Resistivity Analysis of Model Block for Using of Structure Grounding Electrode (구조체접지극 활용을 위한 모형블록의 저항률 분석)

  • Kim, Sung-Sam;Jeong, Man-Gil;Choi, Jong-Kyu;Koh, Hee-Seog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.40-45
    • /
    • 2007
  • This study analyzed the resistivity characteristic of model block to make the good use of structure grounding and substitution grounding electrode base of building. After making the model block of mortar and concrete block, it measured resistivity in hydrous condition and dry condition and compared with the blocks that is mixed earth resistance lowering agent to decrease resistivity. The resistance value of block accepted much influence by block resistivity. When the block resistivity was same or similar value, the value of soil resistivity has occurred as different as the value of grounding resistance.

Three-Dimensional Subsurface Resistivity Profile using Electrical Resistance Tomography for Designing Grounding Grid (접지 그리드 설계를 위한 전기 저항 단층촬영법에 기반한 지표의 3차원 저항률 분포 추정)

  • Khambampati, Anil Kumar;Kim, Kyung Youn
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.4
    • /
    • pp.117-128
    • /
    • 2016
  • Installation of earth grounding system is essential to ensure personnel safety and correct operation of electrical equipment. Earth parameters, especially, soil resistivity has to be determined in designing an efficient earth grounding system. The most common applied technique to measure soil resistance is Wenner four-point method. Implementation of this method is expensive, time consuming and cumbersome as large set of measurements with variable electrode spacing are required to obtain a one dimensional resistivity plot. It is advantageous to have a method which is of low cost and provides fast measurements. In this perspective, electrical resistance tomography (ERT) is applied to estimate subsurface resistivity profile. Electrical resistance tomograms characterize the soil resistivity distribution based on the measurements from electrodes placed in the region of interest. The nonlinear ill-posed inverse problem is solved using iterated Gauss-Newton method with Tikhonov regularization. Through extensive numerical simulations, it is found that ERT offers promising performance in estimating the three-dimensional soil resistivity distribution.

Apparent Soil Resistivity Calculation Using Complex Image Method (복소수이미지 방법을 이용한 겉보기 대지저항률 계산)

  • Kim, Ho-Chan;Boo, Chang-Jin;Kang, Min-Jae
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.318-321
    • /
    • 2019
  • The apparent soil resistivity is used for estimating multilayer soil parameters, such as, layer's depth and soil resistivity. The apparent soil resistivity can be measured, and also can be calculated if soil parameters are given, becacuse the apparent soil resistivity is a function of these parameters. Therefore, any optimization algorithms can be used to find these parameters which make the calculated apparent soil resistivity close to the measured one. The equation for calculating the apparent soil resistivity is complicated and time consumed, because it is composed of an infinite integral which includes a zero order Bessel's function of the first kind. In this paper, a fast algorithm for calculating the apparent soil resistivity of horizontal multilayer earth structure has been presented using complex image method.

Make-up of Equivalent Circuit of Grounding System using Water Resistivity in Hemispherical Electrode System (반구형 전극계에서 물의 저항률을 이용한 접지시스템의 등가회로 구성)

  • Lee, Bok-Hee;Choi, Jong-Hyuk;Bae, Sung-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.109-115
    • /
    • 2008
  • A design criterion of grounding systems is commonly based on the ground resistance measured with low frequency in Korea. When lightning surges which have high frequency components are injected into the grounding system, the grounding impedance is great]y different from the static grounding resistance. In order to investigate the effect of water resistivity on the high frequency performance of grounding systems, this paper presents the frequency-dependent admittance using water tank simulating the grounding system in different water resistivities. As a result, because of capacitive effect admittances and conductance are increased with increasing frequency in higher water resistivity of greater than 500[${\Omega}{\cdot}m$]. On the other hand, admittances and conductances are decreased with increasing frequency due to inductive effect in lower water resistivity of less than 500[${\Omega}{\cdot}m$]. The phase difference between the current and voltage increases in the range of 200[kHz] to 5[MHz]. Consequently, frequency-dependent performance of grounding systems is closely related to the soil resistivity, it is necessary to consider the effect of grounding system performance on the frequency and soil resistivity.

Study of the Tracking Fire Risk by Dust Resistivity of Pens (축사별 먼지 저항률에 따른 트래킹화재 위험성에 관한 연구)

  • Park, Kwang-Muk;Bang, Sun-Bae;Kim, Jae-Hyun;Park, Jin-Yeong
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.99-104
    • /
    • 2016
  • In animal and plant facilities, dust samples were collected from cattle sheds, pigsties and hen-houses, which have high proportion of electrical fires. The samples were diluted in distilled water and water resistivity was measured. Current measurements and tracking reappearance experiments were conducted using distilled water with dust samples. The analysis results were obtained to track the fire risks according to the dust resistivity. The highest value was the dust from cattle sheds followed in order by the dust of pigsties and hen-houses. In experiments measuring the temperature change and RMS current, the lower resistivity of water showed a significant trend of temperature and high amperage. In the tracking reappearance experiment with the lower resistivity water, the tracking speed was fast and the ignition time was shortened. This study investigated why each dust resistivity shows different results.

Optimization of Semiconducting Layer in Cable Transformer (케이블 변압기용 케이블의 반도전층 최적화에 관한 연구)

  • Bae, B.H.;Woo, J.S.;Kim, H.I.;Hahn, J.H.;Kwon, M.S.;Kwon, Y.A.
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.93-95
    • /
    • 2005
  • 케이블 변압기용 케이블에는 반도전층이 설치되며 권선의 각 턴에 대하여 외측 반도전층을 접지함으로써 권선에 과다 전계가 인가되는 것을 억제하는 역할을 한다. 케이블 변압기는 케이블의 반도전층의 저항률에 따라 전계분포 및 전력손실이 다른 특성을 나타낸다. 반도전층의 저항률이 매우 높을 경우 각 턴에 인가되는 전계에 의해 각 턴의 접지 사이에 높은 전계가 인가되고, 저항률이 매우 낮을 경우 반도전층에서 높은 전력 손실을 야기하여 변압기의 전체 효율을 감소시키게 된다. 따라서 반도전층의 저항률을 적절히 선정함으로써 전체 변압기의 절연특성과 효율을 최적화 할 필요가 있다. 본 연구에서는 유한요소법과 진화전략을 적용하여 케이블 변압기용 케이블의 반도전층 최적화를 수행한다.

  • PDF

Frequency-Dependent Resistivity and Relative Dielectric Constant of Soil on Water Content (수분함유량에 따른 토양의 저항률 및 비유전율의 주파수의존성)

  • Choi, Jong-Hyuk;Cha, Eung-Suk;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.98-104
    • /
    • 2010
  • In order to evaluate the performance of a grounding system against lightning or fault currents including high frequency components, the grounding impedance should be considered rather than the steady state ground resistance. To evaluate the ground impedance, the frequency dependence of resistivity and relative dielectric constant of the soil have to be analyzed. This paper deals with the frequency dependence of the resistivity and relative dielectric constant of three types of soil on water content. As a result, the resistivity of soil is getting lower with increasing of water content. It is nearly independent of the frequency in the range less than 1[MHz], and is decreased over the frequency range above 1[MHz]. On the other hand, the relative dielectric constant is rapidly decreased with the frequency in the range less than 1[MHz], but it is nearly independent on the frequency over the range of 1[MHz]. It was found from the experiments that the frequency-dependant resistivity and relative dielectric constant of soil should be considered when designing the grounding systems for protection from lightning or switching surges.

A Study on the Identification of Specific Earth Resistivity for Grounding Design of 500 KV Transmission Towers (500 kV 송전철탑 접지설계를 위한 대지저항률 산정에 관한 연구)

  • Choi, Jong-Kee;Lee, Sung-Doo;Lee, Dong-Il;Jung, Gil-Jo;Kim, Kyung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.703-705
    • /
    • 2005
  • 접지설계에 있어서 토양의 전기적 특성은 접지극의 형상과 더불어 가장 중요한 설계요소 중 하나이며 이러한 토양의 전기적 특성은 접지극이 매설될 지역의 고유한 저항률, 즉 고유저항률(specific earth resistivity)로 대표되어 왔다. 이처럼 고유저항률에 근거한 수작업 접지설계는 복잡한 구조와 특성을 갖는 실제 토양을 균일한 매질로 등가화하는 절차를 필요로 한다. 본 논문에서는 미얀마 500 kV 송전철탑 수작업 접지설계를 위하여 수평다층토양을 균일매질로 등가화하는 절차를 제시하였다.

  • PDF

Effects of Soil Resistivity on the Grounding Characteristics (대지 저항률이 접지 특성에 미치는 영향)

  • Jung, Yeon-Ha;Jang, Tae-Jun;Kwak, Hee-Ro;Roh, Young-Su;Choi, Chung-Seog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.74-79
    • /
    • 2005
  • In this paper the earth structures of four cities are analysed on the basis of the measured soil resistivity and the characteristics of a grounding system is examined. As a result it is revealed that the soil resistivity has an effect on touch voltage and step voltage, which are directly related to safety, as well as ground resistance.

Strain Analysis by Measured Displacement Data (측정 변위를 이용한 변형률 해석)

  • Kim, Tae Nam
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.4
    • /
    • pp.147-155
    • /
    • 2002
  • To find the safety and serviceability of bridges, it must consider the behaviour of structural member and evaluation of the exact resistance of the member subjected to external loads. To evaluate the behaviour and the resistance of the structural member, it must measure the strains and displacements of the structures. Usually we use the strain gauge to measure the strains. When, the bridge is long span and high pier, the setting of strain gauge is very difficult and not economic. It is not recommendable for the use of strain gauge, when the structural member has many cracks and moisture. Thus, to make up for this demerits, the algorithm of strain analysis by measured displacements data is proposed.