• Title/Summary/Keyword: 3D-Laser scanner

Search Result 279, Processing Time 0.035 seconds

Object Detection From 3D Terrain Data Gener Ated by Laser Scanner of Intelligent Excavating System(IES) (굴삭 자동화를 위한 레이저 스캐너 기반의 3차원 객체 탐지 알고리즘의 개발)

  • Yoo, Hyun-Seok;Park, Ji-Woon;Choi, Youn-Nyung;Kim, Young-Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.6
    • /
    • pp.130-141
    • /
    • 2011
  • The intelligent excavating system(IES), the development in South Korea of which has been underway since 2006, aims for the full-scale automation of the excavation process that includes a series of tasks such as movement, excavation and loading. The core elements to ensure the quality and safety of the automated excavation equipment include 3D modeling of terrain that surrounds the excavating robot and the technology for detecting objects accurately(i.e., for detecting the location of nearby loading trucks and humans as well as of obstacles positioned on the movement paths). Therefore the purpose of this research is to ensure the quality and safety of automated excavation detecting the objects surrounding the excavating robot via a 3D laser scanning system. In this paper, an algorithm for estimating the location, height, width, and shape of objects in the 3D-realized terrain that surrounds the location of the excavator was proposed. The performance of the algorithm was verified via tests in an actual earthwork field.

The Change of Facial Contouring after Facial Massage (안면 수기 마사지 후 안모의 변화)

  • Im, Eun-Jin;We, Soo-Young;Jung, Da-Woon;Kim, Seong-Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.1
    • /
    • pp.103-108
    • /
    • 2012
  • This study was carried out to qualitatively examine the effect of hand massage on facial contour treatment. In the research, the hand massage was carried out to do facial treatments 2 times a week, total 20 times for 10 weeks on women in their 20s~40s. 3D Laser Scanner was used to analyze. The change of facial volume decreased by $731mm^3$ (p>.05), the thickness of cheekbone area decreased by 0.40mm(p<.05) and the thickness of mastication area decreased by 0.44mm after hand massage(p<.05) By above-mentioned findings, hand massage is likely to be an effective treatment for the reduction of facial volume, the thickness of cheekbone area and mastication area to be basic data of establishing facial line treatment methods.

Development of a time multiplexed HMD type multi-focus 3D display system

  • Kim, Dong-Wook;Lim, Tong-Kun;Kwon, Yong-Moo;Kim, Sung-Kyu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1314-1317
    • /
    • 2006
  • The problem of the conflict between eye convergence and accommodation can be induced at Stereoscopic or multi-view 3D display system using binocular disparity. A multi-focus 3D display system was developed, which can solve the problem. LEDs are used instead of galvano scanner and laser to avoid mechanical moving part at the 3D display system.

  • PDF

DIMENSIONAL ACCURACY OF DENTURE BASE USING LASER SCANNER OF REVERSE ENGINEERING TECHNIC (Reverse Engineering 기법의 레이저 스캐너를 이용한 의치상의 정확도에 관한 연구)

  • Lee, Si-Hyuk;Chang, Ik-Tae;Yim, Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.167-184
    • /
    • 1999
  • The purpose of this study was to evaluate and compare the at of denture bases processed by injection pressing technic using laser scanner of reverse engineering technic. The auther duplicated 20 maxillary edentulous models and 20 mandibular edentulous models, which were scanned on HYSCAN 45C 3D BCANNER(Hymarc Co., Canada). The scanned data were stored in the personal computer using SURFACER (Imageware Co. U.S.A.) software program. After 40 dentures were cured by PERform Inkovac system, SR-Ivocap system, Palajet system, and Sulfon system, they were stored in water at room temperature fir 24 hours. The dentures were scanned on HYSCAN 45C 3D SCANNER(Hymarc Co., Canada). The scanned data were stored in the personal computer using SURFACER (Imageware Co., U.S.A.) software program. By overlapping two images using the same program, the fit between two surfaces was scaled by positive and negative errors. The obtained results were as follows 1. In the upper denture, most of the positive errors occurred on the lingual side of anterior alveolar ridge and the negative errors were on the flange of denture bases. 2. In the lower denture, most of the positive errors occurred on the inner side of lingual flange and the negative errors were on the border of anterior labial flange areas, 3. There were no statistical differences among the positive errors of the four types of injection denture curing methods and also no statistical differences between negative errors except only in negative maximum errors. 4. In PERform system and SR-Ivocap system, they have the tendency of inaccurate at of lower denture bases comparing to that of upper denture bases. 5. The negative error scales were greater than the positive error scales in all types of injection denture curing methods.

  • PDF

System Design and Performance Analysis of 3D Imaging Laser Radar for the Mapping Purpose (맵핑용 3차원 영상 레이저 레이다의 시스템 설계 및 성능 분석)

  • La, Jongpil;Ko, Jinsin;Lee, Changjae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.90-95
    • /
    • 2014
  • The system design and the system performance analysis of 3D imaging laser radar system for the mapping purpose is addressed in this article. For the mapping, a push-bloom scanning method is utilized. The pulsed fiber laser with high pulse energy and high pulse repetition rate is used for the light source of laser radar system. The high sensitive linear mode InGaAs avalanche photo-diode is used for the laser receiver module. The time-of-flight of laser pulse from the laser to the receiver is calculated by using high speed FPGA based signal processing board. To reduce the walk error of laser pulse regardless of the intensity differences between pulses, the time of flight is measured from peak to peak of laser pulses. To get 3D image with a single pixel detector, Risley scanner which stirs the laser beam in an ellipsoidal pattern is used. The system laser energy budget characteristics is modeled using LADAR equation, from which the system performances such as the pulse detection probability, false alarm and etc. are analyzed and predicted. The test results of the system performances are acquired and compared with the predicted system performance. According to test results, all the system requirements are satisfied. The 3D image which was acquired by using the laser radar system is also presented in this article.

A Study on the Use of 3D Human Body Surface Shape Scan Data for Apparel Pattern Making (의류 패턴 설계를 위한 삼차원 인체 체표면 스캔 데이터 활용에 관한 연구)

  • 천종숙;서동애;이관석
    • The Research Journal of the Costume Culture
    • /
    • v.10 no.6
    • /
    • pp.709-717
    • /
    • 2002
  • In the apparel industry, the technology has been advanced rapidly. The use of 3D scanning systems fur the capture and measurement of human body is becoming common place. Three dimensional digital image can be used for design, inspection, reproduction of physical objects. The purpose of this study is to develop a method that drafts men's basic bodice pattern from scanned 3D body surface shape data. In order to pursue this purpose the researchers developed pattern drafting algorithm. The 3D scanner used in this study was Cyberware Whole Body Scanner WB-4. The bodice pattern drafting algorithm from 3D body surface shape data developed in this study is as follows. First, convert geometric 3D body surface data to 3D polygonal mesh data. Second, develop algorithm to lay out 3D polygonal patches onto a plane using Auto Lisp program. The polygon meshes are coplanar, and the individual mesh is continuously in contact with next one The bodice front surface shape data in polygonal patches form was lined up in bust and waist levels. The back bodice was drafted by lining up the polygonal mesh in scapula, chest, and waist levels. in the drafts, gaps between polygons were formed into the darts.

  • PDF

3D Spreader Movement Information by the CCD cameras and the Laser Distance Measuring Unit

  • Lee, Bong-Ki;Lee, Jung-Jae;Kim, Sang-Ju;Lee, Jang-Myung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.241-245
    • /
    • 2003
  • This paper introduces a method that can derive information about the movement of a spreader and skew in order to drive ALS(Automatic Landing System) in the crane used at a harbor. Some methods that use LDL Corner detectors a kind of 2D Laser scanner sensor or Laser distance measuring units to obtain the information in ALS are used presently. But these have some defects in economic efficiency and performance. Therefore, to correct these defects, we propose a method to acquire the information for the movement of a spreader, skew and sway angle using CCD camera image data and Laser distance measuring unit data.

  • PDF

Assessment of the accuracy of laser-scanned models and 3-dimensional rendered cone-beam computed tomographic images compared to digital caliper measurements on plaster casts

  • Yousefi, Faezeh;Shokri, Abbas;Zahedi, Foozie;Farhadian, Maryam
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.429-438
    • /
    • 2021
  • Purpose: This study investigated the accuracy of laser-scanned models and 3-dimensional(3D) rendered cone-beam computed tomography (CBCT) compared to the gold standard (plaster casts) for linear measurements on dental arches. Materials and Methods: CBCT scans and plaster models from 30 patients were retrieved. Plaster models were scanned by an Emerald laser scanner (Planmeca, Helsinki, Finland). Sixteen different measurements, encompassing the mesiodistal width of teeth and both arches' length and width, were calculated using various landmarks. Linear measurements were made on laser-scanned models using Autodesk Meshmixer software v. 3.0 (Autodesk, Mill Valley, CA, USA), on 3D-rendered CBCT models using OnDemand 3D v. 1.0 (Cybermed, Seoul, Korea) and on plaster casts by a digital caliper. Descriptive statistics, the paired t-test, and intra- and inter-class correlation coefficients were used to analyze the data. Results: There were statistically significant differences between some measurements on plaster casts and laser-scanned or 3D-rendered CBCT models (P<0.05). Molar mesiodistal width and mandibular anterior arch width deviated significantly different from the gold standard in both methods. The largest mean differences of laser-scanned and 3D-rendered CBCT models compared to the gold standard were 0.12±0.23 mm and 0.42±0.53 mm, respectively. Most of the mean differences were not clinically significant. The intra- and inter-class correlation results were acceptable for all measurements(>0.830) and between observers(>0.801). Conclusion: The 3D-rendered CBCT images and laser-scanned models were useful and accurate alternatives to conventional plaster models. They could be used for clinical purposes in orthodontics and prostheses.