U-type Cross-Counter Indirect Evaporative Cooler made of Plastic/Paper (U형 직교 대향류 플라스틱/종이 재질 간접증발소자)

  • Kim, Nea-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.732-739
    • /
    • 2016
  • In Korea, the summer is hot and humid, and much electricity is consumed for air conditioning. Thus, the simultaneous usage of an indirect evaporative cooler and a common air conditioner could reduce the sensible heat and save electricity. This study developed a U-type cross-counter flow indirect evaporative cooler (IEC) made of plastic and paper. The efficiencies were compared with those of a cross-flow IEC. The specimen was $500mm{\times}500mm{\times}1000mm$. the results show that the indirect evaporation efficiencies of the cross-counter flow sample were 6-21% higher than those of the cross-flow sample. The pressure drops of the cross-counter sample were 51-66% higher. Thermal analysis based on the -NTU method predicted the experimental data within 10%. The electrical energy saved by the use of the cross-counter flow IEC was larger than that of the counter flow IEC, and the difference increases with the velocity. However, the the cross-counter IEC is two times larger than the cross-flow IEC, which may increase the material cost and water usage.

Heat Exchange Element Made of Plastic for Cooling of Telecommunication Cabinet (통신 함체 냉각용 플라스틱 재질의 열교환 소자)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.702-708
    • /
    • 2017
  • The heat generation rate in a telecommunications cabinet keeps increasing due to the increased usage of mobile devices. Insufficient removal of the heat increases the cabinet temperature, which results in the malfunction of the electronic devices. In this study, tests were conducted on aluminum and plastic heat exchangers for cooling a telecommunications cabinet, and the results were compared with theoretical predictions. The aluminum heat exchanger comprised counter flow parallel channels with 4.5-mm pitch, and the plastic heat exchangers comprised cross or cross-counter flow triangular channels with 2.0-mm pitch. The volume of the cross flow heat exchanger was the same as that of the aluminum heat exchanger, and the volume of the cross-counter heat exchanger was 33% larger than that of the aluminum heat exchanger. The results show that the heat transfer rate is the highest for the cross-counter heat exchanger and lowest for the aluminum one. The temperature efficiency of the cross-counter heat exchanger was 56% higher than that of the aluminum one and 20% higher than that of the cross flow heat exchanger. The pressure drop of the cross-counter heat exchanger was approximately the same as that of the aluminum one. The heat exchange efficiency was the highest for the cross-counter heat exchanger and lowest for the cross flow heat exchanger. The theoretical analysis somewhat overestimated or underestimated the data.

Frost Formation on a Cold Cylindrical Surface in Cross Flow (직교류내 원통형 냉각표면에서의 착상)

  • Lee, Kwan-Soo;Lee, Dong-Hoon;Yang, Dong-Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.8 s.227
    • /
    • pp.989-995
    • /
    • 2004
  • This paper presents a semi-empirical model to predict the frost growth formed on the cold cylinder surface. The model is composed of the correlations for frost properties including the various frosting parameters and local heat transfer coefficient. The effects of varying the correlations for local heat transfer coefficient on the frost growth are examined to establish the model. The numerical results are compared with experimental data obtained by the previous researchers. The results agree well with the experimental data within a maximum error of $13\%$. As the results, the frost thickness decreases with changing angular position from front stagnation to separation point. Also, the effects of air velocity on the frost growth are negligible, as compared to the other frosting parameters.

An Experimental Study of the Influences of Basic Design Parameters on the Performance and the Noise Characteristics of Cross-flow Fans (직교류 홴의 설계인자가 성능 및 소음 특성에 미치는 영향에 대한 실험적 연구)

  • 구형모
    • Journal of KSNVE
    • /
    • v.10 no.3
    • /
    • pp.430-436
    • /
    • 2000
  • The cross-flow fans have been widely used to constitute the air moving systems in many air-ventilating and air-conditioning units. The cross-flow fan system has many design parameters which have crucial influence on the performance and the noise characteristics of the units. As a result there are many difficulties in the design stage of the system and the general design guide has not been sufficiently established yet. This study presents the experimental results of the parametric investigation of some chosen design parameters which are directly related to the shape of the stabilizer the profile of the scroll casing and the diffusion angle of the flow exit. The results are expressed in terms of the fan performance and the specific sound pressure level characteristics. Some parameters have been found to have crucial effects on the system performance/noise characteristics and should be considered with care in the design stage.

  • PDF

원자력 발전용 직교류 핀-관 열교환기의 성능 평가

  • 김정훈;배성원;김무환;허용석
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.279-285
    • /
    • 1997
  • 본 연구에서는 나선형과 판형의 핀을 가진 원자력 발전소용 직교류 핀-관 열교환기의 열량을 ARI Standard-410에 따라 실험적으로 측정하여 풍속과 냉수속에 따른 열저항 및 압력 손실을 도출하는 것을 목적으로 하였으며, 이러한 시도를 통해서 실제 열교환기의 성능 평가시 필요한 기술적 자료를 축적하고자 하였다. 실험에서는 나선형 6fin/in, 8fin/1n, 10fin/in 열교환기와 판형 8fin/in 열교환기를 사용하였으며, 풍속을 0.486m/s와 2.214m/s로, 수속을 1m/s~4m/s로 하여 실험을 행하였다. 실험 결과를 통하여, 원자력 발전소의 격납 용기내의 공기조화를 위하여 사용되어 지는 열교환기의 성능 평가 방법 및 실증 능력을 확보하였으며, 풍속 증가에 따라 총괄 열전달 계수는 전체적으로 비례 증가하는 경향을 보였다. 판형이 나선형 보다 열전달 계수가 작게 나타났으며, 나선형 열교환기의 경우 fin수에 따른 변화는 크지 않았으나, 열전달 면적을 고려한 경우에는 나선형 10fin/in 열교환기가 가장 뛰어난 열교환 성능을 발휘함을 알 수 있었다. 또한, 공기측의 압력 손실은 전체적으로 전연 풍속 증가에 따라서 속도 제곱에 비례하여 증가하는 경향을 보였다.

  • PDF

Numerical Study on Heat Transfer Performance of Crossflow Fin-tube Heat Exchanger Depending on Different Fan Positions (직교류 핀-튜브형 열교환기에서 팬 위치변화에 따른 열전달 성능변화 연구)

  • Kim, Won Hyung;Park, Tae Seon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.271-278
    • /
    • 2015
  • The convective heat transfer of a crossflow fin-tube heat exchanger was studied numerically. In order to investigate the dependence of the heat transfer performance on the fan position, several cases with different blowing and suction types were selected for the fan position. A staggered tube arrangement was used for the heat exchanger, and the temperatures of the tube wall and air were $50^{\circ}C$ and $30^{\circ}C$, respectively. The three-dimensional flow structures were examined based on the results. In addition, the convective heat transfer coefficient and mean temperature difference between the inlet and outlet of the heat exchanger were analyzed for the various fan positions, and the heat transfer performance was investigated

Cross Flow Indirect Evaporative Cooler Made of a Plastic Film/Paper Composite (플라스틱 필름/종이 복합 재질의 직교류 간접증발소자)

  • Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.1
    • /
    • pp.21-28
    • /
    • 2017
  • Indirect evaporative cooling, which utilizes a cooling effect obtained by the evaporation of water, is energy-effective compared to the conventional vapor compression method. It is also eco-friendly, due to the non-usage of CFC refrigerant. In this study, three indirect evaporative cooler samples of the cross flow type(size: $300mm{\times}300mm{\times}300mm$, channel pitch: $5mm{\times}5mm$, $5mm{\times}7mm$, $7mm{\times}7mm$) were made using plastic/paper composites. Tests were conducted to measure indirect evaporative efficiencies and pressure drops. Results showed that the efficiency was the highest for the $5mm{\times}5mm$ sample, owing to the largest surface area. The saved electrical energy was also the greatest for that sample. The pressure drop of the wet channel was larger than that of the dry channel as expected. A theoretical model was proposed, which underestimated both the indirect evaporation efficiency and the pressure drop.