• 제목/요약/키워드: 조직 변화

Search Result 6,507, Processing Time 0.049 seconds

Analysis of Urinary Mass Screening for Elementary, Middle and High School Children Over a 3-year Period(1995-1997) in Seoul (서울지역내 초.중.고 학생들에 실시된 3년 동안의($1995{\sim}1997$) 집단뇨검사 결과 분석)

  • Kang Ho-Seok;Lee Chong-Guk
    • Childhood Kidney Diseases
    • /
    • v.3 no.2
    • /
    • pp.161-169
    • /
    • 1999
  • Purpose : The urinary mass screening program for the detection of proteinuria in school aged population has been performed in Seoul since 1981. Systematic evaluation in corporation with the Seoul School Health Center for students with proteinuria identified in the mass screening has been performed from 1987. The results of urinary mass screening up to 1994 was reported. I report here the results of urinary mass screening from 1995 to 1997 and compare them with previous results and attempt to reveal the significance of urinary mass screening. Objects and Methods : In the 3-year period between 1995 and 1997, annually about 460,000 students comprising 3 different age groups; 5th grade of elementary school, 2nd grade of middle school and 2nd grade of high school were chosen, corresponding to the approximate ages of 11, 14, and 17 years, respectively. These subjects accounted for 26% of total school aged children in Seoul. The screening program was carried out in 3 steps. The 1st test was performed with dipstick at school and the 2nd at the Seoul School Health Center. Those students who showed proteinuria in the 1st and 2nd tests were referred to the hospital. Laboratory examinations including renal biopsies were performed to those students with pathologic proteinuria to clarify the incipient renal diseases. Results : 1) The prevalence of asymptomatic proteinuria was 0.28% in the 1st test. It peaked at the group of 14 years old as 0.34%, compared with 0.26% at the group of 11 years old and 0.24% at the group of 17 years old. It reached to 0.26% in male and 0.30% in female. 2) 25 percent of those having proteinuria at the first test were positive at the second test. 3) The proportion of patients with proteinuria by 3rd test were as follows; 25% of transient proteinuria, 55% of orthostatic proteinuria, 6% of constant proteinuria, 12% of proteinuria with hematuria, and 2% of transient proteinuria with isolated hematuria. Pathologic proteinuria were totaled as 20%. The prevalence of renal diseases among the age group of 7-18 years old was estimated to be 1.4 per 10,000. 4) Renal biopsy performed on 38 children with proteinuria at the third test revealed IgA nephropathy in 17(44%), focal segmental glomerusclerosis in 5(13%), minimal change disease in 4(11%), membranoproliferative glomeronephritis in 3(8%), $Henoch-Sch\"{o}nlein$ purpura nephritis in 3(8%), and others in 6(16%). Therefore, the prevalence of IgA nephropathy among the age group of 7-18 years old was estimated to be 0.64 per 10,000. 5) The prevalence of chronic renal failure was estimated to be 5.7 per 1 million of 7 to 18 years age group. Conclusions : 1) The prevalence of proteinuria in the first screening test was 0.28% and finally only 5% of them showed the pathologic proteinuria at the third test. 2) The prevalence of IgA nephropathy and chronic renal failure were 0.63 per 10,000 and 5.7 per 1 million, respectively among school-aged children in Seoul.

  • PDF

A Study on Developing Customized Bolus using 3D Printers (3D 프린터를 이용한 Customized Bolus 제작에 관한 연구)

  • Jung, Sang Min;Yang, Jin Ho;Lee, Seung Hyun;Kim, Jin Uk;Yeom, Du Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.61-71
    • /
    • 2015
  • Purpose : 3D Printers are used to create three-dimensional models based on blueprints. Based on this characteristic, it is feasible to develop a bolus that can minimize the air gap between skin and bolus in radiotherapy. This study aims to compare and analyze air gap and target dose at the branded 1 cm bolus with the developed customized bolus using 3D printers. Materials and Methods : RANDO phantom with a protruded tumor was used to procure images using CT simulator. CT DICOM file was transferred into the STL file, equivalent to 3D printers. Using this, customized bolus molding box (maintaining the 1 cm width) was created by processing 3D printers, and paraffin was melted to develop the customized bolus. The air gap of customized bolus and the branded 1 cm bolus was checked, and the differences in air gap was used to compare $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$ and $V_{95%}$ in treatment plan through Eclipse. Results : Customized bolus production period took about 3 days. The total volume of air gap was average $3.9cm^3$ at the customized bolus. And it was average $29.6cm^3$ at the branded 1 cm bolus. The customized bolus developed by the 3D printer was more useful in minimizing the air gap than the branded 1 cm bolus. In the 6 MV photon, at the customized bolus, $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of GTV were 102.8%, 88.1%, 99.1%, 95.0%, 94.4% and the $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of branded 1cm bolus were 101.4%, 92.0%, 98.2%, 95.2%, 95.7%, respectively. In the proton, at the customized bolus, $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of GTV were 104.1%, 84.0%, 101.2%, 95.1%, 99.8% and the $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of branded 1cm bolus were 104.8%, 87.9%, 101.5%, 94.9%, 99.9%, respectively. Thus, in treatment plan, there was no significant difference between the customized bolus and 1 cm bolus. However, the normal tissue nearby the GTV showed relatively lower radiation dose. Conclusion : The customized bolus developed by 3D printers was effective in minimizing the air gap, especially when it is used against the treatment area with irregular surface. However, the air gap between branded bolus and skin was not enough to cause a change in target dose. On the other hand, in the chest wall could confirm that dose decrease for small the air gap. Customized bolus production period took about 3 days and the development cost was quite expensive. Therefore, the commercialization of customized bolus developed by 3D printers requires low-cost 3D printer materials, adequate for the use of bolus.

  • PDF

A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION (임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구)

  • Kim Pyung-Il;Kim Yung-Soo;Jang Kyung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

The Mechanism of Interferon-$\gamma$ Induced Cytotoxicity on the Lung Cancer Cell Line, A549 (인터페론감마에 의한 A549 폐암세포주 세포독성의 기전)

  • Oh, Yeon-Mok;Yoo, Chul-Gyu;Chung, Hee-Soon;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.1
    • /
    • pp.63-68
    • /
    • 1996
  • Background: Interferon-$\gamma$ has various biologic effects, including antiviral effect, antitumor proliferative effect, activation of macrophage and B lymphocyte, and increased expression of major histocompatibility complex. Especially, antitumor proliferative effect of interferon-$\gamma$ has already been proved to be important in vivo as well as in vitro. And, clinical studies of interferon-$\gamma$ have been tried in lung cancer patients. However, the mechanism of antitumor effect of interferon-$\gamma$ has not yet been established despite of many hypotheses. "Necrosis" is a type of cell death which is well known to occur in the circumstances of severe stresses. In contrast, "apoptosis" is another type of cell death which occurs in such biological circumstances as embryonic development, regression of organs, and self-tolerance of lymphocytes. And, apoptosis is an active process of cell death in which cells are dying with fragmentations of their cytoplasms and nuclei. And, in the process of apoptosis the DNAs of cells are cleaved between nucleosomes by unidentified endonuclease and therefore DNAs of apoptotic cells result in a typical electrophoresis pattern known as DNA ladder pattern. Recently it has been suggested that cytotoxic effect of interferon-$\gamma$ occurs via apoptosis. To elucidate the mechanism of antitumor cytotoxic effect of interferon-$\gamma$, we microscopically observed a lung cancer cell line, A549 which was treated with interferon-$\gamma$. We observed A545 treated with interferon-$\gamma$ was dying fragmented. And so, we performed this study to find out that the mechanism of antitumor cytotoxic effect of interferon-$\gamma$ be apoptosis. Method: We treated A549, human lung cancer cell line with various concentration of interferon-$\gamma$ and quantified its cytotoxic effect of various periods, 24 hours, 72 hours and, 120 hours by MTT(dimethylthiazolyl diphenyltetrazolium bromide) bioassay. Also, after we treated A549 with 100 units/mi of interferon-$\gamma$ for 120 hours, we observed the pattern of cell death with inverted microscope and we extracted DNAs from the dead A549 cells and observed the pattern of 1.5% agarose gel electrophoresis with ethidium bromide staining. Result: 1) Cytotoxic effect of interferon-$\gamma$ on A549: For the first 24 hours, threre was little cytotoxic effect and for between 24 hours and 72 hours, there was the beginning of cytotoxic effect and for 120 hours there was increased cytotoxic effect. 2) Pattern of A549 cell death by interferon-$\gamma$: We observed with inverted microscope that A549 cells were dying fragmented. 3) DNA ladder pattern of gel electrophoresis: We observed DNA ladder pattern of gel electrophoresis of extracted DNAs from dead A549 cells. Conclusion: We concluded that the mechanism of interferon-$\gamma$induced cytotoxicity on lung cancer cell line, A549 be via apoptosis.

  • PDF

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

A Study on the Curriculum for Record Management Science Education - with focus on the Faculty of Cultural Information Resources, Surugadai University; Evolving Program, New Connections (기록관리학의 발전을 위한 교육과정연구 -준하태(駿河台)(스루가다이)대학(大學)의 경우를 중심(中心)으로-)

  • Kim, Yong-Won
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.1 no.1
    • /
    • pp.69-94
    • /
    • 2001
  • The purpose of this paper is to provide an overview of the current status of the records management science education in Japan, and to examine the implications of the rapid growth of this filed while noting some of its significant issues and problems. The goal of records management science education is to improve the quality of information services and to assure an adequate supply of information professionals. Because records management science programs prepare students for a professional career, their curricula must encompass elements of both education and practical training. This is often expressed as a contrast between theory and practice. The confluence of the social, economic and technological realities of the environment where the learning takes place affects both. This paper reviews the historical background and current trends of records management science education in Japan. It also analyzes the various types of curriculum and the teaching staff of these institutions, with focus on the status of the undergraduate program at Surugadai University, the first comprehensive, university level program in Japan. The Faculty of Cultural Information Resources, Surugadai University, a new school toward an integrated information disciplines, was opened in 1994, to explore the theory and practice of the management diverse cultural information resources. Its purpose was to stimulate and promote research in additional fields of information science by offering professional training in archival science, records management, and museum curatorship, as well as librarianship. In 1999, the school introduced a master program, the first in Japan. The Faculty has two departments and each of them has two courses; Department of Sensory Information Resources Management; -Sound and Audiovisual Information Management, -Landscape and Tourism Information Management, Department of Knowledge Information Resources Management; -Library and Information Management, -Records and Archives Management The structure of the entire curriculum is also organized in stages from the time of entrance through basic instruction and onwards. Orientation subjects which a student takes immediately upon entering university is an introduction to specialized education, in which he learns the basic methods of university education and study, During his first and second years, he arranges Basic and Core courses as essential steps towards specialization at university. For this purpose, the courses offer a wide variety of study topics. The number of courses offered, including these, amounts to approximately 150. While from his third year onwards, he begins specific courses that apply to his major field, and in a gradual accumulation of seminar classes and practical training, puts his knowledge grained to practical use. Courses pertaining to these departments are offered to students beginning their second year. However, there is no impenetrable wall between the two departments, and there are only minor differences with regard requirements for graduation. Students may select third or fourth year seminars regardless of the department to which they belong. To be awarded a B.A. in Cultural Information Resources, the student is required to earn 34 credits in Basic Courses(such as, Social History of Cultural Information, Cultural Anthropology, History of Science, Behavioral Sciences, Communication, etc.), 16 credits in Foreign Languages(including 10 in English), 14 credits on Information Processing(including both theory and practice), and 60 credits in the courses for his or her major. Finally, several of the issues and problems currently facing records management science education in Japan are briefly summarized below; -Integration and Incorporation of related areas and similar programs, -Curriculum Improvement, -Insufficient of Textbooks, -Lack of qualified Teachers, -Problems of the employment of Graduates. As we moved toward more sophisticated, integrated, multimedia information services, information professionals will need to work more closely with colleagues in other specialties. It will become essential to the survival of the information professions for librarians to work with archivists, record managers and museum curators. Managing the changes in our increasingly information-intensive society demands strong coalitions among everyone in cultural Institutions. To provide our future colleagues with these competencies will require building and strengthening partnerships within and across the information professions and across national borders.

20 Years Surgical Experiences for Ebstein's Anomaly (엡스타인 기형의 20년 수술 치험)

  • Lee, Sak;Park, Han-Ki;Lee, Chang-Young;Chang, Byung-Chul;Park, Young-Hwan
    • Journal of Chest Surgery
    • /
    • v.40 no.4 s.273
    • /
    • pp.280-287
    • /
    • 2007
  • Background: We retrospectively evaluated the clinical results of surgically managing patients with Ebstein's anomaly. Material and Method: Between Feb. f 984 and June 2006, 50 patients who underwent surgical treatment for Ebstein's anomaly at Yonsei Cardiovascular Center were retrospectively reviewed. The mean age of the patients was 26.9 years and 19 patients were male, Associated anomalies included atrial septal defect (33), patent ductus arteriosus (2), ventricular septal defect (1), and pulmonary stenosis (4), and 90%, (45/50) of the patients had more than a moderate degree of tricuspid regurgitation. Carpentier type A was present in 6 patients, type B in 26, type C in 14 and type D in 4. Ten patients were associated with WPW syndrome. Conservative surgery was possible in 31 patients (tricuspid annuloplasty, plication of the atrialized RV), Fontan's operation was peformed in 4 patients, tricuspid valve replacement was done in 12 and palliative surgery was done in 2 patients. Thirteen patients were associated with hi-directional cavopulmonary shunt (BCPS: one and a half ventricular repairs): 10 patients with WPW syndrome and 4 patients with atrial fibrillation underwent concomitant ablation. Result: The postoperative median NYHA functional class $(3{\rightarrow}1)$ and the mean cardio-thoracic ratio $(0.65{\rightarrow}0.59)$ were decreased significantly (p<0.001, p=0.014). The mean oxygen saturation $(86.6{\rightarrow}94.1%)$, and median TR grade $(4{\rightarrow}1)$ were also significantly improved (p=0.004, p<0.001). For comparison of BCPS and conservative surgery, the preoperative right ventricular pressure (33.0 vs. 41.3 mmHg), the ICU stay (2.80 vs. 1.89 days), the hospital say (10.6 vs. 16.8 days), and the left ventricular ejection fraction (64.3 vs. 72.8%) were statistically different. Postoperative mortality occurred in 3 patients (6%) due to biventricular failure in 2 patients and sepsis in the other patient. The mean follow up duration was 101.5 months, and one patient died of Fontan failure and 6 patients required reoperation (bioprosthetic degenerative change (2) and Fontan conversion (4)). The overall survival rate at 10 years was 90.2%, the freedom from reoperation rate and rate of cardiac related events were 78.9% and 49.2%, respectively. Conclusion: Surgical management of Ebstein's anomaly can be performed safely, and the associated BCPS may be helpful for high-risk patients. Adequate application of surgical management may increase the long-term survival with a reduced rate of reoperation.

Efficacy of Self-manipulation Technique in the Treatment of Patients with Anterior Disc Displacement without Reduction (비정복성 관절원판 전방변위 환자의 치료에 있어서 자가 수조작술의 효과에 대한 연구)

  • Kim, Ju-Sik;Lee, Chae-Hoon;Kim, Young-Ku
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.4
    • /
    • pp.441-447
    • /
    • 2007
  • Internal derangement of the temporomandibular joint(TMJ) is defined as an abnormal relationship of the articular disc to the condyle. Mandibular manipulation is one of the conservative treatments to be considered first to manage the patients with anterior disc displacement without reduction. Mandibular manipulation is used to increase articular mobility and to restore the displaced disc into an anatomically normal position. While Farrar's technique has been popularly used, Minagi et al., Mongini and Suarez introduced the manipulation technique conducted by the patients themselves. But there is no study on the efficacy of self-manipulation technique, comparing with conventional one. The aim of this study was to investigate the efficacy of the conventional and self-manipulation technique, which was modified to complement the previously described technique by Minagi et al., in the treatment of patients with anterior disc displacement without reduction. TMD patients, who visited Department of Oral Medicine of Seoul National University Dental Hospital from December, 2002 to November, 2004 and were diagnosed as anterior disc displacement without reduction by TMJ magnetic resonance imaging (MRI) were enrolled. Conservative treatments including physical therapy, exercise, behavioral therapy, stabilization splint therapy, and manipulation therapy were done to every single patient until the symptomsimproved enough to discharge the patient. The charts were reviewed retrospectively according to the type of manipulation. In the results, patients whose maximum mouth opening was more than 40 mm was higher in the self-manipulation group(69.9%) than in the conventional manipulation group(42.9%). But difference between two groups was not significant. According to the fact that we decided to discharge the patients whentheir mouth opening increased to more than 40 mm and subjective symptoms such as pain and discomfort were improved as well, treatment period of discharged patients was significantly shorter in the self-manipulation group($29.2{\pm}12.3$ weeks) than in the conventional manipulation group ($61.0{\pm}38.0$ weeks) (p<0.01). In conclusion, in the treatment of TMD patients with anterior disc displacement without reduction, the self-manipulation technique which is performed by patients themselves is an effective treatment modality for increasing the range of mouth opening and shortening the total treatment period.

Henoch-$Sch{\ddot{o}}nlein$ Nephritis in Children (소아 Henoch-$Sch{\ddot{o}}nlein$ 신염의 추적 관찰)

  • Jang, Hee-Suk;Hong, In-Hee;Go, Cheol-Woo;Koo, Ja-Hun;Kwak, Jung-Sik
    • Childhood Kidney Diseases
    • /
    • v.4 no.2
    • /
    • pp.120-126
    • /
    • 2000
  • Purpose : This retrospective study has been undertaken to find out the clinical outcome of children with HS nephntis and its relationship with initial clinical presentation and/or renal pathologic finding. Patients and methods : Study population consisted of 59 children with HS nephritis who have been admitted to the Pediatric department of Kyungpook University Hospital from 1987 to 1999, and biopsy was done with indications of heavy proteinuria (> 1 g/m2/day) lasting over 1 month, nephrotic syndrome, and persistent hematuria and/or proteinuria over 1 year. Patients were divided clinically into 3 groups ; isolated hematuria, hematuria with proteinuria and heavy proteinuria (including nephrotic syndrome). Biopsy findings ore graded from I-V according to International Study of Kidney Disease in Children (ISKDC). Results : Mean age of presentation was $8.1{\pm}3.0$ years and slight male preponderance m noted (33 boys md 26 girls). Histopathologic grading showed Grade I ; 2, Grade II ; 44, and Grade III ; 13 cases. Clinical outcome at the follow-up period of 1-2 year (49 cases) and 3-4 years (30 cases) shooed normal urinalysis in 75 (30.6$\%$) and 18 cases (60.0$\%$), persistent isolated hematuria in 20 (40.8$\%$) and 2 cases (6.7$\%$), hematuria with proteinuria in 11 (22.5$\%$) and 8 cases (26.6$\%$), and persistent heavy proteinuria in 3 (6.1$\%$) and 2 cases (6.7$\%$) respectively. Clinical outcome according to histopathologic grading showed the frequency of normalization of urinalysis being lower in Grade III compared to grade I or II. Clinical outcome according to initial clinical presentation showed no relationship to the normalization or urinalysis at follow-up periods. However, 15-20$\%$ of children with initial heavy proteinuria showed persistent heavy proteinuria (3 out of 20 cases at 1-2 years, and 2 out of 10 case at 3-4 years of follow-up periods). Conclusion : The majority of children with HS nephritis (histopathologic grade I, II, III) improved within 3-4 years and persistent heavy proteinuria was seen only in a kw of children with initial clinical presentation of heavy proteinuria.

  • PDF