• Title/Summary/Keyword: 유동검출

Search Result 135, Processing Time 0.024 seconds

Pressure sensing of air flow using multi-walled carbon nanotubes (다중벽 탄소 나노튜브를 이용한 유동 압력 검출)

  • Song, Jin-Won;Lee, Jong-Hong;Lee, Eung-Sug;Han, Chang-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.377-383
    • /
    • 2007
  • We describe the fabrication and characterization of a doubly clamped multi-walled carbon nanotube (MWNT). The device was assembled by an application of electric field in solution. The MWNT was clamped on end of metal trench electrodes in solution and deposited with additional platinum (Pt) on edge of electrode for firmly suspending the MWNT by focused ion beam (FIB). The MWNTs range of diameter and length were 100 to 150 nm and 1.5 to $2{\mu}m$, respectively. Electrical characteristics of fabricated devices were measured by I-V curve and impedance analysis. The mechanical deformation was observed by resistivity in high air pressure. Resonant frequency around 6.8 MHz was detected and resistivity was linearly varied according to the magnitude of air pressure. This device could have potential applications in nanoelectronics and various sensors.

A Defect Detection of Irradiated Nuclear Fuel Assembly using Image Processing Technology (영상처리를 이용한 조사후 핵연료 집합체의 결함검출)

  • Cho, Jai-Wan;Choi, Young-Soo;Jeong, Kyung-Min;Shin, Jung-Cheol;Jung, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.425-426
    • /
    • 2007
  • 본 논문에서는 4 m 길이의 핵연료 집합체를 지지하는 스페이서 그리드 외관의 이상 상태를 자동으로 검출하기 위한 영상처리 알고리즘에 대해 기술한다. 원자로 가동 중에는 중성자 조사와 고온 고압 냉각수의 열 유동에 의한 물리적 작용으로 정방 격자구조로 되어 있는 연료봉이 늘어나거나 휘어져 연료봉 틈새 간격이 좁아지고 냉각수의 원활한 유동이 방해를 받게 됨에 따라 연료봉을 지지하는 스페이서 그리드의 변형이 초래될 수 있다. 스페이서 그리드 간격의 변화를 자동으로 추출하는 영상처리 알고리즘을 개발하여 스페이서 그리드의 이상 상태를 자동으로 인식할 수 있게 하였다. 실험 영상으로는 스웨덴 Ahlberg 사의 4면 검사장치에 의해 수행된 경수로형 핵연료 집합체의 검사 동영상을 이용하였다.

  • PDF

Design of a customizable fluorescence detection system for fluorescently labeled tumor cells (형광 발현 암세포 탐지를 위한 맞춤형 검출시스템 개발)

  • Cho, Kyoungrae;Seo, Jeong-hyeok;Choe, Se-woon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.3
    • /
    • pp.261-266
    • /
    • 2019
  • Flow cytometry is an electrical detection system that provides precise and diverse optical properties to cells and micro particles. Flow cytometry, which provides multidimensional information including cell size and granularity through light scattering and fluorescence emission generated by the induction of light of a specific wavelength to the fluorescently treated cells or micro particles, plays an important role in biomedical and biophysical fields. However, it has some drawbacks such as high cost, size of the instrument and limitation in selecting fluorescent dyes. Therefore, in this paper, a low cost compact fluorescent detection system is developed using light-emitting diode and microcontroller. The proposed fluorescence detection system has a replaceable the light source/fluorescence filter/photodetector and constructed by 3D printer, so that the user can design a customized system according to the selected fluorescent dyes. The fluorescence intensity was measured by varying the number of fluorescently labeled cells, and the measured intensities showed a high linearity within the tested concentration ranges.

Correlation of the Wall Skin-Friction and Streamwise Velocity Fluctuations in a Turbulent Boundary Layer(II) (난류경계층에서 벽마찰력과 유동방향 속도성분과의 상관관계(II))

  • Yang, Jun-Mo;Yu, Jeong-Yeol;Choe, Hae-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.3
    • /
    • pp.427-435
    • /
    • 1997
  • Conditional sampling techniques are utilized to investigate the relation between the wall skin-friction and stream wise velocity fluctuations in a turbulent boundary layer. Conditionally averaged results using a peak detection and the VITA (variable-interval time-averaging) technique show that a high skin friction is associated with high frequency components of the wall skin-friction fluctuations. The conditionally averaged wall skin-friction fluctuations obtained by using the VITA technique have a positively-skewed characteristics compared with the conditionally averaged stream wise velocity fluctuations. It is confirmed that there exists a phase shift between the wall skin-friction and stream wise velocity fluctuations, which was also found from the long-time averaged space-time correlations. The amount of phase shift between the wall skin-friction and stream wise velocity fluctuations is the same as that from the long-time averaged space-time correlations and does not change despite the variation of the detection threshold.

A Study on the Multi-Path Gain Adaptive MMSE Detector (다중경로 이득 적응형 MMSE 검출기에 관한 연구)

  • 유동관
    • Journal of the Korea Society of Computer and Information
    • /
    • v.9 no.2
    • /
    • pp.89-96
    • /
    • 2004
  • In this paper, an improved method is proposed by supplementing multi-path gain for detection. This method is proposed to complement the shortcomings of the conventional detection method which is used for multiuser detection in STBC(Space-Time Block Code) CDMA system. We analyzed the improved method in bit error probability viewpoint and compared the result with that of the conventional method. From this result, we showed that bit error probability of the improved method is superior to that of the conventional method when the parameters such as delay, number of user and SNR are increased.

  • PDF

Hand Detection for Front-Projected Interactive Displays (전방 투사 인터랙티브 디스플레이를 위한 맨손 검출)

  • Nam, Yang-Hee;Oh, Su-Jin
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.9
    • /
    • pp.1135-1142
    • /
    • 2007
  • Front-projection type displays make it difficult to apply traditional skin color detection for human hand because the projected beam not only reaches to the screen but also to the user's hand. This paper solves this problem by modeling the distortion between original image and its final camera input. Our approach improves hand detection rate by modeling of interference effect among color channels and of intra-frame intensity and also by introducing adaptive threshold for color difference in skin region.

  • PDF

Determination of Liquid Paraffins in Foods by Using GC-FID (GC-FID를 이용한 식품 중 유동파라핀 함량 분석)

  • Park, Se-Jong;Choi, Jae-Chun;Lim, Ho-Soo;Jang, Su-Jin;Kim, So-Hee;Kim, Meehye
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.545-549
    • /
    • 2013
  • Liquid paraffin is a mixture of heavier alkanes derived from petroleum. It can be used as a lubricant in processing machinery, as a coating agent, or as a releasing agent. The purpose of this study was to analyze liquid paraffins in foods by using a gas chromatography-flame ionized detector (GC-FID). Liquid paraffin was extracted from the food samples using n-hexane. Non-polar aromatic or olefinic co-extractives were removed by alkaline permanganate oxidation followed by clean up on an aluminium oxide SPE cartridge before the GC-FID analysis. The results of recovery tests were 91.5-103.2%. Based on this optimized method, we investigated the amount of liquid paraffin in various food samples purchased from domestic markets. The levels of liquid paraffin in bread were $95.5{\pm}156.0$ mg/kg (0.008%), those in capsules were $40.2{\pm}54.5$ mg/kg (0.001%), and those in dried fruits and vegetables were $3.0{\pm}18.1$ mg/kg (0.0001%). No liquid paraffin was detected in fresh fruits and vegetables. We propose that our method can be used to monitor and detect liquid paraffin in foods for food safety management.

LES for Turbulent Duct Flow with Surface Mass Injection (질량분사가 있는 덕트 난류유동의 LES 해석)

  • Kim, Bo-Hoon;Na, Yang;Lee, Chang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.3
    • /
    • pp.232-241
    • /
    • 2011
  • The hybrid rocket shows interesting characteristics of complicated mixing layer developed by the interaction between turbulent oxidizer flow and injected surface mass flow from fuel vaporization. In this study, the compressible LES was conducted to explore the physical phenomena of surface oscillatory flow induced by the flow interferences in a duct domain. From the numerical results, the wall injection generates the stronger streamwise vorticites and the negative components of axial velocity accompanied with the azimuthal vorticity near the surface. And the vortex shedding with a certain time scale was found to be developed by hydrodynamic instability in the mixing layer. The pressure fluctuations in this calculation exhibit a peculiar peak at a specific angular frequency($\omega$=8.8) representing intrinsic oscillation due to the injection.

Flexible Background-Texture Analysis for Coronary Artery Extraction Based on Digital Subtraction Angiography (유동적인 배경 텍스쳐 분석을 통한 DSA 기반의 관상동맥 검출)

  • Park Sung-Ho;Lee Joong-Jae;Lee Geun-Soo;Kim Gye-Young
    • The KIPS Transactions:PartB
    • /
    • v.12B no.5 s.101
    • /
    • pp.543-552
    • /
    • 2005
  • This paper proposes the extraction of coronary arteries based on DSA(Digital Subtraction Angiography) through a texture analysis of background in the angiography. DSA is a well established modality for the visualization of coronary arteries. DSA involves the subtraction of a mask image - an image of the heart before injection of contrast medium - from live image. However, this technique is sensitive to the movement of background and can result to a wrong detection by the variance of background gray-level intensity between two images. Therefore, this paper solves a structural problem resulted from a background movement bV selecting an image which has the least difference of movement through an analysis of the similarity of background texture and proposes a method to extract only the blood vessel efficiently through local gray-level correction of the selected image. Using the coronary angiogram of 5 patients clinical data, we proved that the proposed method has the lower false-detection rate, approximately $2\%$, and the higher accuracy than the existing methods.