1 |
Hwang HW, Lee SC, Kim YG, Ryu DM, Lee BS, Clinical study of dental implant: requirements for successful osseointegration. KAID 1999:18:1-9
|
2 |
Eriksson A. Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury : A vital microscopic study in rabbit. J Prosthet Dent 1983:50:101-107
|
3 |
Kerawala CJ, Martin IC, Allan W, Williams ED. The effects of operature technique and bur design on temperature during osseous preparation for osteosynthesis self-tapping screws. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1999:88:145-150
|
4 |
Wachter R, Stroll P. Increase ot temperature during osteotomy. In vitro and in vivo investgations. Int J Oral Maxillofac Surg 1991:20:245-249
|
5 |
Iyer S, Weiss C, Mehta A. Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part 1 : Relatationship between drill speed and heat production. Int J Prosthodont 1997:10:411-414
|
6 |
Moon ES, Lim HS, Cho IH. A study on the heat generation of bone drilling burs according to irrigation during implantation of dental implant. J Kor Academy of Pros 1999:37:433-453
|
7 |
Sutter F, Krekeler G, Schwammerger AW, Sutter FJ. Atraumatic surgical technique and implant bed preperation. Quintessence Int 1992:23:811-816
|
8 |
Moritz AR, Henriques FC Jr. Studies of thermal injury. Am J Path 1947;23:695-720
|
9 |
Brisman DL. The effect of speed, pressure, and time on bone temperature during the drilling of implant sites. Int J Oral Maxillofac Implants 1996:11:35-37
|
10 |
Sevitt S. Pathological sequelae of burns. Proc R Soc Med 1954:47:225-228
|
11 |
Albrektsson T. Branemark PI. Hansson HA, Lindstro J. Osseointegrated titanium implants. : Requirements for ensuring a long lasting, direct bone ankorage in man. Acta Orthop Scand 1981:52:155-170
|
12 |
Yacker M, Klein M.: The effect of irrigation on osteotomy depth and bur diameter. Int J Oral Maxillofac Implants., 1996:11: 634-638
|
13 |
Watanabe F, Tawade Y, Komatus S, Hata Y. Heat distribution in bone during preparation of implant sites: heat annalysis by real-time thermography. Int J Oral Maxillofac Implants. 1992:7:212-219
|
14 |
Eriksson R, Adell. Temperature during drilling for the placement of implants using the osseointegration technique. J Oral Maxllofac Surg 1986:44:4-7
|
15 |
Cordioli G, Majzoub Z. Heat generation during implant site preparation. An in vitro study. Int J Oral Maxillofac Implants 1997:12:186-193
|
16 |
Abouzgia MB, James DF. Temperature rise during drilling through bone. Int J Oral Maxillofac Implants 1997:12:342-353
|
17 |
Krause WR, Bredbury DW, Kelly JE, Lunceford EM. Temperature elevation in orthopedic cutting operations. J Biomech Eng 1982: 15: 267-275
|
18 |
Albrektsson T, Zarb G, Worthington P, Eriksson A. The long-term efficacy of currently used dental implants. A review and proposed criteria for success. Int J Oral Maxillofac Implants 1986: 1: 11-25
|
19 |
Lee JG, Yang JH. Lee SH. A study on the effect of rotational speeds of the trephine mill on the temperature of surrounding bone during dental implantation procedure and osseointegration of implants. J Kor Academy of Pros 1992:30:167-190
|
20 |
Mathews LS. Hirsch C. Temperatures measured in human cortical bone when drilling. J Bone Joint Surg 1972:54:297-308
|
21 |
Bachus KN, Rondina MT, Hutchinson DT. The effects of drilling force on cortical temperatures and their duration: an vitro study. Medical Engineering & Physics 2000:22: 685-691
|
22 |
Benington IC, Biagioni PA. Crossey PJ. Hussey DL, Sheridan S, Lamey PJ. Temperature changes in bovin mandibular bone during implant site preparation: an assessment using infra-red thermography. J Dent 1996:24:263-267
|