• 제목/요약/키워드: 임플란트의 직경

검색결과 100건 처리시간 0.025초

임플란트 직경이 골유착에 미치는 영향에 관한 연구 (INFLUENCE OF IMPLANT DIAMETER ON THE OSSEOINTEGRATION OF IMPLANTS : AN EXPERIMENTAL STUDY IN RABBITS)

  • 이준호;신상완;권상호
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.169-181
    • /
    • 2003
  • Statement of problem : The survival rate of wide diameter implants was lower than of 3.75-mm implants in some clinical researches. Purpose : The purpose of this study was to investigate the influence of implant diameter on the osseointegration of implants in the rabbit femoral condyle and tibial metaphyses by means of removal torque measurements and histomorphometric analysis. Material and Method : Ten adult New Zealand White rabbits were used in this study Two 3.75-mm diameter implants were inserted through one cortical layer in the tibial metaphyses and one 3.75-mm diameter implant was inserted in the femoral condyle. 5.0-mm diameter implants were inserted in the other leg in the same manner. A total of 60 implants (3.75-mm diameter implants:30 : 5.0-mm diameter implants:30) were installed. After a healing time of 4 and 12 weeks, the peak removal torque values required to shear off the implants were recorded. From the removal torque values (Ncm) obtained, the mean shear stress ($N/mm^2$) was calculated. And the percentage of direct bone-to-implant contact and the percentage of bone area inside the thread were measured by Kappa Image Base-metreo. The Student's t-test was undertaken for statistical analysis (p<0.05). Results : The removal torque value of 5.0-mm diameter implants was higher than of 3.75-mm diameter implants (p<0.05). The difference of shear stress value between 3.75-mm and 5.0-mm diameter implants was not statistically significant (p>0.05). The percentage direct bone-to-implant contact had no statistical difference between two groups (p>0.05). The percentage of bone area inside the thread had no statistical difference between two groups (p>0.05). Conclusion It is concluded that the quality f osseointegration is not influenced by increasing implant diameter.

가이드 수술용 템플릿을 위한 5축 정밀가공공정의 정확성에 관한 연구 (Accuracy of 5-axis precision milling for guided surgical template)

  • 박지만;이태경;정제교;김용;박은진;한종현;곽재영;김성균;허성주
    • 대한치과보철학회지
    • /
    • 제48권4호
    • /
    • pp.294-300
    • /
    • 2010
  • 연구 목적: 컴퓨터-가이드 임플란트 수술은 전통적인 방법에 비해 여러 가지 장점을 가진다. 본 연구의 목적은 가이드 수술용 템플릿 제작을 위한 좌표동기화 5축 정밀가 공공정의 정확도를 범용 CAD 소프트웨어를 통해 역설계공학의 방법으로 평가하는 것이다. 연구 재료 및 방법: 악궁 형태의 모형에 거타퍼쳐 스타핑을 매식한 10 개의 모형을 만들고 상부에 실리콘 인상재를 이용하여 인공치은을 덮어 스타핑의 위치를 보이지 않게 가렸다. 모형의 하면에 동기화를 위한 좌표동기화 형상을 만든 뒤 Cone beam CT에서 3차원 영상을 얻었다. 임플란트 계획 소프트웨어의 CT 이미지 상에서 매식된 스타핑과 동일한 방향으로 스타핑의 1/2 깊이까지 가상의 시술계획을 하고, 스타핑의 방향벡터와 저지점 (1/2지점) 데이터를 석고모형의 영상으로 좌표동기화 하였다. 이후 모형하면의 좌표동기화 형상을 이용하여 가공기기상의 좌표로 좌표변환을 통해 가공좌표동기화를 하였다. 5축 밀링머신의 좌표동기화판에 모형을 고정한 후, 동기화된 가공데이터에 의거하여 스타핑과 동일한 직경의 드릴로 계획된 벡터와 깊이로 정확히 가공 하였다. 모델에 정확히 안착되는 인상트레이를 CT 장비에 미리 고정한 상태에서, 인상트레이에 모델을 적합하여 이미지를 획득한 뒤 3차원 재구성하는 방법으로 영상을 중첩하여 비교 분석하였다. SolidWorks (Dassault Systems, Concord, USA) 범용 CAD 상에 영상을 불러들여 역설계공학의 방법으로 실린더 상부, 하부의 중점에서의 위치편차와 각도편차를 조사하였다. 통계는 SPSS (release 14.0, SPSS Inc., Chicago, USA)를 이용하여 각 편차 사이의 상관관계를 분석하였다 ($\alpha$ = 0.05). 결과: 위치 편차로 인하여 모든 드릴 보어 (bore)에서 상부 1/2에 잔존하는 거타퍼쳐의 일부를 관찰할 수 있었다. 실험 모형상에서 계획된 이미지와 드릴링 후CT에서 역설계를 거친 이미지 사이의 위치편차는 상부에서 0.31 (0.15 - 0.42) mm, 하부에서 0.36 (0.24 - 0.51) mm, 각도편차는 1.62 (0.54 - 2.27)$^{\circ}$이었다. 실린더 상부와 하부 위치 편차는 양의 상관관계를 가졌다 (Pearson Correlation Coeffocient = 0.904, P= .013). 결론: 좌표동기화 5축 정밀가공 공정은 가이드 수술용 템플릿을 제작하는 데에 적합한 정확도를 가진다.

나노튜브 $TiO_2$ 층 생성 후 전석회화 처리한 Ti-6Al-7Nb 합금의 생체활성도 (Bioactivity of precalcified nanotubular $TiO_2$ layer on Ti-6Al-7Nb alloy)

  • 서재민
    • 대한치과보철학회지
    • /
    • 제49권1호
    • /
    • pp.16-21
    • /
    • 2011
  • 연구 목적: 높은 외력이 작용하는 부위의 임플란트 재료로서 사용되고 있는 Ti-6Al-7Nb 합금의 골유착을 개선하기 위한 방법의 하나로서 나노튜브 $TiO_2$ 층 생성하고 전석회화 처리한 다음 유사체액 중에서의 활성도를 알아보고자 하였다. 연구 재료 및 방법: 양극산화처리는 glycerol에 20 wt% $H_2O$와 1 wt% $NH_4F$를 혼합하여 준비한 전해질 수용액에 전압 20 V, 전류밀도 20 mA/$cm^2$의 조건에서 1시간동안 통전하였다. 전석회화처리는 $80^{\circ}C$$Na_2HPO_4$ 수용액에 30분 동안 침적하고, 이어서$100^{\circ}C$$Ca(OH)_2$ 포화 수용액에 30분 동안 침적하였으며, $500^{\circ}C$에서 2시간 동안 열처리하였다. 전석회화처리 후 표면층의 생체활성도를 조사하기 위해 $36.5^{\circ}C$, pH 7.4의 유사체액에 10일 동안 침적하였다. 결과: 1. 나노튜브 $TiO_2$ 층은 높은 자기정렬 형태를 갖고 큰 직경의 튜브들 사이 공간에 상대적으로 작은 직경의 튜브들이 생성되는 형태로 치밀한 구조를 이루었으며, 상부에서 하부로 갈수록 직경 감소를 보였다. 2.1 wt% $NH_4F$와 20 wt% $H_2O$를 함유하는 glycerol 전해액에서 20V의 전압을 인가하여 생성된 나노튜브들의 평균 길이는 $517.0{\pm}23.2\;nm$를 보였다. 3. 나노튜브 $TiO_2$ 층의 생체활성도는 $80^{\circ}C$의 0.5 M$Na_2HPO_4$ 수용액과 $100^{\circ}C$$Ca(OH)_2$ 포화 수용액에 침적하는 전석회화처리 군의 경우에 크게 개선되어, 아파타이트의 석출 과정에서 나타나는 치밀한 돌기상과 이들을 가로지르는 미세 균열상이 관찰되었다. 결론: Ti-6Al-7Nb 합금을 나노튜브 $TiO_2$ 층 생성 후 전석회화 처리한 결과 생체활성도가 개선되었다.

분사처리 후 양극산화 처리한 임플란트 표면이 골모 유사 세포의 반응에 미치는 영향 (The effect of blasting and anodizing-combined treatment of implant surface on response of osteoblast-like cell)

  • 서보용;김영민;최재원;윤미정;전영찬;정창모;김규천;허중보
    • 대한치과보철학회지
    • /
    • 제53권1호
    • /
    • pp.9-18
    • /
    • 2015
  • 목적: 본 연구는 Tricalcium phosphate 입자를 사용한 모재분사 후 양극산화처리를 한 임플란트 표면의 특성을 분석하고, 골모유사세포의 반응을 평가하고자 하였다. 재료 및 방법: 직경 10 mm, 두께 3.0 mm 크기의 Grade IV 타이타늄 디스크를 시편으로 사용하였으며, 양극산화처리(ASD)군, 모재 분사 후 양극산화(RBM/ASD)군, 대조군(machined surface)으로 나누어 표면처리하였다. 표면처리 후 FE-SEM, 에너지분산분광기와 주사전자현미경을 사용하여 표면특성을 평가하였다. 세포의 부착을 평가하기 위해 골모유사세포를 이용해 crystal violet assay를 통해 세포부착을 평가하고, 세포 형태는 공초점 레이저 현미경을 사용하여 관찰하였다. 세포증식을 평가하기 위해 XTT 시험을, 세포분화는 역전사 중합효소연쇄반응을 사용하였으며 침착된 칼슘의 양을 측정하기 위해 Alizarin red S stain 을 이용하였다. 비교분석은 one-way ANOVA (SPSS version 18.0)로 유의수준 5%에서 검정하였다. 결과: ASD군과 RBM/ASD군에서, 분화구 모양의 표면 형상이 나타났으며, 대조군과 비교하여 산소와 인산 이온이 관찰되었다. 단위면적당 거칠기는 대조군에서 $0.08{\pm}0.04{\mu}m$, ASD군에서 $0.52{\pm}0.14{\mu}m$, RBM/ASD군에서 $1.45{\pm}0.25{\mu}m$를 보였다. 세포반응실험에서, ASD군과 RBM/ASD군이 대조군에 비해 세포의 부착정도가 높았으며 대조군이 세포증식에서 가장 높은 값을 보였다(P<.05). RT-PCR 실험에서, RBM/ASD군이 다른 군들보다 높은 ALP를 보였다(P<.05). ASD군과 비교했을 때 RBM/ASD군은 세포부착과 증식 정도에서 큰 값을 보였다(P<.05). 결론: 본 연구의 한계내에서 모재분사 후 양극산화 처리한 티타늄 표면 처리 방식이 단순 양극산화 처리한 군이나 대조군보다 골모유사세포의 반응에 효과적인 방법임을 확인하였다.

Bone-Anchored Hearing Aid Implant에 대한 1.5 T와 3.0 T에서 MRI 안전성의 생체외 평가 (In Vitro Assessment of MRI Safety at 1.5 T and 3.0 T for Bone-Anchored Hearing Aid Implant)

  • 연규진;김현수;이승근;이태수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.19-25
    • /
    • 2017
  • 본 연구는 1.5 T와 3.0 T Magnetic Resonance Imaging에서 Bone-Anchored Hearing Aid (BAHA) implant의 수평인력, 회전력, 그리고 자화감수성 인공물의 크기를 표준측정 방법에 의해 측정하여 MR 안전성을 평가하였다. BAHA implant의 고정장치와 지지대는 0.5%의 철(iron)이 포함 된 티타늄으로 만들어졌으며, 길이는 10 mm (고정장치 4 mm, 지지대 6 mm), 최대 직경은 7.0 mm이다. 수평인력 측정장치와 자화감수성 인공물 측정장치는 각각 American Society for Testing and Materials (ASTM) F2052-06, F2119-07을 참조하여 아크릴을 이용해 제작했으며, 회전력 측정은 원형 플라스틱 용기를 이용한 측정장치를 사용하였다. 자기유도에 의한 BAHA implnat의 수평인력은 주자장이 가장 큰 지점인 96 cm지점에서 최대 변위각을 측정하였고, 회전력은 원형용기 내부의 $45^{\circ}$간격의 실선 위에 놓았을 때 나타난 회전형태를 정성적 평가기준으로 측정하였다. 자화감수성 인공물은 황산구리($CuS0_4$) 용액이 채워진 용기의 중앙에 BAHA implant를 매달아 영상을 획득한 후 Susceptibility Artifact Measurement (SAM) software를 이용해 크기를 측정하였다. 측정결과 수평인력은 1.5 T와 3.0 T에서 변위각과 변위력은 모두 0으로 나타났다. 회전력은 1.5 T에서는 0(no torque), 3.0 T에서는 +1(mild torque)로 나타났다. 자화감수성 인공물은 최소 13.20 mm, 최대 38.91 mm의 크기로 나타났다. 따라서 1.5 T, 3.0 T의 MR 환경에서 BAHA implant는 환자에게 안전하다.

재생된 골에 식립한 넓은 직경의 나사형 임플란트에 대한 유한요소법적 분석 (FINITE ELEMENT ANALYSIS OF WIDE DIAMETER SCREW IMPLANT PLACED INTO REGENERATED BONE)

  • 김수관;김재덕;김종관;김병옥
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권3호
    • /
    • pp.248-254
    • /
    • 2005
  • The purpose of this study was to investigate the distribution of stress within the regenerated bone surrounding the implant using three dimensional finite element stress analysis method. Using ANSYS software revision 6.0 (IronCAD LLC, USA), a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The $5.0{\times}11.5-mm$ screw implant (3i, USA) was used for this study, and was assumed to be 100% osseointegrated. And it was restored with gold crown with resin filling at the central fossa area. The implant was surrounded by the regenerated type IV bone, with 4 mm in width and 7 mm apical to the platform of implant in length. And the regenerated bone was surrounded by type I, type II, and type III bone, respectively. The present study used a fine grid model incorporating elements between 250,820 and 352,494 and nodal points between 47,978 and 67,471. A load of 200N was applied at the 3 points on occlusal surfaces of the restoration, the central fossa, outside point of the central fossa with resin filling into screw hole, and the functional cusp, at a 0 degree angle to the vertical axis of the implant, respectively. The results were as follows: 1. The stress distribution in the regenerated bone-implant interface was highly dependent on both the density of the native bone surrounding the regenerated bone and the loading point. 2. A load of 200N at the buccal cusp produced 5-fold increase in the stress concentration at the neck of the implant and apex of regenerated bone irrespective of surrounding bone density compared to a load of 200N at the central fossa. 3. It was found that stress was more homogeneously distributed along the side of implant when the implant was surrounded by both regenerated bone and native type III bone. In summary, these data indicate that concentration of stress on the implant-regenerated bone interface depends on both the native bone quality surrounding the regenerated bone adjacent to implant and the load direction applied on the prosthesis.

성견에서 교정적 고정원으로서의 티타늄 미니스크류에 대한 연구 (A Study on Titanium Miniscrew as Orthodontic Anchorage : An experimental investigation in dogs)

  • 윤병수;최병호;이원유;김경남;심형보;박진형
    • 대한치과교정학회지
    • /
    • 제31권5호
    • /
    • pp.517-523
    • /
    • 2001
  • 교정치료에서 원하는 치아이동을 위해서는 안정된 고정원이 필요한데 티타늄 미니스크류가 매식과 제거가 쉽고, 구강 내 여러 부위에서 적용이 가능하고, 환자가 느끼는 불편감이나 비용적인 부담이 적고, 제거 후에 치유가 빠르게 진행될 수 있는 등의 장점이 있어 최근에 교정적 고정원으로 사용되기 시작하였다. 티타늄 미니스크류를 교정적 고정원으로 사용한 임상 예들이 여러 편 발표되었는데 미니스크류의 이완이 가장 큰 실패의 원인으로 보고되고 있다. 그러나 지금까지 보고된 논문들에서 교정적 고정원으로 안정성을 줄 수 있는 스크류의 식립 길이에 관한 연구가 없는 상태이다. 교정적 고정원으로 미니스크류를 효과적으로 사용하기 위해서는 식립 부위에 따른 골구조와 골밀도 차이를 고려한 식립 길이에 관한 기준이 필요하다. 이에 본 연구에서는 성견의 상악골과 하악골에서 직경 2mm 티타늄 미니스크류를 다양한 길이로 식립하고 교정력을 적용한 후 그 안정성을 평가하여 교정적 고정원으로 사용될 수 있는 미니스크류의 식립 길이를 결정하고자 하였다. 미니스크류가 상악에서는 6mm 이상, 하악에서는 4mm 이상이 골 내에 식립될 때 8주 동안 200g의 교정력에 동요도나 위치변화를 보이지 않았다. 식립 부위로는 부착치은 부위 치근 사이에 식립될 때 구강청결이 유지되고 미니스크류 주변 치은조직에 자극을 주지 않아 정상적인 조직으로 유지 될 수 있었다. 또한 교정력 적용 8주 후 치근단 방사선 사진검사에서 스크류 주변 치근 흡수나 치조골 흡수, 치주 인대 손상이 관찰되지 않았다. 따라서 상$\cdot$하악 골밀도와 골구조의 차이를 고려하여 미니스크류의 골내 식립 길이를 적절히 조절함으로써 교정적 고정원으로 티타늄 미니스크류가 효과적으로 사용될 수 있다고 생각된다. 통계적으로 유의한 차이를 보였으나 Sn-Pg line와 Sn perp. 에서부터의 거리에는 차이가 없었다(p$44.32\%$ 떨어진 거리에 위치하였고, 피질골 절단술 시행시에 저항중심의 수직적 위치는 치경부에서 치근단 쪽으로 치근 길이의 $46.38\%$ 떨어진 거리에 위치하여 피질골 절단술 시행하지 않은 경우보다 치근단 쪽으로 이동되었으며, 후방견인력의 크기 변화에 따라 저항 중심의 수직적 위치는 변하지 않았다.Stainless Steel의 순이었다. 5. 비틀림실험은 0.016x0.022의 경우 Unitek Resilient가 가장 비틀림에 대한 저항이 큰데, 64.8회의 회전후 파절한다. 그 다음으로 Jinsung Stainless Steel, Unitek Hi-T, Ormco Stainless Steel, Unitek Standard(50.6회) 순이었다. 0.019x0.025의 경우 Jinsung Stainless Steel이 가장 커서 83.2회의 회전에 저항하고, Unitek Resilient, Unitek Standard의 순이고 Ormco와 Unitek Hi-T가 가장 저항력이 작았다. 6. 주사전자현미경으로 본 표면은 모든 제품에서 생산과정 중에 보이는 압흔과 pitting이 관찰되는데, 진성기업의 Stainless Steel은 가늘고 긴 압흔이 있으며 비교적

  • PDF

티타늄에 대한 레진과 도재의 결합 강도에 관한 연구 (The study on the shear bond strength of resin and porcelain to Titanium)

  • 박지만;김영순;전슬기;박은진
    • 대한치과보철학회지
    • /
    • 제47권1호
    • /
    • pp.46-52
    • /
    • 2009
  • 연구목적: 최근 임플란트 상부보철물의 주재료로서 티타늄의 수요가 증가하고 있고, 급속도로 발전하고 있는 CAD/CAM (computer - aided design/computer-aided manufacturing) 기술이 접목되어 티타늄을 절삭하여 제작하는 방법이 주목을 받고 있으며 치과 임상에서 점점 그 영역이 넓어지고 있다. 다만, 하나의 티타늄괴를 절삭하여 만드는 방법의 특성상 기계적 유지력을 얻을 수 있는 비드 등을 형성할 수 없고, 통상적인 재료인 금 합금이나 도재용 합금 주조체에 비해 도재와의 결합력도 떨어지는 것이 보완해야 할 점으로 지적되고 있다. 이에 본 연구는 절삭형 티타늄을 이용한 보철물 제작에 많이 사용되고 있는 열중합 의치상 레진, 간접 복합 레진, 도재와 Grade II 순수 티타늄 사이의 결합 강도를 비교 평가해 보고자 하였다. 연구 재료 및 방법: 지름 9 mm, 높이 10 mm의 Grade II 순수 티타늄 원통형 시편 37개를 3군으로 나누어 각각 직경 7 mm, 높이 1 mm의 열중합 의치상 레진 (Lucitone 199, DENTSPLY Trubyte, York, USA), 간접 복합 레진 (Sinfony, 3M ESPE, Seefeld, Germany), 도재 (Triceram, Dentaurum, Ispringen, Germany)와 결합시켰다. 시편은 $5-55^{\circ}C$에서 1000회 열순환 처리 후, 범용 시험기 (Instron, Universal Testing Machine, Model 4465, USA)를 이용하여 1 mm/min의 속도로 하중을 가하여 전단결합강도를 측정하였다. 파절된 단면의 양상을 관찰하고 각 군별 파절양상을 조사하였다. 측정값은 one-way ANOVA와 Scheffe's multiple range test (${\alpha}=0.05$)로 분석하였다. 결과: 열중합 의치상 레진인 Lucitone 199 ($17.82{\pm}5.13\;MPa$)의 결합 강도가 가장 높았으며, 도재인 Triceram ($12.97{\pm}2.11\;MPa$), 복합레진인 Sinfony ($6.00{\pm}1.31\;MPa$) 순으로 감소하였다. Lucitone 199와 Sinfony 군의 파절 양상은 대부분이 부착성 파절인 데에 반해 Triceram 군에서는 복합성 파절이 많았다. 결론: CAD/CAM을 이용한 절삭형 티타늄 구조물 상방에 전장용 심미 재료로는 열중합형 의치상 레진이 가장 강한 결합 강도를 보인다. 기존의 주조체의 유지구 등에서 얻는 강도에 비해 약하고, 부착성 파절이 많은 점 등은 향후 이들 재료와 티타늄간의 결합력을 높이기 위한 보다 많은 연구가 이루어져야 할 것을 시사한다.

브레이징 온도 변화에 따른 $ZrO_2$와 Ti-6Al-4V의 접합 특성 (Brazing characteristics of $ZrO_2$ and Ti-6Al-4V brazed joints with increasing temperature)

  • 기세호;박상윤;허영구;정재필;김원중
    • 대한치과보철학회지
    • /
    • 제50권3호
    • /
    • pp.169-175
    • /
    • 2012
  • 연구 목적: 온도 변화에 따른 $ZrO_2$와 Ti-6Al-4V의 접합 특성에 대해 알아보기 위하여 새로운 브레이징 합금을 제조하고, 브레이징 온도가 접합 특성에 미치는 영향에 대하여 조사하고자 하였다. 연구 재료 및 방법: 본 연구에서 사용된 시편으로는 실험용 $ZrO_2$ 모재(ZirBlank-PS, Acucera, Inc., Gyeonggi-do, Korea)는 소결 전의 블록형태($65mm{\times}36mm{\times}12mm(t)$)이며, 이를 잘라 사포(#2400)로 표면연마 후 소결하였다. 소결된 $ZrO_2$ 시편의 크기는 $3mm{\times}3mm{\times}3mm(t)$이다. Ti-6Al-4V 모재(Ti 6Al 4V ELI CG Bar, TMS, Washington, USA)는 직경 $10mm{\times}5mm(t)$를 사용하였다. 소결된 $ZrO_2$와 Ti-6Al-4V의 접합을 위하여 브레이징 합금을 제조하였다. 시편을 3군으로 나누어 A군은 $700^{\circ}C$에서, B군은 $750^{\circ}C$에서, C군은 $800^{\circ}C$에서 각각 브레이징 하였다. 브레이징 부의 두께와 결함율의 측정은 각 군당 하나의 시편으로 각 시편 당 5회씩 반복 측정하여 평균값을 취하였다. 결과: 브레이징 합금을 사용하여 진공 브레이징을 수행한 결과 $ZrO_2$ 와 Ti-6Al-4V 는 $700^{\circ}C-800^{\circ}C$에서 양호한 접합을 보였다. 브레이징 후 브레이징 온도 변화에 따른 브레이징 부의 두께 및 결함율의 변화는 SEM을 사용하여 측정하였다. 브레이징 온도가 $700^{\circ}C$에서 $800^{\circ}C$로 증가함에 따라 CuTi 금속간 화합물 층 및 Ti-Sn-Cu-Ag계 화합물 층의 두께는 각각 $4.5{\mu}m$에서 $10.3{\mu}m$로, $3.1{\mu}m$에서 $5.0{\mu}m$로 증가되었다. 또한 브레이징 온도가 $700^{\circ}C$에서 $800^{\circ}C$로 증가함에 따라 브레이징 접합계면의 결함율은 $ZrO_2$ 및 Ti-6Al-4V 계면에서 각각 25%에서 16.3%, 5%에서 1.5%로 감소되었다. 결론: 브레이징 온도가 $700^{\circ}C$에서 $800^{\circ}C$로 증가됨에 따라, 브레이징 접합계면의 결함율은 $ZrO_2$ 및 Ti-6Al-4V 계면에서 모두 감소되었다. 이는 결함부에서 $ZrO_2$와 활성원소인 Ti과의 반응이 충분히 일어나지 않아서 브레이징 합금이 $ZrO_2$에 웨팅되지 않은 것이 원인이라고 사료된다.

지르코니아 표면에 부착된 바이오필름에 대한 LED 치솔의 항균효과 (Antimicrobial effect of toothbrush with light emitting diode on dental biofilm attached to zirconia surface: an in vitro study)

  • 박종휴;김용건;엄흥식;이시영;이재관;장범석
    • 구강회복응용과학지
    • /
    • 제35권3호
    • /
    • pp.160-169
    • /
    • 2019
  • 목적: 이번 연구의 목적은 정적인 방법과 동적인 방법으로 형성된 지르코니아 표면에 부착된 바이오필름에 대한 LED 칫솔의 항균 효과를 평가하고자 하였다. 연구 재료 및 방법: 구강 바이오필름을 형성하기 위해 직경 12 mm, 두께 2.5 mm의 지르코니아 디스크를 24-well plate(정적 방법)와 Center for Disease Control and Prevention (CDC) biofilm reactor (동적 방법)에 디스크를 넣어 바이오필름을 형성하였다. 디스크는 아무 처치도 하지 않은 대조군, 상용화된 광역학(PDT) 키트, 치솔질(brushing) 단독, LED 치솔군, LED 치솔과 에리스로신을 같이 적용한 군, 이렇게 5개 그룹으로 구성하였다. 각 군별 처치 후, 개별 디스크를 시험관에 넣고 60 초 동안 vortexing하여 세균을 분리한 후, 분리된 세균 용액을 선택 배지를 이용하여 살아있는 세균 수를 확인한 후 실험 방법에 따른 항균 효과를 계측하였고, 주사전자현미경(SEM)을 통하여 세균의 형태 변화를 관찰하였다. 결과: 바이오필름의 형성과 구성비는 동적인 방법과 정적인 방법에 따른 차이는 관찰되지 않았다. 대조군과 실험군간에 세균의 생존률에 유의한 차이가 있었다(P < 0.05). LED 치솔과 에리스로신을 같이 적용한 군에서 가장 높은 항균 효과가 관찰되었다(P < 0.05). 주사전자현미경 사진상에서 광역학치료군과, LED 치솔군, LED 치솔과 에리스로신을 같이 적용한 군은 세균의 형태 변화가 관찰되었으나, 대조군과 치솔질 단독 사용군에서는 세균의 형태 변화가 관찰되지 않았다. 결론: 이번 연구 결과 지르코니아 표면에 부착된 바이오필름을 효과적으로 제거하는 방법으로 LED 치솔과 에리스로신을 같이 적용하는 것이 추천된다.