A Comparative Study on Daylighting Performance Prediction of Light Tube and Dish Concentrator (광튜브와 디쉬형 집광기의 자연채광 성능 예측 및 비교 연구)

  • Oh, Seung Jin;Han, Hyun Joo;Chun, Wongee
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.124-132
    • /
    • 2012
  • This study presents the simulation results of Photopia when a lecture room with north-facing windows were illuminated by two different types of daylighting systems to improve the imbalance in its lighting conditions. Especially, the candela power distribution curves (CDCs) on a clear sunny day at the summer solstice, reaching $80^{\circ}$ in solar altitude, were analyzed with respect to the illuminance available at task areas (work planes). The difference between its illuminance on the north and south areas exceeded 1,000 lux without any daylighting system. This, however, decreased drastically with the application of a daylighting system. When a light tube system was introduced, it reduced from 906lx to 603lx and, even further to 308lx with the application of a dish concentrator system. Generally, the performance of a light tube system was greatly influenced by solar altitude while its effect on the dish concentrator system was rather negligible.

An Evaluation of High Performance Sunlighting Mirror Systems (고성능 태양광 채광시스템의 채광성능평가)

  • Kim, J.T.;Hwang, M.K.;Chung, Y.G.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.2
    • /
    • pp.49-59
    • /
    • 2002
  • Recently, due to high rise building by rapid urbanization, the spaces incapable of being penetrated by sunlight into interior is increasing. So, sunlighting systems are important means to be able to get sunlight into indoors and to make sure of sunshine awareness. This study aims to evaluate lighting performance of sunlighting mirror systems. As results. these are very useful for the increase of an average illuminance of indoors and the penetration of sunlight. Especially, the second reflecting mirrors can be applied to spaces lack of sunlight. And these sunlighting systems developed in the present study is validated physical and psychological performance to both building and people.

A Design and Performance Evaluation of Differentiated Daylight-Glazing Systems (가변 투과시스템의 광제어 특성을 고려한 통합 채광시스템의 적용성 평가에 관한 연구)

  • Kim, Gon;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.13-22
    • /
    • 2005
  • This research aimed to generate two points of daylighting application as follows: 1) providing daylight performance data with a variety of glazing materials for a large window and 2) designing and evaluating an experimental type of differentiated window. For this purpose, we compared the daylight and distribution performance of new defined type of window configuration to the conventional window counterpart with a variety of glazing materials. The comparison was made for a deep, south-facing perimeter zone with large window, without any interior obstruction. The conventional window is the base single homogeneous glass pane, where as the differentiated window uses of two different glazings; an upper daylight glazing with high visible transmission and lower view window with lower transmittal glass. The daylight performance data was translated into a ratio between outdoor illuminance and the interiors. The simulated analysis of the conventional window indicates that the interior light levels have been changed proportionally dependent on the transmittance of the applied glass. The comparison of daylight distribution analysis showed that the differentiated window has lots of photometric advantage by the optical function of upper daylight window. In particular, the contribution of higher daylight window into deep rear space must be stressed for daylighting application.

A study on applicability of mirror reflector system in tunnel using simulation (시뮬레이션 분석을 통한 반사거울 시스템의 터널 적용성 연구)

  • Lee, Beom-Seok;Lee, Kun-Il;Jeong, In-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.5
    • /
    • pp.371-383
    • /
    • 2011
  • It is important to secure illumination for the driver's safety because the tunnel is a space for changing brightness quickly, and lighting fixtures of the tunnel have consumed a lot of electric lighting energy for operating in both the daytime and at night. This study aims to evaluate daylighting performance of Mirror Reflector System for luminous environment improvement of tunnel space by using RADIANCE simulation program. The results of simulation show that illuminance of bar type is higher than illuminance of pole type at 20 m from the tunnel entrance.

Assessment of the Daylighting Performance in Residential Building Units of South Korea through RADIANCE simulation (시뮬레이션을 이용한 주거용 건축물의 공간별 채광성능 평가)

  • Lim, Tae Sub;Lim, Hong Soo;Koo, Jae-O;Kim, Gon
    • KIEAE Journal
    • /
    • v.12 no.2
    • /
    • pp.25-32
    • /
    • 2012
  • This paper focused on the daylighting performance of residential high-rise buildings in South-Korea. the purpose of this study is to estimate the visual environment of sunlight coming into opening according to sky conditions, orientation of windows and each space of Apartment buildings. Season of the year, weather, and time of day combine with predictable movement patterns of the sun to create highly variable and dynamic daylighting conditions. Daylighting design is usually based on the dominant sky condition and the micro-climate for the building site. There are three common sky conditions: clear sky, overcast sky, and partly cloudy sky. The clear sky includes sunshine and is intense and brighter at the horizon than at the zenith, except in the area around the sun. Daylight received within a building is directly dependent upon the sun's position and the atmospheric conditions. Easily used charts, diagrams, and software programs allow study of solar geometry for any geographic location and time of day. on the other hand, the overcast sky is characterized by diffuse and variable levels of light and has dense cloud cover over 90% of the sky. This paper was calculated by a Desktop Radiance program. The space dimensions were based on a unit module of real constructed apartment having divided into five sections such as living room, room1, room2, room3 and kitchen.

Performance Assessment of Light Pipe System for the Advanced Luminous Environment of the Underground Parking Lot (지하주차장 빛환경 개선을 위한 광파이프 시스템의 채광성능 평가에 관한 연구)

  • Shin, Ju-Young;Hwang, Tae-Yon;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.1
    • /
    • pp.25-33
    • /
    • 2010
  • Use of daylight in underground space interacts with physiological need for human beings and provides relief from feeling secluded. Light pipe system can deliver natural light into the space where it is needed and can be used as primary or a secondary light source with benefits of energy, productivity and health. To use light pipe system effectively under various conditions, it is important to investigate the effectiveness of light pipe system with reliable monitoring protocol. This paper presents the results of light pipe system performance used in underground parking lot under different sky conditions. Comparisons were made between the illuminance standards of underground parking lot and the monitored data. The results indicated that adequate illuminance level was shown until 4.5m distance from the light pipe under clear sky condition. However, additional lighting device showed be used under overcast sky to meet the proper illuminance level.

Daylighting Performance of Refurbished Window System based on Site Plans in Recently-Planned Apartment Houses (공동주택의 배치유형에 따른 창호 시스템의 채광특성)

  • Kim, Gon;Roh, Ji-Woong
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.37-44
    • /
    • 2008
  • Though they have advantages in terms of aesthetic in modern architecture, however, rectangular-shaped towers causes being short of natural light due to deep interior space. There are compromised attempts to take advantages of each building shape selectively. As a result, we now witness the advent of Y-shaped, T-shaped, V-shaped and ㅈ-shaped buildings on the market. The mutative type of apartment houses usually faces southwest or southeast, which has lot of daylighting availability but anyhow, the proportion of the apartment houses which have a full south aspect. The need to verify the potential of daylighting in new building-block shapes exists. At the same time, the expansion of balcony area was legalized and thus, a visual buffer area does not exist any more. All-glass window wall on apartment houses without a balcony produces pretty harmful area with direct sunbeam. Recently, the refurbished version of conventional windows has been developed for the purposed of minimizing energy loss occurred around windows. This research initialized a series of research to deal with almost all on window wall for apartment houses. First of all, huge amount of already-designed examples of apartment houses have been analyzed in terms of floor plan, elevation, orientation and glazing materials.

Scale Model Experiments on Daylighting Performance of Topside Lighting Systems - Focused on Sun Scoop, Light Scoop and Sun Catcher Systems - (특수형 정측창 시스템의 자연채광성능에 관한 축소모형 실험 - 선 스쿠프, 라이트 스쿠프 및 선 캐처 시스템을 중심으로 -)

  • Kong, Hyo Joo;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.45-52
    • /
    • 2008
  • Daylighting systems can improve the luminous quality of indoor environment and reduce the building's electric lighting energy consumption. For designing good daylighting, place the light where it is desired and avoid excessive contrasts, glare and high light levels. Sun scoop, light scoop and sun catcher systems have been used for alternative systems compared to other natural lighting systems. This study aims to evaluate daylighting performance of sun scoop, light scoop and sun catcher systems using scale model experiments. For the purpose, the 1/10 scale models of the systems were made as the same areas of glazing(10 percent of floor area) on the top of the center roof. Totally 15 measuring points of illuminance on the horizontal work plane were monitored from 09:30 to 12:30 on October 29, 2007. Agilent data logger and photometric sensors Li-cor were used. As the results, the topside lighting systems can improve the illumination uniformity than side lighting and top lighting. However, the appropriated shading system should be integrated to prevent the direct sunlight.

A study on light pipe system technology and its application (광파이프 시스템의 조명기술 및 건축적 활용 연구)

  • Shin, Ju Young;Gon, Kim;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.9 no.1
    • /
    • pp.69-76
    • /
    • 2009
  • The use of natural light can improve the quality of indoor environment and also occupants health. In recent years, with an increasing awareness of sustainable development, various innovative methods of integrating daylight into the building have been developed. One such device is the light pipe system. The light pipes are innovative daylighting system that allow the transmission of daylight into the hard-to-reach indoor space. The system consist of mainly three parts. First, a top collector which is mounted on the outside of the roof and gathers skylight and sunlight. Second, light-reflective tube which is coated with highly reflective mirror finish material to transmit the daylight into the diffuser. Third, a diffuser which is installed on the ceiling in the room and spread the daylight into the room. Light pipes have been widely used and researched in many countries such as Australia, America, Canada and Britain. However, despite the significant daylight potential, little work have been carried out in Korea compare to the other countries. In this study, recent lighting technology and application of light pipe system in both Korea and other countries have been compared. For the results, the benefits of each light pipe system and suitable application in Korea is also discussed.

Space study on Lighting Performance For Residential Buildings By using Simulation Analysis (시뮬레이션 분석기법을 이용한 주거용 건물의 공간별 채광성능 연구)

  • Lim, Tae Sub;Lim, Jung Hee;Kim, Byung Seon
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.97-104
    • /
    • 2013
  • This proposed simulation-based design study is based on the design of residential high-rise buildings in South-Korea. the purpose of this study is to evaluate the amount of daylighting performance passing through building glazing according to sky conditions, orientation of windows and each space of Apartment buildings. The clear sky includes sunshine and is intense and brighter at the horizon than at the zenith, except in the area around the sun. Daylight received within a building is directly dependent upon the sun's position and the atmospheric conditions. Orientation of the building generally used to refer to solar orientation which is the siting of building with respect to solar access. Although any building will have different orientations for its different sides, the orientation can refer to a particular room, or to the most important facade of the building. north-facing windows receive twice the winter sun than east and west facing windows, allowing light and warmth into the home. They can be easily shaded from the high summer sun to help keep the house cool. Ideally, the glazing area should be between 10-25% of the floor area of the room. This paper was calculated by a Desktop Radiance program. The space dimensions were based on a unit module of real constructed apartment having divided into five sections such as living room, room1, room2, room3 and kitchen.