• Title/Summary/Keyword: 17inch

Search Result 86, Processing Time 0.024 seconds

Review of Recovery Efficiency for Modified Free-fall Grab (자유낙하식 시료채취기(free-fall grab)의 개량에 따른 회수율 향상 검토)

  • Lee, Gun-Chang;Chi, Sang-Bum;Park, Cheong-Kee;Yoo, Chan-Min;Ko, Young-Tak;Ham, Dong-Jin
    • Ocean and Polar Research
    • /
    • v.26 no.2
    • /
    • pp.361-365
    • /
    • 2004
  • Deep-sea Resources Research Center (DRRC) has been using a free-fall grab (FFG) for the resource evaluation of polymetallic nodules in the KODOS (Korea Deep Ocean Study) area, NE Pacific, since 1992. A FFG model (Model 4200, Benthos) adapting one glass buoy system (diameter 17 inch, net buoyance 25.4 kg) has been used until 1993. Since then, DRRC has carried out a study to increase the recovery rate of FFG and it was found that a revised system adapting an additional buoy (diameter 10 inch, net buoyance 4.5 kg) gives improved results. The nodule sampling tests were performed using two different models for the same study area and the resulting recovery rates were compared. The result shows no distinct difference in recovery time between two models, but average recovery rate of the revised model was increased to 99.44% from 96.06% of the original model.

Performance Evaluation of Advanced Container Security Device(ACSD) system based on IoT(Internet of Things) (IoT 기반 컨테이너 보안 장치 및 시스템 성능 평가)

  • Moon, Young-Sik;Choi, Sung-Pill;Lee, Eun-Kyu;Kim, Jae-Joong;Choi, Hyung-Rim
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.9
    • /
    • pp.2183-2190
    • /
    • 2013
  • Container Security Device (ConTracer) which is suggested in this study is to monitor temperature, humidity, and impact inside of the container while the container is transported. ConTracer could also give information to users when a door of the container is opened over 2 inch within 1 second. Additionally, GPS/GLONASS based global position and status information about container are transmitted to a remote server using IoT (Internet of Things) based communication. In this research, we are looking into the development trend of global container security devices; and applying ConTracer to real freight transport from domestic to overseas using Global Roaming Service which is offered for domestic Mobile Communication Companies as well. As a result, we estimate the performance of ConTracer and verify it.

Thermal Characteristics Investigation of Space-borne Deployable Mesh Antenna according to the Mesh Weaving Density (OPI) (메쉬 제직 밀도(OPI)에 따른 우주용 전개형 메쉬 안테나의 열적 특성 분석)

  • Bong-Geon Chae;Hye-In Kim;Hyun-Kyu Baek;Hyun-Ung Oh
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.4
    • /
    • pp.1-9
    • /
    • 2023
  • Recently, as Synthetic Aperture Radar (SAR), communication, and signal surveillance missions of spacecraft have become more advanced, research has been actively conducted on the deployable large mesh antenna system with excellent storage efficiency compared to the deployment area, and light weight. Deployable Mesh antennae are characterized by an increase in the number of Openings Per Inch (OPI), which is a measure of mesh weaving density as the mission frequency band increases, and this OPI change directly affects the thermal optical properties of the mesh antenna, so research on this is required. In this paper, to verify the thermal relationship between the optical properties of the mesh and antenna reflector, thermal sensitivity analysis between the mesh and the antenna reflector is performed by in-orbit thermal analysis with various optical characteristics of the mesh based on existing overseas research cases. In addition, the temperature gradient effect of the mesh reflector is analyzed.

A Study of Radiation Dose Reduction using Bolus in Medical Radiation Exam (볼루스를 이용한 방사선영상검사 피폭선량저감 연구)

  • Jeong-Min Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.1001-1007
    • /
    • 2023
  • Dose limits are not applied to medical radiation exposure therefore justification and optimization should be essential for protecting radiation. This study explores methods to reduce exposure dose undergoing general radiation exam by bolus(tissue equivalent material) with keeping image quality. Hand PA projection with 50 kVp, 5 mAs, SID 100 cm, and 8×10 inch is referred by covered bolus of thickness 0, 3, 5, 8, and 10 mm for evaluation entrance dose and SNR. The entrance dose (μGy) to the hand by bolus thickness was 125.41±0.288, 106.85±0.255, 104.97±0.221, 91.68±0.299, and 90.94±0.106 showing a significant reduction in radiation exposure depending on if the bolus was used and bolus thickness. The SNR of the image was 13.997, 13.906, 12.240, 12.538, and 12.548 at each bolus thickness, showing no significant difference. It was confirmed that if appropriate thickness and size of bolus is used depending on the type of radiological imaging exam and the body site, a significant radiation dose reduction effect can be achieved without deteriorating image quality.

Effect of Rearing Period on Yield Rate, Physical Properties and Fatty Acid Composition of Duck Meats (출하 일령에 따른 오리육의 수율, 물리적 특성 및 지방산 조성 변화)

  • Chae, Hyun-Seok;Yoo, Young-Mo;Ahn, Chong-Nam;Kim, Dong-Hun;Ham, Jun-Sang;Jeong, Seok-Keun;Lee, Jong-Moon;Choi, Yang-Il
    • Food Science of Animal Resources
    • /
    • v.25 no.3
    • /
    • pp.304-309
    • /
    • 2005
  • This study was performed to investigate the effect of rearing period(45 and 70 days) on the changes of the yield, physical trait and the composition of fatty acids. The average weight of 100 duck meat at 45 days post hatch was 2.2kg. The yield of meats from prime cuts of 2.1kg, which are the most consumed today, was composed to whole legs($14.1\%$), wings($8.7\%$) and breast(12.5\%$). The ratio of whole legs and breast was similar, In the secondary cuts, the meats was consisted in drumstick($12.5\%$), thigh($7.3\%$), breast($11.7\%$), tender lion($0.8\%$), drum matte($4.9\%$) and wing($2.6\%$). Especially, the drumstick was twice higher than the wing. The content of oleic acid was 50.87 to $51.32\%$ and 49.84 to $50.03\%$ in the breasts and leg, respectively. In the breast, meat at 75 days the oleic acid was slightly increased DHA was not detected in the breast meat, However, it was $0.13\%$ in the leg. The $a^{*}$ value in meat color, ranged was 16.67 to 17.92 in the breast and 15.81 to 17.15 in the leg. Statistically, there was no significantly difference between the breast and leg. The cooking loss of the breast and leg was $26.37\%\;and\;30.32\%$, respectively. The shear force value was $2.20\;kg/0.5inch^2$ at 45 and $2.84\;kg/0.5inch^2$ at 75 days post hatchet respectively. Therefore, the raring period was effect on the shear force value, but not on the cooking loss and meat color.

THE C-M DIAGRAM OF THE GLOBULAR CLUSTER, NGC 6752

  • Lee, See-Woo;Cannon, R.D.
    • Journal of The Korean Astronomical Society
    • /
    • v.13 no.1
    • /
    • pp.15-26
    • /
    • 1980
  • The BV-photographic photometry was made for 1714 stars (V<19.5) in NGC 6752. The C-M diagram of this cluster shows an unusually extended blue horizontal branch $(V=13.5{\sim}17.8)$ with a wide gap $(V=16{\sim}16.7)$ and the well defined giant branch with gaps at V=13.85 and 16.2. The turnoff point is defined at $V=17.25{\pm}0.15$ and (B-V) = $0.46{\pm}0.02$. If we take $V_{HB}=13.85$ for NGC 6752, then ${\Delta}V=2.80,\;(B-V)_{0,g}=0.76\;and\;{\Delta}V_{TO}=3.40$ and the chemical abundance is estimated to be [Fe/H]=-1.67 or $Z=4.3{\times}10^{-4}\;and\;Y=0.26$. Some other physical parameters of this cluster are derived and compared with those for the well observed clusters M 3, M 13, M 15 and M 92.

  • PDF

Field Emission Properties of Flat Lamp using Carbon Nanotubes Grownon Glass Substrate (유리기판 위에 성장된 탄소나노튜브를 이용한 평판 램프의 전계방출 특성)

  • Lee, Yang-Doo;Moon, Seung-Il;Han, Jong-Hun;Lee, Yun-Hi;Ju, Byeong-Kwon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.6
    • /
    • pp.647-651
    • /
    • 2004
  • We fabricated the 1-inch diode type flat lamp using CNTs, which were grown directly on soda-lime glass substrate at 600 ∼ 650 $^{\circ}C$ by thermal chemical vapor deposition(CVD) of acetylene gas. Turn- on field was about 2.8 V/${\mu}{\textrm}{m}$. We observed that uniform and high brightness had been obtained. The brightness of CNT flat lamp was measured up to about 14 kcd/$m^2$ at 2000V in spacing of 500 ${\mu}{\textrm}{m}$. The results showed that the CNTs were very good emission source and suitable for application in the lamp.

Fabrication of 5,000V, 4-Inch Light Triggered Thyristor using Boron Diffusion Process and its Characterization (Boron 확산공정을 이용한 5,000V, 4인치 광 사이리스터의 제작 및 특성 평가)

  • Park, Kun-Sik;Cho, Doohyung;Won, Jongil;Lee, Byungha;Bae, Youngseok;Koo, Insu
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.6
    • /
    • pp.411-418
    • /
    • 2019
  • Light-triggered thyristors (LTTs) are essential components in high-power applications, such as HVDC transmission and several pulsed-power applications. Generally, LTT fabrication includes a deep diffusion of aluminum as a p-type dopant to form a uniform p-base region, which needs careful concern for contamination and additional facilities in silicon semiconductor manufacturing factories. We fabricated 4-inch 5,000 V LTTs with boron implantation and diffusion process as a p-type dopant. The LTT contains a main cathode region, edge termination designed with a variation of lateral doping, breakover diode, integrated resistor, photosensitive area, and dV/dt protection region. The doping concentration of each region was adjusted with different doses of boron ion implantation. The fabricated LTTs showed good light triggering characteristics for a light pulse of 905 nm and a blocking voltage (VDRM) of 6,500 V. They drove an average on-state current (ITAVM) of 2,270 A, peak nonrepetitive surge current (ITSM) of 61 kA, critical rate of rise of on-state current (di/dt) of 1,010 A/㎲, and limiting load integral (I2T) of 17 MA2s without damage to the device.

A COMPARATIVE STUDY ON THE FLEXIBILITY OF THE WROUGHT WIRE CLASPS (가공선 크라스프의 가요성에 관한 비교 연구)

  • Eom, Tae-Wan;Chang, Ik-Tae;Kim, Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.261-270
    • /
    • 1989
  • Bend test is one of the methods comparing the physical properties of the clasp wires. The type of bend test used in this investigation was the cantilever loading of a wrought wire. The purpose of this study was to compare the flexibility of a number of commonly used clasp wires, in according to gauge, alloy and heat treatment, under specific condition of load and deflection. Seven noble and one base metal wires were tested under three conditions as follows: (1) as received, (2) quenched (placed in an over at $700^{\circ}C$ for ten minutes and immediately quenched in water at room temperature.), (3) oven cooled (quencned as described, then placed in an oven at $450^{\circ}C$ for two minutes and uniformly slowly cooled to $250^{\circ}C$ in thirty minutes.) The basic test specimen consists of a sample 25 mm in length and 19, 18 gauge in diameter (17 gauge also in two alloys), and the wire was loaded in the form of straight cantilever beams. Force at 0.25 mm (0.01 inch) and 0.5 mm (0.02 inch) deflections for all samples were recorded. The results were as follows ; 1. Ticonium was least flexible and No. 2 was most flexible in according to gauge, alloy and heat treatment. 2. In most of precious wrought wire, the flexibility was increased, but there was no statistically significant differences between as-received and softened condition. 3. There was no statistically differences between as-received and hardened condition. 4. For each alloy, there were statistically significant differences in flexibility due to clasp diameter.

  • PDF

Fabrication and Chracteristics of Cutting Cell with Various Laser Conditions (다양한 레이저 조건에 따른 컷팅셀 제작 및 특성 분석)

  • Park, Jeong Eun;Kim, Dong Sik;Choi, Won Seok;Jang, Jae Joon;Lim, Dong gun
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.3
    • /
    • pp.9-17
    • /
    • 2019
  • Laser cutting cell of solar cells can achieve high voltage and efficiency through more array than conventional 6 inch cell compared to same area. In this study, we fabricated c-Si cutting cell with various lasers and laser conditions such as power, speed, and number of times. In the case of picosecond laser, excellent surface characteristics were obtained due to small surface defects and low thermal damage at the output of 20W and the speed of 100 mm/s. However, it is not possible to fabricate a cutting cell having good characteristics due to nonuniform cutting inside the wafer when the processing for forming a cutting cell is not sufficiently performed. For nanosecond lasers, the best wafer characteristics were obtained for fabrication of excellent cutting cells at a frequency of 500 kHz and a laser speed of 100 mm/s. However, the nanosecond laser has not been processed sufficiently in the condition of a number of times. As a result, it was confirmed that the wafer thickness was cut by $63{\mu}m$ of the cell thickness of $170{\mu}m$ in the condition of five times of laser process. It was found that more than 30% of the wafer thickness had to be processed to fabricate the cutting cell. After cutting the 6-inch cell having the voltage of 0.65 V, we obtained the voltage of about 0.63 V.