• Title/Summary/Keyword: 정밀진단

Search Result 693, Processing Time 0.042 seconds

A study on performance-based evaluation system for NATM tunnels in use: development of evaluation model and validation (공용중인 NATM 터널의 성능중심 평가체계 연구: 평가모형 개발 및 검증)

  • Moon, Joon-Shik;Kim, Hong-Kyoon;An, Jai-Wook;Lee, Jong-Gun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.1
    • /
    • pp.107-120
    • /
    • 2020
  • In a performance-based evaluation of structures in use, the current performance is assessed by summing up the weighting of the evaluation indices for each performance. In this study, to suggest a performance-based evaluation technique for NATM tunnels in use, the performance evaluation indices were derived by examining the characteristics and similarities of each index developed from previous study. The weighting of the evaluation indices was derived by calculating the relative importance of each evaluation indices from the AHP analysis. In order to develop a quantitative evaluation model, grading criteria for each performance index was derived through literature review, and performance evaluation tables for road and railway tunnels were presented. In order to verify the significance of the proposed performance evaluation model, the correlation analysis was performed between each evaluation index and the final evaluation result. In the correlation analysis, the survey data measured through precision safety diagnosis in the tunnel in use was applied. It may be said that the proposed evaluation indices, weighting, criteria and evaluation models for tunnels in use can be applied to the performance-based maintenance system of tunnels.

THE DEVELOPMENT OF INDWELLING WIRELESS PH TELEMETRY OF INTRAORAL ACIDITY (구강 내 산도의 생체 내 측정을 위한 wireless pH telemetry의 개발)

  • Kim, Hyung-Jun;Kim, Jae-Moon;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • The purpose of this study was to develop the wireless pH telemetry lasting longer than 24 hours in the mouth to overcome the limits of conventional wire telemetry previously used for salivary and plaque pH measurement, and to assess its effectiveness. We developed a wireless pH telemeter which can measure and store the pH profile data during more than 24 hours. It was composed of intraoral part; pH sensor of antimony electrode, battery and microprocessor for data storage, and extraoral part; control/data receiver and data analyzing software which was newly made for this device. After inspecting wireless electrode for accurate measurement, it was attached to the removable intraoral appliance and delivered to the volunteer who was told to wear except brushing time, retrieved after 24 hours and finally the pH profile data was extracted and analyzed. When compared with conventional wire telemetry, this device showed similar results and induced less discomfort to examinees. The data showed pH changes at same time when examinees ate various scheduled foods and beverages. With this method it became possible to accurately measure pH changes within mouth for long time in accordance with individual's lifestyle, definitely reducing the discomfort inflicted to the examinees' life.

  • PDF

Diagnosis and Sequence Analysis of Japanese yam mosaic virus from Yam (Dioscorea opposita) (마(Dioscorea opposita)에 발생한 Japanese yam mosaic virus 진단 및 염기서열 분석)

  • Lee, Joong-Hwan;Son, Chang-Gi;Kwon, Joong-Bae;Nam, Hyo-Hun;Kim, Yeong-Tae;Kim, Mi Kyeong;Lee, Su-Heon
    • Research in Plant Disease
    • /
    • v.22 no.4
    • /
    • pp.289-292
    • /
    • 2016
  • We surveyed the occurrence of Japanese yam mosaic virus (JYMV) on Yam in Gyeongsangbukdo pronvince from 2013 to 2015. The symptoms of JYMV were yellow stripes and chlorosis in yam leaves and the infection rate was ranged from 33.6% to 40.8%. We determined nucleotide sequence encoding the polyprotein of JYMV isolate BRI from yam leaves using next-generation sequencing (NGS) method. The partial nucleotide portion (7,736 nucleotides) of the genomic RNA of the JYMV isolate BRI has been sequenced (accession No. KU309315). The region sequenced includes a single open reading frame (ORF) encoding a polyprotein composed of 2,497 amino acids containing the coat protein (CP) and 3' untranslated region (UTR). The genomic organization of this isolate shows almost the same to that of other members of JYMV. The JYMV isolate BRI showed 77% to 79% nucleotide identity with the Japanese and Chinese strains and isolates. This is the first report of the genome nucleotide sequence of JYMV from Dioscorea opposita in Korea.

Monitoring of the mortalities and medications in the inland farms of olive flounder, Paralichthys olivaceus, in South Korea (양식 넙치 폐사피해 및 수산생물용 의약품 사용량 모니터링)

  • Jee, Bo Young;Shin, Ki Won;Lee, Dae Wook;Kim, Young Jae;Lee, Mu Kun
    • Journal of fish pathology
    • /
    • v.27 no.1
    • /
    • pp.77-83
    • /
    • 2014
  • The monitoring was performed to survey the mortalities and medications occurred in the inland aquaculture farms of olive flounder in South Korea from May to October, 2012. Both of the indirect inquiry for entire inland farms and the sample survey for selected farms were carried out. The aquatic organism disease inspectors, who have the national licenses for the diagnosis and prevention of aquatic organism diseases and have close relationship with the farms, investigated the rates and causes of mortalities according to the standard manual. The cumulative mortalities rate by the indirect inquiry on 565 farms, was calculated to 27.18%, and the mortalities rate by infectious diseases was 22.64%. Otherwise, the mortalities rate by sample survey on 60 farms was 25.50%, 19.33% of them were caused by infectious diseases. The high mortality rates were recorded by scuticociliatosis, non-infectious loss, streptococcosis, VHS, artificial eliminations, vibriosis and gliding bacterial disease. Streptococcosis and non-infectious mortality caused to serious loss in productivity and economy of the farms, because of their outbreaks in the flounder groups over 600 g. The monitoring of medications in the selected farms revealed that formalin for the treatment of external parasites, such as scuticociliates, was the most commonly used drugs in the farms. As the antibiotic medications, amoxicillin and florfenicol for streptococcosis, and oxytetracycline and neomycin expecting wide antibacterial spectrum, were frequently prescribed.

System Diagnosis and MEMS Driving Circuits Design using Low Power Sensors (저 전력 센서를 이용한 MEMS 회로의 구현과 시스템 효율의 진단)

  • Kim, Tae-Wan;Ko, Soo-Eun;Jabbar, Hamid;Lee, Jong-Min;Choi, Sung-Soo;Lee, Jang-Ho;Jeong, Tai-Kyeong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.1
    • /
    • pp.41-49
    • /
    • 2008
  • Many machineries and equipments are being changing to various and complicated by development of recent technology and arrival of convergence age in distant future. These various and complicate equipments need more precise outcomes and low-power consumption sensors to get close and exact results. In this paper, we proposed fault tolerance and feedback theorem for sensor network and MEMS circuit which has a benefit of energy efficiency through wireless sensor network. The system is provided with independent sensor communication if possible as unused action, using idle condition of system and is proposed the least number of circuits. These technologies compared system efficiency after examining product of each Moving Distance by developed sensor which gives effects to execution of system witch is reduced things like control of management side and requirement for hardware, time, and interaction problems. This system is designed for practical application; however, it can be applied to a normal life and production environment such as "Ubiquitous City", "Factory Automata ion Process", and "Real-time Operating System", etc.

Comparison of Sperm Morphology Evaluation Using Strict Criteria, Acrosome Reaction Following Ionophore Challenge and Zona-free Hamster Ova Sperm Penetration Assay as Prognostic Factors in Diagnosis of Male Infertility and In Vitro Fertilization (남성 불임의 진단 및 체외수정의 예후인자로서 정자 형태의 정밀 분석과 정자 첨체반응 및 햄스터 난자 침투 분석의 비교 연구)

  • Moon, Shin-Yong;Ryu, Buom-Yong;Pang, Myung-Geol;Oh, Sun-Kyung;Lee, Jae-Hoon;Suh, Chang-Suk;Kim, Seok-Hyun;Choi, Young-Min;Kim, Jung-Gu;Lee, Jin-Yong
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.29 no.1
    • /
    • pp.57-66
    • /
    • 2002
  • Objective : This study was designed to investigate the interrelationship and clinical usefulness of sperm morphology by strict criteria (SM), acrosome reaction following ionophore challenge test (ARIC) and sperm penetration assay (SPA) using zona-free hamster ova as prognostic factors in in vitro fertilization. Materials and Methods: Semen samples were provided by 83 patients undergoing IVF. We first evaluated the differences between normal fertilization group and poor fertilization group on three andrologic tests. Secondly, we analyzed the relationship between the three andrologic tests and in vitro fertilization on IVF settings. Finally, we evaluated the effectiveness of the three andrologic tests as the prognostic indicators for fertilizing ability. Results: The fertilization rate of all men in the poor fertilization group was less than 30%; but there was no evidence that this poor fertilization was due to oocyte defects. The results of three andrologic tests were significatly higher in normal fertilization group. Fertilization rate (%) in vitro was highly correlated (p<0.001) with % normal sperm by SM, ARIC value (%), and SPA result. By using Receiver-Operator-Characteristic curve (ROC), we evaluated the effectiveness of these three tests. The sensitivity and specificity of SM, ARIC test and SPA in predicting fertilization potential in IVF setting were 76% and 75%, 84% and 90%, and 76% and 95%, respectively. Conclusion: Our data suggest that the three andrologic tests can be reliable tools as prognostic factors of sperm fertilizing ability. Among these test, ARIC test and SPA gave more accurate information on fertilizing capacity. ARIC test was shown to have a predictive value for fertilizing ability comparable to that of SPA that appears to be a simple and cost-effective addition to current andrology laboratory. Combined application of these three tests may give more information on predicting sperm fertilizing capacity.

Measurement of Joint-Orientation and Monitoring of Displacement in Tunnel using 3D Laser Scanning System (3차원 레이저 스캐닝 시스템을 이용한 불연속면의 방향성 측정과 터널 변위 모니터링)

  • Shon, Ho-Woong;Oh, Seok-Hoon;Kim, Young-Kyung
    • Journal of the Korean Geophysical Society
    • /
    • v.9 no.1
    • /
    • pp.47-62
    • /
    • 2006
  • More than 70% of Korean Peninsula is consisted of mountains, so that lots of roads, rail-roads and tunnel,which play a pivotal role in the industry activity, are existed along the rock-slope and in the rock-mass. Thus,it is urgent that tegration of management system through the optimum survey and design of rock-slope excavation, proper stabilization method and database of rock-slope. However, conventional methods have shortcoming with the economy of survey time and human resources, and the overcome of difficulties of approach to the in-situ rock-slope. To overcome the limitation of conventional method, this paper proposed the development of remote measurement system using Terrestrial Laser Scanning System. The method using Terrestrial 3D Laser Scanning System, which can get 3D spatial information on the rock-slope and2)Dept. Geosystem Engineering, Kangwon National University, Korea tunnel, has an advantage of reduction of measurement time and the overcome of difficulties of approach to the in-situ rock-slope/dam/tunnel. In the case of rock-slope, through the analysis of 3D modeling of point-cloud by Terrestrial Laser Scanning System, orientation of discontinuity, roughness of joint surface, failure shape and volume were successively achieved. in the case of tunnel face, through reverse-engineering, monitoring of displacement was possible.

  • PDF

Image Evaluation Via $SUV_{LBM}$ for Normal Regions of VOI by Using Whole Body Images Obtained from PET/MRI and PET/CT (F-18 FDG PET/MRI와 PET/CT 전신 영상에서 VOI를 이용한 정상부위의 $SUV_{LBM}$-최대치에 의한 영상평가)

  • Park, Jeong-Kyu;Kim, Sung-Kyu;Cho, Ihn-Ho;Kong, Eun-Jung;Park, Meyong-Hwan
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.68-75
    • /
    • 2013
  • The purpose of this research is to compare and analyze $SUV_{LBM}$-maximum of normal regions using VOI (the volume of interest) in order to enhance the diagnostic level in whole body images of PET/CT and PET/MRI for 26 health check-up participants. In particular, we try to set up $SUV_{LBM}$-maximum data that can be used in synchronous evaluation for PET/CT and PET/MRI without contrast media. The evaluation of $SUV_{LBM}$-maximum for normal regions of whole body PET/CT and whole body PET/MRI shows that the image of PET/MRI differs very significantly from the reference image of PET/CT (p<0.0001). However, they exhibit high correlations in view of statistics (R>0.8). From this research, we suggest that the decision in the evaluation of $SUV_{LBM}$-maximum for PET/MRI should be made with the reduction of about 26.3%, while one should decide with the reduction of about 29.3% when the contrast media is used. It is helpful to interpret all image of PET/CT and PET/MRI using $SUV_{LBM}$-maximum for convenience and efficiency.

Statistical analysis of hazen-williams C and influencing factors in multi-regional water supply system (광역상수도 유속계수와 영향인자에 관한 통계적 분석)

  • Kim, Bumjun;Kim, Gilho;Kim, Hung soo
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.5
    • /
    • pp.399-410
    • /
    • 2016
  • In case of the application of Hazen-Williams C for design, operation or maintenance of water supply system, field situations always should be reflected on the factors. In this study, the relationships between C factors and influencing factors are analyzed using statistical techniques with 174 measured C factor data collected in periodic inspection for safety diagnosis in multi-regional water supply systems. To analyze their relationships, cross analysis, one-way ANOVA, correlation analysis were conducted. Analysis results showed that C factors had high correlations with both of elapsed year and pipe diameter and were relatively highly affected by coating material among influencing factors with the categorical type. On the other hand, elapsed year, pipe diameter and water type were meaningful influencing factors according to the results of multiple regression analysis. The Cluster analysis revealed that C factors had a tendency of being fundamentally classified on the basis of the elapsed year of about 20 years and the pipe diameter of 1500mm. Although C factors were generally greatly affected by elapsed year, size of pipe diameter relatively had an large influence on values of them in case of large diameter pipes. Lastly, It can be suggested that C factor estimation formulas using multiple regression analysis and clustering analysis in this study, can be applied as decision standards of C factor in multi-regional water supply systems.

Study on the energy-saving constant temperature and humidity machine operating characteristics (에너지 절감형 항온항습기 운전 특성에 관한 연구)

  • Cha, Insu;Ha, Minho;Jung, Gyeonghwan
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.27-33
    • /
    • 2016
  • The heat recovery system that was applied in this study, is the energy-saving type that can produce the maximum cooling capacity less power in use. In order to have a more precise control function the temperature and humidity of the constant temperature and humidity machine, control algorithm is applied to designed a fuzzy PID controller, and the outside air compensation device (air-cooled) demonstrated excellent ability to dehumidify the moisture, $-20^{\circ}C$ in winter. High efficiency and the low-noise type sirocco fan operate quitely and designed to fit the bottom-up and top-down in accordance with the characteristics of equipment. as a result of experiment data, the conversion efficiency is 95% or more, power recovery time is within 5sec, stop delay time is within 30sec, pump down time is 10sec, pump delay time is 5sec, heating delay time is 5sec, temperature deviation is ${\pm}2^{\circ}C$ (cooling deviation: $2^{\circ}C$, Heating deviation : $2^{\circ}C$), humidity deviation is a ${\pm}5%$ (humidification deviation 3.0%, dehumidification deviation 3.0%). Recently, ubiquitous technology is important. so, the constant temperature and humidity machine designed to be able to remotely control to via the mobile phone, and more scalable to support MMI software and automatic interface. Further, the life of the parts and equipment is extended by the failure.