• Title/Summary/Keyword: 4)Ps(12

Search Result 236, Processing Time 0.025 seconds

Acidification of Pig Slurry with Sugar for Reducing Methane Emission during Storage (메탄 배출 저감을 위한 설탕을 이용한 돈 슬러리의 산성화)

  • Im, Seongwon;Oh, Sae-Eun;Hong, Do-giy;Kim, Dong-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.3
    • /
    • pp.81-89
    • /
    • 2019
  • The major problem encountered during the storage of pig slurry (PS) is the release of huge amounts of greenhouse gases (GHGs), which are dominated by methane ($CH_4$). To reduce this, concentrated sulfuric acid has been used as an additive to control the pH of pig slurry to 5.0-6.0. However, other low-risk substitutes have been developed due to some limitations to its use, such as corrosiveness, and hazards to animal and human health. In this study, sugar addition was proposed as an eco-friendly approach for limiting $CH_4$ emission from PS during storage. The pH of PS has been reduced from $7.1{\pm}0.1$ (control) to $5.8{\pm}0.1$, $4.6{\pm}0.1$, $4.4{\pm}0.1$, $4.1{\pm}0.1$, and $4.0{\pm}0.1$, by the addition of 10, 20, 30, 40, and 50 g sugar/L, respectively. Lactate, acetate, and propionate were detected as the dominant organic acids and at sugar concentration above 20 g/L, lactate concentration represented 42-72% (COD basis) of total organic acids. For 40 d of storage, $20.6{\pm}2.3kg\;CO_2\;eq./ton\;PS$ was emitted in the control. Such emission, however, was found to be reduced to $8.7{\pm}0.4$ and $0.4{\pm}0.1kg\;CO_2\;eq./ton\;PS$ at 10 and 20 g/L, respectively. Small amount of $CH_4$ from PS at 10 g/L was emitted until 30 d of storage, while for rest of storage period, it has increased to $8.7{\pm}0.4kg\;CO_2\;eq./ton\;PS$ ( 40% of the control) when methanogens have recovered by increasing pH to 7.0. By the end of storage, VS and COD removal in the control reached 24% and 27%, while their ranges reached 15-4% and 12-17% in the sugar added experiments, respectively. It was found that more than 90% of COD removal was done by aerobic biological process.

The Effect of Pressure Support on Respiratory Mechanics in CPAP and SIMV (CPAP 및 SIMV Mode하에서 Pressure Support 사용이 호흡역학에 미치는 효과)

  • Lim, Chae-Man;Jang, Jae-Won;Choi, Kang-Hyun;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Park, Pyung-Whan;Choi, Jong-Moo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.3
    • /
    • pp.351-360
    • /
    • 1995
  • Background: Pressure support(PS) is becomimg a widely accepted method of mechanical ventilation either for total unloading or for partial unloading of respiratory muscle. The aim of the study was to find out if PS exert different effects on respiratory mechanics in synchronized intermittent mandatory ventilation(SIMV) and continuous positive airway pressure (CPAP) modes. Methods: 5, 10 and 15 cm $H_2O$ of PS were sequentially applied in 14 patients($69{\pm}12$ yrs, M:F=9:5) and respiratory rate (RR), tidal volume($V_T$), work of breathing(WOB), pressure time product(PTP), $P_{0.1}$, and $T_1/T_{TOT}$ were measured using the CP-100 pulmonary monitor(Bicore, USA) in SIMV and CPAP modes respectively. Results: 1) Common effects of PS on respiratory mechanics in both CPAP and SIMV modes As the level of PS was increased(0, 5, 10, 15 cm $H_2O$), $V_T$ was increased in CPAP mode($0.28{\pm}0.09$, $0.29{\pm}0.09$, $0.31{\pm}0.11$, $0.34{\pm}0.12\;L$, respectively, p=0.001), and also in SIMV mode($0.31{\pm}0.15$, $0.32{\pm}0.09$, $0.34{\pm}0.16$, $0.36{\pm}0.15\;L$, respectively, p=0.0215). WOB was decreased in CPAP mode($1.40{\pm}1.02$, $1.01{\pm}0.80$, $0.80{\pm}0.85$, $0.68{\pm}0.76$ joule/L, respectively, p=0.0001), and in SIMV mode($0.97{\pm}0.77$, $0.76{\pm}0.64$, $0.57{\pm}0.55$, $0.49{\pm}0.49$ joule/L, respectively, p=0.0001). PTP was also decreased in CPAP mode($300{\pm}216$, $217{\pm}165$, $179{\pm}187$, $122{\pm}114cm$ $H_2O{\cdot}sec/min$, respectively, p=0.0001), and in SIMV mode($218{\pm}181$, $178{\pm}157$, $130{\pm}147$, $108{\pm}129cm$ $H_2O{\cdot}sec/min$, respectively, p=0.0017). 2) Different effects of PS on respiratory mechanics in CP AP and SIMV modes By application of PS (0, 5, 10, 15 cm $H_2O$), RR was not changed in CPAP mode($27.9{\pm}6.7$, $30.0{\pm}6.6$, $26.1{\pm}9.1$, $27.5{\pm}5.7/min$, respectively, p=0.505), but it was decreased in SIMV mode ($27.4{\pm}5.1$, $27.8{\pm}6.5$, $27.6{\pm}6.2$, $25.1{\pm}5.4/min$, respectively, p=0.0001). $P_{0.1}$ was reduced in CPAP mode($6.2{\pm}3.5$, $4.8{\pm}2.8$, $4.8{\pm}3.8$, $3.9{\pm}2.5\;cm$ $H_2O$, respectively, p=0.0061), but not in SIMV mode($4.3{\pm}2.1$, $4.0{\pm}1.8$, $3.5{\pm}1.6$, $3.5{\pm}1.9\;cm$ $H_2O$, respectively, p=0.054). $T_1/T_{TOT}$ was decreased in CPAP mode($0.40{\pm}0.05$, $0.39{\pm}0.04$, $0.37{\pm}0.04$, $0.35{\pm}0.04$, respectively, p=0.0004), but not in SIMV mode($0.40{\pm}0.08$, $0.35{\pm}0.07$, $0.38{\pm}0.10$, $0.37{\pm}0.10$, respectively, p=0.287). 3) Comparison of respiratory mechanics between CPAP+PS and SIMV alone at same tidal volume. The tidal volume in CPAP+PS 10 cm $H_2O$ was comparable to that of SIMV alone. Under this condition, the RR($26.1{\pm}9.1$, $27.4{\pm}5.1/min$, respectively, p=0.516), WOB($0.80{\pm}0.85$, 0.97+0.77 joule/L, respectively, p=0.485), $P_{0.1}$($3.9{\pm}2.5$, $4.3{\pm}2.1\;cm$ $H_2O$, respectively, p=0.481) were not different between the two methods, but PTP($179{\pm}187$, $218{\pm}181 cmH_2O{\cdot}sec/min$, respectively, p=0.042) and $T_1/T_{TOT}$($0.37{\pm}0.04$, $0.40{\pm}0.08$, respectively, p=0.026) were significantly lower in CPAP+PS than in SIMV alone. Conclusion: PS up to 15 cm $H_2O$ increased tidal volume, decreased work of breathing and pressure time product in both SIMV and CPAP modes. PS decreased respiration rate in SIMV mode but not in CPAP mode, while it reduced central respiratory drive($P_{0.1}$) and shortened duty cycle ($T_1/T_{TOT}$) in CPAP mode but not in SIMV mode. By 10 em $H_2O$ of PS in CPAP mode, same tidal volume was obtained as in SIMV mode, and both methods were comparable in respect to RR, WOB, $P_{0.1}$, but CPAP+PS was superior in respect to the efficiency of the respiratory muscle work (PTP) and duty cycle($T_1/T_{TOT}$).

  • PDF

A 125 MHz CMOS Delay-Locked Loop with 64-phase Output Clock (64-위상 출력 클럭을 가지는 125 MHz CMOS 지연 고정 루프)

  • Lee, Pil-Ho;Jang, Young-Chan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.259-262
    • /
    • 2012
  • This paper describes a delay-locked loop (DLL) that generates a 64-phase clock with the operating frequency of 125MHz. The proposed DLL use a $4{\times}8$ matrix-based delay line to improve the linearity of a delay line. The output clock with 64-phase is generated by using a CMOS multiplex and a inverted-based interpolator from 32-phase clock which is the output clock of the $4{\times}8$ matrix-based delay line. The circuit for an initial phase lock, which is independent on the duty cycle ratio of the input clock, is used to prevent from the harmonic lock of a DLL. The proposed DLL is designed using a $0.18-{\mu}m$ CMOS process with a 1.8 V supply. The simulated operating frequency range is 40 MHz to 200 MHz. At the operating frequency of a 125 MHz, the worst phase error and jitter of a 64-phase clock are +11/-12 ps and 6.58 ps, respectively.

  • PDF

Optimum Level of Farm Machinery Ownership for Cooperative Farm Machinery Utilization System (농업기계(農業機械) 공동이용(共同利用)시스템의 적정기계화(適正機械化) 수준(水準))

  • Yoo, S.N.;Suh, S.R.;Choi, Y.S.;Park, J.G.;Park, S.J.
    • Journal of Biosystems Engineering
    • /
    • v.10 no.2
    • /
    • pp.27-35
    • /
    • 1985
  • This study was carried out to determine the optimum size and number of farm machines for various sizes of land coverage of the cooperative farm machinery utilization systems in Korea-namely Saemaul Mechanized Farming Group (SMFG). Fifty-one SMFG were selected from 8 counties in Chonnam province, and ownership, operation and management of farm machinery were surveyed. Annual covered area, cost and the break-even-point area of farm machinery were analyzed on the bases of the surveyed data and the present governmental subsidy policy, and then the optimum level of farm machinery ownership was determined. The results are summarized as follows: 1. The break-even-point areas of the tractors of 22-23ps, 28ps and 47-50ps were estimated as 12.1ha, 15.3ha and 21.6ha, respectively. The optimum size of a tractor for land sizes of 10-20ha, 20-30ha, and 30-40ha were estimated as 22-23ps, 28ps, and 47-50ps, respectively. 2. The break-even-point area of a rice transplanter was estimated as 3.3ha. The optimum numbers of rice transplanter for land sizes of 10-20ha, 20-30ha, and 30-40ha were estimated as 2,3, and 4, respectively. 3. The break-even-point areas of a speed sprayer (attached on power tiller) and a power sprayer were estimated as 114.6ha and 15.3ha, respectively. The optimum numbers of power sprayer for land sizes of 10-20ha, 20-30ha, and 30-40ha were estimated as 2,3 and 4, respectively. A speed sprayer is desirable for an area of more than 30ha coverage. 4. The break-even-point area of a combine was estimated as 10.7ha. The optimum numbers of combine for land sizes of 10-20ha, 20-30ha, and 30-40ha were estimated as 1,2, and 3, respectively.

  • PDF

Association between ischemic stroke and pyogenic spondylitis in Korea: Nationwide longitudinal cohort study

  • Soo Hyun Lee;Hakyung Kim;In-bo Han;Seung Hun Sheen;Je Beom Hong;Seil Sohn
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.2
    • /
    • pp.143-149
    • /
    • 2023
  • Objective: The purpose of this nationwide age- and sex- matched longitudinal study was to determine the pyogenic spondylitis (PS) increases the incidence of ischemic stroke (IS) in Korea. Methods: From the National Health Insurance Service (NHIS), we collected the patient data for the period from January 1, 2004 to December 31, 2015. PS was classified according to the International Classification of Disease codes M46.2-M46.8, M49.2, and M49.3. By using a 1:5 age- and sex- stratified matching, a total of 628 patients and 3140 control subjects were included in the study. The IS incidence rates in PS and control group was calculated by using the Kaplan-Meier method. The outcome of hazard ratio of IS was estimated by Cox proportional hazards regression analyses. This study did not exclude PS as a result of postoperative complications. Results: According to the study, 51 patients (8.12%) in the PS group and 201 patients (6.4%) in the control group experienced IS. The adjusted hazard ratio of IS in the PS group was 3.419 (95% CI: 2.473-4.729) after adjusting individual medical condition and demographics. Following the results of subgroup analysis, the risk ratio of IS was greater in most of the subgroup categories (male, female, age <65, age >65, non-diabetic, hypertensive, non-hypertensive, dyslipidemic and non-dyslipidemic subgroup). However, the risk of IS did not differ significantly in diabetic subgroup (95% CI: 0.953-4.360). Conclusions: The risk rate of IS increased in patient with pyogenic spondylitis.

Subsidence Due to Groundwater Withdrawal in Kathmandu Basin Detected by Time-series PS-InSAR Analysis

  • Krishnan, P.V.Suresh;Kim, Duk-jin
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.4
    • /
    • pp.703-708
    • /
    • 2018
  • In recent years, subsidence due to excessive groundwater withdrawal is a major problem in the Kathmandu Basin. In addition, on 25 April 2015, the basin experienced large crustal displacements caused by Mw 7.8 Gorkha earthquake. In this study, we applied StaMPS- Persistent Scatterer InSAR (StaMPS PS-InSAR) technique to estimate the spatio-temporal displacements in the basin after the mainshock. 34 Sentinel-1 C-band SAR data are used for measuring subsidence velocity during 2015-2017. We found the maximum subsidence velocity of about 9.02 cm/year and mean subsidence rate of about 8.06 cm/year in the line of sight direction, respectively, in the central part of the basin.

An Optical True Time-Delay for Two-Dimensional X-Band Phased Array Antennas (2차원 X-밴드 위상 배열 안테나용 광 실시간 지연선로)

  • Jung, Byung-Min;Kim, Sung-Chul;Shin, Jong-Dug;Kim, Boo-Gyoun
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.287-294
    • /
    • 2005
  • In this paper, an optical true time-delay (TTD) for two-dimensional (2-D) phased array antennas (PAAs), composed of a multi-wavelength optical source and a fiber optic delay line matrix consisting of $2\times2$ optical switches with optical fiber connected between cross ports, has been proposed. A 2-bit $\times4-bit$ optical TTD for 10-GHz 2-D PAAs has been implemented by cascading a wavelength dependent TTD (WD-TTD) and a wavelength independent TTD (WI-TTD). The unit time delay for WD-TTD and WI-TTD have been chosen as ${\Delta}T=12ps$ and $\Delta\tau=6ps$, respectively. Time delay have been measured at all radiation angles. The maximum delay error for WD-TTD was measured to be 3 ps due to jitter incurred from gain switching. For the case of WI-TTD, error was within ${\pm}\;1\;ps$. The proposed optical TTD for a 2-D PAA has the following advantages: 1) higher gain compared to one-dimensional linear PAAs, 2) stabilization of optical power and wavelength by using a multi-wavelength optical source, and 3) fast beam scan and simple operation due to electronic control of the $2\times2$ optical switches matrix on a column-by-column basis.

Performance Development of the 400cc EFI Small Engine (400cc급 EFI 소형엔진의 성능개발)

  • Park, Sung-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1547-1551
    • /
    • 2011
  • The EFI small engine has been redesigned and manufactured based on a commercial small engine with a carburettor. Performance development of the EFI small engine has been conducted to optimize the operating conditions. Maximum torque and power were 12.56Ps and 25.4Nm, respectively, that were equivalent with carburettor type engine. Brake specific fuel consumption of the EFI small engine has been improved 17% on average compared with that of base small engine with a carburettor. By conducting KG2-6 mode test,HC+NOx was 7.46g/kWh that satisfied EPA Phase 3 regulation. THC has been reduced 41% on average, but NOx has been increased 3.5 times on average due to the improved thermal efficiency.

Biological Activities of Acidic Polysaccharide of Korean Red Ginseng.II.-Effects on Hyperlipidemia induced by Alcohol (홍삼 산성다당체의 생리활성 연구(II)- 알코올성 고지혈증에 미치는 영향)

  • Lee Chung Kyu;Choi Jong-Won;Kim Hyekyung;Han Yong Nam
    • Journal of Ginseng Research
    • /
    • v.23 no.1 s.53
    • /
    • pp.8-12
    • /
    • 1999
  • Acidic polysaccharide of Korean red ginseng (AcPS) was subjected to alcohol-intoxicated rats to check the effects on the growth factors and lipid metabolism. Administration of AcPS showed prevent effects on the body weight, the increased contents of total cholesterol, HDL-cholesterol and neutral glyceride in the serum and total lipid, total cholesterol and neutral glyceride in the liver of alcohol intoxicated rats were significantly normalized. And all of the effects were proportionaly increased with the duration of treatments.

  • PDF

A 0.12GHz-1.4GHz DLL-based Clock Generator with a Multiplied 4-phase Clock Using a 0.18um CMOS Process

  • Chi, Hyung-Joon;Lee, Jae-Seung;Sim, Jae-Yoon;Park, Hong-June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.4
    • /
    • pp.264-269
    • /
    • 2006
  • A $0.12GHz{\sim}1.4GHz$ DLL-based clock generator with the capability of multiplied four phase clock generation was designed using a 0.18um CMOS process. An adaptive bandwidth DLL with a regulated supply delay line was used for a multiphase clock generation and a low jitter. An extra phase detector (PD) in a reference DLL solves the problem of the initial VCDL delay and achieves a fast lock time. Twice multiplied four phase clocks were generated at the outputs of four edge combiners, where the timing alignment was achieved using a coarse lock signal and the 10 multiphase clocks with T/8 time difference. Those four clocks were combined one more time using a static XOR circuit. Therefore the four times multiplication was achieved. With a 1.8V supply, the rms jitter of 2.1ps and the peak-to-peak jitter of 14.4ps were measured at 1.25GHz output. The operating range is $0.12GHz{\sim}1.4GHz$. It consumes 57mW and occupies 450*325um2 of die area.