Browse > Article

Clinical Results of 100 Cases of Coronary Artery Bypass Grafting without Cardiopulmonary Bypass  

방정희 (동아대학교 의과대학 흉부외과학교실)
우종수 (동아대학교 의과대학 흉부외과학교실)
Publication Information
Journal of Chest Surgery / v.37, no.4, 2004 , pp. 322-327 More about this Journal
Abstract
Coronary artery bypass grafting on the beating heart is no longer a new methods for any cardiac surgeon. We evaluated the application of the off-pump coronary artery bypass procedure relative to safety and efficiency as measured by postoperative complication and operative mortality. Material and Method: We used our retrospective database to compare the patients having off-pump coronary surgery (n=100) with those having on-pump coronary surgery (n=100) between June, 1999 and August, 2002. Patients whom underwent associated valvular or aortic aneurysmal operation were excluded. Result: Neither groups showed any differences in the patient's risk factors and extent of coronary disease. Off-pump CABG group did not have significantly less mean operation time (295$\pm$73 min vs 323$\pm$83 min, p=ns) and mean hospital day (15.34$\pm$6.02 day vs 13.80$\pm$4.95 day, p=ns). However, off-pump CABG group had significantly shorter mean ventilation time (17.3$\pm$11.27 hour vs 24.98$\pm$16.1 hour, p<0.05). No patients were converted to on-pump CABG in off-pump CABG. Intraoperative hemodynamic instability in off-pump CABG were 6 cases, of whom 2 cases were in lateral wall approach and 4 cases in right coronary anastomosis. Postoperative mortality was 1 case in off-pump CABG and 2 cases in on-pump CABG. Intra-aortic ballon pump (IABP) was applied in 1 case with off-pump CABG and in 2 cases with on-pump CABG. No patients presented postoperative cerebral infarction & stroke in off-pump CABG but 2 patients in on-pump CABG. Postoperative arrhythmia presented in 4 cases with off-pump CABG and in 6 cases with on-pump CABG. Acute renal failure (ARF) was complicated in 3 cases with off-pump CABG and in 2 cases with on-pump CABG. Conclusion: This study documented the immediate safety and efficiency of the off-pump CABG procedure.
Keywords
Coronary artery bypass; Minimally invasive surgery; Off-pump;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Intracoronary shunts reduce transient intraoperative mycardial dysfunction during off-pump coronary operations /
[ Yeatman,M.;Caputo,M.;Narayan,P.(et al.) ] / Ann Thorac Surg   DOI   ScienceOn
2 Coronary perfusion methods during off-pump coronary artery bypass: results of a randomized clinical trial /
[ Vassiliades,T.A.;Neilsen,J.L.;Lonquist,J.L. ] / Ann Thorac Surg   DOI   ScienceOn
3 The coronary artery bypass conduit: Ⅱ. Assessment of the quality of the distal anstomosis /
[ Wolfe,J.A. ] / Ann Thorac Surg   DOI   ScienceOn
4 Maintaining hemodynamic stability and mycardial performance during off-pump coronary bypass surgery /
[ Hart,J.C. ] / Ann Thorac Surg   DOI   ScienceOn
5 Safety and efficacy of Off-pump coronary artery bypass grafting /
[ Arom,K.V.;Flavin,T.F.;Emery,R.W.;Kshettry,V.R.;Janey,P.A.;Petersen,R.J. ] / Ann Thorac Surg   DOI   ScienceOn
6 Off-pump coronary artery bypass grafting /
[ Kim,K.B.;Lim,H.G.;Huh,J.H.;Ahn,H.;Ham,B.M. ] / Korean J Thorac Cardiovasc Surg
7 Financial of off-pump coronary artery bypass /
[ Lim,C.;Chang,W.I.;Kim,K.B.;Kim,Y. ] / Korean J Thorac Cardiovasc Surg   과학기술학회마을
8 Intraoperative coronary artery imaging with infrared camera in off-pump CABG /
[ Suma,H.;Isomura,T.;Horii,T.;Sato,T. ] / Ann Thorac Surg   DOI   ScienceOn
9 Off-pump coronary surgery: Effect on early mortality and stroke /
[ Cheng,W.;Denton,T.A.;Fontana,G.P.(et al.) ] / J Thorac Cardiovasc Surg   DOI   ScienceOn
10 The comparison of clinical study of off pump and on pump CABG /
[ Yoo,K.J.;Lim,S.H.;Song,S.W.;Kim,C.Y.;Hong,Y.S.;Chang,B.C. ] / Korean J Thorac Cardiovasc Surg   과학기술학회마을
11 Hemodynamic changes with right lateral decubitus body positioning in the tilted porcint heart /
[ Grundeman,P.F.;Borst,C.;Verlaan,C.W.J.;Damen,S.;Mertens,S. ] / Ann Thorac Surg   DOI   ScienceOn
12 Aortocoronary bypass graft: a case report /
[ Lee,D.Y.;Cho,K.S.;Cho,B.K.;Hong,S.N.;Cha,H.D.;Kim,S.S. ] / Korean J Thorac Cardiovasc Surg   과학기술학회마을
13 Improved outcomes in coronary artery bypass with beating heart technique /
[ Mack,M.;Bachand,D.;Acuff,T.(et al.) ] / J Thorac Cardiovas Surg   DOI   ScienceOn
14 Analysis of hemodynamic changes during beating heart surgical procedure /
[ Mathison,M.;Edgerton,J.R.;Horswell,J.L.;Akin,J.J.;Mack,M.J. ] / Ann Thorac Surg   DOI   ScienceOn
15 Role of graft flow measurement technique in anastomotic quality assessment in minimally invasive CABG /
[ Jaber,S.F.;Koenig,S.C.;bhaskerRao,B.(et al.) ] / Ann Thorac Surg   DOI   ScienceOn
16 Graft patency verification in coronary artery bypass grafting: principles and clinical applications of transit time flow measurement /
[ D'Ancona,G.;Karamanoukian,H.L.;Ricci,M.;Bergsland,J.;Salemo,T.A. ] / Angiology   DOI   ScienceOn
17 Off-pump versus on-pump coronary bypass in high-risk subgroups /
[ Yokoyama,T.;baumgartner,F.J.;Gheissari,A.;Capouya,E.R.;Panagiotides,G.P.;Declusin,R.J. ] / Ann Thorac Surg   DOI   ScienceOn
18 Epicardial ultrasound in off-pump coronary artery bypass grafting: potential and in intraoperative coronary diagnostics /
[ Klein,P.;Meijer,R.;Eikelaar,J.H.R.;Grundeman,P.F.;Borst,C. ] / Ann Thorac Surg   DOI   ScienceOn