Study on Adhesive Strength of Polymer Modified Cement Mortar for Maintenance in Concrete Structure (콘크리트 구조물 보수용 폴리머시멘트 모르타르의 부착강도 특성에 관한 연구)

  • Park, Sang-Soon;Kim, Jung-Heum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.5
    • /
    • pp.128-135
    • /
    • 2010
  • Polymer-modified cement mortar(PCM) has been widely used for strengthening of the concrete structures due to its excellent physical properties such as high strength and durability. Adhesive strength or behavior, on the other hands, between PCM and concrete is very important in strengthening the concrete member using PCM. Therefore the adhesive failure mechanism between PCM and concrete should be fully verified and understood. This study was performed to evaluate adhesive strength of PCM to the concrete by the direct pull-out test. In the direct pull-out tests, the adhesive strength under the various pre-treatment conditions such as immersion, thunder shower, freezing and thawing are evaluated. Also, the field direct pull-out test are performed to investigate the adhesive strength of mock-up test specimens. In the results of the test, the adhesive strength value by field test are lower than those of the standard curing condition. From these comparison and investigation, field test result was similar with the thunder shower test result. The results of the test was used to evaluate the korean industrial standard of polymer modified cement mortars for maintenance in concrete.

Study on the fault current test of HVDC thyristor valve (전류형 HVDC Valve의 단락시험에 대한 연구)

  • Lee, Jin-Hee;Kwon, Jun-Bum;Baek, Seung-Taek;Yun, Ji-Ho;Lee, Wook-Hwa;Chung, Yong-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.81-82
    • /
    • 2013
  • HVDC 시스템은 초고압 직류 송전 시스템으로써, AC를 DC로 변환하여 장거리 송전에 유리한 시스템이다. 현재 대륙간 송전 및 주파수 변환을 위한 BtB Topology에 많이 응용되고 있다. HVDC 시스템의 장점은 일정 송전거리 이상이 되면, DC가 AC에 비하여 손실율이 적고 유리한 장점이 있다. 해당 HVDC Valve는 전력을 AC-DC-AC로 변환하려면, HVDC Valve(Module)이라고 불리는 전력 변환 장치가 필수적이다. 해당 Valve를 현장에 설치하기 전에 IEC 60700-1 또는 CIGRE 같은 국제 표준 규격에 맞추어 Type Test를 진행 후에 통과 시 현장에 설치되어야 한다. 해당 Type Test는 크게 2가지로 분류되며, 절연 성능을 시험하기위한 Dielectric Test 그리고, 실제 Thyristor Valve의 동작을 가혹 한 조건에서 시험하기위한 Operational Test가 필요하다. 본 논문은 IEC 규격 (IEC 60700-1)에 의거 사이리스터 밸브에 대한 Operational Test 중 단락시험방법과 시험내용을 기술하고, 시험결과로 검증한다.

  • PDF

The Implementation of the Asymmertic Digital Subscriber Lines ( ADSL ) Interface Function in ATM Networks (ATM망에서 ADSL 정합장치 기능 구현)

  • So, Woon-Seob;Yang, Seong-Mo;Kim, Jin-Tae;Gang, Seok-Yeol
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.4
    • /
    • pp.1014-1024
    • /
    • 1998
  • This paper describes the implementation of the asymmetric digital subscriber lines(ADSL) interface device function in ATM networks. The function of the ADSL interface devices has been achieved within a type of the ATM switch standard board. The board connected with the ADSL modem process the ATM physical layer function of data transfering asymmetrically. For the implementation of the board, we have modeled a worst case of the subscriber line conditions from the existing investigated results on the impairments such as crosstalk, impulse noise, and some important noises loaded to subscrber line. Also we have performed assessment tests in the full test environments. We have found that the board is met to the standard specification in condition with various test loops and the worst line conditions using an ADLS line simulator. And we confirmed that high-speed multimedia services are performed well with the ATM switch and the ADSL subscriber line. It is evaluted that this board can be used for high quality ADSL services through existed copper subscriber line.

  • PDF

Scale Effects and Field Applications for Continuous Intrusion Miniature Cone Penetrometer (연속관입형 소형콘관입시험기에 대한 크기효과 및 현장적용)

  • Yoon, Sungsoo;Kim, Kyu-Sun;Lee, Jin Hyung;Shin, Dong-Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2359-2368
    • /
    • 2013
  • Cone penetration tests (CPTs) have been increasingly used for site characterizations. However, the site investigations using CPTs are often limited due to soil conditions depending on the cone size and capacity of the CPT system. The small sectional area of a miniature cone improves the applicability of the CPT system due to the increased capacity of the CPT system. A continuous intrusion system using a coiled rod allows fast and cost effective site investigation. In this study, the performance of the continuous intrusion miniature cone penetration test (CIMCPT) system has been evaluated by comparison tests with the standard CPT system at several construction sites in Korea. The results show that the CIMCPT system has a same performance with the CPT system and has advantages on the mobility and applicability. According to field verification tests for scale effect evaluation, the cone tip resistance evaluated by CIMCPT overestimates by 10% comparing to standard CPTs. A crawler mounted with the CIMCPT system has been implemented to improve accessibility to soft ground, and has shown improvement over the truck type CIMCPT system. Therefore, the improved CIMCPT system can be utilized as a cost effective and highly reliable soil investigation methodology to detect the depth of soft ground and to evaluate soil classification.

Estimation of End Bearing Capacity of SDA Augered Piles on Various Hearing Stratums (지지지반의 종류별 SDA매입말뚝의 선단지지력 산정)

  • Hong, Won-Pyo;Chai, Soo-Geun
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.5
    • /
    • pp.111-129
    • /
    • 2007
  • The standard construction manual of the SDA(Separated Doughnut Auger) piling method was proposed so that the resisting capacity of the augered piles could work effectively. 405 dynamic pile load tests and 30 static pile load tests were performed for 265 test piles, which were installed by the SDA piling method in 33 sites in Korea. The results of the pile load tests showed that the end bearing capacity of the SDA augered piles depended on the property of various soil stratums and did not agree with ones estimated by the existing formula based on several standard design codes. On the basis of the pile load test results, four formulas were presented according to bearing stratums to estimate quantitatively the unit end bearing capacity of the SDA augered piles. The formulas for the unit end bearing capacity of piles on soils or weathered rocks were related to N-value given by SPT(Standard Penetration Test), while the unit end bearing capacity on bedrock was suggested to be more than 1500 $tf/m^2$. The presented formulas were compared with the existing formulas, which were presented by several standard design codes to design the augered piles. In order to use correctly the presented formulas, the quality of Standard Penetration Test should be controlled precisely. Also it is desirable to choose a pilot construction site, where both dynamic and static pile load tests are performed.

Study on Development of a Carton Box for Cold-chain Distribution of Chinese Cabbage (저온유통용 배추 포장상자 개발에 관한 연구)

  • Lee, W.O.;Yun, H.S.;Lee, D.H.;Chung, H.;Cho, K.H.;Kim, M.S.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.02a
    • /
    • pp.329-334
    • /
    • 2003
  • 배추의 포장상자를 예냉ㆍ저온유통에 적합한 구조로 개선하기 위하여 3-4포기용 골판지 상자를 T11형 표준 팔레트에 적재율이 96%이상 되게 제작하여 고습조건에서도 안전하게 배추를 보호할 수 있는 상자구조를 찾기 위한 수직압축강도시험과 냉각성능 및 예냉후 품질 변화에 대한 시험을 실시하였다. 가. 배추의 저온유통에 사용하는 골판지포장상자는 개공율을 5.4%로 하고, 포장상자 형태를 접음식 형태로 하는 것이 예냉속도 및 예냉균일도에서 유리하고, 저장후 수직압축강도에서는 브릿스박스에 비하여 낮게 나타났지만, 안전압축강도 이상의 압축강도를 나타내었고 제작단가도 저렴하였다. 나. 예냉 후 저장 중 품질변화는 배추 줄기의 절단력을 측정한 결과 개선된 포장상자에서 유통기한을 6-7일정도 연장시킬 수 있는 것으로 나타났다.

  • PDF

Design and Performance Tests of a Cryogenic Blower for a Thermal Vacuum Chamber (열진공 챔버용 극저온 블로워 설계 및 성능평가)

  • Seo, Heejun;Cho, Hyokjin;Park, Sungwook;Moon, Gueewon;Huh, Hwanil
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.11
    • /
    • pp.1008-1015
    • /
    • 2015
  • Thermal vacuum test should be performed prior to launch to verify satellites' functionality in extremely cold/hot temperatures and vacuum conditions. A thermal vacuum chamber used to perform the thermal vacuum tests of a satellite system and its components. A cryogenic blower is a core component of the gaseous nitrogen (GN2) closed loop thermal control system for thermal vacuum chambers. A final goal of this research is development of cryogenic blower. Design requirements of a blower are 150 CFM flow rate, 0.5 bara pressure difference, hot and cold temperatures. This paper describes the performance analysis of impeller by 1D, CFD commercial software, the design of the thermal protection interface between the driving part and the fluid part. The performance of the cryogenic blower is confirmed by test at the standard air condition and is verified by on the thermal vacuum chamber at the real operating condition.

A Study of a Pilot Test for a Blasting Performance Evaluation Using a Dry Hole Charged with ANFO (건공화 공법의 발파 성능 평가를 위한 현장 시험에 관한 연구)

  • Lee, Seung Hun;Chong, Song-Hun;Choi, Hyung Bin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.2
    • /
    • pp.197-208
    • /
    • 2022
  • The existence of shallow bedrock and the desire to use underground space necessitate the use of blasting methods. The standard blasting method under water after drilling is associated with certain technical difficulties, including reduced detonation power, the use of a fixed charge per delay, and decoupling. However, there is no blasting method to replace the existing blasting method. In this paper, a dry hole charged with ANFO blasting is assessed while employing a dry hole pumping system to remove water from the drill borehole. Additional standard blasting is also utilized to compare the blasting performances of the two methods. The least-squares linear regression method is adopted to analyze the blasting vibration velocity quantitatively using the measured vibration velocity for each blasting method and the vibration velocity model as a function of the scaled distance. The results show that the dry hole charged with ANFO blasting will lead to greater damping of the blasting vibration, more energy dissipation to crush the surrounding rock, and closer distances for the allowable velocity of the blasting vibration. Also, standard blasting shows much longer influencing distances and a wider range of the blasting pattern. The pilot test confirms the blasting efficiency of dry hole charged with ANFO blasting.

Study on Fire Performance of Stud Connectors (스터드커넥터의 내화성능에 관한 연구)

  • Kim, Sung-Bae;Han, Sang-Hoon;Choi, Seng-Kwan
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.59-66
    • /
    • 2009
  • This research aims to conduct a pilot study for the in-fire performance of headed studs, commonly used in composite structures over the world. The robustness of the shear studs in fire appears to be a key element to govern the composite behaviour after a sudden local instability developed in structures such as trusses and cellular beams. In order to experimentally evaluate the residual strength of studs in fire, the standard push-out test was modified for a half of the original set-up to be equipped with a furnace. The adjustments allow the steel section to have a 3-sided exposure against fire. Under the Standard ISO fire, the modified push-out tests under loading were conducted to identify the failure mechanism of the studs in relation to temperature developments.

FTTC/VDSL 가입자 전송기술

  • 임기홍;김기호;심창섭;임종대
    • Information and Communications Magazine
    • /
    • v.15 no.7
    • /
    • pp.169-179
    • /
    • 1998
  • 본 논문에서는 현재 연구 개발되고 있는 Fiber-to-the-curb / Very high-rate digital subscriber line(FTTC/VDSL) 시스템의 DAVIC 표준 가입자 전송 기술인 51.84 Mb/s 16-CAP (Carrierless AM/PM) 전송시스템 (downstream)과 1.62 Mb/s QPSK burst-mode TDMA 전송시스템 (upstream)및, 타이밍 복원회로 등의 동작 원리 및 구조를 간략하게 기술하였다. 본 논문은 FTTC/VDSL 전송시스템 개발을 위하여 전체시스템이 운영될 환경, 즉 채널에 대하여 기술한 후, 주어진 채널에 적합한 down-stream전송시스템 알고리즘 및 구조를 설명하였으며, 타이밍 복원 시스템을 기술하였다. FTTC/VDSL시스템은 네트워크의 한 개의 송수신부가 가입자 댁내의 여러 개의 set-top box와 데이터를 주고받는 점 대 다점 (point-to-multipoint) 구조로 이루어져 있으며, 따라서 역 방향 (upstream) 채널 데이터 전송을 위한 QPSK 전송시스템은 네트워크쪽의 QPSK 수신부가 가입자 댁내의 여러개의 QPSK 송신부를 서비스할 수 있게끔 시분할 다중접속 방식인 burst-mode TDMA전송방식으로 구현되었다. FTTC/VDSL 전송시스템은 DAVIC의 시스템 성능 요구조건을 만족하게 설계되었으며, 모든 기능은 디지털로 구현되었고 칩 구현을 위하여 각 기능의 VLSI 시스템 파라메타 들을 추출하고 성능 시험을 실시하였다.