• Title/Summary/Keyword: 이온펌프

Search Result 93, Processing Time 0.027 seconds

A Review of Electrochemical Hydrogen Compressor Technology (전기화학적 수소 압축기 기술)

  • KIM, SANG-KYUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.6
    • /
    • pp.578-586
    • /
    • 2020
  • There is growing interest worldwide in a hydrogen economy that uses hydrogen as an energy medium instead of hydrocarbon-based fossil fuels as a way to combat climate change. Since hydrogen has a very low energy density per unit volume at room temperature, hydrogen must be compressed and stored in order to use as an energy carrier. There are mechanical and non-mechanical methods for compressing hydrogen. The mechanical method has disadvantages such as high energy consumption, durability problems of moving parts, hydrogen contamination by lubricants, and noise. Among the non-mechanical compression methods, electrochemical compression consumes less energy and can compress hydrogen with high purity. In this paper, research trends are reviewed, focusing on research papers on electrochemical hydrogen compression technology, and future research directions are suggested.

Development of an Automatic Nutrient-Solution Mixing and Supplying System (다구역 재배용 양액 자동 조제.공급 시스템 개발)

  • 김기영;전성필;류관희
    • Journal of Bio-Environment Control
    • /
    • v.9 no.1
    • /
    • pp.11-19
    • /
    • 2000
  • In recent, multi-sector nutriculture in which each sectors are managed with different compositions and supplying amounts of nutrient solution is being prevalent especially in large-scale greenhouses. This study was carried out to develop an automatic mixing and supplying system of nutrient solution for the multi-sector greenhouse which can control various compositions of nutrient solution and supplying amounts for each sector. The stock solution control device could control discharge of the stock solution with device actuating time. The experimental result showed high correlation between the discharge and the actuating time. The system could make nutrient solution of various compositions and showed possibility of changing compositions of nutrient solution according to changes of growth stages or environments. Undesirable remnant nutrient-solution effect on the next supply was decreased by lowering RC of the previous nutrient solution remaining in the tank and supply pipe through rinse process. To evaluate performance of the developed system, experiments that compare N $O_3$$^{[-10]}$ , and P $O_4$$^{3-}$ concentrations of nutrient solution made in laboratory level with those made by the developed system were conducted. The experimental results showed that the deviations for N $O_3$$^{[-10]}$ , and P $O_4$$^{3-}$ concentrations of nutrient solution composited by the developed system were -2.36% and -5.15%, respectively.

  • PDF

Numerical Investigation of Cooling Performance of Liquid-cooled Battery in Electric Vehicles (하이브리드/전기 자동차용 수냉식 배터리 셀의 냉각성능에 관한 수치 해석적 연구)

  • Kwon, Hwabhin;Park, Heesung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.6
    • /
    • pp.403-408
    • /
    • 2016
  • Lithium-ion batteries are commonly employed in hybrid electric vehicles (HEVs), and achieving high energy density in the battery has been one of the most critical issues in the automotive industry. Because liquid cooling containing antifreeze is important in automotive batteries to enable cold starts, an effective geometric configuration for high-cooling performance should be carefully investigated. Battery cooling with antifreeze has also been considered to realize successful cold starts. In this article, we theoretically investigate a specific property of an antifreeze cooling battery system, and we perform numerical modeling to satisfy the required thermal specifications. Because a typical battery system in HEVs consists of multiple stacked battery cells, the cooling performance is determined mainly by the special properties of antifreeze in the coolant passage, which dissipates heat generated from the battery cells. We propose that the required cooling performance can be realized by performing numerical simulations of different geometric configurations for battery cooling. Furthermore, we perform a theoretical analysis as a design guideline to optimize the cooling performance with minimum power consumption by the cooling pump.

Plasma Facing Material 흡착기체의 정량적 분석을 위한 Thermal Desorption Analyzer (TDA) 개념 설계

  • Kim, Hui-Su;On, Yeon-Gil;Lee, Seok-Gwan;Choe, Min-Sik;No, Seung-Jeong;Gwon, Jin-Jung;Park, Jun-Gyu;Lee, Cheol-Ui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.513-513
    • /
    • 2012
  • 핵 융합로의 대면재질(Plasma Facing Material; PFM)은 고온의 플라즈마와 고 에너지의 이온들에 지속적으로 노출 된다. 특히 PFM은 흡착되는 기체 등에 의한 부식과 변형이 발생할 수 있다. 현재 핵 융합로 내부의 PFM으로 고려되고 있는 재질 중 하나인 고순도 탄소타일의 경우 고온의 수소동위원소 플라즈마에 직접적으로 노출되므로 이에 의한 탄소타일에 흡착되는 수소 등의 기체에 대한 정량적인 분석방법이 필요하다. 본 연구는 고순도 탄소타일 등과 같은 플라즈마 대면재료에 흡착되어 있는 물질의 정량적 분석이 가능한 TDA (Thermal Desorption Analyzer)의 개념 설계에 관한 것이다. TDA는 고온 가열($800^{\circ}C$ 이상) 및 시료 장착부 및 초고진공(~10-9 torr) 및 측정부의 두 부분으로 구성 하였다. TDA 설계시 고온 가열 및 시료 장착부는 시료 내부에 흡착되어 있는 기체의 효과적 탈착을 위한 가열 및 시료의 모양에 영향을 받지 않는 장착방법, 시료 장착부의 outgassing rate를 최소화 하는 재질 선정 등을 고려하였으며, 초고진공(~10-9 torr) 및 측정부는 초고진공 유지방법, 터보펌프 배기속도 실측을 위한 구조, 진공측정 ion 게이지, 잔류가스분석기(Residual Gas Analyzer)의 최적위치 설정 등을 고려하여 설계하였다. 개념 설계된 TDA에 대하여 발표하고자 한다.

  • PDF

A Study on the Fabrication of a Membrane Type Micro=Actuator Using IPMC(Ionic Polymer-Metal Composite) for Micro-Pump Application (마이크로 펌프 응용을 위한 이온성 고분자-금속 복합체를 이용한 멤브레인형 마이크로 액추에이터 제작에 관한 연구)

  • 조성환;이승기;김병규;박정호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.7
    • /
    • pp.298-304
    • /
    • 2003
  • IPMC(Ionic Polymer-Metal Composite) is a highly sensitive actuator that shows a large deformation in presence of low applied voltage. Generally, IPMC can be fabricated by electroless plating of platinum on both sides of a Nafion (perfluorosulfonic acid) film. When a commercial Nafion film is used as a base structure of the IPMC membrane, the micro-pump structure and the IPMC membrane are fabricated separately and then later assembled, which makes the fabrication inefficient. Therefore, fabrication of an IPMC membrane and the micro-pump structure on a single wafer without the need of assembly have been developed. The silicon wafer was partially etched to hold liquid Nafion to be casted and a 60-${\mu}{\textrm}{m}$ thick IPMC membrane was realized. IPMC membranes with various size were fabricated by casting and they showed 4-2${\mu}{\textrm}{m}$ displacements from $4mm{\times}4mm$ , $6mm{\times}6mm$, $8mm{\times}8mm$ membranes at the applied voltage ranging from 2Vp-p to 5Vp-p at 0.5Hz. The displacement of the fabricated IPMC membranes is fairly proportional to the membrane area and the applied voltage.

Effect of Discharge Electrode Shape of a Barrier Discharge Type Gas Pump on Ionic Wind Generation (장벽 방전형 공기 펌프의 이온풍 발생에 미치는 방전전극 형상의 영향)

  • Hwang, Deok-Hyun;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.994-998
    • /
    • 2009
  • Existing cooling technologies no longer provide adequate heat dissipation due to excessive heat generation caused by the growing component density on electronic devices. An ionic gas pump can be used for the thermal management of micro-electronic devices, since the size of pump can be reduced to a micrometer scale. In addition, the gas pump allows for gas flow control and generation without moving parts. This ideal property of gas pump gives rise to a variety of applications. However, all these applications require maximizing the wind velocity of gas pump. In this study a barrier discharge type gas pump, with a needle-shaped corona electrode instead of a plate-shaped corona electrode, has been investigated by focusing on the corona electrode shape on the wind velocity and wind generation yield. As a result, the enhanced wind velocity and wind generation yield of 1.76 and 3.37 times were obtained with the needle-shaped corona electrode as compared with the plate-shaped corona electrode of the proposed barrier discharge type gas pump.

[$Hg^{2+} $-induced Reversible Inhibitions of Microsomal $H^+-ATPase$ Prepared from Tomato Roots ($Hg^{2+}$에 의한 토마토 뿌리조직 마이크로솜 $H^+-ATPase$의 가역적 저해)

  • Shin, Dae-Seop;Cho, Kwang-Hyun;Kim, Young-Kee
    • Applied Biological Chemistry
    • /
    • v.42 no.4
    • /
    • pp.298-303
    • /
    • 1999
  • In order to characterize the effects of heavy metal ions on the microsomal ATPase activities, microsomes were prepared from the roots of tomato plant and the activity of microsomal ATPase was measured by an enzyme-coupled assay. $Hg^{2+}$ inhibited the activity of microsomal ATPase in a dose-dependent manner, while $Gd^{3+}$, $Fe^{3+}$, $La^{3+}$, $Zn^{2+}$, and $Pb^{2+}$ inhibited not only the ATPase activity but also the activities of enzymes used in the assay. However, $Cs^+$ and $Ba^{2+}$ showed no significant effect. $Hg^{2+}$ inhibited the activities of both plasma membrane and vacuolar membrane $H^+-ATPases$. In the dose-response to $Hg^{2+}$, the activities of both microsomal $H^+-ATPases$ were severely inhibited at the concentration of $Hg^{2+}$ above $10\;{\mu}M$ and were completely inhibited at 1 mM $Hg^{2+}$. Apparent Ki values of $Hg^{2+}$ on the inhibitions of plasma membrane and vacuolar membrane $H^+-ATPases$ were $80\;{\mu}M$ and $58\;{\mu}M$, respectively. The $Hg^{2+}$-induced inhibitions were reversible since the addition of dithiothreitol completely reversed the inhibitory effects of $Hg^{2+}$. These results suggest that the inhibitory effects of $Hg^{2+}$ on both plasma, membrane and vacuolar membrane $H^+-ATPases$ are nonselective and reversible.

  • PDF

Active Transport Characteristics of K+-Na+ Pumping System in Cell Membrane Model which Irradiated by High Energy X-ray (고에너지 엑스선을 조사한 세포막모델에서 K+-Na+ 펌프 시스템의 능동적 전달 특성)

  • Ko, In-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.157-165
    • /
    • 2017
  • The active transport characteristics of $K^+$ and $Na^+$ pumping system of cell membrane model which irradiated by high energy x-ray(linac 6MeV) was investigated. The cell membrane model used in this experiment was a $Na^+$ type sulfonated copolymerized membrane of styrene and divinylbenezene. The initial flux of the ion was increased with increase of both $H^+$ ion concentration. In this experiment range(pH 1.5-5, temperature $36.5^{\circ}C$), the initial flux of $K^+$ which was not irradiated by radiation was found to be from $2.09{\times}10^{-4}$ to $1.32{\times}10^{-3}mole/cm^2{\cdot}h$ and that of $Na^+$ from $7.09{\times}10^{-4}$ to $1.09{\times}10^{-3}mole/cm^2{\cdot}h$. the initial flux of $K^+$ which was irradiated by radiation was found to be from $21.0{\times}10^{-4}$ to $16.7{\times}10^{-3}mole/cm^2{\cdot}h$ and that of $Na^+$ from $62.0{\times}10^{-4}$ to $20.6{\times}10^{-3}mole/cm^2{\cdot}h$. The ratio $K^+$/$Na^+$ of membrane was about 1.10. And the driving force of pH of irradiated membrane was significantly increased about 9-20 times than membrane which was not irradiated. As active transport of $K^+$ and $Na^+$ of cell membrane model were abnormal, cell damages were appeared at cell.

A Study on Optimization of Spray Type Flue Gas Desulfurization (FGD) System (모사 탈황흡수탑을 이용한 Spray Type 탈황설비 최적운전 방안에 관한 연구)

  • An, Hi-Soo;Park, Seung-Soo;Kim, Ki-Hyoung;Kim, Young-Ho
    • Applied Chemistry for Engineering
    • /
    • v.18 no.1
    • /
    • pp.29-35
    • /
    • 2007
  • Recently, due to narrow margin on design factor of flue gas desulfurization (FGD) systems or aging of systems, some problems such as decrease of $SO_2$ removal efficiency and difficulty on coping with unstable state are arising on FGD systems. On this study, to cope with these problems several methods such as adjustment of reagent pH, inlet $SO_2$ concentration, variation of units of operation pump, installation of liquid distribution ring (LDR) were attempted to increase the $SO_2$ removal using spray type simulated FGD system. Also, sulfite and Al/Fx ion effects on limestone blinding were experimented. When three absorber recirculation pumps were operated, $SO_2$ removal was increased by 12% in comparison with that of two pumps operation. $SO_2$ removal was increased by 2~7% after installation of LDR. Dissolved oxygen increased up to 0.5 ppm and limestone binding effect was alleviated after injection of dibasic acid (DBA) with the concentration of 500 and 1,000 ppm. When $Al^{3+}$ and $F^-$ ions were coexisting, the dissolution rate of limestone was decreased by 20%.

Stable Isotope Measurement of Ammonium Using HPLC-RTS (high performance liquid chromatography-retention time shift) (HPLC-RTS (high performance liquid chromatography-retention time shift)를 이용한 암모늄 이온의 안정동위원소 측정방법의 개선)

  • An, Soonmo;Lee, Jiyoung;Gardner, Wayne S.
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.18 no.1
    • /
    • pp.47-52
    • /
    • 2013
  • Despite the usefulness of nitrogen isotope tracer experiments in nitrogen cycling studies, there are not such many measurement data mainly due to the difficulties in analytical methods. Although Gardner et al. (1996) developed a relatively simple and accurate method that can measure ammonium isotope using HPLC and used it widely in various N dynamics studies, the technique was not adopted to other laboratories. An HPLC-RTS system using updated HPLC pumps that can perform the same measurements as that of Gardner et al. (1996) was built. The result of standard sample showed linear increase of RTS with the $^{15}N$ proportions. Centroid retention times calculated with Matlab$^{(R)}$ program enhanced the linearity of the response. In a sea water incubation experiment spiked with $^{15}NH_4{^+}$, the uptake and regeneration of ammonium could be separately estimated using the temporal change of $^{15}N/^{14}N$.