• Title/Summary/Keyword: AT track circuit

Search Result 53, Processing Time 0.03 seconds

Analysis of EMI Between Overlapped Railway Signalling Systems and Its Countermeasure (철도신호시스템 중첩운영으로 인한 전자파장해현상 분석 및 대책)

  • Kho, Young-Hwan;Yoon, Sun-Ho;Choi, Kyu-Hyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1116-1122
    • /
    • 2009
  • ATS(Automatic Train Stop) system makes train stop when it runs over the speed limit and ensure the safe operation of train. Seoul Metro line 2 in Korea, which started its passenger service in 1982, has adopted ATS system for its signaling system. The ATS system has only a train stop function at the time of emergency, and Seoul Metro is planning to replaced them with ATC(Automatic Train Control)/ATO(Automatic Train Operation) system which can provide the dedicated speed control for headway reduction and automatic operation of train. Until all the ATS system is replaced with the new ATC system, both systems are to operate simultaneously at the same metro line. In this situation, ATS system sometimes reveals improper operation: train stops suddenly without any obstacles in front of it. These emergency stops cause interruption of passenger service, and abnormal abrasion of wheels and rail. This paper makes it clear that these interruptions are caused by EMI phenomena between ATS on-board device and ATC wayside device : Signal current flowing in AF track circuit of ATC is turn out to be a EMI source that prevent normal operation of the ATS on-board device. Although the two systems have different frequency-ranges (ATS system has frequency range between $78{\sim}130$[kHz] and ATC system has frequency range between $9.5{\sim}16.5$[kHz]), it turned out that EMI phenomena appears between the both systems. This is investigated by measuring the output signal from ATS on-board device passing over ATC wayside device. The FFT(Fast Fourier Transform) analysis of the signal reveals that AF track circuit signal is transmitted to the ATS on-board device and induce noise causing improper operation. The countermeasures to the EMI phenomena are examined in three ways; blocking EMI transmission, enforcement of EMS (Electromagnetic Susceptibility) of ATS on-board device, and blocking the EMI source. It is suggested that the practical solution be blocking EMI source temporarily, that is breaking AF track circuit signal when the trains with ATS on-board device pass over it. To this purpose, TODS(Train Occupation Detection System) is developed, and has made a success in preventing the EMI problem of Seoul Metro line 2.

A Study on the Overcurrent Relay Modeling and Protective Coordination for Overload in Domestic AC Electrical Railway System (국내 교류 전기철도 급전계통 보호용 과전류 계전기 모델링 및 과부하 보호 협조에 관한 연구)

  • Kim, Hyun-Dong;Cho, Gyu-Jung;Huh, Seung-Hoon;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1121-1127
    • /
    • 2016
  • In this paper, modeling of overcurrent relay(OCR) to protect domestic AC electric railway Auto Transformer(AT) feeding system and operation characteristic analysis on overload condition are described. The target system of this paper is actual site where overload trip of circuit breaker occurs frequently. Because this AT feeding system is made of parallel single track which had a load(electric train) respectively, and is connected with only T phase of Scott Transformer. In addition, this system has been feeding 66kV voltage by KEPCO, not 154kV. We focus on protective coordination of Scott Transformer primary side and secondary side OCR for Korea single track AC electrical railway system in operation currently. We modeled single track AT feeding system and OCR. Also we performed faults and overload analysis for verification of OCR's setting values and system modeling. To analyze above mentioned research, we used PSCAD/EMTDC software tool.

Wind Power Grid Integration of an IPMSG using a Diode Rectifier and a Simple MPPT Control for Grid-Side Inverters

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.548-554
    • /
    • 2010
  • In this paper, a 1.5 kW Interior Permanent Magnet Synchronous Generator (IPMSG) with a power conditioner for the grid integration of a variable-speed wind turbine is developed. The power-conditioning system consists of a series-type 12-pulse diode rectifier powered by a phase shifting transformer and then cascaded to a PWM voltage source inverter. The PWM inverter is utilized to supply sinusoidal currents to the utility line by controlling the active and reactive current components in the q-d rotating reference frame. While the q-axis active current of the PWM inverter is regulated to follow an optimized active current reference so as to track the maximum power of the wind turbine. The d-axis reactive current can be adjusted to control the reactive power and voltage. In order to track the maximum power of the wind turbine, the optimal active current reference is determined by using a simple MPPT algorithm which requires only three sensors. Moreover, the phase angle of the utility voltage is detected using a simple electronic circuit consisting of both a zero-crossing voltage detecting circuit and a counter circuit employed with a crystal oscillator. At the generator terminals, a passive filter is designed not only to decrease the harmonic voltages and currents observed at the terminals of the IPMSG but also to improve the generator efficiency. The laboratory results indicate that the losses in the IPMSG can be effectively reduced by setting a passive filter at the generator terminals.

Design of the 1.8V 6-bit 2GSPS CMOS ADC for the DVD PRML (DVD PRML을 위한 1.8V 6-bit 2GSPS CMOS ADC 설계)

  • Park Yu-Jin;Song Min-kyu
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.537-540
    • /
    • 2004
  • In this paper, CMOS A/D converter with 6bit 2GSPS Nyquist input at 1.8V is designed. In order to obtain the resolution of 6bit and the character of high-speed operation. we present an Interpolation type architecture. In order to overcome the problems of high speed operation further a novel encoder, a circuit for the Reference Fluctuation, an Averaging Resistor and a Track & Hold for the improved SNR are proposed. The proposed Interpolation ADC consists of Track & Holt four resistive ladders with 64 taps, 32 comparators and digital blocks. The proposed ADC is based on 0.18um 1-poly 3-metal N-well CMOS technology, and it consumes 145mW at 1.8V power supply.

  • PDF

A CMOS 5-bit 5GSample/Sec Analog-to-digital Converter in 0.13um CMOS

  • Wang, I-Hsin;Liu, Shen-Iuan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.1
    • /
    • pp.28-35
    • /
    • 2007
  • This paper presents a high-speed flash analog-to-digital converter (ADC) for ultra wide band (UWB) receivers. In this flash ADC, the interpolating technique is adopted to reduce the number of the amplifiers and a linear and wide-bandwidth interpolating amplifier is presented. For this ADC, the transistor size for the cascaded stages is inversely scaled to improve the trade-off in bandwidth and power consumption. The active inductor peaking technique is also employed in the pre-amplifiers of comparators and the track-and-hold circuit to enhance the bandwidth. Furthermore, a digital-to-analog converter (DAC) is embedded for the sake of measurements. This chip has been fabricated in $0.13{\mu}m$ 1P8M CMOS process and the total power consumption is 113mW with 1V supply voltage. The ADC achieves 4-bit effective number of bits (ENOB) for input signal of 200MHz at 5-GSample/sec.

Fabrication and Characteristics of 30〔kVA〕 Superconducting Generator (30(kVA) 초전도발전기 제작 및 특성)

  • ;;;;;;;I. Muta;I. Hoshino
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.2
    • /
    • pp.32-38
    • /
    • 2001
  • A 30[kVA] superconducting generator (SCG) is built and tested at Korea Electrotechnology Research Institute (KERI) in Korea. This superconducting generator has an air-gap winding instead of the typical steel teeth structure. The rotor has 4 field coils of race-track type with NbTi superconducting wired. The rotor is composed of two dampers and a liquid helium composed of two dampers and a liquid helium container in which the field poles reside. The space between the outermost damper and the container is vacuum insulated. A ferrofluid seal is used between the stationary part connected to the couping and the rotor. A helium transfer coupling(HTC) has 3 passages of the recovered heilum gas and a gas flow control system. The open circuit test and sustained short circuit test are preformed to obtain the open circuit characteristics (OCC) and short circuit characteristics (SCC) Also. the test results usder the light load (up to 3.6[kW]) are given. The structure, manufacturing and basis test of the 30[kVA]SCG are discussed.

  • PDF

A 3 ~ 5 GHz CMOS UWB Radar Chip for Surveillance and Biometric Applications

  • Lee, Seung-Jun;Ha, Jong-Ok;Jung, Seung-Hwan;Yoo, Hyun-Jin;Chun, Young-Hoon;Kim, Wan-Sik;Lee, Noh-Bok;Eo, Yun-Seong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.11 no.4
    • /
    • pp.238-246
    • /
    • 2011
  • A 3-5 GHz UWB radar chip in 0.13 ${\mu}m$ CMOS process is presented in this paper. The UWB radar transceiver for surveillance and biometric applications adopts the equivalent time sampling architecture and 4-channel time interleaved samplers to relax the impractical sampling frequency and enhance the overall scanning time. The RF front end (RFFE) includes the wideband LNA and 4-way RF power splitter, and the analog signal processing part consists of the high speed track & hold (T&H) / sample & hold (S&H) and integrator. The interleaved timing clocks are generated using a delay locked loop. The UWB transmitter employs the digitally synthesized topology. The measured NF of RFFE is 9.5 dB in 3-5 GHz. And DLL timing resolution is 50 ps. The measured spectrum of UWB transmitter shows the center frequency within 3-5 GHz satisfying the FCC spectrum mask. The power consumption of receiver and transmitter are 106.5 mW and 57 mW at 1.5 V supply, respectively.

Effect Analysis of Classical Line TI-21 type Audio Frequency Track Circuit from KTX Sancheon Return Current Harmonics (KTX산천 귀선전류고조파가 일반선 TI-21형 AF궤도회로에 미치는 영향분석)

  • Choi, Jae Sik;Kim, Hie Sik;Park, Ju Hun;Kim, Bun Gon
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.1
    • /
    • pp.38-45
    • /
    • 2016
  • The power transformation system of High Speed rolling stocks like KTX-Sancheon has shown excellent control capacities in the areas of riding comfortability, switching efficiency, safety and energy consumption due to technical developments in power-electronics, high speed & large scale integrated semiconductors and microprocessors. However, harmonics from IGBT, a high speed switching device used in the Convertor & Invertor equipment of rolling stocks have given rise to various problems in transformer substations, signaling systems, data transmission systems and facility monitoring systems. Especially, TI21 non-insulated track circuits have malfunctioned due to the influence of returning current harmonics which were generated at around of integer times of the number of power transformation equipment in the frequency domain. This paper, measures and analyzes various schemes to analyze the traveling path of the returning current harmonics generated due to the relationship between the rolling stocks and track circuits on site. Ultimately, theseschemes will be used to design high speed rolling stocks, AF track circuits and a common grounding network.

A review of the train position detection method for neutral section with energized condition (무절연구간을 위한 열차위치검지방식 검토)

  • Lee, Tae-Hoon;Lee, See-Bin;Hong, Hyun-Pyo;Lee, Hee-Soon;Park, Ki-Bum
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1100-1105
    • /
    • 2010
  • The high speed line and conventional line are a single-phase AC feeding system; and power supplies of different phases meet at SS(SubStation)s or SP(Sectioning Post)s. These sections should be negotiated with the main circuit breaker in the traction vehicle switched off, whereby the length of the neutral zone prevents the pantographs shunting adjacent overhead line section. In order for electric railway vehicles to make power running there, there must be a power supply changeover section (approx. for 1km), where a changeover switch changes a power supply to the other power supply of a train running direction sequentially. For a thorough changeover switching control, the precise train position detection is necessarily required. In this paper, to realize the ground-based train position detection method, configuration scheme of train position detection equipment is suggested by using track circuit and axle counter.

  • PDF

A study on modified algorithm to operating train simulation of AT feeding systems (전기철도 AT급전계통의 열차 운형 모의 해석 알고리즘 연구)

  • Choo, Dong-Woog;Kim, Jae-Chul;Jung, Yong-Chul;Jun, Yong-Ju;Lim, Seong-Jeong
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.449-451
    • /
    • 2001
  • This study presents a study on modified algorithm to operating train simulation of AT feeding systems. In this study equivalent impedance is constructed by $Z_c,\;Z_r,\;Z_f,\;Z_{cr},\;Z_{rf},\;Z_{fc}$. The train current flows through the all auto-transformer corresponding to track impedance. To calculate train voltage from analyzing the railway systems, the algorithm is based on the K. C. L, K. V. L, superposition and circuit separation method. Multi-train's voltages are determined by calculating the catenary voltage at each train's position and adding up these train's voltage drop. Case studies use a field operational data, show that the proposed method is easily applied.

  • PDF