• Title/Summary/Keyword: 총먼지

Search Result 136, Processing Time 0.029 seconds

Selection of New Particulate Matter Monitoring Stations using Kernel Analysis - Elementary Schools, Seoul, Korea (커널분석을 활용한 미세먼지 신규 측정소 선정 - 서울시 초등학교를 대상으로 -)

  • Jeong, Jong-Chul
    • Journal of Cadastre & Land InformatiX
    • /
    • v.49 no.2
    • /
    • pp.83-92
    • /
    • 2019
  • The particulate matters show high values in winter and spring season, it has a bad influence on the outdoor people. That's why government needs to come up with countermeasures for social weak people like elementary school students. In this paper, new particulate matter stations select ed about elementary schools using spatial analysis. Seoul city areas were divided with 608 hexagon grids(500m), and then implement spatial analysis such as kernel analysis. Finally, new particulate matter stations select through the results of kernel density analysis and point displacement. The results show that, 10 hexagon grids about new particulate matter stations were selected and listed 15 elementary schools including 10 hexagon grids. The 15 elementary schools were including Gangbuk gu, Eunpyeong gu, Guro gu, Dong gu, Geumcheon gu, Dongdaemun gu, Gangdong gu, Songpa gu, Gwangjin gu and Gangnam gu. The results suggests a new management plan direction according to the spatial analysis, result in the process of selecting the measures for the '2018 School Fine Dust Comprehensive Management Measures' announced by the Ministry of Education. Also, this study can be expanded by adding specific buildings as well as the school.

An Exploratory Study on the Effect of LCZ Type on Particulate Matter (LCZ 유형이 미세먼지에 미치는 영향에 관한 탐색적 연구)

  • Yeonju Kim;Hansol Mun;Juchul Jung
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.5
    • /
    • pp.338-352
    • /
    • 2023
  • As of 2019, Korea's fine dust is the most severe among 38 OECD countries, and in the same year, 「the Framework on Disaster and Safety Management」 was revised to define fine dust as a social disaster. Currently, the government is working to achieve its emission reduction goals by preparing a comprehensive fine dust management plan (2022-2023) consisting of a total of five areas, 42 tasks, and 177 detailed tasks. However, it is necessary to come up with measures in consideration of the various spatial characteristics of the city, not just as a source of emission. Therefore, in this study, the shape of the city was classified using the LCZ (Local Climate Zone) classification system into 17 types by building type and land cover type in Busan, and the average annual PM10 and PM2.5 concentration were mapped using the IDW technique. In addition, Fragstats and Moving Window were used to quantify the LCZ classification system. Finally, correlation analysis and regression analysis were conducted to analyze the relationship between the LCZ classification system and PM10 and PM2.5. As a result, it was confirmed that the type of low height of the building and the type of green space with trees had a positive effect on the concentration of PM10 and PM2.5. Therefore, this study is expected to be used as basic data to establish fine dust reduction policies based on efficient spatial planning.

Characteristics of indoor air quality in the overground and underground railway stations (지상과 지하역사의 실내공기질 특성과 외기영향 평가)

  • Namgung, Hyeong-Kyu;Song, Ji-Han;Kim, Soo-Yeon;Kim, Hee-Man;Kwon, Soon-Bark
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.17-25
    • /
    • 2016
  • In this study, the air quality of underground and overground railway stations was evaluated focusing on the degree of influence of the outside air quality. The measured components were particulate matter ($PM_{10}$), carbon dioxide ($CO_2$), carbon monoxide (CO), nitrogen dioxide ($NO_2$), formaldehyde (HCHO), ozone ($O_3$), total airborne bacteria (TAB), total volatile organic carbon (TVOC), and Radon (Rn), which are included in the maintenance standards and recommended standards of the Indoor Air Quality Management Act. Also, the indoor/outdoor concentration ratios of $PM_{10}$, $NO_2$, and $O_3$ were calculated to estimate the influence of the outdoor air quality. The concentrations of $PM_{10}$ HCHO, TVOC, $NO_2$, and Rn in the underground stations were found to be higher than those in the overground stations. These results indicate that the (present) generation of contaminants are caused by the indoor source of the underground station. The ozone concentration of the overground stations was higher than that of the underground stations, which indicates that the outdoor ozone concentration influenced that of the overground stations directly. Thus, methods of improving the IAQ should take into consideration the types of contamination.

Characterization of Heavy Metals Including Mercury and Fine Particulate Emitted from a Circulating Fluidized Bed Power Plant Firing Anthracite Coals (무연탄 순환유동층 발전소로부터 배출되는 수은을 포함한 중금속 및 미세분진의 배출 특성)

  • Kim, Jeong-Hun;Yoo, Jong-Ik;Seo, Yong-Chil
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.268-274
    • /
    • 2010
  • Emission of heavy metals as hazardous air pollutants has been focused with tightening regulatory limits due to their hazardousness. Measurements and characteristic investigations of heavy metals emitted from a commercial power plant burning anthracite coal have been carried out. The plant consists of a circulating fluidized bed combustor, a cyclone, a boiler and an electrostatic precipitator(ESP) in series. Dust and gaseous samples were collected to measure main heavy metals including gaseous mercury before ESP and at stack. Dust emissions as total particulate matter (TPM), PM-10 and PM-2.5 at inlet of ESP were very high with 23,274, 9,555 and $7,790mg/Sm^3$, respectively, as expected, which is much higher than those from pulverized coal power plants. However TPM at stack was less than $0.16mg/Sm^3$, due to high dust removal efficiency by ESP. Similarly heavy metals emission showed high collection efficiency across ESP. From particle size distribution and metal enrichment in sizes, several metal concentrations could be correlated with particle size showing more enrichment in smaller particles. Mercury unlike other solid metals behaved differently by emitting as gaseous state due to high volatility. Removal of mercury was quite less than other metals due to it's volatility, which was 68% only. Across ESP, speciation change of mercury from elemental to oxidized was clearly shown so that elemental mercury was half of total mercury at stack unlike other coal power plants which equipped wet a scrubber.

Trace Elements and Source Assessment of Street Dust in Daegu, Korea (대구지역 도로먼지에 함유된 미량원소성분과 오염원 평가)

  • Song, Hee-Bong;Lee, Eun-Young;Do, Hwa-Seok;Jung, Cheol-Su;Shin, Dong-Chan;Lee, Myoung-Sook;Paek, Yoon-Kyoung;Jeon, Seong-Suk;Shin, Won-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.7
    • /
    • pp.793-800
    • /
    • 2007
  • A total of 48 samples of street dust were collected in Daegu area during April and May 2006, were sieved below 100 ${\mu}m$, and analysed by ICP for the analysis of 14 elements after an acid extraction. Results obtained from the source assessment of trace elements using enrichment factor showed that Ca, Fe, K, Mg, Mn, Na and V were influenced by natural sources such as soil and dust, while Cd, Cr, Cu, Ni, Pb and Zn were influenced by urban anthropogenic sources such as fuel combustion and waste incineration. The measured values were remarkably higher in components from natural sources than in components from urban anthropogenic sources. The concentrations of trace elements in Daegu area were generally higher than in other foreign cities. Samples originated from industrial and commercial areas had higher concentrations of trace elements and pollution indices of heavy metals than those from residential and green areas. The correlation analysis among trace elements indicated that the correlations among components from urban anthropogenic sources were much significant, while those among components from natural sources were less correlated. In addition there were significant correlations between traffic density and components from urban anthropogenic sources.

FMEA of Electrostatic Precipitator for Preventive Maintenance (전기집진기 예지보전 단계에서의 고장모드영향분석)

  • Han, Seung-Hun;Lee, Jeong-Uk;Lee, Sun-Youp;Hwang, Jong-Deok;Kang, Dae-Kon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.6
    • /
    • pp.706-714
    • /
    • 2020
  • Currently, 90 % of the world's population breathes air with a fine dust content exceeding the World Health Organization's annual average exposure limit (10 ㎍/㎥). Global efforts have been devoted toward reducing secondary pollutants and ultra-fine dust through regulations on nitrogen oxides released over land and sea. Domestic efforts have also aimed at creating clean marine environments by reducing sulfur emissions, which are the primary cause of dust accumulation in ships, through developing and distributing environment-friendly ships. Among the technologies for reducing harmful emissions from diesel engines, electrostatic precipitator offer several advantages such as a low pressure loss, high dust collection efficiency, and NOx removal and maintenance. This study aims to increase the durability of a ship by improving equipment quality through failure mode effects analysis for the preventive maintenance of an electrostatic precipitator that was developed for reducing fine dust particles emitted from the 2,427 kW marine diesel engines in ships with a gross tonnage of 999 tons. With regard to risk priority, failure mode 241 (poor dust capture efficiency) was the highest, with an RPN of 180. It was necessary to determine the high-risk failure mode in the collecting electrode and manage it intensively. This was caused by clearance defects, owing to vibrations and consequent pin loosening. Given that pin loosening is mainly caused by vibrations generated in the hull or equipment, it is necessary to manage the position of pin loosening.

Ground Beetle (Coleoptera: Carabidae) Assemblage Structure in Taeanhaean National Park : A Comparison between Coastal Dune and Windbreak Forest (태안해안국립공원 내 지표성 딱정벌레류(딱정벌레목 : 딱정벌레과) 군집 구조 : 사구와 방풍림 간의 비교)

  • Jung, Jong-Kook;Hong, EuiJeong;Kim, Tae Geun;Jeong, Jong-Chul
    • Korean Journal of Environment and Ecology
    • /
    • v.32 no.2
    • /
    • pp.147-153
    • /
    • 2018
  • There are few available studies for insect diversity in relation to coastal dune despite the unique landscape features and high conservation value. Therefore, this study compared ground beetle assemblages inhabiting between windbreak forests and sand dunes in the Taeanhaean National Park. It investigated five windbreak forests and three coastal dunes using pitfall traps from middle of June to middle of October in 2014. A total of 2,335 ground beetles belonging to 30 species of 15 genera were collected. Synuchus arcuarticollis (158 individuals) and Dolichus halensis halensis (153 individuals) were dominant of 25 specifies collected from sand dunes while Synuchus arcuarticollis (1,630 individuals), Synuchus nitidus (130 individuals), and Synuchus cycloderus (42 individuals) were dominant of 14 species collected from windbreak forests. The similarity of ground beetles compositions in sand dunes and windbreak forests was significantly low at 27.4%. The results of this study showed that sand dune geographical features found in the Taeanhaean National Park had different insect assemblages from windbreak forests. It will be the useful information for conservation of insects in the future.

A Study on Estimating Air Pullution in the Port of Incheon (인천항의 대기오염물질 배출량 산정 연구)

  • Lee, Jeong-Uk;Lee, Hyang-Suk
    • Journal of Korea Port Economic Association
    • /
    • v.37 no.1
    • /
    • pp.143-157
    • /
    • 2021
  • International organizations such as the World Health Organization, the Organization for Economic Development and Cooperation, and major developed countries recognize the seriousness of air pollution. International organizations such as the International Maritime Organization have also implemented various regulations to reduce air pollution from ships. In line with this international trend, the government has also enacted a special law on improving air quality in port areas, and is making efforts to reduce air pollution caused by ports. The purpose of the Special Act is to implement comprehensive policies to improve air quality in port areas. This study sought to identify the emissions of each source of air pollutants originating from the port and prepare basic data on setting the policy priorities. To this end, the analysis was conducted in six categories: ships, vehicles, loading and unloading equipment, railways, unloading/wild ash dust, road ash dust, and the methodology presented by the European Environment Agency(EEA) and the United States Environmental Protection Agency(EPA). The pollutants subject to analysis were analyzed for carbon monoxide(CO), nitrogen oxides (NOX), sulfur oxides(SOX), total airborne materials(TSP), particulate matter(PM10, PM2.5), and ammonia(NH3). The analysis showed a total of 7,122 tons of emissions. By substance, NOX accounted for the largest portion of 5,084 tons, followed by CO (984 tons), SOX (530 tons), and TSP (335 tons). By source of emissions, ships accounted for the largest portion with 4,107 tons, followed by vehicles with 2,622 tons, showing high emissions. This proved to be the main cause of port air pollution, with 57.6% and 36.8% of total emissions, respectively, suggesting the need for countermeasures against these sources.

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

Geochemical Implication of Rare Earth Element from Yellow sand (Asian Dust) at Daejeon Area, Korea: A Preliminary Study for Clarifying Source Area of Yellow Sand (대전지역 황사(아시아 먼지)내 희토류원소 분포도의 지구화학적 특성-근원지 규명을 위한 초기연구)

  • Lee, Seung-Gu;Youm, Seung-Jun
    • The Journal of the Petrological Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.44-50
    • /
    • 2008
  • A geochemical technique based on rare earth element geochemistry was used to clarity the source of the Asian dust (Yellow sand) in the Daejeon area. The Asian dusts were collected 4 times during 31th March- 2nd April and 25th May-27th May 2007. The Yellow sand shows PAAS (Post Archean Australian Shale)-normalized REE pattern of the flattened LREE and slightly depleted LREE without Eu anomaly, whereas the Daejeon soil has slightly enriched LREE and depleted HREE with negative Eu anomaly. Our results show that REE patterns of the Asian dust are LREE-flattened similar to those of the sediment from the south-eastern part of Ordos desert. This suggests that Asian dust in the Daejeon area might be derived from the south-eastern part of Ordos desert.