• Title/Summary/Keyword: AC surface discharge

Search Result 154, Processing Time 0.027 seconds

A Study on the Optimum Preparation Conditions of MgO Protecting Layer in AC PDP by Unbalanced Magnetron Sputtering (불평형 마그네트론 스파터링에 의한 AC PDP용 MgO 보호층의 최적형성조건에 관한 연구)

  • Kim, Young-Kee;Park, Jung-Tae;Kim, Gyu-Seup;Cho, Jung-Soo;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1096-1098
    • /
    • 1999
  • The performance of as plasma display panels (PDP) is influenced strongly by the surface glow discharge characteristics on the MgO thin films. This paper deals with the optimum preparation conditions of MgO Protecting layer by RF unbalanced magnetron sputtering(UBMS) in surface discharge type AC PDP. The samples prepared with the do bias voltage of -10V showed lower discharge voltage, lower erosion rate as a consequence of ion bombardment, higher optic transparency and higher crack resistance in annealing process than those samples prepared by conventional magnetron sputtering or E-beam eraporation.

  • PDF

New Ramp-reset Waveform for Fast Addressing in AC-PDPs

  • Kim, Oe-Dong;Ahn, Byoung-Nam;Choi, Kwang-Yeol;Yoo, Eun-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.643-646
    • /
    • 2005
  • We present new ramp-reset waveforms that realize fast addressing in AC-PDPs. These waveforms distort the distribution of wall charges on the surface of a phosphor layer: hence, the enhanced electric field helps to ignite a cell faster. They also reduce the black luminance: the divide of erasing ramp down discharges into two parts, i.e. a surface discharge and a vertical discharge, makes lower luminance.

  • PDF

Corona Discharge Characteristics of Transformer Bushing Model with Contaminnations in Air (오염물질에 따른 변압기부싱 모델의 기중 코로나 방전 특성)

  • Pang, Man-Sik;Kim, Woo-Jin;Kim, Young-Seok;Kim, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.5
    • /
    • pp.91-96
    • /
    • 2012
  • The surface of bushing is contaminated with rain, dust, salt and others. A bushing with contaminations in air is serious problem in insulation. Therefore, it is important to understand the inspection and diagnoses of the safety. The ultra-violet rays(UV) camera has attracted interest from the view point of easy judgement. In this paper, we will report on the corona discharge characteristics of surface flashover model with contaminations in air. Also, UV images of discharge and corona pulse count in air are analyzed using prototype UV camera of Korea and a UV sensor with an optic lens. These results are studied at both AC and DC voltage under a non-uniform field.

Improvement of Luminance and Luminous Efficacy in Mid-gap AC Plasma Display Panels (중간간격을 갖는 교류형 플라즈마 디스플레이 표시기의 효율향상을 위한 연구)

  • Choi, Nak-Won;Min, Chung-Sik;Jeong, Dong-Cheol;Seo, Jeong-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.982-988
    • /
    • 2009
  • In a surface type ac PDP having $200{\mu}m$ gap between the surface electrodes, the luminous efficacy has a reciprocal dependence on the sustaining frequency. The discharge current flowing to the address electrodes are measured to investigate the phenomena and spectral intensity from visible light to infra red is measured to verify phosphor saturation with the frequency. Experiments show the discharge between the address and surface electrodes deteriorates the efficacy in high sustaining frequencies. Pulse width modulation is introduced to improve the efficacy. In optimum conditions, we obtained 1.99lm/w and 1.79lm/w at 200kHz and 250kHz, respectively.

A Measurement of Discharge Current of Plasma Display Panel as a cell structure (PDP cell 구조에 따른 방전전류 파형 계측)

  • Lee, W.G.;Ha, S.C.;Lee, S.H.;Shin, J.H.;Cho, J.S.;Park, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1746-1748
    • /
    • 1997
  • The surface discharge type ac plasma display panel(ac PDP) is a flat display devices using gas discharge. In ac PDP, parallel electrodes covered with dielectric layer are on a substrates. The discharge current characteristics are affected by cell structure. In this study, the relationship between the principal design factor and discharge characteristics is discussed, based on experiment, and the current waveform is measured by voltage detector and storage O.S.C. as a parameter of design factor, e.g., electrode gap and width.

  • PDF

A study on the relationship between the Condition of addressing and the characteristics of Surface discharge in ac-PDP (ac-PDP에서의 어드레스 조건과 면방전 특성과 상관관계에 관한 연구)

  • 여재영;이기범;이우근;손제봉;박정후;조정수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.391-394
    • /
    • 1999
  • Until now, there is no report for the relationship between the condition of addressing and the characteristics of surface discharge in ac-PDP. We have known that such these experiment was important to drive ac PDP Therefore, this paper deals with the probability of transfer and the character of luminance according to addressing voltage(Va) and blocking voltage(Vg) in addressing period and sustain voltage in sustaining period and we use waveform according to ADS(Address and Display period Separation) method

  • PDF

Effect of Bias Voltage on the Micro Discharge Characteristics of MgO Film prepared by Unbalanced Magnetron Sputtering

  • Kim, Young-Kee;Park, Jung-Tea;Park, Cha-Soo;Cho, Jung-Soo;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.101-102
    • /
    • 2000
  • The performance of ac plasma display panels (PDP) is influenced strongly by the surface glow discharge characteristics on the MgO thin films. This paper deals with the surface glow discharge characteristics and some physical properties of MgO thin films prepared by reactive RF planar unbalanced magnetron sputtering in connection with ac PDP. The samples prepared with the de bias voltage of -10V showed lower discharge voltage, lower erosion rate by ion bombardment, higher optic transparency and higher crack resistance in annealing process than those samples prepared by conventional magnetron sputtering or E-beam evaporation.

  • PDF

Surface flashover discharge and partial discharge of polymer film in liquid helium (액체 He중 고분자 film의 연면 및 부분방전 연구)

  • 김상현;김현희;정순용;최효상
    • Electrical & Electronic Materials
    • /
    • v.9 no.9
    • /
    • pp.942-948
    • /
    • 1996
  • Electrical properties such as surface flashover discharge and discharge degradations of insulating materials for superconducting cable have been investigated. It is found that the surface voltage is proportional to $l^{0.7}$ (l: discharge length) in liquid helium (LHe). V-t characteristic in LHe was a n=5.5 that was less than liquid nitrogen (L $N_{2}$). After applied AC voltage, the surface condition of polymer films was observed non-eroded areas and eroded areas. The eroded area is depending on the applied voltage. In case of LHe, the crack was observed.d.

  • PDF

The Effects of MgO Activation Process on the Discharge Characteristics of AC PDP (AC PDP 의 방전 특성에 미치는 MgO 활성화 영향에 관한 연구)

  • Kim, Young-Kee;Kim, Jun-Ho;Sohn, Je-Bong;Park, Byeong-Eon;Park, Myung-Joo;Cho, Jung-Soo;Park, Chung-Hoo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.3
    • /
    • pp.209-214
    • /
    • 1999
  • This paper deals with the effects of activation process of MgO thin film on the dielectric characteristics of surface discharge type AC PDP. The discharge voltage decreased with increase in the MgO activation time and temperature until $400^{\circ}C$ under the condition of clean high vacuum. However, for the sample activated above $430^{\circ}C$ the discharge voltage increased. These results may be explained by the MgO morphology change and surface cleaning in the process of activation.

  • PDF

An Address Voltage Stabilization Circuit for the Single-Side Driving Method of AC Plasma Display Panels

  • Kim, Tae-Hyung;Kang, Jung-Won;Lee, Jun-Young
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.884-891
    • /
    • 2009
  • An address voltage stabilization circuit for the single-side driving (SSD) method for AC plasma display panels (PDP) is proposed. The single-side driving method, which eliminates a common sustaining driver, uses only two electrodes in a three electrode AC PDP structure. The high-impedance (Hi-Z) mode operation of the data drive ICs during the sustaining period is needed for surface gas-discharge without misfiring in the SSD method but it produces the problem that the address voltage increases up to the breakdown voltage. The proposed circuit based on a flyback converter can stabilize the address voltage under the breakdown voltage and provide better surface gas-discharge performance without any misfiring in the SSD scheme.