• Title/Summary/Keyword: 1,2-unit

Search Result 8,890, Processing Time 0.034 seconds

DEVELOPMENT OF INTELLIGENT POWER UNIT FOR HYBRID FOUR-DOOR SEDAN

  • Aitaka, K.;Hosoda, M.;Nomura, T.
    • International Journal of Automotive Technology
    • /
    • v.4 no.2
    • /
    • pp.57-64
    • /
    • 2003
  • The Intelligent Power Unit (IPU) utilized in Honda's Civic Hybrid Integrated Motor Assist (IMA) system was developed with the aim of making every component lighter, more compact and more efficient than those in the former model. To reduce energy loss, inverter efficiency was increased by fine patterning of the Insulated Gate Bipolar Transistor (IGBT) chips, 12V DC-DC converter efficiency was increased by utilizing soft-switching, and the internal resistance of the IMA battery was lowered by modifying the electrodes and the current collecting structure. These improvements reduced the amount of heat generated by the unit components and made it possible to combine the previously separated Power Control Unit (PCU) and battery cooling systems into a single system. Consolidation of these two cooling circuits into one has reduced the volume of the newly developed IPU by 42% compared to the former model.

NMR STRUCTURE DETERMINATION OF A NOVEL CONOTOXIN, [Pro 7,13] $\alpha$A-conotoxin $P_{IVA}$

  • Han, Kyou-Hoon;Hwang, Kae-Jung;Kim, Seung-Moak;Kim, Soo-Kyung;William R. Gray;Shon, Ki-Joon;Jean Rivier;Baldomero M. Olivera
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 1996.07a
    • /
    • pp.10-10
    • /
    • 1996
  • High-resolution solution conformation of a novel conotoxin, [Pro 7,13] $\alpha$A-conotoxin $P_{IVA}$, GCCGSYPNAACHPCSCKDROSYCGQ-N $H_2$, has been determined by two-dimensional $^1$H nmr methods in combination with distance geometry calculation to rmsd values of 0.90 $\AA$ and 1.16 $\AA$ for the backbone and heavy atoms, respectively. Total of 324 NOE-derived interproton distance restraints including 33 long-range NOE restraints a well as 11 $\Phi$ and 7 $\chi$$^1$ torsion angle restraints were used for computation of structures. (omitted)d)

  • PDF

GROUP ACTIONS IN A UNIT-REGULAR RING WITH COMMUTING IDEMPOTENTS

  • Han, Jun-Cheol
    • East Asian mathematical journal
    • /
    • v.25 no.4
    • /
    • pp.433-440
    • /
    • 2009
  • Let R be a ring with unity, X the set of all nonzero, nonunits of R and G the group of all units of R. We will consider some group actions on X by G, the left (resp. right) regular action and the conjugate action. In this paper, by investigating these group actions we can have some results as follows: First, if E(R), the set of all nonzero nonunit idempotents of a unit-regular ring R, is commuting, then $o_{\ell}(x)\;=\;o_r(x)$, $o_c(x)\;=\;\{x\}$ for all $x\;{\in}\;X$ where $o_{\ell}(x)$ (resp. $o_r(x)$, $o_c(x)$) is the orbit of x under the left regular (resp. right regular, conjugate) action on X by G and R is abelian regular. Secondly, if R is a unit-regular ring with unity 1 such that G is a cyclic group and $2\;=\;1\;+\;1\;{\in}\;G$, then G is a finite group. Finally, if R is an abelian regular ring such that G is an abelian group, then R is a commutative ring.

Comparison between Labor Inputs by Quantity per Unit Method and by Actual Data Method in the Apartment Housing Construction Work - Focusing on Masonry Plaster Waterproofing Tile Labors - (공동주택 건설공사의 표준품셈과 실투입 노무량 비교 분석 - 미장, 방수, 조적, 타일공사를 중심으로 -)

  • Jeon, SangHoon;Koo, Kyo-Jin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.1
    • /
    • pp.110-118
    • /
    • 2015
  • The standard production unit system is the most basic element in our country construction. However, this standard production unit system shows a large difference in the actual amount of labor input for works at the Apartment housing construction, Therefore, it may be a reasonable alternative to estimate the cost of construction by historical cost data, works will be calculated the cost of labor must determine the exact amount and It is necessary to determine the exact amount of labor input for the construction progress management. This study examines the results of comparing the standard production unit system and the actual amount of labor counting in apartment housing construction was completed in the metropolitan area since 2000, the following results were obtained. the actual amount of labor input are looked for 1.184person/1000 of masonary, $0.084persons/m^2$ of plaster, $0.039persons/m^2$ of Waterproofing, $0.059persons/m^2$ of tile at the Apartment housing construction. in the actual amount of labor counting Compared with standard production unit system, masonry ratio of 59.8%, plaster ratio of 41.3%, waterproofing ratio of 31.5%, tile ratio of 34.3% and The labor rate in the works was the lowest in the plaster. was relatively high in the masonary. Therefore, the amount of labor country apartment housing construction is preferably calculated on historical cost data. But it seems that the amount of labor necessary complement ongoing close enough to the actual standard production unit system a major variable in construction management.

Pig slurry treatment by the pilot scale hybrid multi-stage unit system (HMUS) followed by sequencing batch reactor (SBR) (HMUS와 SBR 반응조를 이용한 축분처리에 관한 연구)

  • Lee, Young-Shin;Han, Gee-Bong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.2
    • /
    • pp.63-70
    • /
    • 2013
  • Experiments in a pilot-scale hybrid multi-stage unit system (HMUS) combination of ATAD and EGSB followed by SBR process for pig slurry treatment were conducted to demonstrate the feasibility of using autothermal thermophilic aerobic digestion (ATAD) and expended granular sludge bed (EGSB) followed by sequencing batch reactor (SBR) system. Contaminants in pig slurry with high organic matter, nitrogen (N) and phosphorus (P) content were completely removed in the combined process. The highest removal rate for CODcr among contaminants in the feed pig slurry was attained by about 43.3% in ATAD unit process. Also TS removal rate of 96.5% was attained and the highest in the next coagulation unit process. The highest removal rate of CODcr under operating parameter conditions of OLR(organic loading rate), 3-6Kg $COD/m^3{\cdot}day$ and line velocity, 1.5-4m/h was earned at 3days of HRT. The disinfection of pathogens was effective at 50,000mg/L of TS in ATAD unit process. Biogas production per organic removal was $2.3{\sim}8.5m^3/kgTS{\cdot}d$ (average $5.2m^3/kgTS{\cdot}d$) in EGSB unit process. The average removal rates of CODcr 71.7%, TS 64.1%, TN 45.9%, and TP 50.4% were earned in the intermittent aeration SBR unit process.

Development of a new Li-Ion Pack-Battery for improving the electrical properties (전기적인 특성향상을 위한 리튬이온전지팩 개발)

  • Gang, Young-Gu;Kweon, Hyun-Kyu;Seo, Myung-Su;Park, Chang-Yong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.2
    • /
    • pp.90-95
    • /
    • 2009
  • This paper presents a new lithium ion unit-cell and pack battery by using a new formulation ratio of material. The three types of formulation ratio for the unit-cell were used. The life cycle and basic properties of the lithium ion unit-cell$({\Psi}18{\times}65(mm))$ about one of them were acquired by the charge-discharge experiment. The nominal voltage, nominal capacity and cycle life output of the lithium ion unit-cell is respectively 3.7V, 2.4Ah, and above 500cycle. Pack type lithium ion battery has the size of $29.5{\times}73.5{\times}115(mm)$ and the weight of 300g. As the results, the weight and bulk of lithium ion battery used to a safety lamp were decreased to 1/4 and 1/7. In addition, the comparison of the new lithium ion battery and lead storge battery for confirming the effectiveness of the new lithium ion battery have been performed.

  • PDF

Depigmenting Effects of Esculetin and Esculin Isolated from Fraxinus rhynchophyllaHance (물푸레나무로부터 분리된 Esculetin와 Esculin의 미백 효능)

  • Hong, Yong Deog;Nam, Mi Hee;Lee, Chang Suk;Shin, Song Seok;Park, Young Ho
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.1
    • /
    • pp.89-94
    • /
    • 2014
  • Stem bark extracts of Fraxinus rhynchophylla Hance were found to contain two major bioactive components, esculetin and esculin. Esculetin substantially inhibited melanogenesis in B16F10 melanoma cells, with an $IC_{50}$ value of $2.8{\mu}M$, and reduced melanin synthesis in Melan-A cells. Moreover, esculetin suppressed melanin biosynthesis by inhibiting mushroom tyrosinase activity, with an $IC_{50}$ value of $40{\mu}M$. Taken together, these results suggest that esculetin could serve as an effective skin-lightening agent that inhibits melanin production by regulating the activity of melanogenic enzymes.

A Study on the Characteristics of he Space Composition of the Medium Large Size Apartments' Unit Plan in Gyeongnam (경남지역 중대형 아파트의 단위세대 평면구성 특성에 관한 연구)

  • Han, Min-Jeong
    • Journal of the Korean housing association
    • /
    • v.19 no.5
    • /
    • pp.1-10
    • /
    • 2008
  • This study attempts to analyze the characteristics of the space composition of the apartments and the general principles of apartments unit plans in Gyeongnam. Literature review and content analysis method were used in his research. The data of 108 unit plans were collected from e-catalogue and model houses of housing construction firms. The results of this study were as follows; 1) The general principle of Gyeongnam apartment unit plans, the tendency of 4LDk+2BATH type, 4bay, central type living room were showed. 2) In the point LDK and couple's bed room, LDK area become large and open type and couple's bed room were showed bed room+dress+powder+bath type as Maser's zone. 3) The entrance has a intermediate space as a balcony or a former space and the privacy of LDK space was protected from the entrance. 4) In the case of support space, generally support kitchen and laundry space were offered and several balconies were utilized. In fact, he differences of apartment plan composition between central cities and Gyeongnam were no showed. Therefore, these tendencies on plan composition of apartment in Gyeongnam were followed the general principles of Korean unit plans.

Structure and Antibiotic Activity of a Porcine Myeloid Antibacterial Peptide, PMAP-23 and its Analogues

  • Shin, Song-Yub;Kang, Joo-Hyun;Jang, So-Yun;Kim, Kil-Lyong;Hahm, Kyung-Soo
    • BMB Reports
    • /
    • v.33 no.1
    • /
    • pp.49-53
    • /
    • 2000
  • PMAP-23 is a 23-residue antimicrobial peptide derived from porcine myloid cells. In order to investigate the effects of two Pro residues at positions 12 and 15 of PMAP-23 on antibiotic activity, two analogues in which Ala was substituted for Pro residue at position 12 or 15 were synthesized. $Pro^{12}{\rightarrow}Ala$ (PMAPl) or $Pro^{15}{\rightarrow}Ala$(PMAP2) substitution in PMAP-23 caused a significant reduction on antitumor and phospholipid vesicle-disrupting activities, but did not cause a significant effect on antibacterial activity. PMAP-23 displayed the type I ${\beta}-turn$ structure with a negative ellipticity at near 205 om in SDS micelle, whereas PMAP1 and PMAP2 had a somewhat ${\alpha}-helical$ propensity in TFE solution, as compared to PMAP-23. These results suggest that two Pro residues of positions 12 and 15 in PMAP-23 play important roles in the formation of ${\beta}-turn$ structure on lipid membrane and its ${\beta}-turn$ structure may be essential for antibiotic activity including phospholipid vesicle-disrupting property.

  • PDF

Analysis on the Effect of Local Climate on the Unit-type Ground Heat Exchanger (지역 기후가 유닛형 지중열교환기 성능에 미치는 영향)

  • Bae, Sangmu;Kim, Jae-Min;Nam, Yujin
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.1
    • /
    • pp.67-76
    • /
    • 2019
  • A ground source heat pump (GSHP) system can stable system operation by using underground heat source and has high reliability for energy production. However, wide-spread of the GSHP system is delayed to high initial investment costs. In previous studies, horizontal and unit-type ground heat exchanger (GHX) have developed to overcome disadvantages such as high initial cost. However, these performances of GHXs are greatly influenced by climate and weather conditions. It is necessary to analyze the performance of GHX according to the ground temperature change in the installation site. In this study, the ground temperature of each installation site confirmed and performance of unit-type GHX quantitatively analyzed by numerical analysis. As the result, the performance of the unit type GHX was 33.9 W/m in Seoul, 34.2 W/m in Daejeon, and 37.2 W/m in Busan.The result showed the difference performance of GHX according to local climate was maximum of 9.7%.