtained using an intraoral scanner. The fitness of the interim crowns were evaluated by using the superimposition of the three-dimensional scan data (Geomagic Control X; 3D Systems). The one-way analysis of variance and Tukey posterior test were used to compare the results among groups (α=0.05). Results: A significant difference was found in the fitness of the interim crowns according to the type of additive manufacturing technology (p<0.05). The posterior interim crown showed smaller root mean square value than the anterior interim crown. Conclusion: Since the fitness of the posterior interim crown produced by three types of additive manufacturing technology were all within clinically acceptable range (<120 ㎛), it can be sufficiently used for the fabrication of interim crowns.

Comparison of the accuracy of domestic dental intra-oral scanner(e-scanner) and model scanner (국산 치과용 구강스캐너(e-scanner)와 모델스캐너의 정확도 비교)

  • Kim, Busob;Kim, Jungho
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.53-61
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the discrepancy of scan process in dental intra oral scanner by comparing model scanner and anticipate possibility to introduce intra oral scan technique. Methods: 3D superimposition test was conducted to compare the scan discrepancy. The scanners used in this study are the e-oral scanner, the D750 model scanner, and the high precision CMM(3D Coordinate Measuring Machine). The standard of accuracy verification is ISO 5725-1; trueness and precision. Master model was manufactured by dental stone and scanned 5 times by intra oral, model scanner. Reference data was scanned 5 times by high accuracy CMM to evaluate the trueness. Results: Trueness of D750 scanner were $7.4{\mu}m$ $5.1{\mu}m$ $6.8{\mu}m$ at an abutment, an occluasal, a specific area. and trueness of e-scanner were $20.2{\mu}m$ $27.4{\mu}m$ $37.8{\mu}m$ at an abutment, an occluasal, a specific area. Precision of D750 scanner was $7.04{\mu}m$, e-scanner was $15.95{\mu}m$. Conclusion: When conducting in vitro test, The mean difference of trueness between e-scanner and D750 were $12.8{\mu}m$ at an abutment area, $22.3{\mu}m$ at an occlusal area, $31.0{\mu}m$ at a specific area and $8.91{\mu}m$ in precision. The scan discrepancies are within the range of clinical acceptance.

Restoration of implant-supported fixed dental prosthesis using the automatic abutment superimposition function of the intraoral scanner in partially edentulous patients (부분무치악 환자에서 구강스캐너의 지대주 자동중첩기능을 이용한 임플란트 고정성 보철물 수복 증례)

  • Park, Keun-Woo;Park, Ji-Man;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.79-87
    • /
    • 2021
  • The digital workflow of optical impressions by the intraoral scanner and CADCAM manufacture of dental prostheses is actively developing. The complex process of traditional impression taking, definite cast fabrication, wax pattern making, and casting has been shortened, and the number of patient's visits can also be reduced. Advances in intraoral scanner technology have increased the precision and accuracy of optical impression, and its indication is progressively widened toward the long span fixed dental prosthesis. This case report describes the long span implant case, and the operator fully utilized digital workflow such as computer-guided implant surgical template and CAD-CAM produced restoration after the digital impression. The provisional restoration and customized abutments were prepared with the optical impression taken on the same day of implant surgery. Moreover, the final prosthesis was fabricated with the digital scan while utilizing the same customized abutment from the provisional restoration. During the data acquisition step, stl data of customized abutments, previously scanned at the time of provisional restoration delivery, were imported and automatically aligned with digital impression data using an 'A.I. abutment matching algorithm' the intraoral scanner software. By using this algorithm, it was possible to obtain the subgingival margin without the gingival retraction or abutment removal. Using the digital intraoral scanner's advanced functions, the operator could shorten the total treatment time. So that both the patient and the clinician could experience convenient and effective treatment, and it was possible to manufacture a prosthesis with predictability.

Superimposition: a simple method to minimize occlusal adjustment of monolithic restoration (디지털 장비의 중첩기능을 이용하여 단일체 수복물의 교합조정을 최소화한 증례)

  • Choi, Changhun;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.253-258
    • /
    • 2016
  • The development of translucent zirconia enabled clinicians to choose a monolithic zirconia crown as one treatment modality in the posterior dentition. Careful occlusal adjustments are recommended for monolithic zirconia crowns because grinding zirconia inevitably causes phase transformation, which may deteriorate mechanical properties. intraoral scanners enable the clinician to scan and superimpose a complete tooth structure before preparation onto the prepared abutment. This technique helps to reproduce the original tooth form and occlusion of the patient. In this case report, prostheses were fabricated for patients with cracked or fractured tooth by applying intraoral scanner, Computer aided design-computer aided manufacturing (CAD-CAM) and monolithic zirconia crown to reproduce the occlusion of original tooth and to minimize occlusal adjustment. The clinical results were satisfactory in both esthetic and functional aspects.

Influence of final crystallization process on precision of fit of monolithic CAD/CAM-generated restorations by lithium disilicate: A comparative study (리튬 디실리케이트 최종 결정화 과정이 CAD/CAM으로 제조된 수복물의 적합도에 미치는 영향)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.271-278
    • /
    • 2019
  • Purpose: To quantify the effect of the crystallization process on lithium disilicate ceramic crowns that are fabricated using a computer-aided design/computer-aided manufacturing(CAD/CAM) system, and to determine whether they are clinically acceptable by comparing values before and after the crystallization process. Methods: The maxillary first molar was selected as the abutment for the experiments. Ten working models were prepared. Marginal and internal gap of 4 groups of lithium disilicate crowns(n=10) fabricated with conventional method. Comparison was performed using the silicone replica technique and 3D superimposition analysis. The marginal and internal gaps of the restoration were measured before and after the crystallization process of this prosthesis. The average value of each part(the average of values measured before and after the crystallization) was statistically analyzed using paired t-test(α=0.05). Results: The results from the second phase of this research, which compared the average value of the gap between the marginal and internal fits of the lithium disilicate single crown before and after the crystallization process, indicated that the marginal gap was larger and the internal gap was smaller after the crystallization process, and this difference was statistically significant (P<0.05) in all the parts evaluated. Conclusion: While the shrinkage that occurs during crystallization does affect the marginal and internal fit of the prosthesis, it cannot be concluded to be a major effect because the resultant distortion was within the clinically acceptable range.

Verification of a computer-aided replica technique for evaluating prosthesis adaptation using statistical agreement analysis

  • Mai, Hang-Nga;Lee, Kyeong Eun;Lee, Kyu-Bok;Jeong, Seung-Mi;Lee, Seok-Jae;Lee, Cheong-Hee;An, Seo-Young;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.358-363
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the reliability of computer-aided replica technique (CART) by calculating its agreement with the replica technique (RT), using statistical agreement analysis. MATERIALS AND METHODS. A prepared metal die and a metal crown were fabricated. The gap between the restoration and abutment was replicated using silicone indicator paste (n = 25). Gap measurements differed in the control (RT) and experimental (CART) groups. In the RT group, the silicone replica was manually sectioned, and the marginal and occlusal gaps were measured using a microscope. In the CART group, the gap was digitized using optical scanning and image superimposition, and the gaps were measured using a software program. The agreement between the measurement techniques was evaluated by using the 95% Bland-Altman limits of agreement and concordance correlation coefficients (CCC). The least acceptable CCC was 0.90. RESULTS. The RT and CART groups showed linear association, with a strong positive correlation in gap measurements, but without significant differences. The 95% limits of agreement between the paired gap measurements were 3.84% and 7.08% of the mean. The lower 95% confidence limits of CCC were 0.9676 and 0.9188 for the marginal and occlusal gap measurements, respectively, and the values were greater than the allowed limit. CONCLUSION. The CART is a reliable digital approach for evaluating the fit accuracy of fixed dental prostheses.