• Title/Summary/Keyword: 지하

Search Result 9,218, Processing Time 0.037 seconds

A Study on the Effect of Irrigation Water Temperature to the Growth and Harvest of Paddy Rice in Various Water Sources (수원별 관개용수의 수온이 수함생육과 수량에 미치는 영향에 관한 연구)

  • 조형용
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.14 no.2
    • /
    • pp.2634-2648
    • /
    • 1972
  • The aim of this Study is to bring Light on the effect of irrigation water temperature to the growth and harvest of Paddy rice in Various water Sources. 1. This research was completed in the writer's home nursery garden Located in Chungyoung-Ri, Hoeng sung-Myun, Hoengusung-Konn, Kangwan-Do. 2. The variety of Paddy rice was the IR667. 3. Practice was done by the treatment I .e river water, reservoir, tube well cold and tuke well warm with 3 riplications each. 4. The Paddy was transplanted in a pot 0.9 meter height and 1 meter Square without hottom filled with paddy soil to a planting depth 0.5 meter. The pot was laid underground and Covered with a film of polyethylene to keep of the rain. 5. The method of Cultivation was that used by the Filed Crops Experiment Station of the Office of Rural Development. 6. Atmospheric temperature was recorded every day of the growing period. The precipitation and Sun light was quoted by the KF-46 of Hoengsung. 7. The Soils in the test plots was relatively fortile, being Similar to ordinary paddy soils. 8. The charactor of irrigation water of surface and underground was both normal. 9. During the period of growth the average temperature of the underground water as $14.2^{\circ}C$ and that of the Surface was $24.1^{\circ}$. 10. The most useful water for the rice growing was that of river and reservoir while underground water was found to be generally injurious to the paddy growth because of low temperature. 11. In the case of underground water, there proved to be such harmful effects as reduction of culm length, rate of mature grain, panicle Length and grain weight and delay of tillering time, and heading time. Reading Therefore the writer conduded that the harvest of rice irrigated with underground water Showed a reduction of 15.8% compered with the rice irrigated by surface water.

  • PDF

Study on the Heat Transfer Phenomenon around Underground Concrete Digesters for Bigas Production Systems (생물개스 발생시스템을 위한 지하매설콘크리트 다이제스터의 열전달에 관한 연구)

  • 김윤기;고재균
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.22 no.1
    • /
    • pp.53-66
    • /
    • 1980
  • The research work is concerned with the analytical and experimental studies on the heat transfer phenomenon around the underground concrete digester used for biogas production Systems. A mathematical and computational method was developed to estimate heat losses from underground cylindrical concrete digester used for biogas production systems. To test its feasibility and to evaluate thermal parameters of materials related, the method was applied to six physical model digesters. The cylindrical concrete digester was taken as a physical model, to which the model,atical model of heat balance can be applied. The mathematical model was transformed by means of finite element method and used to analyze temperature distribution with respect to several boundary conditions and design parameters. The design parameters of experimental digesters were selected as; three different sizes 40cm by 80cm, 80cm by 160cm and l00cm by 200cm in diameter and height; two different levels of insulation materials-plain concrete and vermiculite mixing in concrete; and two different types of installation-underground and half-exposed. In order to carry out a particular aim of this study, the liquid within the digester was substituted by water, and its temperature was controlled in five levels-35。 C, 30。 C, 25。 C, 20。C and 15。C; and the ambient air temperature and ground temperature were checked out of the system under natural winter climate conditions. The following results were drawn from the study. 1.The analytical method, by which the estimated values of temperature distribution around a cylindrical digester were obtained, was able to be generally accepted from the comparison of the estimated values with the measured. However, the difference between the estimated and measured temperature had a trend to be considerably increased when the ambient temperature was relatively low. This was mainly related variations of input parameters including the thermal conductivity of soil, applied to the numerical analysis. Consequently, the improvement of these input data for the simulated operation of the numerical analysis is expected as an approach to obtain better refined estimation. 2.The difference between estimated and measured heat losses was shown to have the similar trend to that of temperature distribution discussed above. 3.It was found that a map of isothermal lines drawn from the estimated temperature distribution was very useful for a general observation of the direction and rate of heat transfer within the boundary. From this analysis, it was interpreted that most of heat losses is passed through the triangular section bounded within 45 degrees toward the wall at the bottom edge of the digesten Therefore, any effective insulation should be considered within this region. 4.It was verified by experiment that heat loss per unit volume of liquid was reduced as the size of the digester became larger For instance, at the liquid temperature of 35˚ C, the heat loss per unit volume from the 0. 1m$^3$ digester was 1, 050 Kcal/hr m$^3$, while at for 1. 57m$^3$ digester was 150 Kcal/hr m$^3$. 5.In the light of insulation, the vermiculite concrete was consistently shown to be superior to the plain concrete. At the liquid temperature ranging from 15。 C to 350 C, the reduction of heat loss was ranged from 5% to 25% for the half-exposed digester, while from 10% to 28% for the fully underground digester. 6.In the comparison of heat loss between the half-exposed and underground digesters, the heat loss from the former was fr6m 1,6 to 2, 6 times as much as that from the latter. This leads to the evidence that the underground digester takes advantage of heat conservation during winter.

  • PDF

Effect of Amount of Oil Cake Applications on Mineral Nutrient Partitioning of Black Chokeberry (유박시용량에 따른 유기 블랙초크베리의 수체 내 무기성분 분배에 미치는 영향)

  • Choi, Hyun-Sug;Jung, Seok-Kyu
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.28 no.1
    • /
    • pp.5-14
    • /
    • 2020
  • The study was initiated to reduce production cost and environmental pollution with the evaluation of nutrient requirement of 'Nero' black chokeberry (Aronia melanocarpa) and optimum amount of oil cake application. 100% of a recommended amount (RA) of oil cake was designated as a 100-RA, with 0-RA, 25-RA, 50-RA, and 75-RA for 0%, 25%, 50%, and 75% RA, respectively. The oil cake was scattered around the black chokeberry at every year for two years from 2018 to 2019, with investigation conducted for the second year. Soil mineral nutrient concentrations were not significantly different among the treatments. Dry weight (DW) of root and leaves was low for 0-RA-treated black chokeberry, with no significant difference observed for the all treatments for the DW of stems. 75-RA increased the fruit DW of 615 g and yield efficiency of 45.3%. Top:root ratio was the highest of 4.7 for 75-RA. Increased amount of oil cake application expanded the tree volume. Tree volume had a strong positive relationship with the root DW (r2=0.977). Mineral nutrient uptake in the root was the highest on the 25-RA-treated black chokeberry, except for Fe uptake. Mineral nutrient uptake in the leaves were similar to all the black chokeberries, except for T-N and Fe uptake. 75-RA increased mineral nutrient uptake in the fruit, except for Cu, in particular, 7.45 g in fruit N, which was the highest level compared to those of the other organs. T-N and P uptake were evenly distributed in the leaves, stems, and fruit, with high K uptake for leaves and fruit. 75-RA maximized to 17.2 g of the total nutrient uptake in a black chokeberry, with 4.9 g for the 0-RA. All mineral nutrient uptake were overall higher on the black chokeberry treated with 50-RA, 75-RA, and 100-RA compared to those of 0-RA and 25-RA.

HEARING OF RAINBOW TROUT TO COMMERCIAL SIZE IN A INDOOR AQUARIUM (실내수조를 이용한 무지개송어의 사육실험)

  • KIM In-Bae;JO Jae-Yoon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.11 no.4
    • /
    • pp.233-238
    • /
    • 1978
  • Rainbow trout were reared in a stainless steel aquarium from Nov. 11, 1977 to June 12, 1978, and the following results were obtained : 1. The volume of water was about $400\iota$ in a aquarium measuring $1m\;(Length)\times1m\;(Width)\times67cm(Height)$ and water depth 40 cm. Water was supplied for about 16 hours daily at a rate $3\iota/min$ and was drained through the conical settling part in the middle of the aquarium bottom. Filter tank was about $23cm(W)\times23cm(L)\times40cm(D)$ and contained pebbles 30 cm in depth. Water recirculation rate was at)out $1,030\iota/hr$, or 2.6 turn-over per hour. 2. During the first period (77 days), the trout grew from 88.3g to 229g in average, the total weight attaining 30.7kg. The food coefficient was 1.249, average daily increment 243.3g, average daily growth rate 1.245%, and the mortality was 2 smallest fish weighing 53 g, owing to unknown reason. During the second period (135 days), the trout grew from 239g to 555g in average, the total weight attaining 57.2 kg. The food coefficient was 1.447, average daily increment 279.8g, average daily growth rate $0.65\%$ and the mortality was 31 fish weighing 11,255 g, owing partly to miss-handling and partly to disease. 3. The feed consisting of fully domestic materials was prepared in this laboratory, and the feed conversion was not inferior to high protein commercial feed available in foreign countries. 4. The result of whole period for 212 days was 56.5 kg in gross increment, and based on this result, when $1\iota/min$ full day inflowing water available, the net production will become 28.25 kg. So, if a 5000kg production is planned, $180\iota/min$ or about $10.8m^3/hr$ be reauired, and the production in value frill become 15million won at local price at the expense of about 5.3 million won. From the result of this experiment, rainbow trout is feasible for commercial production in Korea with relatively small amount of well water and simplified water recirculation system.

  • PDF

Carbon Storage and Uptake by Deciduous Tree Species for Urban Landscape (도시 낙엽성 조경수종의 탄소저장 및 흡수)

  • Jo, Hyun-Kil;Ahn, Tae-Won
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.160-168
    • /
    • 2012
  • This study generated regression models to estimate the carbon storage and uptake from the urban deciduous landscape trees through a direct harvesting method, and established essential information to quantify carbon reduction from urban greenspace. Tree species for the study included Acer palmatum, Zelkova serrata, Prunus yedoensis, and Ginkgo biloba, which are usually planted as urban landscape trees. Tree individuals for each species were sampled reflecting various diameter sizes at a given interval. The study measured biomass for each part including the roots of sample trees to compute the total carbon storage per tree. Annual carbon uptake per tree was quantified by analyzing radial growth rates of stem samples at breast height. The study then derived a regression model easily applicable in estimating carbon storage and uptake per tree for the 4 species by using diameter at breast height(dbh) as an independent variable. All the regression models showed high fitness with $r^2$ values of 0.94~0.99. Carbon storage and uptake per tree and their differences between diameter classes increased as the diameter sizes got larger. The carbon storage and uptake tended to be greatest with Zelkova serrata in the same diameter sizes, followed by Prunus yedoensis and Ginkgo biloba in order. A Zelkova serrata tree with 15cm in dbh stored about 54kg of carbon and annually sequestered 7 kg, based on a regression model for the species. The study has broken new grounds to overcome limitations of the past studies which substituted, due to a difficulty in direct cutting and root digging of urban landscape trees, coefficients from the forest trees such as biomass expansion factors, ratios of below ground/above ground biomass, and diameter growth rates. Study results can be useful as a tool or skill to evaluate carbon reduction by landscape trees in urban greenspace projects of the government.

A Study on Development of Freshwater Fish Shelter and Evaluation of Water Quality for the Reduction of Thermal Stress in Shallow Pond (얕은 연못에서 담수 어류의 열성 스트레스 저감을 위한 피난처 개발 및 수질환경 조사 연구)

  • Lee, Saeromi;Ahn, Chang Hyuk;Joo, Jin Chul;Song, Ho Myeon;Park, Jae Roh
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.12
    • /
    • pp.828-836
    • /
    • 2014
  • The purpose of this study evaluates the water quality of artificial deep pool (ADP) during the late spring and summer. we monitored the water quality, as pH, dissolved oxygen (DO), temperature and conductivity at two stations (St. 1. open water, St. 2. in the ADP). The water quality in the ADP is very stable, and temperature and DO are lower than the open water (average value; temperature $1.4{\sim}3.2^{\circ}C$, DO 2.4~3.6 mg/L). In particular, daily variation of temperature in the open water showed above $4^{\circ}C$, but ADP remained stable. The water quality was analyzed using two-way analysis of variance (ANOVA). The results of the analysis showed difference about temperature, pH, DO, conductivity (two-way ANOVA, p<0.05). The ADP has created an aqua environment in thermal and DO gradients by depth. About 1.2 m, Temperature and DO were sharply decreased. The Rhodeus uyekii is dominant species in pond of this study. The ADP offers optimum water temperature ($16.5{\sim}18.5^{\circ}C$) to the Rhodeus uyekii about spawning. Consequently, the ADP offers stable habitat than open water for fish and aquatic organisms during the summer. It is also a good shelter for fish from a thermal stress.

Analysis of the Characteristics of the Seismic source and the Wave Propagation Parameters in the region of the Southeastern Korean Peninsula (한반도 남동부 지진의 지각매질 특성 및 지진원 특성 변수 연구)

  • Kim, Jun-Kyoung;Kang, Ik-Bum
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.1 s.4
    • /
    • pp.135-141
    • /
    • 2002
  • Both non-linear damping values of the deep and shallow crustal materials and seismic source parameters are found from the observed near-field seismic ground motions at the South-eastern Korean Peninsula. The non-linear numerical algorithm applied in this study is Levenberg-Marquadet method. All the 25 sets of horizontal ground motions (east-west and north-south components at each seismic station) from 3 events (micro to macro scale) were used for the analysis of damping values and source parameters. The non-linear damping values of the deep and shallow crustal materials were found to be more similar to those of the region of the Western United States. The seismic source parameters found from this study also showed that the resultant stress drop values are relatively low compared to those of the Western United Sates. Consequently, comparisons of the various seismic parameters from this study and those of the United States Seismo-tectonic data suggest that the seismo-tectonic characteristics of the South eastern Korean Peninsula is more similar to those of the Western U.S.

The Consideration about Heavy Metal Contamination of Room and Worker in a Workshop (공작실에서 실내 및 작업종사자의 중금속 오염도에 관한 고찰)

  • Kim Jeong-Ho;Kim Gha-Jung;Kim Sung-Ki;Bea Suk-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.87-94
    • /
    • 2005
  • Purpose : Heavy metal use when producing the block from the workshop. At this time, production of heavy metal dust and fume gives risk in human. This like heavy metal to improve seriousness through measurement and analysis. And by the quest in solution is purpose of this thesis. Materials and Methods : Organization is Inductively Coupled Plasma Atomic Emission Spectrometer, and the object is Deajeon city 4 workshops in university hospital radiation oncology (Bismuth, Lead, Tin and cadmium). Method is the ppb the pumping it does at unit, comparison analysis. And the Calculation heavy metal standard level in air through heavy metal standard level in body and blood, so Heavy metal temporary standard set. Results : Subterranean existence room air quality the administration laws appointed Lead and Cadmium's exposure recommend that it is $3{\mu}g/m^3\;and\;2{\mu}g/m^3$. And Bismuth and Tin decides $7{\mu}g/m^3\;and\;6{\mu}g/m^3$ through standard level in air heavy metal and standard level in body and blood. Heavy metal measurement level of workshops in 4 university hospital Daejeon city compares with work existence and nonexistence. On work nonexistence almost measurement level is below the recommend level. But work existence case express high level. Also consequently in composition ratio of the block is continuous with the detection ratio. Conclusion : Worker's heavy metal contamination imbrued serious for solution founds basic part. In hospital may operation on local air exhauster and periodical efficiency check, protector offer, et al. And worker have a correct understanding part of heavy metal contamination, and have continuous interest, health control. Finally, learned society sphere administer to establishment standard level and periodical measurement. And it founds basic solution plan of periodical special health checkup.

  • PDF

Analysis of the Environmental Radiation Dose Measured at the University Located in Suwon City (수원시 소재의 한 대학 내 환경방사선량 측정 분석)

  • Lee, In-Ja;Jeong, Yu-Jin;Kim, Chung-Kyung;Kim, Hee-Sol;Yoon, Hyeo-Min;Park, Da-Jeong;Ko, Yo-Han
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.233-238
    • /
    • 2014
  • The amount of environmental radiation was measured in the indoor(basement) and outdoor(rooftop) of the two buildings of the University (the old building and the new building) in Suwon City, Gyeonggi Province. Measuring the environmental radiation dose from the first week of April 2013 to last week of March 2014, Twice a week, one year. The measured results were as follows. 1. The average annual environmental radiation of the two buildings were $0.169727{\mu}Sv/hr$. The lowest value was $0.0760{\mu}Sv/hr$ whereas the highest value was $0.3000{\mu}Sv/hr$. 2. The amount of environmental radiation dose was $0.176373999{\mu}Sv/hr$ in the old building and the amount of environmental radiation dose was $0.163052885{\mu}Sv/hr$ in the new building. The old building environmental radiation dose was higher then the new building. 3. The month of the lowest amount of environmental radiation dose in a year was November resulting in $0.152844{\mu}Sv/hr$ whereas May was found the month of the highest amount of environmental radiation dose showing with $0.197222{\mu}Sv/hr$. 4. The amount of environmental radiation dose in the indoor(basement) was $0.164649{\mu}Sv/hr$ and the amount of environmental radiation dose of the outdoor(rooftop) was $0.174779{\mu}Sv/hr$. And the outdoor(rooftop) was higher than the indoor(basement). 5. Depending on seasonal, the lowest amount of environmental radiation dose was in winter with $0.1632{\mu}Sv/hr$ while spring was the season with the highest amount of environmental radiation dose with $0.183846{\mu}Sv/hr$. The measured amount was high in the order of spring, summer, autumn, and winter.

The Synthetic Study of Environmental Contamination at the Seokdae Municipal Waste Landfill in Pusan (부산 석대 생활폐기물 매립장의 환경오염에 대한 종합적 연구)

  • 김병우;정상용;이민희;이병헌
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.98-103
    • /
    • 2001
  • In order to understand the characteristics of leachate at the Seokdae municipal waste landfill in the Pusan city, the correlation between leachate pollution loading and volume of gas production. concentration of gas and subsidence of ground, the characteristical methos, geochemical analyses and laboratory column tests using samples of gases, leachate and surface soil of Seokdae waste landfill area. Through the analysis of water balance, leachate flow rate and pollution loading were estimated. Geistatistical analysis of four gas components ( $O_2$, C $H_4$, $H_2$S and CO) shows the possibility of ground subsidence around the group of a site with high concentration of gas. From geochemical analyses of leachate, EC and Total-Alkalinity of ground subsidence around the group of a site with high concentration of gas. From geochemical analysis of leachate, Ec and Total-Alkalinity were increased, and Cl, Cr, Mn, Cu, Zn, Cd and Pb were decreassed comparing to the part, and the type of water quality was Na-HC $O_3$ in trilinear diagram. It shows that biodecomposition of municipal wastes continues actively. From the analysis of water balance, the total leachate flow rate is about 465.11㎥/day and pure pollution loading of Cl, Mn and Fe are estimated to 223.8kg/day, 0.2kg/day, 0.3kg/day, respectively. The laboratory column test of residual soil and landfill soil shows 0.206cm and 0.019cm for linear velocity(equation omitted), 0.234 $\textrm{cm}^2$/min and 0.018$\textrm{cm}^2$/min for diffusion coefficient ( $D_{ι}$), and 1.136cm and 0.095cm longitudinal dispersion index ($\alpha$$_{ι}$), respective]y. It demonstrates that the delay time of contamination for residual soil is shorter than that of landfill soil.

  • PDF