Hybrid Off-pump Coronary Artery Bypass Combined with Percutaneous Coronary Intervention: Indications and Early Results (심폐바이패스 없이 시행하는 관상동맥우회술과 경피적 관상동맥중재술의 병합요법 : 적응증 및 조기성적)

  • Hwang Ho Young;Kim Jin Hyun;Cho Kwang Ree;Kim Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.38 no.11 s.256
    • /
    • pp.733-738
    • /
    • 2005
  • Background: The possibility of incomplete revascularization and development of flow competition after revascularization of the borderline lesion made the hybrid strategy as an option for complete revascularization. Material and Method: From January f998 to July 2004, 25 $(3.2\%)$ patients underwent hybrid revascularization among 782 total OPCAB procedures. Clinical results and angiographic patencies were evalulated. Percutaneous coronary intervention (PCI) was peformed before CABG in 8 patients and after CABG in 47 patients. Result: The causes of PCIs before CABG were to achieve complete revascularization with minimally invasive surgery (n=7) and emergent PCI for culprit lesion (n=1). The indications of PCIs after CABG were high possibility of flow competition in the borderline lesion of right coronary artery territory (n=8), diffuse atheromatous lesion preventing anastomosis of graft (n=5), severe calcified ascending aorta with no more arterial grafi available (n=3), and intramyocardial coronary lesion (n=1). Mean number of distal anastomoses was $2.3\pm1.0$. Mean number of lesions treated by PCI was $1.2\pm0.4$. There was no operative or procedure-related mortality. PCI-related complication was periprocedural myocardial infarction in one patient, and complications related to CABG were transient atrial fibrillation (n=5), perioperative myocardial infarction (n=1), and transient renal dysfunction (n=1). Early postoperative coronary angiography $(1.8{pm}1.6days)$ revealed $100\%$ patency rate of grafts (57/57). The stenosis occurred in one patient performed PCI before CABG, which was successfully treated with re-ballooning. During midterm follow-up (mean; $25{\pm}26$ months), 1 patient died of congestive heart failure. All survivors (n=24) accomplished follow-up coronary angiographics, which showed .all grafts (56/57) were patent except one string sign. In-stent restenosis was developed in 2 patients who received bare metal stents. Conclusion: In selected patients, complete revascularization was achieved with low risk by taking the hybrid strategy.

Multi-vessel Small Thoracotomy (MVST) CABG with Robot-assisted Bilateral ITA Harvesting - A case report - (수술 로봇을 이용한 양측 내흉동맥 채취 후 시행한 최소 침습적 다혈관 관상동맥 우회술 - 1예 보고 -)

  • Chung, Jin-Woo;Lee, Jae-Won;Je, Hyoung-Gon
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.264-267
    • /
    • 2008
  • The da Vinci telemanipulator system (Intuitive Surgical, Sunnyvale, CA USA) is the most advanced robotic surgical system and has been increasingly used for cardiac surgical procedures. We report out first clinical experience of use of the da Vinci telemanipulator system for endoscopic harvesting of the bilateral thoracic artery andmulti-vessel small thoracotomy off pump CABG for 3-vessel disease. The da Vinci telemanipulator system has been previously utilized primarily for mitral valve surgery.

Redo CABG Using Various Arterial Grafts (다양한 동맥도관을 이용한 재관상동맥 우회술)

  • Min, Ho-Ki;Lee, Young-Tak;Lee, Min-A;Kim, Wook-Sung;Park, Pyo-Won;Sung, Ki-Ick;Jun, Tae-Gook;Yang, Ji-Hyuk
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.456-463
    • /
    • 2009
  • Background: Although the reports on re-operative coronary revascularization (redo-CABG) have increased, there are only limited reports on redo-CABG using arterial grafts. The aim of this study was to analyze the safety and feasibility of using various arterial grafts for redo-CABG. Material and Method: A consecutive series of patients who underwent 33 redo-CABGs from March 2001 to July 2008 were retrospectively reviewed. We performed conventional CABG in 17 patients, on-pump beating CABG in 7, off-pump CABG in 7 and minimally invasive direct coronary artery bypass in 2. The grafted that were used included 34 internal thoracic arteries (ITA), 14 radial arteries, 14 right gastroepiploic arteries and others. Arterial composite grafts were constructed in 26 patients. Of these, a previously patent in-situ left ITA was re-used as the in-flow of a composite graft in 10 patients. Result: No hospital deaths or major wound problems occurred. The post-operative complications included 2 myocardial infarctions (6%), 1 intra-aortic balloon pump insertion (3%), 5 cases of atrial fibrillation (15.1 %) and 3 neurologic complications (9.1%). The meanfollow-up duration was 31.1$\pm$22.7 months and the 3 year survival rate was 86.4%. There were 4 late deaths (2 cardiac deaths) and no recurrent angina during the follow-up period. Conclusion: Redo-CABG with using various arterial grafts is currently a safe, feasible procedure, but further investigation and long term follow-up are needed.

Clinical Results of 100 Cases of Coronary Artery Bypass Grafting without Cardiopulmonary Bypass (심폐바이패스 없이 시행한 관상동맥 우회술 100예의 임상적 고찰)

  • 방정희;우종수
    • Journal of Chest Surgery
    • /
    • v.37 no.4
    • /
    • pp.322-327
    • /
    • 2004
  • Coronary artery bypass grafting on the beating heart is no longer a new methods for any cardiac surgeon. We evaluated the application of the off-pump coronary artery bypass procedure relative to safety and efficiency as measured by postoperative complication and operative mortality. Material and Method: We used our retrospective database to compare the patients having off-pump coronary surgery (n=100) with those having on-pump coronary surgery (n=100) between June, 1999 and August, 2002. Patients whom underwent associated valvular or aortic aneurysmal operation were excluded. Result: Neither groups showed any differences in the patient's risk factors and extent of coronary disease. Off-pump CABG group did not have significantly less mean operation time (295$\pm$73 min vs 323$\pm$83 min, p=ns) and mean hospital day (15.34$\pm$6.02 day vs 13.80$\pm$4.95 day, p=ns). However, off-pump CABG group had significantly shorter mean ventilation time (17.3$\pm$11.27 hour vs 24.98$\pm$16.1 hour, p<0.05). No patients were converted to on-pump CABG in off-pump CABG. Intraoperative hemodynamic instability in off-pump CABG were 6 cases, of whom 2 cases were in lateral wall approach and 4 cases in right coronary anastomosis. Postoperative mortality was 1 case in off-pump CABG and 2 cases in on-pump CABG. Intra-aortic ballon pump (IABP) was applied in 1 case with off-pump CABG and in 2 cases with on-pump CABG. No patients presented postoperative cerebral infarction & stroke in off-pump CABG but 2 patients in on-pump CABG. Postoperative arrhythmia presented in 4 cases with off-pump CABG and in 6 cases with on-pump CABG. Acute renal failure (ARF) was complicated in 3 cases with off-pump CABG and in 2 cases with on-pump CABG. Conclusion: This study documented the immediate safety and efficiency of the off-pump CABG procedure.

Routine Off-pump Total Arterial Coronary Revascularization (심폐바이때스 없이 시행된 동맥 도관만를 이용한 관상동맥 완전 재관혈화)

  • Lee, Jae-Won;Park, Nam-Hee;Kang, Seong-Sik;Choo, Suk-Jung;Park, Seung-Jung;Park, Seung-Wook;Hong, Myeong-Ki;Song, Hyun;Song, Meong-Gun
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.309-315
    • /
    • 2003
  • Background: To avoid the adverse effects of cardiopulmonary bypass and to overcome late vein graft failure we routinely peformed off-pump total arterial coronary revascularization. Material and Method: From July 2000 to August 2001, 104 consecutive patients underwent first elective off-pump total arterial coronary revascularization. Both internal mammary, radial and gastroepiploic arteries were used. Sequential and composite grafts were used to achieve complete revascularization. Perioperative adverse events and postoperative angiograms were analyzed. Result: A total of 252 arterial conduits were used with an average of 2.47 grafts per patient. A total of 326 distal anastomosis were performed with a mean of 3.13 distal anastomosis per patient. Cross over to on-pump occurred in seven patients (6.7%). Of these 4 were due to unstable hemodynamics during lateral or posterior wall stabilization as a result of cardiomegaly and 3 were due to uncontrolled bleeding during dissection of diffusely dimunitive deeply placed intramyocardial coronary arteries. There were no opeartive deaths. Two cases of perioperative myocardial infarction and transient neurologic complications occurred, respectively. Of the 312 distal anastomoses, 308 (98.7%) were compatible with Fitz-Gibboll A or B patency grading. Conclusion: Off-pump total arterial coronary revascularization was technically feasible in most elective cases with satisfactory early results. However, on-pump coronary bypass surgery should be considered in difficult circumstances, such as cardiomegaly or unfavorable anatomy of the target coronary artery.

Combined Percutaneous Transluminal Coronary Angioplasty and Minimally Invasive Coronary Arterial Bypass Grafting(Hybrid CABG) (경피적 경혈관 관상동맥 중재술과 최소침습성 관상동맥 우회술의 병용요법)

  • 장지민;유원희;김기봉
    • Journal of Chest Surgery
    • /
    • v.32 no.12
    • /
    • pp.1127-1130
    • /
    • 1999
  • Percutaneous coronary intervention including intracoronary stenting is currently an accepted treatment modality in the treatment of coronary artery disease and is widely performed to treat the patient with multivessel disease with decreased morbidities and less cost compared with conventional coronary rtery bypass grafting(CABG), Repeated interventions due to restenosis even after successful angioplasty are the major disadvantage of the angioplsty especially when the lesion is located inthe left anterior descending artery(LAD) Recently CABG through left anterior small thoracotomy using the left internal thoracic artery to revascularize the LAD territory without cardiopulmonary bypass so called Minimally Invasive Direct Coronary Artery Bypass(MIDCAB) was intrduced and performed with comparable early outcomes. In this regard the integrated approach with percutaneous coronary intervention and minimally invasive direct coronary artery bypass surgery so called 'Hybrid CABG' was suggested to be an effective treatment in suitable patients with multivessel coronary artery disease. We report three cases of Hybrid CABG.

  • PDF

Early and Mid-Term Results of MIDCAB (최소 침습적 관상 동맥 우회술의 중단기 성적)

  • 손호성;방영호;황진욱;민병주;조양현;박성민;이성호;김광택;선경
    • Journal of Chest Surgery
    • /
    • v.37 no.10
    • /
    • pp.827-832
    • /
    • 2004
  • Background: The significance of MIDCAB is emerging topics recently as OPCAB is going to be universalized, and long-term outcome of bypass graft surgery was proved to be more excellent than balloon dilation or stent insertion. We report our MIDCAB results in 73 patients in the last three years. Material and Method: Retrospective analysis of medical records was done from November 1, 2000 through November 31, 2003. There were 47 males and 26 females ranging in age from 31 years to 79 years (average $61.3\pm9.8$ years). Observation periods after operative procedures were 10 to 1238 days (average $763\pm319.8$ days). Left longitudinal parasternal incision as a standard procedure was done to approach the heart after dissection of the left internal thoracic artery by partial or total resection of 3rd to 5th ribs. Result: Of those patients, 46 patients were transferred to ICU after extubation at operation room and 58 patients were extubated within 3 hours after operation. Average ICU staying periods was $26.8\pm11.5$ hours. Follow-up angiography during admission was done in 36 patients and showed 100% patency. Only one patient died on the 10$^{th}$ post operative day because of sudden CVA. Complications included wound problems in 4 patients, and constructing pericardial window using thoracoscopy due to continuous pericardial effusion in 1. Permanent pacemaker was inserted in one patient owing to sick sinus syndrome. In one patient with recurrence of angina 8 months after operation, stenosis at anastomic site was found and improved with balloon dilatation. Conclusion: We were satisfied with our results of MIDCAB in single and multi-vessel coronary artery disease. These results have made the cardiologists tried to operate positively and we expect widening operative indications including hybrid revascularization.

Thoracoscopic Aortic Valve Replacement assisted with AESOP (Automated Endoscope System for Optimal Positioning) 3000 (AESOP 3000을 이용한 흉강경적 대동맥 판막 치환술)

  • Shin Hong Ju;Kim Hee Jung;Choo Suk Jung;Song Hyun;Chung Cheol Hyun;Song Meong Gun;Lee Jae Won
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.507-509
    • /
    • 2005
  • Open heart surgery via right thoracotomy can be accomplished in atrial septal defects, and mitral valve diseases. Recently, thoracoscopic atrial septal defect closure, mitral valve repair, Maze operation, and minimal invasive direct coronary artery bypass (MIDCAB) are accomplished with AESOP 3000. However, there is no report of thoracoscopic aortic valve replacement in Korea. We report a successful thoracospic aortic valve replacement assisted with AESOP 3000 in a 31-year-old female patient.

The First 20 Cases of Cardiac Surgery Using the da $Vinci^{TM}$ Surgical System: A Single Center Experience (다빈치 수술로봇을 이용한 심장수술 20예 보고 - 단일 기관 보고 -)

  • Je, Hyoung-Gon;Lee, Yong-Jik;Jung, Sung-Ho;Jung, Jae-Seung;Kang, Pil-Je;Choo, Suk-Jung;Song, Hyun;Chung, Cheol-Hyun;Lee, Jae-Won
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.423-429
    • /
    • 2008
  • Background: The interest in robotic cardiac surgery has recently grown but there has not been much clinical research reported on this. The aim of this study is to examine our initial experience, since August 2007, with robotic cardiac surgery using the da $Vince^{TM}$ surgical system and to evaluate the feasibility and safety of it. Material and Method: Between August and December 2007, a total of 20 patients underwent robotic cardiac surgery using the da Vinci surgical system. For mitral valve repair (n=11), tricuspid valve repair (n=1), and ASD repair (n=1), cannulation, antegrade cardioplegia and transthoracic aortic cross-clamping were conducted for the right femoral vessels and the right internal jugular vein. For minimally invasive direct CABG (MIDCAB) (n=7), the internal thoracic artery (ITA) was harvested with the da Vinci surgical system. Result: The mean age of the patients was 50.1 (range: $26{\sim}78$) years. Three concomitant Maze procedures and one tricuspid annuloplasty were combined with mitral valve repair. The mean cardiopulmonary bypass time was $208.0{\pm}61.3$ minutes and the aortic cross clamp time was $158.8{\pm}40.6$ minutes. No patients showed more than mild mitral regurgitation after repair and the median hospital stay was 4 days. The robotic-harvested ITA was used for either left ITA (n=6) or bilateral ITA (n=1). The mean harvest time was $43.2{\pm}12.0$ minutes. The harvested ITA showed good flow and it was anastomosed under direct vision after left anterolateral thoracotomy. The patency of all the grafts was 100% (18/18) in MIDCAB. Conclusion: Robotic cardiac surgery using the da Vinci surgical system was variously adapted to areas such as mitral and tricuspid valve repair, ASD repair and ITA harvest for MIDCAB. The early results of the robotic cardiac surgery showed its safety and feasibility. With this primary report, we anticipate that clinical applications and further studies on robotic cardiac surgery using the da Vinci surgical system will be actively conducted in Korea.