• 제목/요약/키워드: 2D survey

검색결과 1,854건 처리시간 0.033초

A Study on DEM-based Automatic Calculation of Earthwork Volume for BIM Application

  • Cho, Sun Il;Lim, Jae Hyoung;Lim, Soo Bong;Yun, Hee Cheon
    • 한국측량학회지
    • /
    • 제38권2호
    • /
    • pp.131-140
    • /
    • 2020
  • Recently the importance of BIM (Building Information Modeling) that enables 3D location-based design and construction work is being highlighted around the world. In Korea, the road map has been established to settle the design based on BIM using drone survey results by 2025. As the first step, BIM would be applied to road construction projects worth more than 50 billion Korean Won from 2020. On the other hand, drone survey regulation has been enacted and the data for drone survey cost were also included on Standard of construction estimate in 2020. However, more careful improvement is required to reflect drone survey results in BIM design and construction. Currently, Engineering instructions and Standard of construction estimate specifies that earthwork volume must be calculated by cross section method only. So it is required to add the method of DEM (Digital Elevation Model) based volume calculation on these regulations to realize BIM application. In order for that, this study verified the method of DEM based earthwork volume calculation. To get an accurate DEM for accurate volume computation, drone survey was carried out according to the drone survey regulation and then could get an accurate DEM data which have errors less than 3cm in X, Y and 6.8cm in H. As each DEM cell has 3D coordinate component, the volume of each cell can be calculated by obtaining the height of area of the cell then total volume is calculated by multiplying total number of cells by volume of each cell for the construction area. Verification for the new calculation method compare with existing method was carried out. The difference between DEM based volume by drone survey and cross section based volume by traditional survey was less than 1.33% and it can be seen that new DEM method will be able to be applied to BIM design and construction instead of cross section method.

경남 일부지역의 영양 실태조사 (Nutritional Survey on Gyeong Nam Area)

  • 이종미
    • 대한가정학회지
    • /
    • 제17권3호
    • /
    • pp.35-43
    • /
    • 1979
  • The survey on food intake in Masan and Ulsan city in Gyeong -Sang nam -Do was done by college students of nutrition major under the direction of nutrition professors on August 2nd, 3rd and 4th, 1976. The number of subjects were 260 family members from 54 households. The results are as follow : 1. Daily caloric intake for adults was 1670 kal which was 61.8% of R.D.A.2. The intake of protein appears to be adequate (80g per adult per day ) but fat intake was about 23g which was 5.8% of total calory intake. 3. The level of calcium and iron intake was close to that of R.D.A. However the level of vitamin A & vitamin $B_{2}$ was below R.D.A.

  • PDF

대학교 학생식당의 실내소음 실태 및 원인 분석 사례연구 (A Case Study for Analysis on Present Condition and Cause of Indoor Noise in University Cafeteria)

  • 최윤정;이선아;김혜경
    • 한국주거학회논문집
    • /
    • 제18권5호
    • /
    • pp.85-91
    • /
    • 2007
  • This is a case study for improving the sound environmental quality of cafeteria in university campus. The purpose of the study is to find out the present condition of physical level, type, and cause of indoor noise of cafeteria in university campus by comparison with a restaurant near campus. Research methods were field survey and questionnaire survey. Field survey was consisted of measurement on equivalent and instant noise level and observation on noise type. Respondents of questionnaire survey were 60 students using subject cafeteria or restaurant. Surveys were carried out in the 8th and in the 14th of December 2005. The results are as follows. 1) Indoor noise levels of the cafeteria were measured as $67.2{\sim}76.6$ (average 73.3) dB(A)Leq5min and $60.3{\sim}90.5$ (average 71.2) dB (A), exceeded the indoor noise recommended value of ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers). But noise levels of the restaurant were $61.6{\sim}70.4$ (average 66.9) dB(A)Leq5min and $59.8{\sim}70.6$ (average 64.9) dB(A). 2) The users's responses on major noise type in the cafeteria were 'noise by handling equipment and tableware', 'noise by moving chairs', and 'talcing noise', but 'taking noise' and 'background music' in the restaurant. 3) It was found that indoor noise level of the cafeteria was caused by sound reflection of finishing materials, noise diffusion by open type kitchen, and dragging noise of movable furniture.

모바일 서베이 시스템의 설계 및 구현 (Design and Implementation of Mobile Survey System)

  • 최원산;구용완
    • 정보처리학회논문지D
    • /
    • 제10D권2호
    • /
    • pp.317-326
    • /
    • 2003
  • 이동전화 보급 확대에 따라 가구전화 보유율은 낮아지고 있는 추세이며, 낮은 전화번호 등재율과 재택율은 적격 응답자의 접속률을 감소시키고 있다. 이러한 전화 조사환경의 변화는 새로운 통신 서비스를 활용한 또 다른 조사채널의 확보를 요구하고 있다. 본 논문에서는 무선 데이터 통신 서비스의 일종인 SMS(short message service)를 이용한 모바일 서베이 시스템을 설계하고 구현하였다. 본 시스템은 쿼터할당에 의한 random digit sampling 방식으로 표본을 추출하고, 추출된 표본에 정해진 스케줄러에 의해 SMS를 전송하고, SMS를 받은 조사패널이 통화버튼을 눌러 응답 서버에 접속하여 해당 설문에 응답하면, 응답값은 데이터베이스에 저장되어 실시간으로 분석처리 된다. 본 시스템의 특징은 다른 조사 방법론에 비해 자료수집이 용이하고, 조사비용이 저렴하며, 조사 소요시간을 획기적으로 줄일 수 있다.

Land Subsidence Survey and Analysis Using the Terrestrial LIDAR in Jakarta Bay, Indonesia

  • Park, Han-San
    • 해양환경안전학회지
    • /
    • 제19권3호
    • /
    • pp.233-240
    • /
    • 2013
  • Jakarta is the capital city of Indonesia which has problems of land subsidence with the rates of about 1 to 15 cm/year, up to 20-25 cm/year. The study has examined the land subsidence in Pantai Mutiara, Jakarta Bay which is a reclaimed area by using the Terrestrial LIDAR survey technique. The Terrestrial LIDAR survey results show that the survey site has mean elevation of 0.24 m with the highest elevation of 0.93 m and lowest - 0.35 m. Considering that AHHW (approximate highest high water) is 0.51 m, many areas of the survey site are lying below the AHHW. Pantai Mutiara area is showing various subsidence rates depending on sites although the site is relatively narrow and small (about 1 $km^2$). There is elevation differences of almost 1m within the site. In this study, key information including topography, dike height distribution, and future coastal flooding risk of the survey area was able to be provided by Terrestrial LIDAR survey conducted only once. Especially, as the 3D precision topography effectively conveys important messages relating to vulnerability of the site, policy makers and stakeholders can easily understand the situation of the site.

제5기 국민건강영양조사 자료 중 남성에서 혈청 중 25-hydroxyvitamin D와 만성폐쇄성폐질환의 상관관계 (Relationship between serum 25-hydroxyvitamin D and chronic obstructive pulmonary disease in males in the fifth Korean national health and nutrition examination survey)

  • 정인경
    • Journal of Nutrition and Health
    • /
    • 제47권5호
    • /
    • pp.321-329
    • /
    • 2014
  • 제5기국민건강영양조사 자료중 40세이상 남성을 대상으로 혈액 중 25(OH)D와 COPD의 상관관계를 조사하였다. 25(OH)D는 사분위로 군을 나누어 적용하였고, 2012년 개정된 진료지침에 따라 $FEV_1/FEV_6$ < 0.73인 경우를 COPD로 판정하였다. 다른 요인을 보정하지 않았을 경우에는 25(OH)D와 COPD 사이에 상관관계가 없었으나 흡연상태, 가계소득, 교육수준, 직업, BMI, 만연령및흡연지수를 보정하였을 때는 25(OH)D와 COPD사이에 유의한 상관관계를 보였다. 25(OH)D농도 17~21 ng/mL인 3/4분위군을 기준으로 1/4분위의 경우의 OR 1.643 (95% CI 1.161-2.236), 2/4분위는 OR 1.453 (95% CI 1.045-2.020)으로 유의하게 증가하였다. 결론적으로 40세 이상 남성에서 혈중 25(OH)D 농도는 COPD 유병가능성과 유의한 상관관계를 보였다. 즉, 3/4 분위군 [25(OH)D 17 ng/mL 이상 21 ng/mL 미만]을 기준으로 혈중농도가 낮을수록 COPD 유병가능성이 높았다.

3D Point Cloud 기반 4D map 생성을 통한 노후화 시설물 유지 관리 방안 (The Maintenance and Management Method of Deteriorated Facilities Using 4D map Based on UAV and 3D Point Cloud)

  • 김용구;권종욱
    • 한국건축시공학회지
    • /
    • 제19권3호
    • /
    • pp.239-246
    • /
    • 2019
  • 국내 시설물의 노후화가 급속히 진행되고 있음에 따라 정부는 노후화 시설물의 안정성 검측과 유지관리에 대한 관심을 높이고 있다. 이에 본 연구는 대구광역시 서구 비산 4동/내당 2, 3동의 노후화 지역일대를 조사하고, 비행촬영을 통해 노후화 시설물에 대한 데이터를 획득하여 3D 지도를 구현하였다. 또한 3D 지도에 객관적/주관적 데이터를 추가적으로 기입함으로써 주민들이 쉽게 이해할 수 있으며, 관리자가 노후화 시설물에 대한 유지 보수 관리를 보다 수월하게 진행할 수 있는 4D 지도 생성 방안을 제시하였다.

재난현장조사 공간정보 웹 가시화를 위한 3차원 맵핑시스템 개발 (Development of 3D Mapping System for Web Visualization of Geo-spatial Information Collected from Disaster Field Investigation)

  • 김성삼;노현주;신동윤;이준우;김현주
    • 대한원격탐사학회지
    • /
    • 제36권5_4호
    • /
    • pp.1195-1207
    • /
    • 2020
  • GeoWeb 기술이 발전하면서 재난관리 분야에서도 웹을 통한 2D/3D 공간정보 서비스에 대한 관심과 활용도가 높아지고 있다. 본 논문은 재난사고 현장에서 수집된 다양한 공간정보를 웹 환경에서 시각화하기 위한 3D 공간정보 맵핑 플랫폼 구축에 관한 연구로서, 웹 개발 표준기술인 HTML5/WebGL과 오픈소스를 활용하여 재난사고 현장에서 다양한 형태로 수집된 2D/3D 공간 데이터와 대용량의 LiDAR 점군 데이터에 대한 웹기반의 공간정보 맵핑 서비스 방안을 제시하였다. 첫째, 오픈소스인 GeoServer의 WMS 서비스와 PostGIS를 이용하여 수집된 재난현장 조사 2D 데이터를 공간 DB로 구축한 후 웹 환경에서 렌더링하였다. 둘째, 웹 환경에서 대용량 3D 점군 데이터를 효율적으로 렌더링하기 위하여 다중 해상도의 옥트리 구조를 이용하여 점군 데이터를 2D 타일로 단순화하는 Potree 알고리즘을 적용하였다. 마지막으로 OpenLayers3를 기반으로 3차원 지도를 제어 및 측정하기 위한 기본·응용 기능을 Graphic User Interface(GUI)로 구현하여 2D/3D 공간정보의 웹 시각화를 위한 3D 웹 맵핑 파일럿 시스템을 개발하였다. 향후, 재난현장의 각종 2D 조사 데이터 및 다양한 공간영상정보를 구축된 웹기반 3차원 공간정보시스템에 중첩·표출함으로써 재난사고 과학조사 및 분석 업무에 활용될 수 있을 것으로 기대된다.

제주도 중산간 지역 MT 및 AMT 탐사자료의 2차원 역산 (A two-dimensional inversion of MT and AMT data from mid-mountain area of Jeiu island)

  • 이태종;송윤호;우치다토시히로;박인화;임성근
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2005년도 공동학술대회 논문집
    • /
    • pp.21-26
    • /
    • 2005
  • 제주도 중산간 지역에서 자기지전류 (MT) 및 가청주파수대역 자기지전류 (AMT) 탐사자료를 얻고 이를 이용하여 2차원 역산을 수행하였다. 두 개의 남-북 방향 측선에 대한 역산결과 제주도에서 특징적으로 나타나는 미고결 퇴적층이 10 ohm-m 내외로 두 개의 측선 전반에 걸쳐 나타났으며 측선 중앙부에서 4 km 이상의 심도까지 연장된 저비저항 이상대가 존재하는 것으로 나타났다. 그러나 이 저비저항 이상대가 제주도 주변 바다의 영향인지 과거의 화산활동과 관련된 것인지에 대한 해석을 뒷받침해 줄 어떠한 정보도 아직은 확보되지 않아 향후 추가적인 연구가 요구된다. MT 주파수대만을 이용한 경우와 이것에 AMT 주파수대를 포함해서 역산을 수행한 경우를 비교한 결과, 우리나라와 같이 전기비저항이 높은 지질구조에서는 AMT 자료를 함께 얻어 천부 분해능을 확보하는 것이 심부구조 해석에 도움이 되는 것으로 나타났다.

  • PDF

탐해2호의 240채널 해양탄성파 탐사자료취득 (240 channel Marine Seismic Data Acquisition by Tamhae II)

  • 박근필;이호영;구남형;김경오;강무희;장성형;김영건
    • 지구물리와물리탐사
    • /
    • 제2권2호
    • /
    • pp.77-85
    • /
    • 1999
  • 국내 대륙붕에서의 석유발견 가능성 제고를 위하여 탐해2호가 건조되었으며, 이를 이용하여 국내최초로 240 채널 2차원 해양 탄성파 탐사가 동해에서 이루어졌다. 탐해2호에는 2차원 및 3차원 탄성파 탐사를 위한 음원 및 수신장비, 기록장비 그리고 항측장비 등이 갖추어져 있고, 간단한 선상자료처리 시스템도 포함되어 있다. 음원은 4개의 소배열로 구성되어 있으며 각 소배열은 6개의 에어건으로 구성된다. 전체 음원 용량은 4578 $in^3$이다. 수신장비는 2조의 스트리머로 구성되며 각 조는 240 채널로 길이가 3 km이다. 탐사선 도입 후 처음 시도된 현장탐사에서 성공적인 2차원 탄성파 탐사 자료를 취득하였다. 전산처리를 통하여 자료취득 상태를 점검한 결과 양질의 탄성파 자료가 취득되었음을 확인할 수 있었다. 양질의 자료를 취득하기 위해서는 전체적인 탐사설계, 탐사장비 운용, 현장탐사시 탐사선의 항해, 체계적인 품질관리 등의 기술이 고루 갖추어져야 한다.

  • PDF