Abstract
The development of translucent zirconia enabled clinicians to choose a monolithic zirconia crown as one treatment modality in the posterior dentition. Careful occlusal adjustments are recommended for monolithic zirconia crowns because grinding zirconia inevitably causes phase transformation, which may deteriorate mechanical properties. intraoral scanners enable the clinician to scan and superimpose a complete tooth structure before preparation onto the prepared abutment. This technique helps to reproduce the original tooth form and occlusion of the patient. In this case report, prostheses were fabricated for patients with cracked or fractured tooth by applying intraoral scanner, Computer aided design-computer aided manufacturing (CAD-CAM) and monolithic zirconia crown to reproduce the occlusion of original tooth and to minimize occlusal adjustment. The clinical results were satisfactory in both esthetic and functional aspects.
최근 CAD-CAM과 지르코니아를 이용한 보철물의 제작이 증가하고 있으며 구강스캐너의 발달로 임상 및 기공과정이 단순화되고 있다. 균열치 혹은 치아의 일부가 파절된 경우, 구강스캐너를 사용하여 치아 삭제 전에 치아의 형태를 미리 스캔하고, 추후 수복물 제작 시 중첩을 통해 단일체 지르코니아 전장관을 제작하면 원래 환자의 자연치 형태와 교합을 재현할 수 있다. 본 증례에서는 균열 및 파절된 치아에서 구강 스캐너, CAD-CAM 및 단일체 지르코니아 전장관을 사용하여 삭제 전 치아의 형태와 교합을 재현한 수복물을 제작하였으며, 교합조정을 최소화할 수 있었다. 또한 임상적으로 기능적이고 심미적인 결과를 얻을 수 있었다.