Estimation of End Bearing Capacity of SDA Augered Piles on Various Hearing Stratums  

Hong, Won-Pyo (Dept. of Civil Eng., Chung-Ang Univ.)
Chai, Soo-Geun (Dept. of Civil Eng., Chung-Ang Univ.)
Publication Information
Journal of the Korean Geotechnical Society / v.23, no.5, 2007 , pp. 111-129 More about this Journal
Abstract
The standard construction manual of the SDA(Separated Doughnut Auger) piling method was proposed so that the resisting capacity of the augered piles could work effectively. 405 dynamic pile load tests and 30 static pile load tests were performed for 265 test piles, which were installed by the SDA piling method in 33 sites in Korea. The results of the pile load tests showed that the end bearing capacity of the SDA augered piles depended on the property of various soil stratums and did not agree with ones estimated by the existing formula based on several standard design codes. On the basis of the pile load test results, four formulas were presented according to bearing stratums to estimate quantitatively the unit end bearing capacity of the SDA augered piles. The formulas for the unit end bearing capacity of piles on soils or weathered rocks were related to N-value given by SPT(Standard Penetration Test), while the unit end bearing capacity on bedrock was suggested to be more than 1500 $tf/m^2$. The presented formulas were compared with the existing formulas, which were presented by several standard design codes to design the augered piles. In order to use correctly the presented formulas, the quality of Standard Penetration Test should be controlled precisely. Also it is desirable to choose a pilot construction site, where both dynamic and static pile load tests are performed.
Keywords
Augered pile; Cement milk; End bearing capacity of pile; EOID; Pile load test; Restrike; N-value;
Citations & Related Records
연도 인용수 순위
  • Reference
1 김정수 (2003), 화강풍화대 지반에 매입된 SIP말뚝의 지지력 평가에 관한 연구, 박사학위논문, 한양대학교, pp.161-165
2 채수근 (1997), SDA 매입말뚝 신공법 연구 및 적용성 검토서, pp.1-110
3 채수근 (2000b), 'SDA매입말뚝 신공법 -한국고속철도 3공구 평택고가 적용 사례 중심으로', 대한토목학회지, 제48권 제9호 pp. 54-62
4 홍원표, 한중근, 채수근 (2002), 'SDA매입말뚝의 마찰지지력', 대한토목학회 학술발표논문, 2002, pp.5-8
5 COPITA (2006), (社)コンクリート バイル 建設技術協會, Concrete Pile Installation Technology Association, 2006. 4. NO.39, pp.21-76
6 (社)コンクリート パイル 建設技術協會 (1994), 埋立み工法 施工 便覽, pp.13-182
7 한국지반공학회 (2003), 구조물 기초설계기준해설, pp.286-292
8 채수근 (2002), SDA 매입말뚝의 연직지지력 산정, 석사학위논문, 중앙대학교, pp.1-121
9 서울특별시 (1996), 지반조사 편람, pp.22-24
10 홍원표, 윤중만, 한중근 (1998), '매입말뚝의 지지력 특성', 한국지반공학회 '98 말뚝기초위원회 세미나논문집, 1998, pp.3-49
11 Chin, F. K. and Vail, A. J. (1973), 'Behavior of Piles in Alluvium', Proceedings of 8th International Conference on Soil Mechanics and Foundation Engineering, Moscow, Soviet Union, pp.47-52
12 채수근 (2000a), 'Q&A 매입말뚝 시공법', 한국지반공학회지, Vol.16, No.7, pp.63-68
13 임해식, 박용부, 박종배, 김정수, 한경렬, 김도형 (2001), SIP공법의 품질개선방안과 지지력 산정법 제안에 관한 연구, 대한주택공사 주택연구소, pp.68-79
14 Hong, Won-Pyo and Chai, Soo-Geun (2003), 'Skin Friction Capacity of Separated Doughnut Auger (SDA) Pile', The Proceeding of the 13th International Offshore and Polar Engineering Conference (ISOPE-2003), Honolulu, Hawaii, U.S.A, pp.740-745
15 대한건축학회 (2005), 건축기초구조설계기준, pp.172-184
16 대한주택공사 (1997), 표준시방서(건축) 30535 말뚝선굴착공법, pp.1-9
17 한국도로공사 (2006), SIP공법의 시공 및 설계 지침(안), 교통기술원, pp.1-26
18 Hong, Won-Pyo and Chai, Soo-Geun (2005), 'Bearing Capacity Characteristics of Separated Doughnut Auger (SDA) Pile in Clay and Silty Soil', The Proceeding of the 15th International Offshore and Polar Engineering Conference (ISOPE-2005), Seoul, Korea, pp.548-554
19 두성건설 (1987), SIP기초공법, pp.1-68
20 대한토목학회 (2001), 도로교 설계기준 해설, pp.207-313
21 津田 和義 (2003), 旣製 コンクリート杭 - 基礎構造設計 manual - 土木編, (社)コンクリート バイル 建設技術協曾, 附錄5-1-5-5. 'プレボーリング杭の設計と施工'
22 이원제 (2000), 광섬유센서를 이용한 매입말뚝의 하중전이 측정 및 지지력 특성 연구, 박사학위논문, 고려대학교, pp.114-121