• Title/Summary/Keyword: 정적 교정

Search Result 41, Processing Time 0.038 seconds

National Vacuum Standards from Low to Ultra-high Vacuum (저진공에서 초고진공까지의 국가 진공표준)

  • Hong S. S.;Lim I. T.;Shin Y. H.;Chung K. H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.1-13
    • /
    • 2006
  • Vacuum laboratory in Korea Research Institute of Standards and Science (KRISS) was opened in 1983 for establishing and disseminating vacuum standard in Korea. The major three systems such as the ultrasonic interferometer manometer (UIM), the static expansion system (SES) and the dynamic expansion system (DES) with orifice and porous plug conductance are developed. In this study, the standard systems from low to ultra-high vacuum, uncertainty analysis by ISO regulation, and key and bilateral comparison results will be described.

Frictional resistance of different ceramic brackets and their relationship to the second order angulation between bracket slot and wire (세라믹 브라켓의 종류 및 브라켓 슬롯과 와이어 각도에 따른 마찰 저항 차이)

  • Choi, Yoon-Jeong;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.36 no.3 s.116
    • /
    • pp.207-217
    • /
    • 2006
  • Although ceramic brackets have been used widely for improved esthetics during treatment, ceramic brackets have some inherent problems; brittleness, attrition of the opposing teeth and high frictional resistance. This study was performed to understand the frictional resistance of the ceramic brackets, as well as to be a helpful reference for finding the solutions to the problem of frictional resistance. Three different kinds of brackets were used; metal bracket, polycrystalline ceramic brackets with a metal slot to reduce the high frictional resistance and monocrystalline ceramic brackets. The brackets were tested with a $.019{\times}.025$ stainless steel wire with a second order angulation of $0^{\circ}\;and\;10^{\circ}$, and the static and kinetic frictional forces were measured on the universal testing machine. The results of this study showed that the ceramic brackets, especially the monocrystalline ceramic bracket without a metal slot, generated higher frictional resistance than the metal bracket, and the frictional resistance was increased as the angulation between the bracket slot and the wire increased. Therefore, the development of the ceramic bracket with reduced frictional resistance and the prevention of excessive crown tipping during orthodontic treatment will lead to the simultaneous attainment of more efficient and improved esthetic treatment goals.

Development of a national medium vacuum standard by static expansion method (정적법을 이용한 중진공 국가표준기 개발)

  • Hong S. S.;Lim I. T.;Shin Y. H.;Chung K. H.
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.2
    • /
    • pp.59-68
    • /
    • 2005
  • We developed a national medium vacuum standard by static expansion method. A 133 Pa capacitance diaphragm gauge was calibrated and analysed according to the document of 'Guide to the Expression of Uncertainty in Measurement' of ISO. The results showed that the expanded uncertainty of $2.628\times10^{-3}$ Pa at $95\%$ confidence level and coverage factor of k=2.

Inter-comparison between ultrasonic interferometer manometer and medium vacuum standards by static expansion method (초음파간섭 수은주압력계와 정적법 중진공 국가표준기 상호비교)

  • Hong S. S.;Lim I. T.;Shin Y. H.;Chung K. H.
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.3
    • /
    • pp.103-109
    • /
    • 2005
  • A new medium vacuum primary standard using the static expansion method was developed in KRISS. In order to evaluate the performance of the equipment, we compared the medium vacuum standard with an ultrasonic interferometer manometer using two capacitance diaphragm gauges, the measuring ranges of which were 133 Pa and 1,333 Pa respectively. The result, Error normalized values, showed that the two standards are coincident each other within the range of combined uncertainty at calibrated pressure of $3pa\;\sim\;100pa$.

Development of Static Rock Penetrometer for Locating Rock Stratum During Construction of Drilled Shafts (암반에 근입된 현장타설말뚝 시공시 선단부 강도확인을 위한 정적암반관입기 개발연구)

  • Nam, Moon-S.
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.9
    • /
    • pp.71-74
    • /
    • 2010
  • During construction of deep foundation in soft rock under varying soil properties, it is essential to locate the rock stratum, especially when drilling with slurry. When slurry is used for drilling, the bottom of the borehole cannot be seen, thereafter soil cuttings cannot be differentiated from soft rock cuttings. A new static rock penetrometer, known as Rock Penetrometer was developed during this study. It could be a simple mechanical device that is attached to the bottom of a Kelly bar which is used to attach drilling tools such as augers and core barrels while drilling. After its calibration in the laboratory, the performance of the static rock penetrometer was verified in the several field test sites.

Effects of Thermal and Mechanical Fatigue Stress on Bond Strength in Bracket Base Configurations (열적, 기계적 피로응력이 교정용 브라켓의 결합강도에 미치는 영향)

  • Kim, Jong-Ghee;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.625-642
    • /
    • 2000
  • The purpose of this study is to evaluate the effects of mechanical and thermal fatigue stress on the shear, tensile and shear-tensile combined bond strengths(SBS, TBS, CBS) in various orthodontic brackets bonded to human premolars with chemically cured adhesive(Ortho-one, Bisco, USA). Five types of commercially available metal brackets with various bracket base configurations of Photoetched base(Tomy, Japan), Non-Etched Foil Mesh base(Dentaurum, Germany), Micro-Etched Foil Mesh base(Ortho Organizers, USA), Chessboard base(Daesung, Korea), and Integral base(3M Unitek, USA) were used. Samples were divided into 3 groups, the first group was acted with shear-tensile combined loads($45^{\circ}$) of 200g for 4 weeks(mechanical fatigue stress), the second group was subjected to the 5,000 thermocycles of 15 second dwell time each in $5^{\circ}C\;and\;55^{\circ}C$ baths(thermal fatigue stress), and the third group was the control. Bond strengths were measured at the crosshead speed of 0.5mm/min. The cross-section of bracket base/adhesive interface and the fracture surface were examined with the stereoscope and the scanning electron microscope. The resin remnant on bracket base surface was assessed by ART(Adhesive Remnant Index). The obtained results were summarized as follows, 1. In static bond strength, Photoetched base bracket showed the maximum bond strength and Integral base bracket showed the minimum bond strength(p<0.05). In all brackets, shear bond strength(SBS) was in the greatest value and shear-tensile combined strength(CBS) was in the least value(p<0.05). 2. After mechanical fatigue test, Photoetched base bracket showed the maximum bond strength and Integral base bracket showed the minimum bond strength(p<0.05). In Photoetched base bracket and Micro-Etched Foil Mesh base bracket, shear bond strength(SBS), tensile bond strength(TBS) and shear-tensile combined strength(CBS) were decreased after mechanical fatigue test(p

  • PDF

A Study on Usefulness of Static Retinoscopy in Eyes Opened for Hyperopic School-aged Children (양안개방상태에서 학령기 원시안 아동의 정적 검영법의 유용성 고찰)

  • Chun, Young-Yun;Park, Seong-Jong;Song, Woo-Jin;Lee, Seok-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.293-298
    • /
    • 2012
  • Purpose: We compared static retinoscopy in eyes opened with cycloplegic refraction depending on the hyperopia for school-aged children. Methods: There were 59 eyes (30 patients) who were divided into 3 groups - the mild hyperopia (+0.25 D ~ +1.00 D), moderate hyperopia (+1.25 D ~ +2.00 D) and high hyperopia (+2.25 D or more). They all had 0.8 visual acuity or more. Autorefraction and retinoscopy were performed prior to cycloplegic refraction, and then copmared with manifest refraction and cycloplegic refraction. Results: Hyperopia measured with static retinoscopy tends to be measured higher than manifest refraction for school-aged children. Changes of spherical power was statistically significant (p < 0.001). Changes of astigmatism was not statistically significant (p > 0.05). Conclusions: The difference between cycloplegic refraction and static retinoscopy was not significant for hyperopic school-aged children. The use of retinoscopy was limited for opticians because of legal constraints. The usage of static retinoscopy in eyes opened for optician should be generalized under the conditions not using the cycloplegic.

Flap Hinge Moment Estimation through Ground and Flight Tests (지상 및 비행 시험을 통한 플랩의 힌지 모멘트 추정)

  • Ko, Myung-Gyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.6
    • /
    • pp.464-470
    • /
    • 2018
  • In this paper, a practical method of estimating the flap hinge moments which change according to the aircraft flap operations was introduced. For the flap design, the hinge moment derived by structural load analysis and wind tunnel tests was able to be compared with the real flight hinge moment, and the static safety of the flap structure could be verified though this comparison. In order to perform the tests, two strain gauges were installed on the flap hinge and an onboard device for aircraft load monitoring was utilized. Through the ground test, the correlation between the strain and the moment of the flap hinge was calibrated with analytic and finite element analysis. During the flight test, strain signals together with the flap deflection angles and airspeed were recorded. Finally, the flight hinge moments could be predicted by the measured strain which was calibrated with the analytic and the finite element analysis.

Evaluation of friction of ceramic brackets in various bracket-wire combinations (브라켓 각도 변화에 따른 세라믹 브라켓의 마찰력 측정)

  • Cha, Jung-Yul;Kim, Kyung-Suk;Kim, Dong-Choon;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.36 no.2 s.115
    • /
    • pp.125-135
    • /
    • 2006
  • The purpose of this study was to measure and compare the level of frictional resistance generated from three currently used ceramic brackets; 1, Crystaline $V^{(R)}$, Tomy International Inc., Tokyo, Japan; 2, $Clarity^{(R)}$, 3M Unitek, Monrovia, CA, USA; 3, $Inspire^{(R)}$, Ormco, Orange, CA, USA; with composite resin brackets, Spirit, Ormco, Orange, CA, USA; and conventional stainless steel brackets, Kosaka, Tomy International Inc., Tokyo, Japan used as controls. In this experiment, the resistance to sliding was studied as a function of four angulations $(0^{\circ},\;5^{\circ},\;10^{\circ}\;and\;15^{\circ})$ using 2 different orthodontic wire alloys: stainless steel (stainless steel, SDS Ormco, Orange, CA, USA), and beta-titanium (TMA, SDS Ormco, Orange, CA, USA). After mounting the 22 mil brackets to the fixture and $.019{\times}.025$ wires ligated with elastic ligatures, the arch wires were slid through the brackets at 5mm/min in the dry state at $34^{\circ}C$. Silica-insert ceramic brackets generated a significantly lower frictional force than did other ceramic brackets, similar to that of stainless steel brackets. Beta-titanium archwires had higher frictional resistance than did stainless steel, and all the brackets showed higher static and kinetic frictional force as the angulation increased. When the angulation exceeded $5^{\circ}$, the active configuration emerged and frictional force quickly increased by 2.5 to 4.5-fold. The order of frictional force of the different wire-bracket couples transposed as the angle increased. The silica-insert ceramic bracket is a valuable alternative to conventional stainless steel brackets for patients with esthetic demands.