• Title/Summary/Keyword: 치조제 흡수

Search Result 77, Processing Time 0.025 seconds

Pulp and periodontal tissue changes following rapid tooth retraction by periodontal distraction in young adult dogs (유성견에서 periodontal distraction에 의한 급속 치아견인 시 치수 및 치주조직의 변화에 관한 연구)

  • Lee, Jong-Jin;Hong, Hyun-Sil;Chae, Jong-Moon;Jo, Jin-Hyung;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.37 no.5
    • /
    • pp.351-363
    • /
    • 2007
  • The aim of this study was to evaluate pulp and periodontal changes following rapid tooth retraction by periodontal distraction after bone undermining surgery in young adult dogs. Methods: Alter extraction of second premolars, the interseptal bone mesial to the upper 3rd premolar was undermined. After activating the distraction appliance at 0.5 mm/day for six days, the dogs were sacrificed at 0, 1, 3, 5, 7, and 9 weeks during the consolidation period. Tissue changes of periodontium and pulp were evaluated radiologically, histologically, and immunohistochemically. Results: Digital subtraction radiography showed active bone formation in the stretched periodontal ligament from 0 - 4 weeks. Resorption of the alveolar bone, appearance of osteoclasts, and infiltration of inflammatory cells were observed just after the activation period at the pressure side, and distinctive bone formation was seen in the tension side of the periodontal ligament from 1 week. New bone formation was active at 1 - 3 weeks. The expression of calcitonin gene-related peptide in the experimental group was increased at the alveolar bone and pulp, and periodontal ligament at the pressure side from 0 - 1 week, and it decreased after 5 weeks to become similar to that of the control group. Conclusions: The results showed that rapid tooth movement using periodontal distraction can be new form of orthodontic tooth movement for accelerating normal bone formation.

ECTOPIC ERUPT10N OF TRANSPOSED MANDIBULAR PERMANENT LATERAL INCISOR (이소 맹출한 하악 측절치의 교정적 치험례)

  • Lim, Hyun-Hwa;Kim, Yong-Soo;Jang, Ki-Taek;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.3
    • /
    • pp.438-443
    • /
    • 2000
  • Ectopic eruption should be understood as a change in the course of the normal eruption path of a dental bud at any moment its origin. An example of this alteration is the dental transposition, a rare and more specific dental anomaly that may be defined as a change of position between two teeth. This case shows ectopic eruption of transposed mandibular lateral incisor beneath primary first molar at the first transitional period of the mixed dentition The crown of the lateral incisor has tipped distally, compelling root resorption and exfoliation of the adjacent primary cuspid and primary first molar. The reason for such eruption is not clearly understood, but it may involve; (1)trauma history, (2)prolonged retention of the deciduous teeth, (3)premature exfoliation of the deciduous teeth, and (4)genetic factor. Treatment is divided into interceptive and definitive treatment. Ectopically erupting mandibular incisor tends to become transposed with the adjacent cuspid and thus seems to warrant early orthodontic intervention. Early treatment may obviate later extraction or transposition of the incisor and canine in the permanent dentition. Timing is an important factor to be considered regarding in the correction of the lateral incisor transposition. This case advocates treatment with an active orthodontic therapy at the early stage of the mixed dentiton, before the eruption of the permanent cuspid.

  • PDF

Full-mouth rehabilitation with implant-supported fixed dental prostheses for the edentulous maxilla and partially edentulous mandible: A case report (상악 완전 무치악 및 하악 부분 무치악 환자에서 임플란트 지지형 고정성 보철물을 이용한 전악 수복 증례 보고)

  • Kim, Tae-Hyung;Oh, Kyung-Chul;Moon, Hong-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.374-381
    • /
    • 2019
  • A conventional approach for the treatment of long-span edentulous areas is the use of removable dentures. However, placing implants in these areas results in superior functional outcomes by increasing the stability, support, and resistance of the prostheses and improving the masticatory efficiency. Treatment modalities utilizing implants can be further classified into either removable or fixed-type prostheses. Several factors such as the amount of alveolar bone resorption, inter-arch relationship, patient preferences, and socioeconomic status should be considered when determining the appropriate treatment approach. Monolithic zirconia has been considered a suitable material for implant-supported fixed dental prosthesis, because of the drastic improvement in its mechanical properties. It exhibits fewer incidences of fracture and chipping of the prostheses, and has greater bulk of material than metal-ceramic crowns and zirconia-veneered ceramics. Moreover, highly translucent monolithic zirconia is also available in the market, and its application is gradually increasing for anterior tooth rehabilitation. The present report describes a patient who underwent full-mouth rehabilitation with fixed dental prostheses (eight upper and three lower implant placements). All teeth, except bilateral mandibular canines and left mandibular first and second premolars, were extracted after the diagnosis of generalized chronic moderate-to-advanced periodontitis of the remaining teeth. The patient reported satisfactory esthetic and functional outcomes during the one-year follow-up visit.

The effects of tissue punch diameter on healing around implants in flapless implant surgery (무피판 임플란트 수술에서 연조직 펀치의 크기가 임플란트 주위 조직의 치유에 미치는 영향)

  • Lee, Du-Hyeong;Jeong, Seung-Mi;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.301-311
    • /
    • 2009
  • Statement of problem: Flapless implant surgery using a soft tissue punch device requires a circumferential excision of the mucosa at the implant site. To date, Although there have been several reports on clinical outcomes of flapless implant surgeries, there are no published reports that address the appropriate size of the soft tissue punch for peri-implant tissue healing. Purpose: In an attempt to help produce guidelines for the use of soft tissue punches, this animal study was undertaken to examine the effect of soft tissue punch size on the healing of peri-implant tissue in a canine mandible model. Material and methods: Bilateral, edentulated, flat alveolar ridges were created in the mandibles of six mongrel dogs. After a three month healing period, three fixtures (diameter, 4.0 mm) were placed on each side of the mandible using 3 mm, 4 mm, or 5 mm soft tissue punches. During subsequent healing periods, the peri-implant mucosa was evaluated using clinical, radiological, and histometric parameters, which included Gingival Index, bleeding on probing, probing pocket depth, marginal bone loss, and vertical dimension measurements of the peri-implant tissues. Results: The results showed significant differences (P <0.05) between the 3 mm, 4 mm and 5 mm tissue punch groups for the length of the junctional epithelium, probing depth, and marginal bone loss during healing periods after implant placement. When the mucosa was punched with a 3 mm tissue punch, the length of the junctional epithelium was shorter, the probing depth was shallower, and less crestal bone loss occurred than when using a tissue punch with a diameter $\geq$ 4 mm. Conclusion: Within the limit of this study, the size of the soft tissue punch plays an important role in achieving optimal healing. Our findings support the use of tissue punch that 1 mm smaller than implant itself to obtain better peri-implant tissue healing around flapless implants.

Comparison of the Strain on the Alveolar Ridge According to the Occlusal Scheme of Complete Dentures (총의치 교합양식에 따른 응력 분포 양상 비교연구)

  • Choi, Won-Jun;Lim, Young-Jun;Kim, Chang-Whe;Kim, Myung-Joo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.1-12
    • /
    • 2010
  • The purpose of this study was to compare the strain on the alveolar ridge in the centric, eccentric and protrusive position according to the occlusal scheme (bilateral balanced occlusion with 33 degree anatomical teeth, group B; monoplane occlusion with non-anatomical teeth, group M; lingualized occlusion with 33 degree anatomical teeth and non-anatomical teeth, group L; of complete dentures. Experimental dentures were set bilateral balanced occlusion, lingualized occlusion and monoplane occlusion. They are analysed through T-Scan II(Tekscan, Boston, U.S.A) and 1.5mm thick layer was removed from the denture-supporting surface of resin model and then replaced with silicone to simulate resilient edentulous ridge mucosa. A $4{\times}6$ linear strain gauge is attached to the $1^{st}$ premolar and $1^{st}$ molar area. The strain values are recorded according to the occlusal scheme in the centric, eccentric and protrusive position after uniformly applying 50 N and 150 N force through a Universal Testing Machine(instron$^{(R)}$ 5567, Bluehill 2.0 software ,U.S.A.) with the models mounted in the articulator. When performing centric and protrusive occlusion, the three groups of occlusal scheme were compared in the anterior region and in the posterior region. The strains of each group were also compared in the working side and in the non-working side during eccentric excursion. It was observed that the strain in the bilateral balanced occlusion showed a higher value than the lingualized occlusion and monoplane occlusion in every position except the non-working side. However, during the eccentric movement the strain value in the non-working side showed the lowest value in the bilaterally balanced occlusion. The strain change amount from the working side or centric occlusion to non-working side and also the strain variation rate within the non-working side showed the highest value in bilateral balanced occlusion.

MMP-1 and TIMP-1 production in MG-63 cells stimulated with Prevotella nigrescens Lipopolysaccharide (Prevotella nigrescens lipopolysaccharides로 자극된 MG63 세포에서 분비되는 기질금속단백질 MMP-1과 TIMP-1의 수준에 관한 연구)

  • Yang Won-Kyung;Kim Mi-Ri;Shon Won-Jun;Lee In-Bog;Cho Byeong-Hoon;Um Chung-Moon;Son Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.5
    • /
    • pp.470-478
    • /
    • 2004
  • The purpose of this study is to monitor the secretion of matrix metalloproteinase-1 (MMP-1) and tissue inhibitor of metalloproteinase-1 (TIMP-1) produced by human osteosarcoma cell line (MG63) stimulated with Prevotella nigrescens lipopolysaccharides (LPS). and to compare the level of secretion before and after the treatment of calcium hydroxide on P. nigrescens LPS. LPS was extracted and purified from anaerobically cultured P. nigrescens. MG63 cells were stimulated by the LPS (0, 1, $10{\;}\mu\textrm{g}/ml$) or LPS($10{\;}\mu\textrm{g}/ml$) pretreated with 12.5 mg/ml of $Ca(OH)_2$ for 3 days. Total RNA was isolated from the cell. and real-time quantitative polymerase chain reaction (PCR) was performed for quantification of MMP-1 and TIMP-1. The results were as follows. 1. MMP-1 mRNA expression at 48 hr was highly increased by stimulation with P. nigrescens LPS. The increase was dose-dependent. 2. When stimulated with ($1{\;}\mu\textrm{g}/ml$ of LPS. TIMP-1 mRNA expression was highly increased at 24 hr and 48 hr. However. TIMP-1 expression was suppressed at higher concentration ($10{\;}\mu\textrm{g}/ml$). 3. When P. nigrescens LPS was pretreated with $Ca(OH)_2$. MMP-1 and TIMP-1 gene expression was downregulated. The results of this study suggest that transcriptional regulation of MMP-1 and TIMP-1 by P. nigrescens LPS could be one of the important mechanisms in bone resorption of periapical inflammation. The result of calcium hydroxide on MMP-1 and TIMP-1 gene expression suppression shows that calcium hydroxide detoxified bacterial LPS and thus should be used the medication of choice for intracanal dressings in root canal infected with black-pigmented bacteria.

Effect of Mouthguard on Tooth Distortion During Clenching (이악물기 시 발생되는 치아변형에 대한 구강보호장치의 역할)

  • Lee, Yun;Choi, Dae-Gyun;Kwon, Kung-Rock;Lee, Richard Sung-Bok;Noh, Kwan-Tae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.405-417
    • /
    • 2010
  • Previous studies have already shown that mouthguard is effective in protecting jaw bone, teeth and oral tissue against sports trauma. However, other than severe trauma, repetitive force, such as disorders like clenching, cause teeth or oral tissue damage. These kinds of disorders usually present pathologic attrition in the posterior teeth, resorption in alveolar bone, loss of teeth and destruction of occlusion. Wearing a mouthguard is believed to be effective in preventing these disorders. But its effect is not examined thoroughly enough. The purpose of this study is to identify whether mouthguard is effective in reducing strain caused by clenching. Mandibular first molars in the normal occlusal relationship without any history of dental treatment were chosen. Biaxial type strain gauge was placed on the buccal surface of the tooth. Having maximum occlusal force, measured by load cell, as a standard, clenching intensity were divided into three stages; moment of slightly tooth contact, medium bite force (50% of maximum bite force), maximum bite force. Strain occurring in dentition in each stage with and without mouthguard was measured. Changes in strain (on dentition) between each stage and difference in strain, between with or without mouthguard were recorded by PCD-300 analyzer and PCD-30 soft ware. The data was statistically analyzed by Wilcoxon signed rank test. The following results were drawn; Without mouthguard, strain given on dentition increased as the clenching force increased. With mouthguard, strain given on dentition also increased as the clenching force increased. With mouthguard, strain decreased, in all cases of clenching force stages. Data on the moment of slightly tooth contact stage, had no statistical significance. However, with mouthguard, 50-90% of decrease in strain could be obtained in maximum occlusal force, compared to the group without mouthguard. Mouthguard decreased the strain on the dentition, caused by clenching. Therefore, mouthguard seems to be effective in preventing damage on dentition, by acting against clenching, which occurs both consciously and unconsciously during sports activities.