• Title/Summary/Keyword: 5G Device

Search Result 443, Processing Time 0.024 seconds

Photodynamic Therapy for Methicillin-resistant Staphylococcus aureus Strain using Photogem and 630 nm LED

  • Ahn, Jin-Chul;Kim, Dae-Sik;Kwon, Phil-Seung
    • Biomedical Science Letters
    • /
    • v.14 no.4
    • /
    • pp.269-274
    • /
    • 2008
  • Methicillin-resistant Staphylococcus aureus (MRSA) is one of the most common nosocomial pathogens. It is associated with hospitals is now being isolated in the community. The aim of this study was to evaluate the antibacterial effect of photodynamic therapy using Photogem and 630 nm LED on MRSA and methicillin-sensitive Staphylococcus aureus (MSSA). The broth cultured MRSA and MSSA incubated with various concentrations of Photogem (500,50,5 and $0.5{\mu}g/mL$) for 4 h. Then 630 nm LED was given at $9\;J/cm^2$, $20{\mu}l$ of the exposed bacteria solution was inoculated onto agar plate. Plates were incubated for 24 hand colonies were counted. The PDT group was effective in killing MRSA and MSSA at the Photogem dose of $50{\mu}g/mL$. But MSSA is more sensitive than MRSA in photodynamic effect. Other groups (light only, sensitizer only, or no treatment) observed no bacterial cell killing. These results raise the possibility of using PDT with or without antimicrobial drugs to eradicate MRSA and MSSA. In order to confirm this result, we need to further study bacterial death mechanism and in vivo study.

  • PDF

Device Optimization of N-Channel MOSFETs with Lateral Asymmetric Channel Doping Profiles

  • Baek, Ki-Ju;Kim, Jun-Kyu;Kim, Yeong-Seuk;Na, Kee-Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.1
    • /
    • pp.15-19
    • /
    • 2010
  • In this paper, we discuss design considerations for an n-channel metal-oxide-semiconductor field-effect transistor (MOSFET) with a lateral asymmetric channel (LAC) doping profile. We employed a $0.35\;{\mu}m$ standard complementary MOSFET process for fabrication of the devices. The gates to the LAC doping overlap lengths were 0.5, 1.0, and $1.5\;{\mu}m$. The drain current ($I_{ON}$), transconductance ($g_m$), substrate current ($i_{SUB}$), drain to source leakage current ($i_{OFF}$), and channel-hot-electron (CHE) reliability characteristics were taken into account for optimum device design. The LAC devices with shorter overlap lengths demonstrated improved $I_{ON}$ and $g_m$ characteristics. On the other hand, the LAC devices with longer overlap lengths demonstrated improved CHE degradation and $I_{OFF}$ characteristics.

Interference-Aware Channel Assignment Algorithm in D2D overlaying Cellular Networks

  • Zhao, Liqun;Wang, Hongpeng;Zhong, Xiaoxiong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.4
    • /
    • pp.1884-1903
    • /
    • 2019
  • Device-to-Device (D2D) communications can provide proximity based services in the future 5G cellular networks. It allows short range communication in a limited area with the advantages of power saving, high data rate and traffic offloading. However, D2D communications may reuse the licensed channels with cellular communications and potentially result in critical interferences to nearby devices. To control the interference and improve network throughput in overlaid D2D cellular networks, a novel channel assignment approach is proposed in this paper. First, we characterize the performance of devices by using Poisson point process model. Then, we convert the throughput maximization problem into an optimal spectrum allocation problem with signal to interference plus noise ratio constraints and solve it, i.e., assigning appropriate fractions of channels to cellular communications and D2D communications. In order to mitigate the interferences between D2D devices, a cluster-based multi-channel assignment algorithm is proposed. The algorithm first cluster D2D communications into clusters to reduce the problem scale. After that, a multi-channel assignment algorithm is proposed to mitigate critical interferences among nearby devices for each D2D cluster individually. The simulation analysis conforms that the proposed algorithm can greatly increase system throughput.

Development of Click Chemistry in Polymerization and Applications of Click Polymer

  • Karim, Md. Anwarul
    • Rubber Technology
    • /
    • v.13 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • Click chemistry had enjoyed a wealthy decade after it was introduced by K.B.Sharpless and his co-worker on 2001. Since there is no optimized method for synthesis of click polymer, therefore, this paper introduced three click reaction methods such as catalyst, non-catalyst and azide-end capping for fluorene-based functional click polymers. The obtained polymers have reasonable molecular weight with narrow PDI. The polymers are thermally stable and almost emitted blue light emission. The synthesized fluorene-based functional click polymers were characterized to compare the effect of click reaction methods on polymer electro-optical properties as well as device performance on quasi-solid-state dye sensitized solar cells (DSSCs) applications. The DSSCs with configuration of $SnO_2:F/TiO_2/N719$ dye/quasi-solid-state electrolyte/Pt devices were fabricated using these click polymers as a solid-state electrolyte components. Among the devices, the catalyzed click polymer composed device exhibited a high power conversion efficiency of 4.62% under AM 1.5G illumination ($100mW/cm^2$).These click polymers are promising materials in device application and $Cu^I$-catalyst 1, 3-dipolar cycloaddition click reaction is an efficient synthetic methodology.

  • PDF

A study on the evolution of post-smartphone technologies in the 5G technology environment

  • Kwak, Jeong Ho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.4
    • /
    • pp.1757-1772
    • /
    • 2020
  • As the smartphone market becomes saturated, an innovative device equipped with new features is expected to appear soon in mobile communications. In particular, various possibilities were raised regarding the alternative technologies that can develop post-smartphones, which are differentiated from the current smartphones, as Korea commercialized the 5G infrastructure for the first time in the world. Under these circumstances, the Korean government announced the "5G+ Strategy for Realizing Innovative Growth" in April 2019, vowing to build an innovative industrial ecosystem quickly while creating various convergence services based on the 5G infrastructure. As described above, the policy importance of the alternative technologies that will develop post-smartphones is increasing, but the theoretical study on the technology evolution of post-smartphones has not been systematically conducted until now. This study reviewed the alternative technologies that can develop post-smartphones through documentary research, and data mining analysis was performed on the research result using actual data. The policy priority was also set quantitatively for the alternative technologies of post-smartphones in order to determine the alternative post-smartphone technology that the government should focus on given the constraint of limited resources. As a results, autonomous vehicle(43.68%) was found to be most important, followed by artificial intelligence(17.4%) and Internet of Things(13.1%), among alternative technologies that could develop into the post-smartphone.

Development of a Hopper-Type Planting Device for a Walk-Behind Hand-Tractor-Powered Vegetable Transplanter

  • Dihingia, Pramod Chandra;Prasanna Kumar, G.V.;Sarma, Pallab Kumar
    • Journal of Biosystems Engineering
    • /
    • v.41 no.1
    • /
    • pp.21-33
    • /
    • 2016
  • Purpose: In order to ensure that vegetable seedlings (with a soil block around their roots) are planted in an upright orientation after metering in a vegetable transplanter, they need to be dropped freely from a certain height. The walk-behind hand-tractor-powered machines do not have sufficient space to drop the seedlings from that height. In the present work, a hopper-type planting device was developed for the walk-behind hand-tractor-powered vegetable transplanter to ensure that the soil block seedlings are planted in an upright orientation. Methods: Various dimensionless terms were developed based on the dimensional analysis approach, and their effect on the planting of soil block seedlings in an upright orientation (planting efficiency) was studied. The optimum design dimensions of the hopper-type planting device were identified by the Taguchi method of optimization. Results: The ratio of the height of free fall to the sliding distance of the seedling on the surface of the hopper had the highest influence on planting efficiency. The planting efficiency was highest for plants with a height $15{\pm}2cm$. The plant handling Froude number, in interaction with the design of the hopper-type planting device, also significantly affected the planting efficiency. Of the hopper design factors, the length of the slide of the seedlings on the surface of the hopper was most important, and induced sufficient velocity and rotation to cause the seedling to fall in an upright orientation. An evaluation of the performance of the planting device under actual field conditions revealed that the planting efficiency of the developed planting device was more than 97.5%. Conclusions: As the seedlings were fed to the metering device manually, an increase in planting rate increased missed plantings. The planting device can be adopted for any vegetable transplanter in which the seedlings are allowed to drop freely from the metering device.

Development of a Stereotactic Device for Gamma Knife Irradiation of Small Animals

  • Chung, Hyun-Tai;Chung, Young-Seob;Kim, Dong-Gyu;Paek, Sun-Ha;Cho, Keun-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.43 no.1
    • /
    • pp.26-30
    • /
    • 2008
  • Objective : The authors developed a stereotactic device for irradiation of small animals with Leksell Gamma Knife Model C. Development and verification procedures were described in this article. Methods : The device was designed to satisfy three requirements. The mechanical accuracy in positioning was to be managed within 0.5 mm. The strength of the device and structure were to be compromised to provide enough strength to hold a small animal during irradiation and to interfere the gamma ray beam as little as possible. The device was to be used in combination with the Leksell G-$frame^{(R)}$ and $KOPF^{(R)}$ rat adaptor. The irradiation point was determined by separate imaging sequences such as plain X-ray images. Results : The absolute dose rate with the device in a Leksell Gamma Knife was 3.7% less than the value calculated from Leksell Gamma $Plan^{(R)}$. The dose distributions measured with $GAFCHROMIC^{(R)}$ MD-55 film corresponded to those of Leksell Gamma $Plan^{(R)}$ within acceptable range. The device was used in a series of rat experiments with a 4 mm helmet of Leksell Gamma Knife. Conclusion : A stereotactic device for irradiation of small animals with Leksell Gamma Knife Model C has been developed so that it fulfilled above requirements. Absorbed dose and dose distribution at the center of a Gamma Knife helmet are in acceptable ranges. The device provides enough accuracy for stereotactic irradiation with acceptable practicality.

Design and implement of patch type wireless skin temperature measuring system (패치형 무선 피부 온도 측정 시스템의 설계 및 구현)

  • Woo, S.H.;Park, S.Y.;Din, Z. Mohy Ud;Won, C.H.;Lee, J.H.;Park, H.J.;Lee, J.W.;Hong, Y.G.;Suh, J.H.;Youm, Y.G.;Cho, J.H.
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.350-360
    • /
    • 2008
  • In every large hospital, nurses must perform simple repetitive tasks such as measuring body temperature. Such tedious work reduces nurses' motivation to provide quality medical care, which is an important element of the medical services provided by a hospital. If a device were available to measure body temperature, nurses could focus on the more important aspects of providing quality medical care to the patients. However, body temperature is generally measured from the throat, anus, tympanum or armpit, where it is difficult to affix a patch type device. In addition, general body temperature measuring points shows moving artifact error; therefore, it is not good point to continually measure the temperature. In this paper, a patch type skin temperature measuring system was developed. To appropriately measure the skin temperature, a thermal transducer was implemented with a thin (0.5 mm) temperature sensor. The system is small and thin ($H6.6{\sim}5.3{\times}L35{\times}W24\;mm$), and weighs only 5 g including a battery, case and circuit; therefore, it is small and light enough to function as a patch type device. Moreover, the system worked for 5 days. To investigate differences between the experimental and conventional thermometer, simple clinical experiments were performed with 17 volunteers, and the result showed some correlation between the implemented system and conventional thermometer (Correlation coefficient = 0.647, P<0.1).

Two-step thermochemical cycles for hydrogen production using NiFe2O4/m-ZrO2 and CeO2 devices (NiFe2O4/m-ZrO2와 CeO2를 이용한 고온 태양열 열화학 싸이클의 수소 생산)

  • Kim, Chul-Sook;Cho, Ji-Hyun;Kim, Dong-Yeon;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.93-100
    • /
    • 2013
  • Two-step thermochemical cycle using ferrite-oxide($Fe_2O_4$) device was investigated. The $H_2O$(g) was converted into $H_2$ in the first experiment which was performed using a dish type solar thermal system. However the experiment was lasted only for 2 cycles because the metal oxide device was sintered and broken down. Another problem was that the reaction was taken place mainly on a side of the metal oxide device. The m-$ZrO_2$, which was widely known as a material preventing sintering, was applied on the metal oxide device. The ferrite loading rate and the thickness of the metal oxide device were increased from 10.67wt% to 20wt% and from 10mm to 15mm, respectively. The chemical reactor having two inlets was designed in order to supply the reactants uniformly to the metal oxide device. The second-experiment was lasted for 5 cycles, which was for 6 hours. The total amount of the $H_2$ production was 861.30ml. And cerium oxide($CeO_2$) device was used for increasing $H_2$ production rate. $CeO_2$ device had low thermal resistance, however, more $H_2$ production rate than $Fe_2O_4$ device.

An approach to model the temperature effects on I-V characteristics of CNTFETs

  • Marani, Roberto;Perri, Anna G.
    • Advances in nano research
    • /
    • v.5 no.1
    • /
    • pp.61-67
    • /
    • 2017
  • A semi-empirical approach to model the temperature effects on I-V characteristics of Carbon Nanotube Field Effect Transistors (CNTFETs) is proposed. The model includes two thermal parameters describing CNTFET behaviour in terms of saturation drain current and threshold voltage, whose values are extracted from the simulated and trans-characteristics of the device in different temperature conditions. Our results are compared with those of a numerical model online available, obtaining I-V characteristics comparable but with a lower CPU calculation time.