• Title/Summary/Keyword: 지대주

Search Result 843, Processing Time 0.022 seconds

3-D Finite element stress analysis in screw-type, cement-type, and combined-type implant fixed partial denture designs (임플란트 상부보철물의 유지형태에 따른 3차원 유한요소 응력분석)

  • Lee, Sung-Chun;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.365-375
    • /
    • 2009
  • Statement of problems: Stress analysis on implant components of the combined screw- and cement-retained implant prosthesis has not investigated yet. Purpose: The purpose of this study was to assess the load distribution characteristics of implant prostheses with the different prosthodontic retention types, such as cement-type, screw-type and combined type by using 3-dimensional finite element analysis. Material and methods: A 3-dimensional finite element model was created in which two SS II implants (Osstem Co. Ltd.) were placed in the areas of the first premolar and the first molar in the mandible, and three-unit fixed partial dentures with four different retention types were fabricated on the two SS II implants. Model 1 was a cement-retained implant restoration made on two cement-retained type abutments (Comocta abutment; Osstem Co. Ltd.), and Model 2 was a screw-retained implant restoration made on the screw-retained type abutments (Octa abutment; Osstem Co. Ltd.). Model 3 was a combined type implant restoration made on the cement-retained type abutment (Comocta abutment) for the first molar and the screw-retained type abutment (Octa abutment) for the first premolar. Lastly, Model 4 was a combined type implant restoration made on the screw-retained type abutment (Octa abutment) for the first molar and the cement-retained type abutment (Comocta abutment) for the first premolar. Average masticatory force was applied on the central fossa in a vertical direction, and on the buccal cusp in a vertical and oblique direction for each model. Von-Mises stress patterns on alveolar bone, implant body, abutment, abutment screw, and prosthetic screw around implant prostheses were evaluated through 3-dimensional finite element analysis. Results: Model 2 showed the lowest von Mises stress. In all models, the von Mises stress distribution of cortical bone, cancellous bone and implant body showed the similar pattern. Regardless of loading conditions and type of abutment system, the stress of bone was concentrated on the cortical bone. The von-Mises stress on abutment, abutment screw, and prosthetic screw showed the lower values for the screw-retained type abutment than for the cement-retained type abutment regardless of the model type. There was little reciprocal effect of the abutment system between the molar and the premolar position. For all models, buccal cusp oblique loading caused the largest stress, followed by buccal cusp vertical loading and center vertical loading. Conclusion: Within the limitation of the FEA study, the combined type implant prosthesis did not demonstrate more stress around implant components than the cement type implant prosthesis. Under the assumption of ideal passive fit, the screw-type implant prosthesis showed the east stress around implant components.

Variations in Growth Characteristics and Seed Qualities of Korean Soybean Landraces (한국 재래종 콩의 수집지대별 생태적 특성 및 품질 차이)

  • Han, Won-Young;Park, Keum-Yong;Kim, Hyun-Tae;Ko, Jong-Min;Baek, In-Youl;Lee, Chung-Yeol;Choung, Myoung-Gun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.spc
    • /
    • pp.96-102
    • /
    • 2008
  • This study was carried out to examine agronomic characteristics and seed qualities of 827 Korean soybean landraces according to the collecting areas. Agronomic characteristics and seed qualities was examined according to the localities by weather characteristics. Days to flowering was the longest (mean 70.9 days) in the northwest seashore, and the most short in the south inland (mean 63.8 days). Growth days was the longest in the Gyeongbuk inland (mean 136.0 days), and the most short in the mountain-high (mean 132.8 days). The stem height was the most short in the north-west seashore (mean 81.3 cm), and in the south seashore (mean 58.8 cm). The seed weight of 100 seeds was the lightest in the north-west seashore (mean 17.1 g), and the heaviest in the south-west seashore (mean 21.5 g). The crude protein contents was the lowest in the north-west seashore (mean 40.1%), the highest in the south seashore (mean 42.8%), and vice versa in the crude oil. The contents of sucrose and oligo-saccharide was the highest 5.8% and 8.6%, respectively, in the mountain-high, and the lowest 4.8% and 7.6% in the Gyeongbuk inland and south seashore, respectively. Among the iso-flavone contests, the contents of genistein and total was the highest, $635.6\;{\mu}g/g$ and $1258.1\;{\mu}g/g$, respectively, in the mountain inland, and the lowest $319.2\;{\mu}g/g$ and $835.3\;{\mu}g/g$ in the south-west seashore. The contents of glycitein was the highest $124.3\;{\mu}g/g$ in the south seashore.

Reconstruction of upper anterior by implant using customized zirconia abutment and all ceramics: a clinical report (맞춤형 지르코니아 지대주와 완전도재관을 이용한 상악 전치부 임플란트 보철 수복)

  • Kim, Ja-Yeong;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.81-92
    • /
    • 2014
  • It is so hard to obtain optimal anterior esthetics in the implant prosthesis. This is not only because of hard and soft tissue problem such as alveolar bone resorption and interdental papilla loss but also because of prosthetic limitation related to marginal exposure of metal abutment and metal ceramics and low transillumination. In this case, guided soft tissue healing is obtained using a long term provisional restoration with soft and hard tissue augmentation or immediate implantation. Then, this healed tissue is transferred to final master model using a customized impression coping and the implant is restored with a customized zirconia abutment and a all ceramics. This case presents satisfying result esthetically and functionally.

Joint stability of internal conical connection abutments with or without hexagon indexes: an in vitro study (내부연결 원추형 임플란트의 육각구조의 유무에 따른 연결부 안정성: 실험적 연구)

  • Lee, Sang-Woon;Cha, Min-Sang;Lee, Ji-Hye;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.95-103
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the axial displacement of the hexagonal and conical abutment in internal conical connection implant after screw tightening and cyclic loading. Materials and Methods: Internal conical connection implants were divided into two groups (n = 10): group HEX, hexagonal abutment; and group CON, conical 2-piece abutments. The axial displacement and removal torque values were measured after 30 Ncm torque tightening and 250N loading test of 100,000 cycles. The Student t test with 5% significance level was used to evaluate the data. Results: HEX group demonstrated significantly higher axial displacement values after 30 Ncm tightening in comparison to the CON group (P < 0.05). No significant difference was found in axial displacement after cyclic loading (P = 0.052). Removal torque loss before and after the cyclic loading both revealed no significant difference between groups (P = 0.057 and P = 0.138). Removal torque value decreased after cyclic loading in both groups (P < 0.05). Conclusion: Overall, both abutment with or without hexagon index presented similar biomechanical performance except HEX group demonstrated significantly more axial displacement after applying tightening torque.

Effects of anaerobic sealing agents on preload maintenance of screw-retained implant prosthesis with surface of screws (임플란트 보철물 나사의 전하중 유지에 나사 표면에 따른 혐기성 나사 고정제의 효과)

  • Ryu, Seung-Beom;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.103-109
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the preload maintenance of the retaining screw when using anaerobic sealing agents in implant fixture and abutment components. Specifically, the study examines the effects of anaerobic sealing agents on different types of screws. Materials and methods: External hexagon implants made of titanium and anti-rotational abutments were used. Titanium abutment screws and ebony abutment screws from the same manufacturer were used. The experiment was divided into four groups (n = 10 in each group). In the control group, no sealing agent was used at the implant fixture and abutment screw interface. All abutment screws were tightened according to the manufacturer's recommended torque (30 N.cm). After 24 hours, the removal torque (detorque) of each screw was measured using a digital torque gauge device. The data were analyzed by two-way ANOVA test according to normality distribution satisfaction. Results: Looking at the results for each group, titanium screws and no treatment showed detorque values of 20.3 ± 1.6 N.cm. titanium screws and applied anaerobic sealing agent showed detorque values of 32.4 ± 6.7 N.cm. Ebony screws and no treatment showed detorque values of 20.2 ± 1.5 N.cm. ebony screws and applied anaerobic sealing agent showed detorque values of 30.4 ± 4.5 N.cm. Conclusion: The detorque value was higher in the case of using anaerobic sealing agents in both the titanium screw and ebony screw groups. But there was no difference between the two screws.

Influence of Tungsten Carbide/Carbon Coating on the Preload and Tightening Torque of Implant Abutment Screws (임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이 전하중 및 조임회전각에 미치는 영향)

  • Shin, Hyon-Mo;Cho, Wook;Jeong, Chang-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.53-59
    • /
    • 2009
  • The purpose of this study was to clarify the clinical efficiency of tungsten carbide/carbon coating on obtaining optimal preload of abutment screw compared with non-coated screw in external-hex implant system. In the present work, rotational value and the compressive force between abutment and fixture of abutment screws without coating and with coating tightened to 30Ncm were measured. Mean compressive force of coated screw was 504.6N. Then uncoated screw was tightened to clamping the abutment and the implant to 504.6N, and the tightening torque value and the rotational value was recorded. The following conclusions were drawn within the limitation of this study. Compressive force of coated screw was higher than that of uncoated screw after tightening at 30Ncm. The tightening torque that was nedeed to clamping the uncoated screw equal to coated screw tightened to 30Ncm was 55.6Ncm. In case of equal compressive force, there was no significant difference in rotation value between coated and uncoated screw.

Implant-supported fixed prostheses with high-performance polymer (PEKK) abutments in partial edentulous patients: A case report (부분 무치악 환자에서 고기능성 폴리머(PEKK) 지대주를 이용한 임플란트 고정성 보철물 수복 증례)

  • Ha, Seung-Ryong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.71-78
    • /
    • 2021
  • Implant treatment, which was first attempted in fully edentulous patients, is now widely used in partially edentulous, and a single tooth missing patients. Moreover, implant treatment has become an essential treatment modality in modern dentistry. The material of fabricating implant prostheses has also become more diverse than before, one of which is the use of high-performance polymers. The frequency of using high-performance polymers, which have been used in the medical field, is also increased in the dental field compared to the past. In the first case, a PEKK abutment and a PFG crown (cement-screw-retaining type) were fabricated in the lower left second premolar, and in the second case, a PEKK abutment and a monolithic zirconia crown (cement-screw-retaining type) were fabricated in the missing upper left first molar, and in the third case two PEKK abutments and a splinted PFM crowns (cement-screw-retaining type) were fabricated and connected to the upper right first and second molar implants. Through these procedures the patients obtained esthetically and functionally satisfactory results after 4 years of follow-up.

DSP-based Object Recognizer Design (DSP 기반 Object Recognizer 설계)

  • Seong-Yoon Shin;Seung-Pyo Cho;Gwanghung Jo
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2023.07a
    • /
    • pp.639-640
    • /
    • 2023
  • 차량에는 사각지대가 운전자에게 쉽게 보이지 않으며, 안전지대를 보이게 하는 시스템이 많이 있다. 본 논문에서는 사각지대 차량 안전 지원 시스템의 사물인식 개발을 위한 요구사항, 사물인식 네트워크 구조, 훈련기법에 대해 살펴본다.

  • PDF

3-D FEA of three different single tooth abutments : Cement-retained Vs Screw-retained (3종의 단일치아 수복용 지대주의 삼차원 유한요소법적연구 : 시멘트 유지헝 대 나사 유지형)

  • Lee, Jung-Min;Kim, Yung-Soo;Kim, Chang-Whe;Kim, Yong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.269-288
    • /
    • 1999
  • 현재 골 유착성 임플랜트는 안전하고 유용한 보철 수복 분야의 하나로 자리잡아 가고있다. 과거 완전 무치악 환자에게 있어서 저작 기능의 회복이란 면에 중점을 두었던 경향에서 현재 골유착 임플랜트의 높은 성공률에 의해 부문 무치악, 단일치 수복에 까지 다양하게 사용되고 있다. 특히 심미성과 인접치의 손상을 가하지 않는다는 면에서 단일치 수복에서 골유착 임플랜트 치료에 관심이 모아지고 있다. 단일치 수복에 있어서 심미성이 중요한 문제로 대두되면서 이런 수복에 사용될 수 있는 다양한 계통의 임플랜트들이 개발되어 사용되고 있다. 이중 가장 기본적인 Branemark 계통의 CeraOne 지대주, 최근에 개발된 전부도재 지대주인 CerAdapt 전부주조 지대주인 UCLA 계통등은 높은 성공률을 보이며 많이 사용되고 있다. 임상가들에 의해 나사유지형 보철물이 착탈성이란 관점에서 선호되고 있다. 시멘트유지형 보철물에서는 나사공이 없는 온전한 교합면을 유지한다는 면과 교합력을 받는 면적에 있어서 더 넓은 면을 가진다는 점등 더 많은 장점을 가진다고 주장하는 사람도 있다. 임상가들의 기호에 의해 선택되어지는 나사 유지형과 시멘트 유지형에 있어서 교합력이 야기하는 하중하에서 각각의 응력 분포를 분석할 필요성이 요구되었다. 이 연구는 단일치 수복에 사용되는 CeraOne, CerAdapt UCLA 계통에서 각각의 나사 유지형과 시멘트유지형에서의 응력분포를 삼차원 유한요소법으로 분석하고 상부 구조물에 가해지는 수직하중, 수평 하중, 경사 하중에 의해 야기되는 응력을 비교 분석한 것이다. 본 연구의 연구 결과는 다음과 같다. 1. CeraOne, CerAdapt, UCLA 지대주 모두 시멘트유지형보다 나사유지형에서 응력집중이 컸다. 2. CeraOne 시멘트유지형인 1번 모델에서 응력분산이 유리하였고, UCLA 나사 유지형인 6번 모델에서 가장 불리하였다. 3. 모든 모델에서 고정체 경부에서 가장 큰 응력 집중이 있었고 이것은 UCLA 지대주에서 가장 컸다. 4. 상부 구조물에서 주된 응력의 집중은 교합면에서 일어났다. 5. 골은 상부 피질골, 즉 고정체경부와 만나는 부위에서 가장 큰 응력의 집중이 일어났으며 수평, 경사 하중시 응력집중 양상은 힘을 가한 쪽의 반대쪽 고정체 경부에 응력이 집중되는 양상을 보였다. 6. 전체 모델과 골, 고정체 모두에서 수평 하중과 경사 하중시 보다는 수직 하중시 더 적은 응력값을 보였다.

  • PDF

The non-linear FEM analysis of different connection lengths of internal connection abutment (내측 연결형 임플란트 지대주의 체결부 길이 변화에 따른 비선형 유한요소법적 응력분석)

  • Lee, Yong-Sang;Kang, Kyoung-Tak;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.110-119
    • /
    • 2016
  • Purpose: This study is aimed to assess changes of stress distribution dependent on different connection lengths and placement of the fixture top relative to the ridge crest. Materials and methods: The internal-conical connection implant which has a hexagonal anti-rotation index was used for FEM analysis on stress distribution in accordance with connection length of fixture-abutment. Different connection lengths of 2.5 mm, 3.5 mm, and 4.5 mm were designed respectively with the top of the fixture flush with residual ridge crest level, or 2 mm above. Therefore, a total of 6 models were made for the FEM analysis. The load was 170 N and 30-degree tilted. Results: In all cases, the maximum von Mises stress was located adjacent to the top portion of the fixture and ridge crest in the bone. The longer the connection length was, the lower the maximum von Mises stress was in the fixture, abutment, screw and bone. The reduction rate of the maximum von Mises stress depending on increased connection length was greater in the case of the fixture top at 2 mm above the ridge crest versus flush with the ridge crest. Conclusion: It was found that the longer the connection length, the lower the maximum von Mises stress appears. Furthermore, it will help prevent mechanical or biological complications of implants.