Abstract
In Korea, the summer is hot and humid, and much electricity is consumed for air conditioning. Thus, the simultaneous usage of an indirect evaporative cooler and a common air conditioner could reduce the sensible heat and save electricity. This study developed a U-type cross-counter flow indirect evaporative cooler (IEC) made of plastic and paper. The efficiencies were compared with those of a cross-flow IEC. The specimen was $500mm{\times}500mm{\times}1000mm$. the results show that the indirect evaporation efficiencies of the cross-counter flow sample were 6-21% higher than those of the cross-flow sample. The pressure drops of the cross-counter sample were 51-66% higher. Thermal analysis based on the -NTU method predicted the experimental data within 10%. The electrical energy saved by the use of the cross-counter flow IEC was larger than that of the counter flow IEC, and the difference increases with the velocity. However, the the cross-counter IEC is two times larger than the cross-flow IEC, which may increase the material cost and water usage.
Keywords
Indirect evaporative cooler; Cross-counter; Performance; Paper; Plastic;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Tejero-Gonzalez, A., Andres-Chicote, M., Velasco -Gomez, E. and Rey-Martinez, F. J., "Influence of constructive parameters on the performance of two indirect evaporative cooler prototypes," Appl. Therm. Eng., vol, 51, pp. 1017-1025, 2013. DOI: http://dx.doi.org/10.1016/j.applthermaleng.2012.10.054   DOI
2 Riangvilaikul, B. and Kumar, S., "An experimental study of a novel dew point evaporative cooling system," Energy Build., vol. 42, pp. 637-644, 2010. DOI: http://dx.doi.org/10.1016/j.enbuild.2010.07.020   DOI
3 Zhao, X., Liu, S. and Riffat, S. B., "Comparative study of heat and mass exchanging materials for indirect evaporative cooling systems," Build. Environ., vol. 43, no. 11, pp. 1902-1911, 2008. DOI: http://dx.doi.org/10.1016/j.buildenv.2007.11.009   DOI
4 Kim, N.-H., "Performance comparison between indirect evaporative coolers made of aluminum, plastic or plastic/paper," J. Korea Academia-Industrial Cooperation Society, vol. 16, no. 12, pp. 8165-8175, 2015. DOI: http://dx.doi.org/10.5762/KAIS.2015.16.12.8165   DOI
5 KS M 896, Paper and Plate - Measuremint of Water Absorption Rate in Water, 2013.
6 ASHRAE Standard 41.1, Standard Method for Temperature Measurement, ASHRAE, 1986.
7 ASHRAE Standard 41.2, Standard Method for Laboratory Air-Flow Measurement, ASHRAE, 1987.
8 KS C 9306, Air Conditioner, Korean Standard Association, 2010.
9 ASHRAE Standard 143, Method of Test for Rating Indirect Evaporative Coolers, ASHRAE, 2007.
10 Klein S. J. and McClintock, F. A., "The description of uncertainties in a single sample experiments," Mech. Eng, vol. 75, pp. 3-9, 1953.
11 Stevens, R. A., Fernandez, J. and Woolf, J. R., "Mean temperature difference in one, two and three-pass cross flow heat exchangers," Trans. ASME, vol. 79, pp. 287-297, 1957.
12 Personal communication with Samhwa Ace Co., 2016.
13 Watt, J. D. and Brown, W. K., Evaporative No. 0, Air Conditioning Handbook, 3rd ed., The Fairmont Press Inc., 1997.
14 Kays, W. M. and London, A. L., Compact Heat Exchangers, McGraw-Hill Pub., 1984.
15 Duan, Z., Zhan, C., Zhang, X., Mustafa, M. Zhao, X., Alimohammadisgvand, B. and Hasan, A., "Indirect evaporative cooling: past, present and future potentials," Renew. Sustain. Energy Rev., vol. 16, pp. 6823-6850, 2012. DOI: http://dx.doi.org/10.1016/j.rser.2012.07.007   DOI
16 Jaber, S. and Ajib, S., "Evaporative cooling as an efficient system in Mediterranean region," Appl. Therm. Eng., vol. 31, pp. 2590-2596, 2011. DOI: http://dx.doi.org/10.1016/j.applthermaleng.2011.04.026   DOI
17 Caliskan, H., Dincer, I. and Hepbasil, A., "Exergoeconomic enviroecomomic and sustainability analyses of a novel air cooler," Energy Build., vol. 55, pp. 747-756, 2012. DOI: http://dx.doi.org/10.1016/j.enbuild.2012.03.024   DOI
18 Costello, B. and Finn, D., "Thermal effectiveness characteristics of low approach indirect evaporative cooling systems in buildings," Energy Build., vol. 39, pp. 1235-1243, 2007. DOI: http://dx.doi.org/10.1016/j.enbuild.2007.01.003   DOI
19 Maheshwari, G. P., Al-Ragom, F. and Suri, R. K., "Energy saving potential of an indirect evaporative cooler," Appl. Energy, vol. 69, pp. 69-76, 2001. DOI: http://dx.doi.org/10.1016/S0306-2619(00)00066-0   DOI
20 Santamouris, M. and Kolokotsa, D., "Passive cooling dissipation techniques for buildings and other structures: the state of the art," Energy Build., vol. 57, pp. 74-94, 2013. DOI: http://dx.doi.org/10.1016/j.enbuild.2012.11.002   DOI
21 Pescod, D., "A heat exchanger for energy saving in an air conditioning plant," ASHRAE Trans., vol. 85., Pt. 2, pp. 238-251, 1979.
22 Maclaine-Cross, I. L. and Banks, P. J., "A general theory of wet surface heat exchangers and its application to regenerative cooling," J. Heat Transfer, vol. 103, pp. 578-585, 1981. DOI: http://dx.doi.org/10.1115/1.3244505
23 Kettleborough, C. F. and Hsieh, C. S., "The thermal performance of the wet surface plastic plate heat exchanger used in an indirect evaporative cooler," J. Heat Transfer, vol. 105, pp. 366-373, 1983. DOI: http://dx.doi.org/10.1115/1.3245587   DOI
24 Ren, C. and Yang, H., "An analytical model for the heat and mass transfer processes in indirect evaporative cooling with parallel/counter flow configurations," Int. J. Heat Mass Transfer, vol. 49, pp. 617-627, 2006. DOI: http://dx.doi.org/10.1016/j.ijheatmasstransfer.2005.08.019   DOI
25 Parker, R. O. and Treybal, R. E., "The heat mass transfer characteristics of evaporative coolers," Chem. Eng. Prog. Symp. Ser. vol 57, no. 32, pp. 138-149, 1962.
26 Hasan, A. an Siren, K., "Performance investigation of plain and finned tube evaporatively cooled heat exchangers," Appl. Therm. Eng., vol. 23, no. 3, pp. 325-340, 2003. DOI: http://dx.doi.org/10.1016/S1359-4311(02)00194-1   DOI
27 Zalewski, W. and Gryglaszewski, P. A., "Mathematical model of heat and mass transfer processes in evaporative coolers," Chem. Eng. Process, vol. 36, no. 4, pp. 271-280, 1977. DOI: http://dx.doi.org/10.1016/S0255-2701(97)00006-8   DOI
28 Hasan, A., "Going below the wet-bulb temperature by indirect evaporative cooling: Analysis using a modified $\epsilon$-NTU method," Appl. Energy, vol. 89, pp. 237-245, 2012. DOI: http://dx.doi.org/10.1016/j.apenergy.2011.07.005   DOI
29 Cui, X., Chua, K. J., Islam, M. R. and Yang, W. M., "Fundamental formulation of a modified LMTD method to study indirect evaporative heat exchangers," Energy Conservation Management, vol. 88, pp. 372-381, 2014. DOI: http://dx.doi.org/10.1016/j.enconman.2014.08.056   DOI
30 Chen, Y., Yang, H. and Luo, Y., "Indirect evaporative cooler considering condensation from primary air; Model development and parameter anaysis," Build. Env., vol. 95, pp. 330-345, 2016. DOI: http://dx.doi.org/10.1016/j.buildenv.2015.09.030   DOI