• Title/Summary/Keyword: 출력측정

Search Result 2,625, Processing Time 0.032 seconds

Stabilization and characterization of a 10 GHz harmonically mode-locked Er-doped fiber ring laser by suppression of relaxation oscillation (완화진동억압을 이용한 10 GHz 고조모드잠금된 고리형 어븀첨가 광섬유 레이저의 출력 안정화 및 특성 측정)

  • 장지웅;이유승;전영민;임동건
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.1
    • /
    • pp.58-64
    • /
    • 2002
  • Using Mach-Zehnder type intensity modulator, we stabilized a 10 GHz harmonically mode-locked dispersion-compensated fiber ring laser using a feedback controlling system, and we measured its stability. The laser was stabilized for more than 16 hours by controlling the cavity length to suppress the relaxation oscillation frequency component which had caused the laser output instability. The ms timing jitter and ms amplitude noise were measured to be 260-524 fsec and 4~11.5%, respectively, and BER test measurement showed a value of 10$^{-13}$ .

A Study on Introduction Plan for Power Limit of National Mobile Communication Handsets (국내 이동통신 단말기의 출력기준 도입방안에 관한 연구)

  • Kim, Jong-Heon;Noh, Sung-Gi;Lee, Young-Hwan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.6
    • /
    • pp.120-128
    • /
    • 2010
  • In this paper, equivalent isotropic radiated power (EIRP) of six mobile phones made by two national companies were measured in order to introduce power limit of mobile phones for national CDMA, PCS and WCDMA applications. The measurement has been conducted in a full anechoic chamber and used antenna substitution method. From the measured results, the measured power of the mobile phones are compared by power limit regulations of mobile phones for USA, Japan and Europe. Finally, we propose power limits of 2 W ERP for CDMA phones, 2 W EIRP for PCS phones, and 2 W EIRP for WCDMA phones, respectively.

Improvement of Measurement and Selectivity of Hydrogen Gas Using Multi-gas Sensors (다중 가스센서를 이용한 수소가스 측정 및 선택도 향상 연구)

  • Sun, Jong-Ho;Han, Sang-Bo;Yi, Sang-Hwa;Kim, Kwang-Hwa;Kang, Dong-Sik;Hwang, Don-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.114-119
    • /
    • 2006
  • In this paper, measurement of hydrogen gas using three kinds of gas sensors were studied for improving selectivity and quantification on hydrogen gas. Output characteristics for each sensors were analyzed to some concentrations of hydrogen gas. It was illustrated that the wide range of hydrogen gas concentrations upto 10,000[ppm] can be reliably measured from investigation of concentration ranges with high amplitudes and good resolutions. Also, the combinations of outputs from three kinds sensors were able to improve the selectivity of hydrogen gas.

Thermistor를 이용한 저궤도 위성용 온도 모니터링 시스템의 측정범위 개선

  • Lee, Sang-Rok;Im, Seong-Bin;Jeon, Hyeon-Jin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.188.2-188.2
    • /
    • 2012
  • 인공위성의 성능을 최대화 하고 긴 운용 수명을 확보하기 위해 부품들의 온도를 특정 범위로 유지 시키는 것은 매우 중요며 이를 위한 온도 모니터링 시스템은 필수적이다. 온도 모니터링 방법은 온도에 따라 저항이 변하는 Thermistor를 이용하는 방법과 출력 전류가 변하는 반도체 센서(AD590)를 이용하는 방법으로 나눌 수 있다. Thermistor의 경우 매우 정밀하게 온도를 모니터링 할 수 있지만 넓은 측정 범위에 대해서는 비선형성 가진다는 단점을 가진다. 이에 반해 반도체 센서의 경우 오차가 크지만 넓은 측정 범위에 대해서도 선형성을 가진다는 장점을 가진다. 본 논문에서는 특정 구간에 대해서 정밀한 온도 모니터링이 필요한 곳에 적용되는 Thermistor를 이용한 온도 모니터링 시스템의 측정 Mechanism에 대해서 고찰한다. 측정 Mechanism의 고찰은 온도에 따른 이산화 된 출력을 내주기 위해 사용되는 Thermistor, Current Source, A/D Converter 등의 하드웨어 적인 부분뿐만 아니라 출력된 값을 이용해 물리적인 온도로 변환시키는데 사용되는 Gain Offset, Calibration Curve 등의 소프트웨어 적인 부분도 포함한다. 또한 하드웨어와 소프트웨어적인 설계 변수를 조절함으로서 온도 모니터링 시스템의 측정범위를 개선하는 방안에 대해 고찰한다. 이렇게 본 논문에서 고찰한 Thermistor를 이용한 저궤도 위성용 온도 모니터링 시스템의 측정범위 개선 방안은 추후 인공위성에 적용되는 온도 모니터링 시스템의 설계에 Design Guide Line을 제시할 것이라고 판단한다.

  • PDF

Design of 4×4 Array Synthesis Horn Antenna and Radiated Power Measurement by Magnetron (4×4 배열 합성 혼 안테나 및 고출력 마그네트론에 의한 방사전력 측정)

  • Ko, Dong-Ok;Shin, Jae-Yoon;Woo, Jong-Myung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.5
    • /
    • pp.108-115
    • /
    • 2016
  • In this paper, the array synthesis horn antenna was designed and measured a radiation power after connecting magnetron. The proposed antenna was designed on the basis of the $4{\times}4$ array synthesis horn antenna characteristics. For suppressing a back-lobe, 2 step short-stub structures were attached to synthesis horn aperture upper and lower. The designed antenna has FBR(Front to Back Ratio) of 39.7 dB. HPBW(Half Power Beam Width) of the E-plane and the H-plane are $8.86^{\circ}$ and $7.35^{\circ}$ each in the measurement. For measuring a radiation power of array antenna that use a magnetron, the waveguide adaptor was designed and connected magnetron with horn antenna. Also, microstrip line coupler that replace a dielectric material with an air gap was designed for measuring a high power. As a result, average radiation output power of the $4{\times}4$ array synthesis horn antenna that connect a four magnetrons had a 0.063W.

The Usefulness Assessment of Verifying Daily Output by Using CHECKMATE$^{TM}$ (CHECKMATE$^{TM}$를 이용한 일일 출력 검증의 유용성 평가)

  • Cho, Han-Sang;Nam, Sang-Soo;Park, Hae-Jin;Kim, Mi-Hwa;Park, An-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • Purpose: In this study, we tried to check the usefulness of two Linear Accelerators, Clinac IX and 21EX (Varian, Palo Alto, CA), which are equipped in Ajou Medical Center. From 2008 to 2010, we evaluated the error range of Absolute Dose based on the daily output, which was measured by CHECKMATE$^{TM}$ (Sun Nuclear, Melbourne, FL). Materials and Methods: For Daily Q.A, photon beams of two linear accelerators, 21EX and IX (6 MV and 10 MV, respectively) were measured daily by using CHECKMATE$^{TM}$ just before the treatment began, while the absolute dose was measured biweekly by using water phantom. We analyzed the data of measured values from the daily Q.A and the absolute dose from 2008 to 2010 for 21EX, and from 2009 to 2010 for IX. We utilized Excel 2007 (Microsoft, USA) to evaluate Average, Standard deviation and Confidence level of the data. Furthermore, in order to check the measured values of CHECKMATE$^{TM}$ and the significance of absolute dose, each error value was compared and analyzed. Results: During the observation period, the output of two equipment's absolute dose increased in process of time and in both 6 MV and 10 MV, there was a similar increasing trend. In addition, the error rate of the measured value of CHECKMATE$^{TM}$ and the value of absolute dose were under 0.34, which means that there is a similarity relationship between the two measured values. After checking that the measured value of CHECKMATE$^{TM}$ increased, We measured the absolute dose to adjust that. When the error range was close to 2~3%, the number of changing the output was four for 21EX and three for IX. Conclusion: As a result of measuring and analyzing the daily output changes for two years by using CHECKMATE$^{TM}$, we could find that there is a significance between the output which we should obey during Q.A, and the measured value of absolute dose within the error tolerance of 2~3%. Thus, the use of CHECKMATE$^{TM}$ can be positively considered for more efficient and reliable daily output verification of linear accelerator. It can also be a good standard for other medical centers to understand the trends of linear accelerator and to refer to for the correction of each output.

  • PDF

간섭 통제를 위한 안테나 이득 측정 기술

  • Jo, In-Gwi;Yun, Jae-Hun;Kim, Chang-Ju
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.3
    • /
    • pp.64-71
    • /
    • 2008
  • 본 고에서는 의도성 기기에 대한 전자파 간섭을 규제하는 방법 중에서 "공중선전력+안텐 이득"을 통해 규제를 행하는 경우, 합리적인 안테나 이득 측정 방법에 대해 나타내고자 한다. 이는 ERP/EIRP를 규제 대상으로 하는 것, 이 외에도 공중선전력과 안테나 이득에 대해서도 규제하겠다는 의미인 것이다. 한편, 중 출력 혹은 대 출력의 무선 장비의 ERP/EIRP를 산출하는 경우에 매우 유용하고 합리적인 방안이 될수 있다. 본 고에서는 간섭 통제를 위한 안테나 이득 측정 기술을 나타내고자 한다.

광산란을 이용한 미소표면결함의 비접촉측정법에 관한 연구

  • 강영준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.113-120
    • /
    • 1991
  • 근년, 정밀가공기술의 진보에 따라 AI 합금이나 동등의 연질금속을 이용한 고출력 Laser용 Mirror, 전자계산용 자기Disc기반, Laser Printer용 PloygonMirror등의 Opto-electronics 부품이 경면(Mirror Surface)절삭가공에 의해서, 또 LSI용 Silicon Wafer의 가공은 연마가공에 의해서 nmRmax의 표면조도로 마무리 가공되고 있다. 본 연구에서는 고출력 Laser용 Mirror, 자기Disc기반, Silicon Wafer와 같은 경면(표면 조도 submicron이하)에 존재하는 미소표면결함을 정량적이며, 고속측정이 가능한 방법인 새로운 측정법을 제안하고, 이 시스템을 생산라인에서 가공과 동시에 검사하는 In-process측정이 가능한 특정 시스템의 개발을 최종목표로 하고 있다.

A time-frequency analysis of the EEG in negative and positive emotional states evokede by visual stimuli (시각 자극에 의한 긍/부정 감성상태에서 측정한 뇌파에 대한 시간-주파수 분석)

  • 류창수;김승환;박선희;이임갑;김지운;손진훈
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1997.11a
    • /
    • pp.98-101
    • /
    • 1997
  • 사람 사이의 가장 간단한 의사 표현인 긍정/부정을 뇌파를 통해 분별하려는 작업의 첫걸음으로 시각자극에 의해 일어난 긍정/부정 감성 상태에 대해 전두부와 후두부에서 뇌파를 측정하였다. 시간-주파수 분석을 행하고, 특정 주파수 세부 대역에서 상대출력의 시간에 따른 변화를 살펴보았다. 긍정적 감성상태에서는 느린 a 파의 증가가, 부정적 감성상태에서는 빠른 a파일의 증가가 관찰된다. 이러한 상대출력의 시간에 따른 증감을 통해 긍정/부정 감성상태의 분별 규칙을 설정하여 측정된 뇌파에 적용을 보았다.

  • PDF

Development of monitor color measurement device for color management system (CMS 구현을 위한 모니터 색 측정 장비 개발)

  • 박철호;김홍석;박승옥
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.116-117
    • /
    • 2003
  • 현재 입·출력 장치 간의 색 불일치 문제를 해결하기 위한 방안으로 각 장치의 색 특성 정보를 담고있는 ICC 프로파일을 기반으로 한 CMS(색 관리 시스템)가 개발이 되고 있다. 정확한 색 관리가 이루어지기 위해서는 무엇보다 출력물의 평가 기준이 되는 모니터의 올바른 보정이 이루어져야 하는데, 이에 따른 방안으로 색 측정장비를 통한 소프트웨어적 보정 방법이 사용되고 있다. 색 측정장비는 분광 방식의 Spectrometer 타입과 필터식의 Colorimeter 타입으로 구분이 된다. (중략)

  • PDF