• Title/Summary/Keyword: 충전율

Search Result 436, Processing Time 0.024 seconds

The Strength of Square Steel Tubular Column to H-beam Connections - Focused on the connections with outside-type diaphragm - (각형강관 기둥 - H형강 보의 접합부 내력 평가 - 외측형 다이아프램 접합부를 중심으로 -)

  • Lee, Seong Do;Kim, Pil Jung;Kim, Kyu Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.1 s.68
    • /
    • pp.11-20
    • /
    • 2004
  • This paper focused on square steel tubular column to H-beam connections (concrete filled tubular) with an outside-type diaphragm. Based on the yield line theory and the nonlinear static FEM analysis the specification equations were evaluated by comparing them with previous result of the simplified tensile experiment[please check. The yield line theory applied to the mechanical model theory revised by K. Morita, the nonlinear static FEM analysis using abaqus/standard, the ultimate strength equation in the specification equation using the factor for long-time loading, and the yield ratio according to material. The allowable strength in the specification equations applied the safety factors of 2.2 and 2.6 in the cases with and without filled concrete, respectively. Therefore, the evaluation of strength(for the previous result of the simplified tensile experiment in this study) was considered possible through the yield line theory, the nonlinear static FEM analysis, and the specification equations. Likewise, the specification equations were seen to be an underestimate of the previous result of the simplified tensile experiment. The strength and displaced mesh in the FEM analysis approximated the previous result of the simplified tensile experiment.

Effect of Cathode/anode Weight Ratio in $LiCoO_2/MPCF$ Cell ($LiCoO_2/MPCF$전지에서 정$\cdot$부극 중량비의 영향)

  • Kim Sang-Pil;Cho Jeong-Soo;Kim Hee-Je;Park Jeong-Hu;Yun Mun-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.2
    • /
    • pp.75-80
    • /
    • 1999
  • Li-ion cells employ lithium transtion metal oxide as the cathode material and carbon as anode material. To manufacture Li-ion cell with higher capacity and better cycle life, the utilization of electrode materials should be as high as possible without lithium deposition onto the carbon surface during charging. A careful design of cell balance between cathode and anode materials as well as a proper charge method is a key factor to design Li-ion cell with long cycle life. In this study, we investigated the effect of cathode/anode weight ratio on the performance of $LiCoO_2/MPCF$ cell. First we evaluated the charge-discharge behaviours of half-cells. And cylindrical Li-ion cells were fabricated using graphitized MPCF anode and $LiCoO_2$ cathode. The voltage profiles for each half-cell in $LiCoO_2/MPCF$ cell were measured by using lithium metal as a reference electrode. Also, we evaluated the cyclic performance of $LiCoO_2/MPCF$ cells according to weight ratio. From the result of experiment $LiCoO_2$ cathode utilization was independent of weight ratio, but MPCF anode utilization was dependant on weight ratio. Also, the optimal weight ratio of $LiCoO_2/MPCF$ cell was found to be $2.0\~2.2$.

Prognostic factors influencing clinical outcome of nonsurgical endodontic treatment (비외과적 근관치료의 임상적 성공에 영향을 미치는 예측 인자들의 평가)

  • Kim, Seon-Ah
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.436-444
    • /
    • 2010
  • Objectives: This study aimed to assess prospectively the clinical outcome of nonsurgical endodontic treatment and identify patient- and tooth-related factors, rather than treatment-related factors, that were the best predictors of this outcome. Materials and Methods: The inception cohort comprised 441 teeth (320 patients) and 175 teeth (123 patients) were followed up for 1-2 years. Age, gender, presence of medical disease, number of canals, previous endodontic treatment, presence of sensitivity and pain, pulp vitality, swelling or sinus tract of pulpal origin on the gingiva, periapical radiolucency and tendency of unilateral bite on the affected tooth were recorded at treatment start. Results: The outcome was classified on the basis of periapical radiolucency as healed or non healed. The overall healed rate in these cases, including nonsurgical retreatment, was 81.1%. Four tooth-related factors had a negative impact in the bivariate analysis: previous endodontic treatment, necrotic pulp, preoperative gingival swelling or sinus tract of pulpal origin, and preoperative periapical radiolucency. Stepwise logistic regression analysis including patient-, tooth-related factors and level of the root canal filling as a treatment-related factor showed that preoperative gingival lesion (odds ratio [OR]: 4.4; p = 0.005), preoperative periapical radiolucency (OR: 3.6; p = 0.011), and $\leq$ 1-2 mm under root filling length (OR: 9.6; p = 0.012) were significant predictors of failure. Conclusions: A preoperative gingival lesion of pulpal origin can influence the outcome of nonsurgical endodontic treatment in addition to preoperative periapical radiolucency.

Demonstration Study on Ammonia Stripping in Electronic Industry Wastewater with High Concentrations of Ammonia Nitrogen (고농도 암모니아를 함유한 전자 폐수의 암모니아 탈기 실증 연구)

  • Jae Hyun Son;Younghee Kim
    • Clean Technology
    • /
    • v.29 no.4
    • /
    • pp.297-304
    • /
    • 2023
  • The rapid advancement of the high-tech electronics industry has led to a significant increase in high-concentration ammonia wastewater. Various methods have been attempted to reliably treat wastewater containing high concentrations of ammonia, but no successful technology has yet been developed and applied. In this study, the removal efficiency and characteristics of ammonia nitrogen was evaluated according to changes in temperature, air loading rate, and liquid loading rate using a closed circulation countercurrent packed tower type demonstration facility for wastewater containing high concentrations of ammonia generated in the high-tech electronics industry. The temperature was varied while maintaining operating conditions of a wastewater flowrate of 20.8 m3 h-1 and an air flow rate of 18,000 Nm3 h-1. The results showed that at temperatures of 45,50,55, and 60℃, the removal efficiencies of ammonia nitrogen (NH3-N) were 87.5%, 93.4%, 96.8%, and 98.7%, respectively. It was observed that temperature had the most significant impact on the removal efficiency of NH3-N under these conditions. As the air loading rate increases, the removal rate also increases, but the increase in removal efficiency is not significant because droplets from the absorption tower flow into the stripping tower. Even if the liquid loading rate was changed by ±30%, the removal rate did not change significantly. This does not mean that the removal rate was unaffected, but was believed to be due to the relatively high air load rate. Through demonstration research, it was confirmed that ammonia stripping is a reliable technology that can stably treat high-concentration ammonia wastewater generated in the high-tech electronics industry.

Adsorption Properties of Oxidized NO by Plasma Using Hybrid Anion-Exchange Fibers (복합음이온 교환섬유의 플라스마 산화 처리한 NO의 흡착특성)

  • Cho In-Hee;Kang Kyung-Seok;Hwang Taek-Sung
    • Polymer(Korea)
    • /
    • v.30 no.4
    • /
    • pp.291-297
    • /
    • 2006
  • In this study, adsorption properties of oxidized NO by plasma using aminated polyolefin-g-GMA hybrid anion exchange fibers were investigated. The maximum conversion of $NO_2$ by plasma was 49% at the conditions of 200 ppm NO, 10% $O_2$ and 30 L/min of flow rate. The adsorption content for N02 of hybrid anion exchange fibers increased with increasing the swelling ratio and the highest value was 1.5 g $H_2O/g$ IEF. The adsorption of $NO_2$ by hybrid anion exchange fibers were very fast until 10 min and reached its maximum value of 80% at 120 min. Ion exchange capacity of hybrid anion exchange fibers increased with increasing the swelling ratio and it showed the highest 0.6 mmol/g IEF values at L/D=5. The adsorption isotherm model for hybrid anion exchange fibers were closer to Freundlich than Langmuir adsorption isotherm model. It was shown that adsorption of the multi-molecular layer was dominant.

VOCs Oxidation Characteristics of Transition $Metals/\gamma-Al_2O_3$ Catalyst (전이금속/$\gamma-Al_2O_3$ 촉매의 VOCs 산화특성)

  • Kim, Bong-Soo;Park, Yeong-Seong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.4
    • /
    • pp.444-451
    • /
    • 2007
  • Catalytic oxidation characteristics of benzene as a VOC was investigated using a fixed bed reactor system over transition $metals/\gamma-Al_2O_3$ catalysts. As transition metals, eight metals including copper, nickel, manganese, iron etc. were adopted. The parametric tests were conducted at the reaction temperature range of $200\sim500^{\circ}C$, benzene concentration of $1,000\sim3,000$ ppm, and space velocity range of $5,000\sim60,000\;hr^{-l}$. The property analyses such as BET, SEM, XRD and the conversions of catalytic oxidation of VOC were examined. The experimental results showed that the conversion was increased with decreasing VOC concentration and space velocity. It was also found that $Cu/\gamma-Al_2O_3$ catalyst calcinated at $500^{\circ}C$ showed the highest activity for the oxidation of benzene and 15% metal loading was the optimum impregnation level.

Reflectance and Flexural Modulus of ABS/TiO2 Composite Sheets (ABS/TiO2 복합체 쉬트의 반사율과 굴곡 탄성률)

  • Kim, Jun Hong;Yoon, Kwan Han
    • Polymer(Korea)
    • /
    • v.38 no.1
    • /
    • pp.103-107
    • /
    • 2014
  • Poly(acrylonitrile-butadiene-styrene) (ABS) composite sheets containing titanium dioxide ($TiO_2$), barium sulfate ($BaSO_4$), calcium carbonate ($CaCO_3$) were prepared by using a co-rotating twin screw extruder, and the reflectance and flexural modulus of the composite sheets were measured. The fillers were well dispersed in ABS matrix. The reflectance of composite sheet was increased with increasing $TiO_2$ and $BaSO_4$ content. Sheet having $TiO_2$ 20 wt% composition, with 5~20 wt% $BaSO_4$ resulted in more than 95% of reflectance. The flexural modulus of composite sheet was increased from 1864 MPa for $ABS/TiO_2/BaSO_4$ 85/10/5 (w/w/w) to 3134 MPa for $ABS/TiO_2/BaSO_4$ 55/20/25 (w/w/w).

Battery Sensitivity Analysis on Initial Sizing of eVTOL Aircraft (전기 추진 수직이착륙기의 초기 사이징에 대한 배터리 민감도 분석)

  • Park, Minjun;Choi, Jou-Young Jason;Park, Se Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.12
    • /
    • pp.819-828
    • /
    • 2022
  • Sensitivity of aircraft sizing depending on battery performance was studied for a generic quad tilt rotor type electric vertical takeoff and landing vehicle. The mission requirements proposed by Uber Elevate and NASA were used for initial sizing, and the calculated gross weight is ranged between 5,000lb and 11,000lb for battery specific energy range of 200-400Wh/kg in pack level and continuous discharge rate range of 4-5C. For the assumed gross weight of 7,000lb, the required battery performance was calculated with two different criteria: available power and energy, and the effects of battery specific energy and discharge rate are analyzed. The maximum discharge rate is also recommended considering failure cases such as one battery pack inoperative and one prop rotor inoperative.

Electrochemical Characteristics of Polyoxometalate/Polypyrrole/Carbon Cloth Electrode Synthesized by Electrochemical Deposition Method (전기화학 증착법에 의해 합성된 폴리옥소메탈레이트/폴리피롤/탄소천 전극의 전기화학적 특성)

  • Yoon, Jo Hee;Choi, Bong Gill
    • Applied Chemistry for Engineering
    • /
    • v.27 no.4
    • /
    • pp.421-426
    • /
    • 2016
  • In this report, polyoxometalte (POM)-doped polypyrrole (Ppy) was deposited on surface of three-dimensional carbon cloth (CC) using an electrodeposition method and its pseudocapacitive behavior was investigated using cyclic voltammetry and galvanostatic charge-discharge. The POM-Ppy coating was thin and conformal which can be controlled by electrodeposition time. As-prepared POM-Ppy/CC was characterized using scanning electron microscope and energy-dispersive X-ray spectroscopy. The unique 3D nanocomposite structure of POM-Ppy/CC was capable of delivering excellent charge storage performances: a high areal capacitance ($561mF/cm^2$), a high rate capability (85%), and a good cycling performance (97% retention).

Dynamic Modeling and Control Strategies for Retention and Formation on a Paper Machine using a Microparticulate Retention Aid System

  • Cho, Byoung-Uk;Garnier Gil;Ven Theo G.M. van de;Perrier Michel
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.04a
    • /
    • pp.103-112
    • /
    • 2006
  • 제지 기계의 습부 공정을 안정화시키고, 또한 종이의 지필도에 악영향을 끼치지 않으면서 종이의 기계방향 물성의 변이를 줄이기 위해서, 보류도와 지필도 공정을 동시에 제어하기 위한 제어전략들이 개발되었다. 보류도와 지필도에 미치는 주 변수들에 관한 연구를 양이온성팜(CPAM)/벤토나이트 보류제와 파일럿 제지 기계를 사용하여 수행하였다. 마이크로파티클 보류제 첨가량이 보류도와 지필도에 미치는 영향을 설명하기 위해서 deposition efficiency 모델과 bridging strength 모델을 개발하였다. 제지 기계 보류 공정의 동특성 모델을 질량수지분석을 사용해서 개발하였다. 지료화학 변수의 효과를 모델에 포함하기 위해서, 보류도를 작업조건들에 의존하는 변수로 모델에 포함시켰다. 또한 지필도의 실험적 모델을 개발하고 보류공정을 위한 동특성 모델들과 연계해서 지필도의 동특성을 모사하였다. 여러 제어 전략들이 시뮬레이션상에서 실험되어졌다. 평량과 종이의 회분율 대신에 종이내의 펄프 질량과 충전제 질량을 제어하면 decouper를 사용하지 않고도 두 제어 루프간 상호작용을 줄일 수 있음을 보였다. 지필도의 제어를 위해서, 헤드박스 펄프 농도제어와 폴리머유량과 벤토나이트 유량의 비율제어를 제안하였다. 지종 변경시 백수농도의 설정값을 계산하는 문제를 해결하였다. 또한, 평량, 회분율, 백수농도 및 헤드박스 펄프 농도의 다변수제어가 논의되었다.

  • PDF