Abstract
The purpose of this study was to clarify the clinical efficiency of tungsten carbide/carbon coating on obtaining optimal preload of abutment screw compared with non-coated screw in external-hex implant system. In the present work, rotational value and the compressive force between abutment and fixture of abutment screws without coating and with coating tightened to 30Ncm were measured. Mean compressive force of coated screw was 504.6N. Then uncoated screw was tightened to clamping the abutment and the implant to 504.6N, and the tightening torque value and the rotational value was recorded. The following conclusions were drawn within the limitation of this study. Compressive force of coated screw was higher than that of uncoated screw after tightening at 30Ncm. The tightening torque that was nedeed to clamping the uncoated screw equal to coated screw tightened to 30Ncm was 55.6Ncm. In case of equal compressive force, there was no significant difference in rotation value between coated and uncoated screw.
Keywords
preload; tightening torque; tungsten carbide/carbon coating;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Branemark P-I, Hansson BO, Adell R, Breine U, Lindstrom J, Hallen O, Ohman A. Osseointegrated implants in the treatment of the edentulous jaw: Experience from a ten year period. Scand J Plastic Reconst Surg 1977;11(suppl)
2 Adell R, Lekholm U, Rockler B, Branemark P-I. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416   DOI   PUBMED
3 Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Tronto study. Part II: The prosthetic results. J Prosthet Dent 1989;64:53-61
4 Rangert B, Jemt T, Jrnus L. Forces and moments on Branemark implants. Int J Oral Maxillofac Implants 1989:4:241-247
5 Shigley J. Mechanical Engineering Design,ed 3. New York: McGraw Hill, 1987:227-52
6 Robb TT, Porter SS. Increasing implantabutment preload by thin gold coating abutment screws [abstract 1642]. J Dent Res 1998;77(special issue):837
7 Rangert B, Sullivan R. Learning from history The transition from full arch to posterior partial restorations. Nobelpharma News 1995;9(2):67
8 McGlumphy EA, Mendel DA, Holloway JA. Implant Screw Mechanics. Dent Clinics North Am 1998; 42:71-89   PUBMED
9 Jemt T. Modified single and short-span restorations supported by osseointegrated fixtures in the partially edentulous jaw. J Prosthet Dent 1986;55:243-7   DOI   PUBMED   ScienceOn
10 Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Tronto study. Part III: Problems and complications encountered. J Prosthet Dent 1990;64:185-194   DOI   ScienceOn
11 Motosh N. Development of design charts for bolts preloaded up to the plastic range. J Eng Ind 1976;98:849-51
12 Choi JU, Jeong CM, Jeon YC, Lim JS, Jeong HC, Eom TG. Influence of tungsten carbide/carbon http://searchc.naver.com/ntk/coating on the preload of implant abutment screws. J Korean Acad Prosthodon 2006;44:229-42
13 Park JK, Jeong CM, Jeon YC, Yoon JH. Influence of tungsten carbide/carbon coating of implant-abutment screw on screw loosening. J Korean Acad Prosthodon 2008;46:137-47
14 Martin WC, Woody RD, Miller BH, Miller AW. Implant abutment screw rotations and preloads for four different screw materials and surfaces. J Prosthet Dent 2001;86:24-32   DOI   ScienceOn
15 Albrektsson T. A multicenter report on osseointegrated oral implants. J Prosthet Dent 1988;60:75-84   DOI   PUBMED   ScienceOn
16 Jemt T, Lekholm U, Grondahl K. 3-year followup study of early single implantb restorations ad modum Branemark. Int J Periodontics Restorative Dent 1990;10:340-9
17 Schwarz MS. Mechanical complications of dental implants. Clin Oral Impl Res 2000;11:156-8   DOI   ScienceOn
18 Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Tronto study. Part I: Surgical results. J Prosthet Dent 1990;63:451-457   DOI   ScienceOn
19 Jaarda MJ, Razzoog ME, Gratton DG. Effect of preload torque on the ultimate tensile strength of implant prosthetic retaining screws. Implant Dent 1994;3:17-21   DOI   PUBMED   ScienceOn
20 Liu Y, Gubisch M, Hild W, Scherge M, Spiess L, Knedlik Ch, Schaefer JA. Nanoscale multilayer WC/C coatings developed for nanopositioning. part II: Friction and wear. Thin Solid Films 2005;488: 140-8   DOI   ScienceOn
21 Misch CE, Wang HL, Misch CM, Sharawy M, Lemons J, Judy KW. Rationale for the application of immediate load in implant dentistry: Part I. Implant Dent 2004;13:207-17   DOI   ScienceOn
22 Vigolo P. Cemented versus screw-retained implant- supported single tooth crowns: A 4-year prospective clinical study. Int. J Oral Maxillofac Implants 2004; 19:260-5
23 Robb TT, Porter SS. Increasing abutment screw rotation by applying a thingold coating [abstract 1641]. J Dent Res 1998;77(special issue):837