• Title/Summary/Keyword: A-PDA

Search Result 1,756, Processing Time 0.026 seconds

Simultaneous Determination of Vitamin A and E in Infant Formula by Rapid Extraction and HPLC with Photodiode Array Detection (신속추출법 및 PDA-HPLC에 의한 조제분유 중 비타민 A, E의 동시분석)

  • Kwak, Byung-Man;Lee, Ki-Woong;Ahn, Jang-Hyuk;Kong, Un-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.189-195
    • /
    • 2004
  • Rapid and simple method was developed for simultaneous determination of vitamins A and E contents in infant formula. Vitamins A and E were extracted by PDA-HPLC with reversed phase column using organic solvent, and their contents in Certified Reference Material (CRM) and infant formula were determined and compared with results of Food Standards Codex and AOAC method for evaluation of developed method, Vitamins A and E contents in CRM determined by developed method were within certified range of standard values. Developed method has great advantages of simple and rapid sample preparation and simultaneous determination of vitamins A and E by PDA-HPLC using reversed phase column.

Simultaneous Determination of the Seven Phenylpropanoids in Xanthii Fructus Using a HPLC-PDA and LC-MS

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Natural Product Sciences
    • /
    • v.24 no.3
    • /
    • pp.206-212
    • /
    • 2018
  • Xanthii Fructus has been traditionally used for the treatment of rhinitis, rheumatoid arthritis, and eczema. In this study, a high-performance liquid chromatography-photodiode array (HPLC-PDA) method was developed and then used for the simultaneous analysis of eight phenylpropanoids in Xanthii Fructus. The analytical column used for this separation was a $SunFire^{TM}$ $C_{18}$ column, maintained at $40^{\circ}C$. The mobile phase used was 1.0% acetic acid in distilled water and 1.0% acetic acid in acetonitrile with gradient elution. For identify of each component, the mass spectrometer (MS) was used a Waters triple quadrupole mass spectrometer requipped with electrospray ionization (ESI) source. The HPLC-PDA method showed good linearity: correlation coefficients were ${\geq}0.9996$. The limits of detection and quantification of the eight compounds were 0.02 - 0.04 and $0.06-0.14{\mu}g/mL$, respectively. The extraction recoveries ranged from 97.51 to 108.67%. The relative standard deviation values of intra- and inter-day precision were 0.06 - 1.55 and 0.09 - 1.68%, respectively. The validated HPLC-PDA method was applied to simultaneously analyse the amounts of eight phenlypropanoids in Xanthii Fructus.

Ergonomic Design and Evaluation of Scroll and Information Presentation Methods on a PDA (PDA를 위한 스크롤 및 정보 제시 방법의 인간공학적 설계)

  • Beck, Jong-Min;Han, Sung-H;Choi, Hoon-Woo;Jung, Kee-hyo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.1
    • /
    • pp.19-26
    • /
    • 2005
  • Mobile internet access using such devices as PDAs and cellular phones becomes popular as mobile technologies grow. However, the characteristics of small screen devices such as small screen size and pen-based input cause many usability problems. In this study, a human factors experiment was conducted to identify the factors affecting the usability of information search on a PDA. Factors manipulated in the experiment included use of wheel equipment, scroll dimension, and screen orientation. Task completion time, error frequency, and subjective satisfaction level were measured. In addition, various users' behavioral patterns such as scanning routes and mainly used scrolling methods were analyzed. Scroll dimension has a significant effect on task completion time. Scroll equipment and screen orientation affect subjective satisfaction level. The results could be applied to designing information structure of web sites for mobile use by providing vertical scroll and using external scroll equipments.

A Study on Monitoring Technique for Home Server based on Web Camera (웹 카메라 기반 홈 서버용 모니터링 기술에 관한 연구)

  • Jeong Jong-Geun;Cheon Sung-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.8
    • /
    • pp.1754-1761
    • /
    • 2005
  • A monitoring system for the security is increasingly demanded in line with the issue of the infringement of privacy. This paper has conducted the study on the monitoring technique via the Internet using PC or PDA. This is a monitoring system for web-camera based home server, which transmits the images and sound data captured by mike-embedded USB camera, though multiplexer of H.263 and internet. It integrates the operating processors of each device into a unified drive module and provides it the operator to facilitate the system operation and maintenance.

Solitary patent ductus arteriosus in a Japanese macaque (Macaca fuscata)

  • Young-Jin Jang;Byung-Yong Park;Hyun-Jin Tae;Jeoungha Sim;Dongchoon Ahn
    • Korean Journal of Veterinary Service
    • /
    • v.46 no.4
    • /
    • pp.363-368
    • /
    • 2023
  • Patent ductus arteriosus (PDA) in monkeys is very rare. A 9-year-old male Japanese macaque (Macaca fuscata) had an hourglass-shaped PDA with a large luminal diameter. Morphological analysis of the vessel cast and heart revealed cardiovascular pathological changes including pulmonary artery hypertension and right ventricular hypertrophy. However, left ventricle hypertrophy or left atrial enlargement were not observed. This macaque had showed no clinical signs of PDA during its lifetime. We present the first documented case of solitary PDA in a male macaque.

Skew Correction of Business Card Images for PDA Application (PDA 응용을 위한 명함 영상의 회전 보정)

  • 박준효;장익훈;김남철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.12C
    • /
    • pp.1225-1238
    • /
    • 2003
  • We present an efficient algorithm for skew correction of business card images obtained by a PDA (personal digital assistant) camera. The proposed method is composed of four parts: block adaptive binarization (BAB), stripe generation, skew angle calculation, and image rotation. In the BAB, an input image is binarized block by block so as to lessen the effect of irregular illumination and shadow over the input image. In the stripe generation, character string clusters are generated merging adjacent characters and their strings, and then only clusters useful for skew angle calculation are output as stripes. In the skew angle calculation, the direction angles of the stripes are calculated using their central moments and then the skew angle of the input image is determined averaging the direction angles. In the image rotation, the input image is rotated by the skew angle. Experimental results shows that the proposed method yields skew correction rates of about 93% for test images of several types of business cards acquired by a PDA under various surrounding conditions.

Development of Position Information System using GPS and PDA (GPS와 PDA를 이용한 위치정보시스템 개발에 관한 연구)

  • 최병길;홍상기
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.119-124
    • /
    • 2004
  • Tracking correct position information is essential for rescue active in the case of wreck accidents, abscondence and kid napping. Position information system Using GPS and PDA can trace holder's positions exactly and fast, the system can minimize a loss of lives in emergency circumstance. In this study, it is aimed to develop a chasing system to position holders rapidly during distress situation.

  • PDF

Intraaortic Closure of Recanalized PDa with Aneurysmal Formation using Left Heart Bypass (좌심 체외순환을 이용한 재개통된 동맥관 개존증 - 수술 치험 1례 -)

  • 최필조
    • Journal of Chest Surgery
    • /
    • v.23 no.1
    • /
    • pp.178-181
    • /
    • 1990
  • We experienced a rare case of a recanalization and aneurysmal formation of the previously ligated PDA on 18 year-old-girl. Continuous murmur was noted 3 months after operation and this recanalization was confirmed by angiography and cardiac catheterization. It was impossible to mobilize aneurysmal PDA with safety, so we closed the defect using left heart bypass to prevent spinal card injury. Postoperative course was uneventful and the patient was discharged in good condition.

  • PDF

A study on development medicine diagnosis system by Biosignal transmission In Wireless environment to use PDA (무선 환경에서 PDA를 이용한 생체신호전송으로 진단 보조 시스템 개발을 위한 기초 연구)

  • 김동욱;이경진
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.06a
    • /
    • pp.219-221
    • /
    • 2003
  • This system is Emergency patient medical examination and treatment way through biosignal transmission to use PDA. Store measured biosignal that is stored to file to database by Application, This system helps doctor's treatment that transmit patient's biosignal data and patient's symptoms use wireless internet. ThenOffer more than safer medical treatment environment to a doctor and patient

  • PDF