An Experimental Study on the Properties of Porous Concrete according to Correction Factor and Specimen Thickness (보정계수 및 시험체두께가 포러스콘크리트의 기초물성에 미치는 영향에 관한 실험적 연구)

  • 김재환;이성일;장종호;오시덕;박정호;김무한
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.55-58
    • /
    • 2002
  • This study is to analyze the influence of correction factor and specimen thickness on the fundamental properties of porous concrete. Results of this study were shown as follows; 1) As correction factor decrease, compaction time according to correction factor and specimen thickness decrease. Also, though correction factor is same, as specimen thickness increase, compaction time increase. So It mutt be considered that the influence of compaction time according to correction factor and specimen thickness. 2) As correction factor decrease, difference of measured thickness and designed thickness according to correction factor and specimen thickness decrease. Also, correction factor of aggregate of 10~l5mm is smaller than that of 5~l0mm. So It must be considered that the influence of correction factor according to size of aggregate.

  • PDF

A Study on the Work-Planning Method of High-rise Building (초고층 건물의 구조체 공사의 작업계획방법에 관한연구)

  • Kim Dae-Gil;Hwang Jae-Hoo;Jung Ho-Geun;Kim Ju-Hwan;Lee Sang-Beom
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.129-132
    • /
    • 2006
  • Recently, Society increasingly need the hish-rise building because of urban population concentration. and The hish-rise building need new systematic work-planning method. but it didn't use the construction project's work plan and management. his paper investigated efficient work-planning method. and the work-planning method in using domestic High-rise building's structure work. A investigated result is TACT, DOC LOB etc. and domestic using method is 3day and 4day-Cycle among the Tact. This paper is to compare and analysis two method. a purpose of paper is to analyse application through the case of using the work-planning method. also To find efficient method.

  • PDF

A study on the Application Scheme of the Warranty contract in constructions (건설공사의 성능계약 도입방안에 관한 연구)

  • Kim, Dae-Gil;Jeong, Ho-Geun;Seo, Young-Chil;Lee, Sang-Beom
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.89-92
    • /
    • 2007
  • Since 1960s, advanced constructions have introduced warranty contract which is warranted to quality and performance for need of owner in determined term to ensure the quality of construction. However, the interior of a country encounter another problem result from Defects Liability what indefiniteness of defects standard, excess responsibility period, social recognition of be identical fraudulent work and defects, and contract with ascendancy of owners. etc, so builders concerned more excess defects liability than the quality of construction. The purpose of this study is to analysis of warranty contract in order to solve the problem such as stated above.

  • PDF

창녕군 증산리 지역 강변여과수 타당성 조사 및 시험 정호 설치

  • Kim Hyeong-Su;Won Lee-Jeong;Seok Hui-Jun;Park Cheol-Suk
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.76-81
    • /
    • 2006
  • 창녕군 증산리 지역은 신규 취수원 확보 일환으로 강변여과 방식 취수 가능성이 한국수자원공사에 의해서 평가되고 있는 지역이다. 강변여과 방식 취수의 타당성 평가를 위해 현장 지질조사, 시추조사, 전기 비저항 탐사 및 고해상도 탄성파 탐사를 수행하였다. 또한 대상 연구지역에서의 개략적 취수 가능량 산정을 위해 모델링 평가가 수행되었으며, 개별 정호에 대한 양수량 산정을 위해 시험 정호를 설치하였다. 현장 시추 조사와 시료에 대한 입도 분석 결과, 연구 지역의 충적층 두께는 35m 전후이며, 주 대수층 구간은 지표하 $25{\sim}35m$인 것으로 추정되었다. 또한 주 대수층 구간의 수리전도도는 $10^{-2}cm/sec$ 이상으로 주로 모래섞인 자갈층으로 구성되어있는 것으로 평가되었다. 또한 전기비저항 조사 결과는 부분적으로 매우 낮은 비저항 분포 지층을 보여주고 있으며, 이는 주로 실트 및 점토로 된 지층이 부분적으로 퇴적되어 있음을 지시하며, 고해상도 탄성파 탐사 결과는 전반적으로 지하수위는 지표하부 5m 전후에 분포하고, 충적층의 하부 경계는 35 내지 45m인 것으로 해석되었다. 지하수 모델링을 통해, 취수 목표량인 180,000톤/일은 주대수층까지의 지하수위 강하 없이 확보 가능할 것으로 평가되었다. 또한 개별 정호의 산출 특성을 평가하기 위해 시험 정호를 설치하여, 실제 2,700톤/일 예비 양수 시험을 수행하였다. 예비 양수 시험 결과, 양수정에서의 수위 강하는 개략 10m, 양수정관측정에서는 약 0.3m의 수위강하만이 관찰되었으며, 양수 영향권이 수 십 m를 넘지 않을 것으로 판단되었다.서의 S97과 JBR의 세포감염 억제율은 3.85%와 3.63%로 나타났다. $textsc{k}$-casein, CU는 로타바이러스 S97과 JBR에 대해 농도 2000UM에서 97%이상의 억제효과를 나타냈으며, sialic acid는 억제효과가 거의 없었다. K-casein, GMP는 송아지뿐만 아니라 유아의 로타바이러스에 의한 설사를 억제할 수 있을 것으로 기대된다.을 향상하기 위해서는 이러한 부위에 대한 미생물 오염을 낮출 수 있는 세심한 현장 품질관리가 필요하다.en and adolescents, analysed by country, age group and gender. The paper discusses the places young consumers can turn to in trying to fulfil their growing consumer needs. It also examines how much money is at their disposal. It then concludes by considering the influence of "financial socialization" on how young people deal with money.nsumption visions based on the various perspectives, consumers are influenced in the apparel buying decision-making. Many subjects reported experiencing positive affect when imagining positive outcomes of produc

  • PDF

A Study on Risk Influence Factors of Ground Subsidence through Soil Investigation Analysis (지반조사 분석을 통한 지반함몰 위험영향인자 연구)

  • Joung, Ho Young;Lee, Gil Hwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.1
    • /
    • pp.43-46
    • /
    • 2017
  • Recently, the development of underground space is being actively carried out in the urban area by saturation, and the excavation works are mainly carried out by various excavation methods by the structures adjacent to the ground and underground excavation. During such excavation work, ground subsidence accidents are occurring due to inattention construction, lack of construction technology, and leakage of ground water. For the prevention of ground subsidence we studied the method of risk influence factors by soil investigation. Analysis of 75 sites soil investigation by U.S.C.S (Unified Soil Classification System), construction method, depth of excavation and we studied the risk influence factors with ground subsidence.

An experimental Study on the Structural Performance Evaluation of One-way Hollow Core Slab (일방향 중공 슬래브의 구조성능 평가에 대한 실험적 연구)

  • Kim, Dong Baek;Song, Dae Gyeom;Choi, Jung Ho;Cho, Hyun Sang
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.3
    • /
    • pp.343-351
    • /
    • 2018
  • Purpose: Recently, As the size of the structure increased, the necessity of reducing its weight was raised. To reduce weight In concrete structures, a hollow slab is proposed as an alternative for weight reduction effect. Method: It is difficult to construct the hollow body due to buoyancy, and the shear performance is insufficient due to the decreased cross section. Slabs were fabricated using unidirectional hollow bodies such as PVC pipes, and experiments were conducted about construction performance and structural performance. Results: The buoyancy preventive device has been improved the construction performance by preventing floating hollow body, it has been confirmed that it has adequate performance to be used as a hollow slab system because it has enough expected shear performance. Coclusion: Hollow ratio has a little connection with bending performance, but after the yielding load, it is necessary to consider the secondary stiffness of structure, and is is supposed that the decrease of shear performance with the increase of hollow core ratio can be complemented with shear reinforcement.

New Patent Technology for Retaining Wall and Bridge Abutment (옹벽 및 교대 신기술 특허)

  • Kim, Kyeong-Ho;Choi, Jung-Ho;An, Jung-Seng;Kim, Nak-Gyeom
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.895-898
    • /
    • 2008
  • This research paper intends to investigate and review the new technology of patent registration trend for the most recent domestic retaining wall and bridge abutment, and to apply the technology appropriately to the actual retaining wall and bridge abutment construction. Investigated new technological patents for retaining wall include pre-fabricated PC retaining wall construction method that reduces section force with prestressed PS steel bars, pre-fabricated Coupler-Tension retaining wall, clay reinforced retaining wall block for road, earth reinforced retaining wall block that induces uniform settlement, and etc. Investigated new technologies for abutment are abutment construction method that uses sheet pile, monolithic bridge with complex abutments, construction method for abutment bridge, earth reinforced abutment structure and etc.

  • PDF

Analyzing the Significance of Enhancements in Zero Energy Building Rating Systems: A Comparative Study between Designers and Building Energy Assessors (설계자와 건축물 에너지 평가사 측면의 제로에너지 건축물 인증 활성화를 위한 중요도 비교 분석)

  • Myung, Il;Choi, Jong-Dae;Jung, Ho-Youn;Choi, Jae-Kyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.4
    • /
    • pp.453-464
    • /
    • 2023
  • This research conducts a comparative analysis of the perceived importance of advancing zero energy building certification from the viewpoints of two major stakeholders - designers and building energy assessors. Both groups prioritized the importance of policy, technology, education, incentives, and promotion respectively. For designers, enhancing energy efficiency standards, developing a skilled energy workforce, and implementing an office registration system emerged as critical factors in invigorating the certification process. The findings suggest potential avenues for the government to formulate realistic strategies for boosting the certification activity.

Detecting Steel Pile Using Bore-hole 3-components Fluxgate Magnetometer (강관말뚝 탐지를 위한 시추공 3성분 자기탐사)

  • Lee, Heui-Soon;Rim, Hyoung-Rea;Jung, Ho-Joon;Jung, Hyen-Key;Yang, Jun-Mo
    • Journal of the Korean earth science society
    • /
    • v.31 no.7
    • /
    • pp.673-680
    • /
    • 2010
  • A steel pile often utilized to bear heavy loads of the upper sub-structure, e. g., bridge constructions and tall buildings. As the steel piles are driven in the underground, it is not easy to detect the depth of the existing pile foundation when there is no detailed foundation information available. However, accurate informations of the depths of piles becomes critical required when reinforcing the existing structures or constructing new ones at the adjacent stage to assure the safety of existing structures. In this study, we tested the applicability of the three components borehole fluxgate magnetometer for detecting the depths and locations of steel piles which are commonly used in civil engineering. Results showed that the information of location as well as the depth of steel piles could be obtained by using data from the three components borehole fluxgate magnetometer.

A Study on Clogging during Installation of Compaction Pile (다짐말뚝 시공 시 공극 막힘 현상 분석 연구)

  • Choi, Jeong Ho;Park, Seong Jin;Choo, Yun Wook;Kim, Il Gon;Kim, Byeong Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.4
    • /
    • pp.33-45
    • /
    • 2022
  • A series of model tests were performed in this study to demonstrate the clogging mechanism created during the installation of a compaction pile to improve soft ground. The application of an air-jet to extrude sand or aggregates from a casing during the installation of a compaction pile imposes a remarkably high-pressure difference between the composite soil layers of clay and sand (or aggregates), resulting in severe clogging. Therefore, a one-dimensional testing system was developed to simulate composite soil layers consisting of clay and sand (or aggregates) and to apply a high-pressure differential at both boundaries, thus replicating the extrusion process used in compaction pile installation. Herein, the performance of two construction materials for compaction piles of crushed stone and grading-controlled aggregates was compared. A series of one-dimensional model tests were performed under multiple pressure settings, with clogging depth and permeability measured in each case. Results indicate that, blinding clogging mechanisms and blocking defined by previous studies were observed for crushed stone, and a new mechanism of "infiltration" was revealed and defined. Whereas, the controlled aggregates performed excellently against clogging because only blinding was observed.