• Title/Summary/Keyword: 형광분석

Search Result 1,201, Processing Time 0.026 seconds

Chemometric Analysis of 2D Fluorescence Spectra for Monitoring and Modeling of Fermentation Processes (생물공정 모니터링 및 모델링을 위한 2차원 형광스펙트럼의 다변량 분석)

  • Kang Tae-Hyoung;Sohn Ok-Jae;Kim Chun-Kwang;Chung Sang-Wook;Rhee Jong-Il
    • KSBB Journal
    • /
    • v.21 no.1 s.96
    • /
    • pp.59-67
    • /
    • 2006
  • 2D spectrofluorometer produces many spectral data during fermentation processes. The fluorescence spectra are analyzed using chemometric methods such as principal component analysis (PCA), principal component regression (PCR) and partial least square regression (PLS). Analysis of the spectral data by PCA results in scores and loadings that are visualized in score-loading plots and used to monitor a few fermentation processes by S. cerevisae and recombinant E. coli. Two chemometric models were established to analyze the correlation between fluorescence spectra and process variables using PCR and PLS, and PLS was found to show slightly better calibration and prediction performance than PCR.

Recent Progress in Multiplexed Detection of Biomarkers Based on Quantum Dots (양자점 기반 다중 바이오마커 검출법의 연구동향)

  • Kim, Yerin;Choi, Yu Rim;Kim, Bong-Geun;Na, Hyon Bin
    • Applied Chemistry for Engineering
    • /
    • v.33 no.5
    • /
    • pp.451-458
    • /
    • 2022
  • Semiconductor quantum dots (QDs) are optical probes with excellent fluorescence properties. Therefore, they have been applied to various bio-medical imaging techniques and biosensors. Due to the unique optical characteristics of wide absorption and narrow fluorescence energy bands, multiple types of signals can be generated by the combination of fluorescence wavelengths from different QDs, which enables the simultaneous detection of more than two biomarkers. In this review, the advantages and applications of QDs and QD nanobeads (QBs) in multiple biomarker assays were described, and new developments or improvements in multiplexed biomarker detection techniques were summarized. In particular, recent reports were summarized, focusing on the design strategies in immunoassay construction and signal transducing materials for fluorescence-linked immunosorbent assays using QDs and immunochromatographic assays using QBs. New detection platforms will be developed for early diagnosis of diseases and other fields if multiplexed detection technologies of excellent accuracy and sensitivity are combined with artificial intelligence algorithms.

양전자 소멸 측정법에 의한 형광물질의 결함 연구

  • Lee, Jong-Yong;Gwon, Jun-Hyeon;Bae, Seok-Hwan
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.45.1-45.1
    • /
    • 2009
  • 본 연구에서는 BaSrFBr:Eu 형광물질의 결함 농도 분석을 시도하였다. 또한 동시 계수 방법과 Fast -Slow - Coincidence 시스템으로 구성한 양전자 수명 측정법을 통하여 에너지의 변화에 따른 양성자 조사에 의한 시료 결함에 따른 동시 계수 도플러법과 양전자 수명의 변화를 측정 하였으며, SRIM 시뮬레이션을 통한 에너지에 따른 양성자 투과 깊이의 변화를 연구하였다.

  • PDF

차세대 광원 LED 응용을 위한 형광체 기술 현황

  • Kim, Yeong-Guk;Park, Yeong-Jo
    • 기계와재료
    • /
    • v.21 no.2
    • /
    • pp.110-118
    • /
    • 2009
  • 최근 유력한 차세대 광원으로 떠오르고 있는 발광 다이오드(LED, light emitting diode)는 화합물 반도체의 특성을 이용해 전기를 자외선, 가시광선, 적외선 등으로 전환시키는 반도체 소자로 에너지 효율이 매우 높고, 수명이 길어 교체 비용이 적으며, 진동이나 충격에도 강하고, 수은 등 유독물질의 사용이 불필요하기 때문에 에너지 절약, 환경보호, 비용절감 차원에서 매우 유리하다. 현재 LED 분야에 있어 주로 연구개발이 진행되고 있는 분야는 조명용 백색 LED 분야 및 디스플레이 소자 분야이다. LED를 이용한 백색 조명 및 디스플레이 기기의 개발을 위해서는 그 응용 분야에 맞는 효율이 우수한 형광체의 개발이 필수적이다. 본고에서는 현재 조명용 백색 LED 및 디스플레이 분야에 응용되는 형광체의 개발 현황을 위해 주로 연구동향을 분석하였다.

  • PDF

Dyeing of Cotton Fabrics with Loess Using Soybean Milk - The Compositions of Loess Deposited on the Cotton Fabrics - (콩즙을 이용한 면직물의 황토염색 -면직물에 부착된 황토의 성분분석을 중심으로-)

  • Kim, Soo-Jung;Ryu, Hyo-Seon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.10
    • /
    • pp.1770-1778
    • /
    • 2001
  • 황토는 대표적인 천연 무기염재의 일종으로서 바람에 의해 운반되어 퇴적된 담황색 내지는 황회색을 띠는 실트질의 퇴적물을 일컫는다. 황토의 구성물질은 주로 석영, 장석, 산화철광물, 깁사이트 등의 여러 가지 점토광물을 포함하는데, 주로 적색을 띠는 것은 소량의 산화철 광물에 기인되는 경우가 많으며 황토를 구성하는 점토광물로는 버미큘라이트, 카오린 광물인 캐올리나이트와 할로이사이트, 일라이트 등이 있다. 본 연구에서는 면직물에 천연 무기염재인 황토를 사용한 염색시에 황토 단독염색과 콩즙 전처리 후 황토염색으로 나누어 염색을 실시하고, 원료 황토와 황토염색 후 면직물에 부착된 성분 간에 차이가 있는지를 확인하기 위해 X선 형광분석(X-ray fluorescence analysis, XRF)을 이용하여 염색 전.후 황토의 성분을 분석하였고, X선 회절분석(X-ray diffraction analysis, XRD)을 이용하여 황토 및 염색 전 후 면직물에 부착된 광물질의 주성분을 분석하였으며, energy dispersive spectrometer (EDS)가 장착된 주사전자현미경을 이용하여 면직물에 부착된 광물의 성분을 조사하였다. 그 결과, 황토로 면직물을 염색하는 경우 면직물에 부착되는 황토의 양과 K/S 값은 거 의 비례하여 증가하는 것으로 나타났다. 황토 염색 후 면직물에 부탁되는 주성분은 주로 SiO$_2$, A1$_2$O$_3$, Fe$_2$O$_3$등인 것으로 나타났으며, X선 회절분석과 EDS분석에 의해 캐올리나이트, 일라이트 등의 점토광물의 형태로 존재하는 것이 확인되었다.

  • PDF

A Non-Linear Characteristics Modeling of High Frequency FL Lamp by Experimental Values (실험식을 이용한 고주파 형광램프의 비선형특성 모델링)

  • 함중걸;백수현
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.2
    • /
    • pp.51-55
    • /
    • 1997
  • The high frequency fluorescnet lighting systems are widely used because of their high luminous efficacy. However, the performance of the fluorescnet lamp at high frequency reveals significant changes depending upon operating frequency, lamp shape, lamp voltage and current while adapting either an electronic or an magnetic ballast. Therefore the matching between the fluorescent lamp and the ballast is the major concern in designing a lighting system. In this paper, high frequency characteristics of the FHF32W lamp is measured in a range of frequencies from 12kHz to 50kHz. And we presented a model of a fluorescnet lamp with non-linear impedance depending on the lamp current. Finally, after identifying the operating condition under negative imped¬ance behavior as lamp current changing, we proposed a method of choosing the optimal parameter of a high frequency fluorescnet lamp and the result is analyzed.

  • PDF

Corrosion Characteristics of Pumping-up Power Plant's Pipelines for Efficient Management (양수발전소 배관의 효율적 설계 및 관리를 위한 부식특성 연구)

  • Lee, Hun-Seong;Ra, Hye-Na;Gang, Jun;Kim, Gi-Jun;Mun, Gyeong-Man;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.05a
    • /
    • pp.224-224
    • /
    • 2009
  • 양수발전소의 파이프라인 부식에 대해 연구하였다. 파이프의 파공부위에 대한 외관구조분석, 녹 부위에 대한 SEM, XRD, X선 형광분석 및 모재부와 용접부의 전기화학적 분극을 측정하여 파이프라인의 파공과 부식에 대한 원인을 분석-고찰하고 최적의 관리방안을 제시하고자 하였다.

  • PDF

고감도 형광판을 이용한 실시간 IMRT 선량 분석 가능성 연구

  • 고영은;이병용;안승도;이상욱;김종훈;신성수;최은경
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.36-36
    • /
    • 2003
  • 목적 : 고감도 형광판과 필름을 이용하여 실시간으로 선량을 측정하여 IMRT 선량분포를 검증하는데 사용하는 가능성을 알아보고자 하였다. 대상 및 방법 : 본 연구에서 개발한 물팬텀은 지름 25cm 아크릴 원통과 원통의 중앙부분에 삽입되는 고감도 형광판으로 구성되어 있다. 이를 사용하여 dose linearity correction factor를 구하기 위해 dmax 지점에서 6MV x-ray를 고감도형광판에 조사하여 blurring correction factor를 구하였다. CCD를 이용하여 고감도 형광판에서 나오는 영상을 수집하였다. 고감도 형광판에서 수집한 영상의 x축 profile은 RTP에서 얻은 profile과 비교하였고, 이온전리함으로 scanning한 데이터를 이용하여 고감도 형광판과 물에서 빛에 의한 산란선 때문에 발생하는 blurring effect를 교정하였다. 여기서 계산된 blurring effect factor를 고감도 형광판에서 수집된 영상에 적용하였다. 결과 : CCD 카메라는 형광판의 전 영역을 감지할 수 있고, 조사시간은 형광판의 중첩된 영상의 선량에 비례하였다. 물팬텀에서 형광판의 blurring effect 는 가우시안 분포로 표현할 수 있었다. 또한 Deconvolution kernel은 원통 팬텀에서 지름 $\pm$5cm 이내의 범위에 위치하였고, 따라서 형광판 영상으로부터의 실제 선량분 포를 뽑아낼 수 있었다. RTP 에서 계산된 선량분포와 blurring correction factor로 교정한 후 중첩시켜 얻은 고감도 형광판 영상의 선량분포는 일치하였다. 결론 : 정기적인 IMRT 선량 검증에 대한 실시간 선량측정 방법이 개발되었다. 고감도 형광판 영상과 CCD 카메라를 사용한 물팬텀으로, IMRT 치료계획에 대한 선량분포를 검증할 수 있는 가능성을 보였다.비의 회전에 의한 오차 보정, 필름의 광학적 밀도에 관한 보정 등 여러 가지 계통적 오차들에 대한 보정들이 선량분포 확인과정의 이해와 그 기준마련에 도움이 되겠지만 우리가 다룬 원점 불일치에 비해서 상대적으로 무시할 수 있었다. 마지막으로 선량분포 확인의 최종목표인 3 차원 선량분포 확인의 실제 적용을 위한 연구가 최적화 알고리듬을 이용하여 실험 중에 있다.\times$5cm, 10$\times$10cm, 15$\times$l5cm, 20$\times$20cm인 경우, 측정하여 얻은 PSF가 0.8%, 0.2%, 0.4%, 0.2%로 약간 높지만, 두 값은 매우 유사한 것으로 나타났다. 그리고, 기존의 BSF를 이용해 구한 TAR과 BJR 25에서 권고하는 PSF를 이용해 구한 TAR을 비교한 결과 field size 에 따라 약 1%-1.5% 정도로 BSF를 이용하여 구한 TAR보다 PSF를 이용하여 구한 TAR이 1.3% 정도 높게 나타났지만, 이것은 두 값의 절대적인 차이일 뿐, 실제로는 PSF를 이용하여 구한 TAR이 측정해서 구한 TAR과는 매우 유사한 값을 보여주고 있다. 결론 : 기존의 BSF를 이용해 구한 TAR과 PSF를 이용해 구한 TAR을 비교하였을 때, 약 1.3% 정도 높게 내고 있지만, 기존의 TAR보다는 PSF를 이용해 구한 TAR이 BJR 25와 잘 일치하고 있으므로 Co-60 원격치료용 방사선 조사장치를 사용할 경우 BSF보다는 PSF를 사용하는 것이 타당한 것으로 사료된다.tokines의 변화는 비록 통계학적인 차이는 없지만 비타민 C를 사용한 환자의 cytokines이 모두 사용하지 않은 환자에 비해 감소하였음을 보였다. 비타민 C는 부작용이 거의 없는 안전한 약으로서 말기 암 환자에서 비타민 C사용은 임상 증상을 호전시키는 데 도움

  • PDF

A Study on the Luminescence Properties of Eu3+ Ions Doped Vanadate (Eu3+ 이온이 첨가된 바나듐산염의 형광특성 연구)

  • Kang, Yeonhee;Yoon, Changyong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.445-451
    • /
    • 2019
  • The fluorescence intensity and fluorescence lifetime of $Ba_2GdV_3O_{11}$, a vanadate compound based on $Ba^{2+}$ ion, were investigated by adding $Eu^{3+}$ as a rare earth ion which is an alkaline earth metal, which is distributed around active ions and has a large influence on fluorescent properties when used as a host in a phosphor. $Ba_2GdV_3O_{11}:Eu^{3+}$ phosphor was synthesized by solid state method and the crystallinity of the phosphor was confirmed by X - ray diffraction analysis. The fluorescence properties of the $Ba_2GdV_3O_{11}:Eu^{3+}$ phosphor were measured using optical and laser. The energy transfer and diffusion of the $Ba_2GdV_3O_{11}:Eu^{3+}$ phosphor are highly dependent on the concentration of $Eu^{3+}$. When the concentration of $Eu^{3+}$ is low, it shows strong fluorescence to the CT band. However, as the concentration of $Eu^{3+}$ increases, the fluorescence due to 4f - 4f transition is strong. The concentration of $Eu^{3+}$ ion increased and the energy between ions was diffused, and the lifetime of fluorescence decreased. Energy transfer occurs between two $Eu^{3+}$ ions at low $Eu^{3+}$ concentration and energy diffusion occurs at high $Eu^{3+}$ concentration.