• Title/Summary/Keyword: 체적비

Search Result 1,255, Processing Time 0.028 seconds

Volume Integral Equation Method for Problems Involving Multiple Diamond-Shaped Inclusions in an Infinite Solid under Uniaxial Tension (인장 하중을 받는 무한 고체에 포함된 다수의 다이아몬드 형 함유체 문제 해석을 위한 체적 적분방정식법)

  • Lee, Jung-Ki
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.1
    • /
    • pp.59-71
    • /
    • 2012
  • A volume integral equation method (VIEM) is introduced for the solution of elastostatic problems in unbounded isotropic elastic solids containing multiple interacting isotropic or anisotropic diamond-shaped inclusions subject to remote uniaxial tension. The method is applied to two-dimensional problems involving long parallel diamond-shaped cylindrical inclusions. A detailed analysis of the stress field at the interface between the matrix and the central inclusion is carried out for square and hexagonal packing of the inclusions. The effects of the number of isotropic or anisotropic diamond-shaped inclusions and of the various fiber volume fractions for the circular inclusions circumscribing its respective diamond-shaped inclusion on the stress field at the interface between the matrix and the central inclusion are also investigated in detail. The accuracy and efficiency of the method are examined through comparison with results obtained using the finite element method.

Numerical Study of Forced Convection Nanofluid in Double Pipe (이중관 내부 나노유체의 강제대류에 관한 수치적 연구)

  • Lim, Yun-Seung;Choi, Hoon-Ki
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.12
    • /
    • pp.147-156
    • /
    • 2019
  • Numerical study was performed to investigate the convective heat transfer of Al2O3/water nanofluid flowing through the concentric double pipe counterflow heat exchangers. Hot fluid flowing through the inner pipe transfers its heat to cooling fluid flowing in the outer pipe. Effects of important parameters such as hot and cold volume flow rates, fluid type in the outer and inner pipes, and nanoparticles concentration on the heat transfer and flow characteristics are investigated. The results indicated that the heat transfer performance increases with increasing the hot and cold volume flow rates, as well as the particle concentrations. When both outer and inner pipes are nanofluids with 8% nanoparticle volume concentration, nanofluids showed up to 17% better heat transfer rate than basic fluids. Also, the average heat transfer coefficient of the base fluid for annulus-side improved by 31%. Approximately 20% enhancement in the heat exchanger effectiveness can be achieved with the addition of 8% alumina particles in base fluid. But, addition of nanoparticles to the base fluid enhanced friction factor by about 196%.

A Study on the Fringe Visibility od the Crossed Laser Beam (교차 Lager 광선의 Fringe 시도에 관한 연구)

  • 김영권;신인철;이영노
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.4 no.4
    • /
    • pp.43-51
    • /
    • 1990
  • 레이저 비임이 대기중을 전파할 때 고류(turbulence)의 영향을 고려해야 한다. 고류의 영향에 의한 프린지 시도는 extended Huygens-Fresnel principle을 도입하여 타원체로 간주할 수 있는 프린지 체적에서 장의 전 분포를 시하고 이 전 분포로부터 평균 강도분포를 얻었으며, 평균 강도분포를 구하기 위해 Fourier-Bessel적분을 행하였다. 평균 강도분포에서 최대 평균 강도분포max 및 최소 평균 강도분포 min을 얻었으며, 이 식들을 프린지 시도의 정의 식 V=(Imax-Imax)/(Imax+Imin)에 적용하였다. 본 논문에서는 광원으로 파장 =4880[]인 아르곤 레이저를 사용하였고 광원의 모우드는 TEM..모우드로 하였다. 또한 비임의 교각 =5˚, 광원으로부터 프린지 체적 까지의 거리 L=10[m], en 광원간의 거리 B=(2tan /2)L, 특성 비임 반경 =2 /[ ( /2)]을 이용하여 프린지 시도에 관한 결과를 얻었으며, 이 결과에 의하면 L'( / ·L)에 대한 변수 r의 비 r/L'= 에서 V=1이고, r/L=0.1에서 프린지 시도가 감소한다. 또 강 고 류인 경우와 약 고 류인 경우에 대해 프린지 시도를 비교하였을 때 강 고류에서 감소폭이 크다는 사실을 알 수 있었다.

  • PDF

Volume Conserving Mesh Simplification Using Face Constriction (면 축약 방식을 이용한 체적 보존 메쉬 간략화)

  • Lee, Jun-Young;Jang, Tae-Jeong
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.42 no.5
    • /
    • pp.87-96
    • /
    • 2005
  • In this paper, a mesh simplification algorithm using face constriction is proposed which considers the conservation of the volume of a 3D model. The face constriction method replaces three vertices of the candidate triangle with a new vertex, removing four faces at once. We propose a modified method, compensating an existing method, of considering curvature in the decision of the removing order of triangles. We also propose a method of determining a new vertex replacing the candidate triangle, which reflects curvature difference of the three surrounding areas of the three vertices of the triangle, while conserving the volume. It is shown by simulation that the proposed method conserves the volume and shows good constriction performance comparable to the other methods.

Detection of Abnormal Area of Ground in Urban Area by Rectification of Ground Penetrating Radar Signal (지하투과레이더 신호의 보정을 통한 도심지 내 지반 이상구간의 검측)

  • Kang, Seonghun;Lee, Jong-Sub;Lee, Sung Jin;Lee, Jin Wook;Hong, Won-Taek
    • The Journal of Engineering Geology
    • /
    • v.27 no.3
    • /
    • pp.217-231
    • /
    • 2017
  • The subsidence of ground in urban area can be caused by the occurrence of the cavity and the change in ground volumetric water content. The objective of this study is the detection of abnormal area of ground in urban area where the cavity or the change in ground volumetric water content is occurred by the ground penetrating radar signal. GPR survey is carried out on the test bed with a circular buried object. From the GPR survey, the signals filtered by the bandpass filtering are measured, and the methods consisting of gain function, time zero, background removal, deconvolution and display gain are applied to the filtered signals. As a result of application of the signal processing methods, the polarity of signal corresponds with the relation of electrical impedance of the cavity and the ground in test bed. In addition, the relative permittivity calculated by GPR signal is compared with that of predicted by volumetric water content of the test bed. The relative permittivities obtained from two different methods show similar values. Therefore, the abnormal area where the change in ground volumetric water content is occurred can be detected from the results of the GPR survey in case the depth of underground utilities is known. Signal processing methods and estimation of relative permittivity performed in this study may be effectively used to detect the abnormal area of ground in urban area.

A Study for Characterization on Shallow Behavior of Soil Slope by Flume Experiments (토조실험 장치를 이용한 토사비탈면 표층거동 특성 연구)

  • Suk, Jae-wook;Park, Sung-Yong;Na, Geon-ha;Kang, Hyo-Sub
    • The Journal of Engineering Geology
    • /
    • v.28 no.3
    • /
    • pp.489-499
    • /
    • 2018
  • A flume experiments was used to study the characteristics of the surface displacements and volumetric water contents (VWC) during torrential rain. The surface displacement and VWC of the granite weathered soil were measured for rainfall intensity (100, 200 mm/hr) and initial ground condition (VWC 7, 14, 26%). The test processes were also recorded by video cameras. According to the test results, The shallow failure is classified into three types: retrogressive failure, progressive failure and defined failure. In the case of retrogressive failure and progressive failure, relatively large damage could occur due to the feature that soil is deposited to the bottom of the slope. the shallow failure occurred when the VWC reached a certain value regardless of the initial soil condition. It was found that the shallow failure can be predicted through the increase patton of the VWC under the condition of the ground dry condition (VWC 7%) and the natural condition (VWC 14%). For high rainfall intensity, progressive failure predominated, and rainfall intensity above a certain level did not affect wetting front transition.

Study on the Dextran and the Inner Structure of Jeung-Pyun (Korea Rice Cake) on Adding Oligosaccharide (올리고당 첨가 증편 발효 중 Dextran 형성과 증편의 내부구조에 관한 연구)

  • 이은아;우경자
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.12 no.1
    • /
    • pp.38-46
    • /
    • 2002
  • This study was carried out in order to investigate dextran formation and internal structure during fermentation of the oligosaccharide Jeung-Pyun. The dextran and sugar reducing contents of Jeung-Pyun batter and the specific volume and the internal structure of Jeung-Pyun were analyzed as a function of fermentation time. The specific volume of Jeung-Pyun peaked at the 7th hour of fermentation. The dextran content of Jeung-Pyun batters peaked at the 7~13th hour of fermentation, and Fructooligosaccharide Jeung-Pyun had the least peak value. Reducing sugar content of Jeung-Pyun batters slowly decreased as fermentation progressed. From the air pore size and distribution of Jeung-Pyun observed by SEM, the sucrose Jeung-Pyun fermented for 3~7 hours and oligosaccharide one fermented for 7 hours were judged as the best. It was concluded that dextran may be formed by fermentation of oligosaccharides as well as sucrose and dextran has a significant role on the volume expansion of Jeung-Pyun.

  • PDF

Evaluation of Crack Resistant Performance in Cement Mortar with Steel Fiber and CSA Expansion Admixture (CSA 팽창재를 혼입한 강섬유 보강 모르타르의 균열 저항성능 평가)

  • Ahn, Jung-Kil;Park, Ki-Tae;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.125-132
    • /
    • 2014
  • Steel fiber is a effective composite for crack resistance and improve structural performance under tensile loading. This study presents an evaluation of crack resistance and structural performance in cement mortar with steel fiber and expansion agent through internal chemical prestressing. For this work, cement mortar samples with 10% replacement of cement binder with CSA (Calcium-Sulfo-Aluminate) expansion agent and 1% volume ratio of steel fiber are prepared. Including basic mechanical properties, initial cracking load and fracture energy are evaluated in cement mortar beam with notch. Initial cracking load and fracture energy in cement mortar with CSA and steel fiber increase by 1.75 and 1.41~1.53 times compared with those in cement mortar with steel fiber. With optimum mix design for steel fiber and CSA expansive agent, the composite with chemical prestressing can be applied to various members and effectively improve crack resistance to external loading.

Effects of Transverse Reinforcement on Flexural Strength and Ductility of High-Strength Concrete Columns (횡보강근에 따른 고강도 콘크리트 기둥의 휨강도와 연성)

  • 황선경;윤현도;정수영
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.3
    • /
    • pp.365-372
    • /
    • 2002
  • This experimental investigation was conducted to examine the behavior of eight a third scale columns made of high-strength concrete(HSC). The columns were subjected to constant axial load corresponding to target value of 30 percent of the column axial load capacity and a cyclic horizontal load-inducing reversed bending moment. The variables studied in this research are the volumetric ratio of transverse reinforcement(Ps=1.58, 2.25 %), tie configuration(hoop-type, cross-type, diagonal-type) and tie yield strength(fy=5,600, 7,950 kgf/$\textrm{cm}^2$). Test results indicated that the flexural strength of all the columns did not exceed calculated flexural capacities based on the equivalent concrete stress block used in current design code. Columns with 42 percent higher amounts of transverse reinforcement than that required by seismic provisions of ACI 318-99 were shown ductile behavior. With axial load of 30 percent of the axial load capacity, the use of high-strength steel as transverse reinforcement may lead to equal or higher ductility than would be achieved with low-strength steel.

Numerical simulation of submerged jump and washed-out jump using the k-𝜔 SST model (k-𝜔 SST 모형을 이용한 수중도수와 잠긴흐름의 수치모의)

  • Choi, Seongwook;Choi, Sung-Uk
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.11
    • /
    • pp.1011-1019
    • /
    • 2021
  • This study presents numerical simulations of submerged jump and washed-out jump resulted from the flow over the embankment type weir. Unsteady Reynolds Averaged Navier-Stokes (URANS) equations are solved with the k-𝜔 SST turbulence model. Validations are carried out using the experimental results in the literature, revealing that computed roller shape, free surface, and mean velocity are in good agreement with measured data. The volume fractions of water of the submerged jump and washed-out jump are compared, and the characteristics of the two flows from the double-averaged volume fractions of water are presented. The condition under which the transition occurs from the submerged jump to washed-out jump is presented by the relation between the relative embankment length and submergence factor via numerical simulations by changing the weir length, discharge, and tailwater depth.