• 제목/요약/키워드: 이온펌프

검색결과 93건 처리시간 0.023초

전기화학적 수소 압축기 기술 (A Review of Electrochemical Hydrogen Compressor Technology)

  • 김상경
    • 한국수소및신에너지학회논문집
    • /
    • 제31권6호
    • /
    • pp.578-586
    • /
    • 2020
  • There is growing interest worldwide in a hydrogen economy that uses hydrogen as an energy medium instead of hydrocarbon-based fossil fuels as a way to combat climate change. Since hydrogen has a very low energy density per unit volume at room temperature, hydrogen must be compressed and stored in order to use as an energy carrier. There are mechanical and non-mechanical methods for compressing hydrogen. The mechanical method has disadvantages such as high energy consumption, durability problems of moving parts, hydrogen contamination by lubricants, and noise. Among the non-mechanical compression methods, electrochemical compression consumes less energy and can compress hydrogen with high purity. In this paper, research trends are reviewed, focusing on research papers on electrochemical hydrogen compression technology, and future research directions are suggested.

다구역 재배용 양액 자동 조제.공급 시스템 개발 (Development of an Automatic Nutrient-Solution Mixing and Supplying System)

  • 김기영;전성필;류관희
    • 생물환경조절학회지
    • /
    • 제9권1호
    • /
    • pp.11-19
    • /
    • 2000
  • 본 연구는 다구역 양액재배에 적용할 수 있는 연속식 양액 자동조제공급 시스템 개발을 위한 목적으로 수행되었다. 기존의 정량펌프에 비해 정밀성 및 반복 구동회수에 대한 내구성이 우수하고 구동시간에 따라 토출량을 정밀 제어할 수 있는 원소별 농후액 공급조절장치를 개발하였으며, 개발된 원소별 농후액 공급조절장치의 시간당 토출량 실험 결과 결정계수는$R^2$=0.9999이었고 3초~5초 구동시간동안의 회귀식에 의한 토출량과 실제 토출량 편차를 비교한 결과 최대 -1.23%로 나타나 회귀식에 의한 구동시간에 따른 토출량 제어가 가능함이 확인 되었다. 원소별 농후액 공급조절장치의 원소별 토출량 증감을 통하여 조성이 다른 양액을 조제할 수 있었으며, 생육단계에 따른 원소별 농도의 증감 조절에 사용할 수 있을 것으로 판단된다. 원수유입량 편차 실험 결과 목표 원수유입량과 실제 원수유입량간의 편차는 2.73% 이내로 나타났다. 세척 과정을 통해 EC가 1.4~l.6mS/cm인 경우에는 0.5~0.6mS/cm, 2.4~2.5mS/cm인 경우에는 0.9~l.0mS/cm 정도로 낮추어 급액 후 잔류 양액의 영향을 줄일 수 있었다. 개발된 다구역 재배용 양액 자동조제공급 시스템의 성능을 평가하기 위하여 오이용 야마자키액 조성의 배양액 180$\ell$를 조제, 공급하였을 때 양액에 포함된 N $O_3$$^{-}$, 와 P $O_4$$^{3-}$ 이온에 대하여 실험실에서 조제한 양액의 이온 농포와의 비교 실험을 3회에 걸쳐 실시한 결과, 개발된 시스템으로 조제한 양액중에 포함된 N $O_3$$^{-}$ 이온과 P $O_4$$^{3-}$ 이온은 실험실에서 조제된 양액에 비하여 각각 2.36%, 5.15% 낮게 나타났다.

  • PDF

하이브리드/전기 자동차용 수냉식 배터리 셀의 냉각성능에 관한 수치 해석적 연구 (Numerical Investigation of Cooling Performance of Liquid-cooled Battery in Electric Vehicles)

  • 권화빈;박희성
    • 대한기계학회논문집B
    • /
    • 제40권6호
    • /
    • pp.403-408
    • /
    • 2016
  • 리튬 이온 배터리는 높은 에너지 밀도와 안정적인 충전/방전 특성을 내재하고 있어 하이드리드 및 전기자동차에 보편적으로 사용된다. 리튬 이온 배터리의 효율은 배터리 자체의 온도 특성에 직접적인 영향을 받으므로, 열을 효율적으로 냉각하는 기술이 요구된다. 본 논문에서는 수냉식 배터리 냉각 시스템의 냉각 성능과 펌프 소모동력에 관한 전산유체해석을 수행하였다. 이를 위해 배터리 셀의 냉각수 유량 및 냉각 채널의 특성에 따른 냉각 성능을 수치적으로 예측하였다. 이를 바탕으로 250개 배터리 셀을 기준으로 유량 및 차압에 의한 소모동력을 계산하였다. 이러한 연구는 차세대 하이브리드 및 전기자동차의 시간에 따른 배터리의 온도 변화 및 충/방전 효율 최적화 기술에 적용할 수 있는 기초 연구로 활용될 수 있을 것으로 기대된다.

Plasma Facing Material 흡착기체의 정량적 분석을 위한 Thermal Desorption Analyzer (TDA) 개념 설계

  • 김희수;온연길;이석관;최민식;노승정;권진중;박준규;이철의
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.513-513
    • /
    • 2012
  • 핵 융합로의 대면재질(Plasma Facing Material; PFM)은 고온의 플라즈마와 고 에너지의 이온들에 지속적으로 노출 된다. 특히 PFM은 흡착되는 기체 등에 의한 부식과 변형이 발생할 수 있다. 현재 핵 융합로 내부의 PFM으로 고려되고 있는 재질 중 하나인 고순도 탄소타일의 경우 고온의 수소동위원소 플라즈마에 직접적으로 노출되므로 이에 의한 탄소타일에 흡착되는 수소 등의 기체에 대한 정량적인 분석방법이 필요하다. 본 연구는 고순도 탄소타일 등과 같은 플라즈마 대면재료에 흡착되어 있는 물질의 정량적 분석이 가능한 TDA (Thermal Desorption Analyzer)의 개념 설계에 관한 것이다. TDA는 고온 가열($800^{\circ}C$ 이상) 및 시료 장착부 및 초고진공(~10-9 torr) 및 측정부의 두 부분으로 구성 하였다. TDA 설계시 고온 가열 및 시료 장착부는 시료 내부에 흡착되어 있는 기체의 효과적 탈착을 위한 가열 및 시료의 모양에 영향을 받지 않는 장착방법, 시료 장착부의 outgassing rate를 최소화 하는 재질 선정 등을 고려하였으며, 초고진공(~10-9 torr) 및 측정부는 초고진공 유지방법, 터보펌프 배기속도 실측을 위한 구조, 진공측정 ion 게이지, 잔류가스분석기(Residual Gas Analyzer)의 최적위치 설정 등을 고려하여 설계하였다. 개념 설계된 TDA에 대하여 발표하고자 한다.

  • PDF

마이크로 펌프 응용을 위한 이온성 고분자-금속 복합체를 이용한 멤브레인형 마이크로 액추에이터 제작에 관한 연구 (A Study on the Fabrication of a Membrane Type Micro=Actuator Using IPMC(Ionic Polymer-Metal Composite) for Micro-Pump Application)

  • 조성환;이승기;김병규;박정호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권7호
    • /
    • pp.298-304
    • /
    • 2003
  • IPMC(Ionic Polymer-Metal Composite) is a highly sensitive actuator that shows a large deformation in presence of low applied voltage. Generally, IPMC can be fabricated by electroless plating of platinum on both sides of a Nafion (perfluorosulfonic acid) film. When a commercial Nafion film is used as a base structure of the IPMC membrane, the micro-pump structure and the IPMC membrane are fabricated separately and then later assembled, which makes the fabrication inefficient. Therefore, fabrication of an IPMC membrane and the micro-pump structure on a single wafer without the need of assembly have been developed. The silicon wafer was partially etched to hold liquid Nafion to be casted and a 60-${\mu}{\textrm}{m}$ thick IPMC membrane was realized. IPMC membranes with various size were fabricated by casting and they showed 4-2${\mu}{\textrm}{m}$ displacements from $4mm{\times}4mm$ , $6mm{\times}6mm$, $8mm{\times}8mm$ membranes at the applied voltage ranging from 2Vp-p to 5Vp-p at 0.5Hz. The displacement of the fabricated IPMC membranes is fairly proportional to the membrane area and the applied voltage.

장벽 방전형 공기 펌프의 이온풍 발생에 미치는 방전전극 형상의 영향 (Effect of Discharge Electrode Shape of a Barrier Discharge Type Gas Pump on Ionic Wind Generation)

  • 황덕현;문재덕
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.994-998
    • /
    • 2009
  • Existing cooling technologies no longer provide adequate heat dissipation due to excessive heat generation caused by the growing component density on electronic devices. An ionic gas pump can be used for the thermal management of micro-electronic devices, since the size of pump can be reduced to a micrometer scale. In addition, the gas pump allows for gas flow control and generation without moving parts. This ideal property of gas pump gives rise to a variety of applications. However, all these applications require maximizing the wind velocity of gas pump. In this study a barrier discharge type gas pump, with a needle-shaped corona electrode instead of a plate-shaped corona electrode, has been investigated by focusing on the corona electrode shape on the wind velocity and wind generation yield. As a result, the enhanced wind velocity and wind generation yield of 1.76 and 3.37 times were obtained with the needle-shaped corona electrode as compared with the plate-shaped corona electrode of the proposed barrier discharge type gas pump.

$Hg^{2+}$에 의한 토마토 뿌리조직 마이크로솜 $H^+-ATPase$의 가역적 저해 ([$Hg^{2+} $-induced Reversible Inhibitions of Microsomal $H^+-ATPase$ Prepared from Tomato Roots)

  • 신대섭;조광현;김영기
    • Applied Biological Chemistry
    • /
    • 제42권4호
    • /
    • pp.298-303
    • /
    • 1999
  • 토마토 뿌리조직의 마이크로솜 ATPpase활성에 대한 중금속의 효과를 조사하기 위하여 뿌리조직으로부터 마이크로솜을 분리하였고, enzyme-coupled assay를 이용하여 마이크로솜 이온펌프(ATPase)의 활성을 측정하였다. 여러 가지 중금속 이온들 중 $Hg^{2+}$은 마이크로솜 ATPpase 활성을 농도 의존적으로 저해하였으며, $Gd^{3+}$$Fe^{3+}$, $La^{3+}$, $Zn^{2+}$, $Pb^{2+}$ 등은 마이크로솜 ATPpase의 활성을 저해하면서 동시에 assay에 사용된 효소를 저해하였다. 그러나, $Cs^+$$Ba^{2+}$은 마이크로솜 ATPpase 활성에 영향을 미치지 않았다. $Hg^{2+}$은 원형질막과 액포막에 위치하는 $H^+-ATPase$들의 활성을 $10\;{\mu}M$ 이상의 농도에서 현저히 저해하였고, 1 mM 이상의 농도에서 완전히 저해하였으며, 두 효소들에 대한 활성저해의 Ki 값은 각각 $80\;{\mu}M$, $58\;{\mu}M$로 나타났다. $Hg^{2+}$에 의해 저해된 ATPpase의 활성은 DTT의 농도를 증가시킴에 따라 회복되어, $Hg^{2+}$에 의한 ATPpase 활성저해는 가역적임을 확인하였다. 이러한 결과들은 $Hg^{2+}$이 원형질막과 액포막에 위치한 $H^+-ATPase$들을 비선택적이고 가역적으로 저해함을 보여준다.

  • PDF

고에너지 엑스선을 조사한 세포막모델에서 K+-Na+ 펌프 시스템의 능동적 전달 특성 (Active Transport Characteristics of K+-Na+ Pumping System in Cell Membrane Model which Irradiated by High Energy X-ray)

  • 고인호
    • 한국방사선학회논문지
    • /
    • 제11권2호
    • /
    • pp.157-165
    • /
    • 2017
  • 본 논문에서는 고에너지 엑스선(6MeV)을 조사한 세포막 모델에서 $K^+-Na^+$ pump 시스템의 능동적 전달특성에 대하여 연구하였다. 이 실험에 사용된 세포막 모델은 $Na^+$슬폰화 폴리스티렌-디비닐벤젠(polystyrene-divinylbenzene) 혼성 중합막을 사용하였다. 이온의 초기플럭스는 $H^+$이온 농도의 증가와 함께 증가하였다. 이 실험의 조건을 pH 1.5-5, 온도 $36.5^{\circ}C$로 하여 첫 번째, 방사선이 조사되지 않은 막에서 $K^+$의 초기플럭스는 $2.09{\times}10^{-4}-1.32{\times}10^{-3}mole/cm^2{\cdot}h$이고 $Na^+$의 초기플럭스는 $7.09{\times}10^{-4}-1.09{\times}10^{-3}mole/cm^2{\cdot}h$으로 나타내었다. 두 번째, 방사선이 조사된 막에서 $K^+$의 초기플럭스는 $21.0{\times}10^{-4}-16.7{\times}10^{-3}mole/cm^2{\cdot}h$이고 $Na^+$의 초기플럭스는 $62.0{\times}10^{-4}-20.6{\times}10^{-3}mole/cm^2{\cdot}h$으로 나타내었다. 막의 $K^+/Na^+$선택도는 약 1.10이다. 조사된 막의 pH의 추진력은 조사되지 않은 막보다 약 9-20배 정도 유의성 있게 증가하였다. 세포막모델에서 $K^+-Na^+$의 pump 시스템의 능동적 전달특성이 비정상적이기 때문에 세포장해가 세포에서 발현된다고 사료된다.

모사 탈황흡수탑을 이용한 Spray Type 탈황설비 최적운전 방안에 관한 연구 (A Study on Optimization of Spray Type Flue Gas Desulfurization (FGD) System)

  • 안희수;박승수;김기형;김영호
    • 공업화학
    • /
    • 제18권1호
    • /
    • pp.29-35
    • /
    • 2007
  • 현재 국내 화력발전소에서 운영중인 일부 배연탈황설비는 건설비 절감을 위해 설계시 여유율을 축소하여 비정상상태에 대응이 어렵고, 노후화 등으로 탈황효율이 저하하는 등 일부의 문제점이 제기되고 있다. 이러한 문제점에 대응하기 위해, 본 논문에서는 흡수액의 pH, 입구 $SO_2$ 농도, 운전 단수 변경 및 liquid distribution ring (LDR) 등의 탈황설비의 운전 조건 변경에 따른 탈황율을 검토하였으며, sulfite 이온 및 Al/Fx 이온이 석회석의 blinding에 미치는 효과에 대해 실험하였다. 흡수액 재순환 펌프를 3대 운전하였을 때는 2대 운전했을 때와 비교하여 탈황율이 최대 12% 향상하였고, LDR을 설치함에 따라 탈황효은 약 2~7%가 향상하였다. Limestone blinding 현상이 발생한 흡수액에 dibasic acid (DBA)를 500, 1,000 ppm 주입하였을 때 흡수액 용존산소가 0.5 ppm 이상 증가하며, limestone blinding 현상을 완화하였다. 흡수액 중에 $Al^{3+}$, F- 이온이 공존한 경우 석회석 용해속도는 20% 감소하였다.

HPLC-RTS (high performance liquid chromatography-retention time shift)를 이용한 암모늄 이온의 안정동위원소 측정방법의 개선 (Stable Isotope Measurement of Ammonium Using HPLC-RTS (high performance liquid chromatography-retention time shift))

  • 안순모;이지영
    • 한국해양학회지:바다
    • /
    • 제18권1호
    • /
    • pp.47-52
    • /
    • 2013
  • 생태계 질소 순환 연구에서 동위원소 추적자를 이용한 실험은 그 유용성에도 불구하고, 무기 질소의 안정동위원소 측정이 어려워 자료의 생산이 활발하지 못한 형편이다. Gardner et al. (1996)은 HPLC (high performance liquid chromatography)를 이용하여 비교적 간편하고 정밀하게 암모늄의 동위원소 비를 측정하는 방법을 개발해 질소순환 연구에 활발하게 활용하였다. 그러나 일반적이지 않은 syringe 펌프가 필요해 다른 실험실에 이 시스템이 도입되지는 못하였다. 본 연구에서는 최신 HPLC 펌프 기술을 활용하여 Dr. Gardner 그룹 이후 최초로 암모늄 동위원소비 측정 시스템을 구축하였다. 표준시료 측정 결과 RTS (retention time shift)는 안정동위원소 비와 좋은 상관관계를 보였다. 이 시스템은 측정 자료를 디지털 형태로 변환하는 장치까지 갖추어 컴퓨터 프로그램을 이용한 다양한 자료처리가 가능하다. 특히 Matlab$^{(R)}$ 이용하여 retention time 계산에 peak 면적을 이용함으로써 측정의 정확성을 높이고, 직선성을 향상할 수 있었다. 영산강 하구 해수를 가지고 실시한 $^{15}N$-암모늄 첨가 실험에서 $^{15}N/^{14}N$ 비율 변화를 HPLC-RTS법을 통해 측정하였으며, 식물성 플랑크톤에 의한 암모늄 섭취와 재광물화 과정을 각각 독립적으로 측정하는 것이 가능했다.