• Title/Summary/Keyword: 폴리머애자

Search Result 110, Processing Time 0.035 seconds

The study on the performance test of a urban transit polymer insulator developed (도시철도용 폴리머 애자 개발품 성능시험에 대한 고찰)

  • Sim, Jae-Suk;Kim, Yeon-Sik;Kang, Hyun-Il;Lee, Gi-Seung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.78-78
    • /
    • 2010
  • Fiber Reinforced Plastic (FRP) insulator has a higher performance than porcelain. It is only used in domestic AC 25 kV electric railway system. Seoul Metro has developed DC 1500 V polymer insulator since 2008. The test of moisture infiltration is carried out. The test results showed that all result values satisfy the test standard.

  • PDF

Surface Discharge and Materials Analysis of Polymer Insulators Due to Accelerated Deterioration (가속열화에 의한 폴리머애자의 연면방전과 재료분석)

  • Shong, Kil-Mok;Kim, Jong-Min;Jung, Jin-Su;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1372-1373
    • /
    • 2008
  • This study investigated the detection of corona discharge on polymer insulators at 13.2kV. Also, It will be analyzed by variety analyzers such as FT-IR, TA, and so on. It carried out an experiment and an actual measurement about corona detection using a UV-camera. This experiment and inspection would need to respect the above criteria. It was required to verify various experimental conditions and on-site inspection afterwards, but it was believed to minimize the measurement error by data-basing research results in a continuous manner and it was necessary to establish diagnosis technologies and standards in various electrical power facilities.

  • PDF

Power Relief Characteristic of Polymer Arrester by Structure of Filament Winding (필라멘트 와인딩 구조의 폴리머 피뢰기 방압특성)

  • Huh, Chang-Su;Kim, Nam-Ryul;Lee, Ki-Taek;Suh, Tu-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.522-525
    • /
    • 2003
  • 기존 애자형 피뢰기의 문제점인 폭발 및 비산으로부터 보다 안전하여 최근 각광을 받고 있는 폴리머 피뢰기에서 필라멘트 와인딩을 망사형 구조로 제작하고 제작된 필라멘트에 실리콘 하우징을 단일 사출 성형한 구조로 시료를 제작하여 기밀특성 및 방압특성에 대해 검증하였다. 시험결과로 제시된 자료는 추후, 제품의 양산 및 현장 적용에 많은 도움을 줄 것으로 사료된다.

  • PDF

The Surface Characteristics of Silicone Rubber by Discharge Aging (방전열화에 의한 실리콘 고무의 표면특성 연구)

  • Kang, Dong-Pil;Park, Hoy-Yul;Ahn, Myeong-Sang;Lee, Hee-Woong;Kim, Dae-Whan;Ha, Min-Ja
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1437-1439
    • /
    • 2002
  • 실리콘 고무는 내열성, 내후성, 발수성, 내오염성, 내트래킹성 등이 우수하여 옥외절연물용의 외피 재료로 널리 사용되고 있다. 폴리머 애자에서 전기방전 (코로나, 트래킹 등)에 의한 외피표면의 발수성 저하가 절연물의 장기성능에 있어서 가장 중요한 인자들 중에 하나이다. 실리콘 고무에는 ATH가 다량 첨가되는데 ATH의 첨가량, 표면처리상태, 입도 등에 의해 실리콘 고무의 발수성과 발수성회복 특성은 다르게 나타난다. 본 논문에서는 입도가 다른 2종의 ATH를 선택하여 실리콘 폴리머 대비 ATH의 첨가량을 달리하여 실리콘 고무의 발수성에 관련한 특성을 조사하였다. ATH의 입도 및 코로나 처리시간에 따라서 접촉각의 변화를 관찰하였으며, 코로나 처리 후 경과시간에 따른 발수성의 회복특성을 접촉각의 측정을 통하여 조사하였다.

  • PDF

Reliability Assessment of Polymer Insulators for Power Distribution System using Characterization Techniques (특성분석 기법을 이용한 배전용 폴리머애자의 신뢰성 평가)

  • Han, Jae-Hong;Lee, Byung-Sung;Han, Yong-Heui
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2358-2360
    • /
    • 1999
  • This study describes the reliability assessment of 3 years-aged polymer insulators using polymer characterization techniques such as SEM, contact angle, DSC, FTIR. Two kinds of polymer insulators were dismounted from 5 fields. All polymer insulators showed the micro-cracks and the reduction of characteristic peaks on the shed surface. Contact angle was increased with time. Although some superficial changes have occurred, there are no significant changes in various properties. Comparison of dismounted insulators to new ones revealed that the field-aged insulators are reliable for the present.

  • PDF

Evaluation of Ageing Characteristics of Polymeric Insulators for Distribution Lines by Tracking Wheel Test (Tracking wheel 시험을 통한 배전용 폴리머애자 열화특성 평가)

  • Lee, Byung-Sung;Han, Jae-Hong;Han, Yong-Heui;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2314-2316
    • /
    • 1999
  • This study describes the results of aging characteristics of polymer insulators through the tracking wheel test. In order to evaluate the reliability of polymer insulators, 4 polymer insulators which used in the field were selected. Electrical tests such as power frequency voltage test, steep-front impulse voltage test were performed after tracking wheel test. Chemical structure and contact angle were measured for investigating an aging characteristics. Although some changes have occurred on the surface of insulator, there are no critical changes between new and tracking wheel tested insulator.

  • PDF

Reliability Assessment of Polymer Insulators by Accelerated Aging Test (가속열화시험에 의한 폴리머애자의 신뢰성 평가)

  • Han, Jae-Hong;Lee, Byung-Sung;Jung, Jong-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.10-14
    • /
    • 2001
  • In order to assess the long-tenn reliability of polymer insulators for distribution power systems, we have developed the accelerated aging test method which can simulate the operation conditions. In this study, 3000 hours aging test for 4 kinds of polymer insulators has been completed by the developed accelerated aging test. After 3000 hours aging test, visual inspection and electrical tests were carried for identifying a change of characteristics. Some specimens showed the surface erosion and the manufacturing defect. In the electrical tests, the wet flashover voltage was significant1y decreased by the accelerated aging test. In comparison with the field-aged polymer insulators, it can be concluded that the developed test method can evaluate the long-tenn reliability within short time and screen the manufacturing defect.

  • PDF

Characterization of Field-Aged Polymer Insulators for Distribution Power Systems (배전용 폴리머애자의 현장열화 특성평가)

  • 이병성;김찬영;한재홍
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.10
    • /
    • pp.847-858
    • /
    • 2000
  • The aging characteristics of 2 kinds of 3 years field-aged distribution polymer insulators which were dismounted from 5 regions have been investigated by electrical test and material characterization. Although the tan $\delta$of specimens prepared from weathershed was increased with surface aging, the tan $\delta$and leakage current of real products had no difference between virgin and dismounted ones. Due to the aging, all dismounted polymer insulators had micro-cracks on the surface of weathershed and only the products of manufacturer B showed the reduction of OIT(oxidation induction time). But, there were no differences between virgin and dismounted products in contact angle and chemical structure. Therefore, it can be considered that the aging is only limited on the surface of dismounted polymer insulators and that NMR technique are very useful to evaluate the aging of polymer materials.

  • PDF

A Combined Aging Test Facility for Evaluating an Aging Characteristics of Distribution Polymer Insulators (배전용 폴리머애자 열화특성 평가를 위한 복합열화 시험장치 구축)

  • Lee, Byung-Sung;Han, Jae-Hong;Kim, Chan-Young;Yoon, Tae-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1948-1950
    • /
    • 2000
  • Polymeric composite insulators have been in use for outdoor insulation. However, our knowledge about their long-term performance in an outdoor environment is still very limited. Especially, these insulators are subjected to the environmental stress such as ultraviolet radiation, electrical stress, mechanical load, etc.. Hence, in this paper, we simulated the factors having influence on aging of polymer insulators using the combined aging test chamber. In order to evaluate an aging characteristics with time, we measured leakage current on these insulators to make out the degree of aging.

  • PDF

Development of data acquisition and analysis program modules for leakage current of polymeric insulators using the Labview software (Labview를 이용한 배전용 폴리머애자의 누설전류 측정 및 분석 프로그램 개발)

  • Cho, Seong-Soo;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1969-1971
    • /
    • 2000
  • This paper presents a data acquisition and analysis program modules that has been developed using the Labview program. These program modules can use to acquire and analyze leakage current data of insulator under different contamination conditions. The experimental hardware made up salt fog chamber, AC/DC power supply, transducer (shunt resistor), measurement devices and PC with the GPIB (General Purpose Interface Bus). And analysis program modules can calculate pulse level count, accumulated charge, average leakage current, power spectrum, and harmonics. The result of applying these analytical program modules to polymeric insulator is available for evaluation of leakage current characteristic of outdoor insulators.

  • PDF