Improvement of Measurement and Selectivity of Hydrogen Gas Using Multi-gas Sensors  

Sun, Jong-Ho (한국전기연구원 전력설비진단연구그룹)
Han, Sang-Bo (한국전기연구원 산업전기연구단 전력설비진단 연구그룹)
Yi, Sang-Hwa (한국전기연구원 산업전기연구단 전력설비진단 연구그룹)
Kim, Kwang-Hwa (한국전기연구원 산업전기연구단 전력설비진단 연구그룹)
Kang, Dong-Sik (한국전기연구원 산업전기연구단 전력설비진단 연구그룹)
Hwang, Don-Ha (한국전기연구원 산업전기연구단 전력설비진단 연구그룹)
Publication Information
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers / v.20, no.10, 2006 , pp. 114-119 More about this Journal
Abstract
In this paper, measurement of hydrogen gas using three kinds of gas sensors were studied for improving selectivity and quantification on hydrogen gas. Output characteristics for each sensors were analyzed to some concentrations of hydrogen gas. It was illustrated that the wide range of hydrogen gas concentrations upto 10,000[ppm] can be reliably measured from investigation of concentration ranges with high amplitudes and good resolutions. Also, the combinations of outputs from three kinds sensors were able to improve the selectivity of hydrogen gas.
Keywords
Power transformer; Hydrogen gas in oil; Gas sensor;
Citations & Related Records
연도 인용수 순위
  • Reference
1 J.J.Kelly. 'Transformer Fault Diagnosis by Dissolved-Gas Analysis' IEEE Transactions on Industry Application. Vol. 16. No. 6. pp. 777-782, November 1980   DOI
2 ANSI/IEEE C57.104-1978, 'Guide for the detection and determination of generated gases in oil-immersed transformer and their relation to the serviceability of the equipment'
3 A. Varl, 'On-line diagnostics of oil-filled transformers', Proc. ICDL 2002, pp. 253-257, July 2002
4 J. L. Rodriguez et al., 'Robust, wide range hydrogen sensor', IEDM 92, pp.521-524
5 S. Birlasekaran et al., 'Use of FFT and techniques in monitoring of transformer fault gases', proc. 1998 ISEIM, pp.75-78
6 M. Shirai et al.,'Generation of hydrogen from insulating oil in transformer', JIEEJ A, Vol. 96, No. 6, 1976
7 Y. Inoue et al., 'Development of oil-dissolved hydrogen gas detector for diagnosis of transformer', IEEE Trans. on PWRD, Vil. 5, No. 1, 1990
8 GE Syprotec, Hydran H201i System and Hydran H201R Model I, Transformer Incipient Fault Monitor, Instruction Manual Version 2.11. March 97
9 R. Qin, 'An oil/gas separation membrane and its use in gas sensor for on-line incipient fault monitoring of transformer', ACED 2004 pp.385-387
10 IEC Publication 567, Guide for the sampling of gases and of oil from oil filled electrical equipment and for the analysis of free and dissolved gases, Second Edition, 1992
11 S. B. Belhouari, et al., 'Gas identification algorithm for microelectronic gas sensor', IMTC 2004, pp584-587, May 2004