• Title/Summary/Keyword: 1인

Search Result 16,683, Processing Time 0.059 seconds

Effect of single-person beauty company's managerial capabilities on management performance -Focusing on the moderating effects of beauty education institutions- (1인 미용기업 경영자 역량이 경영성과에 미치는 영향 -미용교육기관의 조절효과를 중심으로-)

  • Choi, Yun-Kyoung
    • Journal of Digital Convergence
    • /
    • v.20 no.5
    • /
    • pp.149-155
    • /
    • 2022
  • This study checks how the managerial competency of a single beauty company affects management performance, and the managerial competency of a single beauty company has a moderating effect of a beauty education institution between management performance and presents related implications. As for the survey for the study, direct surveys and online surveys were conducted from May 1 to May 31, 2021, and a total of 218 copies were used for empirical analysis. As a result of the analysis, the managerial competence of a single beauty company was divided into three factors: psychological characteristics, technical characteristics, and management ability, and all factors influenced management performance. In addition, it was analyzed that the managerial competency of a single beauty company in beauty education institutions has a moderating effect in the relationship between management performance. Therefore, managers of single-person beauty companies should make various efforts to improve managerial capabilities that affect management performance, and above all, it is important to select educational institutions necessary for each reverse direction.

ZVS Phase-Shift Full-Bridge Inverter for 100kV High Voltage Output of X-ray driving Circuit (X-ray 구동회로의 100kV 고전압 출력을 위한 ZVS Phase-shift Full-Bridge 인버터)

  • Kang, Kyung-soo;Kim, Se-min;Kim, Sang-Yeon;Lee, Jeong-jun;Roh, Chung-Wook
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.355-356
    • /
    • 2016
  • 기존 X-ray용 인버터의 경우, 일반적인 Full-bridge 인버터를 사용하여 낮은 효율이 발생하기 때문에 1.6kW이상의 고전압 출력을 요구하는 X-ray를 사용할 수 없는 문제점이 있다. 본 논문은 X-ray 구동용 인버터의 높은 출력이 가능한 고전압 출력용 ZVS Phase-Shift Full Bridge 인버터를 제안한다. 기존의 X-ray 구동용 인버터를 사용할 경우에는 낮은 효율 및 높은 출력 전압을 발생 시킬 수 없기 때문에 X-ray 발생이 어려우며, 높은 출력을 발생시키기 위해서는 회로의 전체적인 부피가 커지고 제작단가가 증가하는 단점이 있다. 반면 제안된 회로는 X-ray 구동용 ZVS Phase-Shift Full Bridge 인버터로써, 영전압 스위칭을 통해 높은 효율로 인버터 구동이 가능하고, 높은 출력 전압을 발생 시킬 수 있기 때문에 회로의 소형화 및 고출력 X-ray 발생이 가능한 장점을 갖는다. 본 논문에서는 제안된 회로의 이론적인 특성을 분석하고 모의실험을 통해 확인하였으며, 1.6kW급 X-ray 구동 인버터 회로에 적용하여 실험을 통해 우수성을 검증하였다.

  • PDF

Qusai-Watkins-Johnson Inverter (의사-왓킨슨-존슨 인버터)

  • Kim, Jeonghun;Kim, Kisu;Cha, Honnyong;Kim, Heung-Geun
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.33-35
    • /
    • 2018
  • 본 논문에서는 Quasi-Watkins-Johnson(qWJ) 인버터를 제안한다. 단상 qWJ 인버터는 기존의 Watkins-Johnson(WJ) 인버터에서 간단한 회로 수정을 통해 제안되며, 기존의 WJ 인버터의 모든 장점을 유지한다. 제안한 인버터는 모든 능동 스위치가 비절연형 게이트 구동을 하므로 게이트 구동회로의 부담을 덜어주고 기존 방식에 비해 적은 비용과 작은 크기로 구현할 수 있다. 또한, 제안한 인버터는 기존의 하프-브릿지 인버터의 출력전압보다 더 큰 출력전압을 가진다. 3상 qWJ 인버터는 출력전압이 입력전압의 2배까지 승압이 가능하다. 계통연계형 태양광 시스템에 적용 시, 기존의 3상 전압형 인버터는 누설전류로 인해 안정성에 문제가 생길 수 있지만, 제안한 인버터는 누설전류에 의한 문제가 생기지 않는다. 그러므로 제안한 인버터는 누설전류를 줄이기 위한 추가적인 회로가 필요하지 않고 적은 비용과 작은 사이즈로 계통연계형 태양광 인버터 시스템을 구현할 수 있다. 이러한 장점들은 3상 qWJ 인버터에서 더욱 현저하게 드러난다. 1kW의 시제품을 제작하여 제안한 인버터의 성능을 검증하였다.

  • PDF

A Development of 1C1M Propulsion Control System for High Speed Train (고속전철용 1C1M 추진제어장치 개발)

  • Jeong, Man-Kyu;Cho, Sung-Joon;Park, Geon-Tae;Lee, Kwang-Ju
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.229-230
    • /
    • 2014
  • 본 논문은 고속전철용 1C1M 추진제어장치의 개발에 관한 것이다. KTX-산천 추진제어장치와 호환되도록 컨버터 부분은 DC링크를 공유하여 컨버터 2대를 병렬 운전하도록 하였다. 인버터 2대를 배치하여 견인전동기를 개별적으로 제어할 수 있도록 하였다. 동일 대차에서 1축, 2축 바퀴의 직경차는 1C2M 추진제어장치에서는 4mm 이하로 관리되고 있다. 1C1M 추진제어장치를 개발하여 바퀴의 직경차가 40mm 이하로 관리되도록 바퀴 직경관리 기준을 향상 시켜 바퀴의 사용 시간을 연장할 수 있도록 하였다. 컨버터, 인버터가 중고장에 의하여 차단 시 고장난 컨버터, 인버터 군을 차단하고 나머지 컨버터, 인버터 군은 재기동하는 충전회로 및 시퀀스를 추가하여 50% 동력을 사용하도록 하였다. 개발된 추진제어장치는 전력회로 시험, 기능 동작 시험을 통하여 제어가 원활히 수행됨을 확인하였다.

  • PDF

A Study on PWM Inverter to control Fixed Total Harmonic Distortion (고조파 왜율의 일정 제어를 위한 PWM 인버터에 관한 연구)

  • Song, Eon Bin
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.2
    • /
    • pp.130-130
    • /
    • 1995
  • 이 논문은 인버터의 출력파형에 포함되는 고조파 성분들을 제거하기 위한 PWM인버터의 소프트웨어 제어기법을 제시하고 있다. 제안한 기법에 의하면, 가변속 운전이나 무정전 전원 공급 시스템 응용시 인버터 출력의 고조파 왜율을 일정하게 낮출 수 있어 인버터의 성능을 크게 향상시킬 수 있다. 주파수 비36, 변조지수 1.2∼2.0인 제어모드에서 본 인버터는 고조파 왜율을 5[%]이내의 범위에서 운전할 수 있다.

A Study on PWM Inverter to control Fixed Total Harmonic Distortion (고조파 왜율의 일정 제어를 위한 PWM 인버터에 관한 연구)

  • 송언빈
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.2
    • /
    • pp.42-49
    • /
    • 1995
  • 이 논문은 인버터의 출력파형에 포함되는 고조파 성분들을 제거하기 위한 PWM인버터의 소프트웨어 제어기법을 제시하고 있다. 제안한 기법에 의하면, 가변속 운전이나 무정전 전원 공급 시스템 응용시 인버터 출력의 고조파 왜율을 일정하게 낮출 수 있어 인버터의 성능을 크게 향상시킬 수 있다. 주파수 비36, 변조지수 1.2∼2.0인 제어모드에서 본 인버터는 고조파 왜율을 5[%]이내의 범위에서 운전할 수 있다.

  • PDF

Analyzing Problem Instance Space Based on Difficulty-distance Correlation (난이도-거리 상관관계 기반의 문제 인스턴스 공간 분석)

  • Jeon, So-Yeong;Kim, Yong-Hyuk
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.414-424
    • /
    • 2012
  • Finding or automatically generating problem instance is useful for algorithm analysis/test. The topic has been of interest in the field of hardware/software engineering and theory of computation. We apply objective value-distance correlation analysis to problem spaces, as previous researchers applied it to solution spaces. According to problems, we define the objective function by (1) execution time of tested algorithm or (2) its optimality; this definition is interpreted as difficulty of the problem instance being solved. Our correlation analysis is based on the following aspects: (1) change of correlation when we use different algorithms or different distance functions for the same problem, (2) change of that when we improve the tested algorithm, (3) relation between a problem instance space and the solution space for the same problem. Our research demonstrates the way of problem instance space analysis and will accelerate the problem instance space analysis as an initiative research.

Analysis of Voltage Delay and Compensation for Current Control in H-Bridge Multi-Level Inverter (H-브릿지 멀티레벨 인버터의 전압 지연 해석 및 전류 제어 보상)

  • Park, Young-Min;Ryu, Han-Seong;Lee, Hyun-Won;Jung, Myung-Gil;Lee, Se-Hyun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.43-51
    • /
    • 2010
  • This paper proposes an analysis of voltage delay and compensation for current control in H-Bridge Multi-Level (HBML) inverters for a medium voltage motor drive with vector control. It is shown that the expansion and modularization capability of the HBML inverter is improved in case of using Phase-Shifted Pulse Width Modulation (PSPWM) since individual inverter modules operate more independently. But, the PSPWM of HBML has a phase difference between reference voltage and real voltage, which can cause instability in the current regulator at high speed where the ratio of the sampling frequency to the output frequency is insufficient. This instability of the current regulator is removed by adding a proposed method which compensate a phase difference between reference voltage and real voltage. The proposed method is suitable for HBML inverter controlled by PSPWM with low switching frequency and high speed motor drive. The validity of the proposed method is verified experimentally on 6,600[V] 1,400[kW] induction motor fed by an 13-level HBML inverter.

Component Inspection process for EJB (EJB 컴포넌트의 인스펙션 프로세스 모델)

  • 남준기;한혁수
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04c
    • /
    • pp.124-126
    • /
    • 2003
  • 인스펙션은 소프트웨어 개발 프로세스에서 작성된 산출물에 대한 품질 보증 활동의 하나이다. 산출물에서 결함을 찾을 수 있는 가장 정형적. 효율적, 경제적인 방범이 인스펙션이라고 알려져 있다[1]. 인스펙션은 테스트 전에 결함을 검출하여 소프트웨어의 품질을 높이고, 테스트 후에 발견되는 결함을 줄임으로써 유지보수에 드는 시간과 비용을 절감시킨다. 본 논문에서는 인스펙션 중에서도 코드에 관련된 인스펙션을 연구하고자 한다. 현재의 개발 패러다임은 CBD(Component Based Development)로 가고 있다. 소프트웨어 개발이 많아지고 규모가 커짐에 따라 재사용성이 뛰어난 컴포넌트로 개발들이 이루어지고 수행되고 있다. 컴포넌트를 개발할 때에도 품질은 중요한 문제이기 때문에 연구가 필요하다. 기존의 패러다임에서는 품질을 위한 인스펙션에 관한 많은 연구들이 있었고 진행되었다. 하지만 CBD에서의 품질을 위한 인스펙션에 관한 연구는 많이 이루어지지 않고 있다. 본 논문에서는 이러한 문제점을 알아보고 EJB(Enterprise Java Beans) 컴포넌트에 대한 코드 인스펙션을 통해 결함을 줄이고 품질을 향상시키기 위한 컴포넌트 인스펙션 프로세스(Component Inspection Process)를 실시한다. 프로세스의 각 단계에서는 UML 다이어그램. EJB의 콜백 메소드 흐름 다이어그램, 그리고 체크리스트를 사용한다. CIP 사용함으로써 CBD에서의 많은 결함을 줄이고 품질을 향상시킬 수 있게 될 것이다.

  • PDF

Control of Wastewater Treatment Removing Phosphate Based on ASM No. 2 Simplified Model and Investigation of Luxury Uptake Limitation (ASM No. 2 간략화 모델에 기초한 인산염의 제어 및 인섭취 제한현상에 대한 고찰)

  • Kim, Shin-Geol;Choi, In-Su;Koo, Ja-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.181-189
    • /
    • 2008
  • Phosphate is the limiting factor leading to the eutrophication in nature and has been usually removed by the luxury uptake of PAOs(Phosphate accumulating organisms). The purpose of this study was the control of wastewater treatment removing phosphorus. The control of wastewater treatment process was performed by optimal and adaptive control. They were performed as followings. Firstly the inflow phosphate concentration was measured and the optimal aeration time was calculated by simplified ASM No. 2 for the phosphate to be 1.0 mg/L in effluent. It was optimal control. But when the phosphate concentration in effluent was not 1.0 mg/L, adaptive control was necessary to coincide the objective of control with real value. Then it was performed as the objective phosphate concentration in effluent was changed according to calculation of errors and it was adaptive control. The wastewater treatment process had been controlled by them for about one month. The range of phosphate concentration in effluent 0.2$\sim$3.2 mg/L and the average of it was 1.0 mg/L. The limitation of luxury uptake occurred two times while wastewater treatment process was running. After the analysis of laboratory tests, we knew the reasons were the shortage of ammonia nitrogen and the excessive aeration.