• Title/Summary/Keyword: 와이어메쉬

Search Result 26, Processing Time 0.02 seconds

Analysis of Bending Wire Mesh (와이어메쉬 굴곡배치 타당성분석)

  • Kim, Chun-Ho;Jung, Dae-Suk
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.6
    • /
    • pp.169-174
    • /
    • 2009
  • We conducted structural analysis to investigate disadvantage of wire-mesh arranged at the plane and to develop three-dimensionally bent U-type wire-mesh. In all case that distributed loading at the whole top slab and the half top slab, and the wire mesh was bent $45^{\circ}$, flexura tensile stress was the fewest in both positive moment and negative moment, and the wire mesh was bent $45^{\circ}$ in crossway the shear stresss was the fewest. Therefore, by arranging wire-mesh with $45^{\circ}$ more bent than plane, flexura tensile stress, shear stress, displacement will be reduced and structural function will be improved.

Pyroshock Isolation Performance Test using Wiremesh Isolators (와이어메쉬 절연계의 파이로 충격 절연 성능 시험)

  • Youn, Se-Hyun;Jang, Young-Soon;Han, Jae-Hung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.9
    • /
    • pp.923-928
    • /
    • 2008
  • Pyrotechnic shock or pyroshock is characterized as a transient vibration phenomenon which shows large acceleration and high frequency range up to 10kHz during the operation of separation devices where explosives are used. During the flight of a launch vehicle, pyroshock is mainly generated at several events such as satellite separation, fairing separation and stage separation. In this paper, wiremesh isolators are introduced and several types of isolators are manufactured for the performance tests. For the investigation of typical characteristics of wiremesh isolators, compressive loading tests are basically performed and pyroshock tests are accomplished to confirm pyroshock isolation ability of each wiremesh isolator by using 4Kg dummy mass.

Geometric LiveWire and Geometric LiveLane for 3D Meshes (삼차원 메쉬에 대한 기하학 라이브와이어와 기하학 라이브레인)

  • Yoo Kwan-Hee
    • The KIPS Transactions:PartA
    • /
    • v.12A no.1 s.91
    • /
    • pp.13-22
    • /
    • 2005
  • Similarly to the edges defined in a 2D image, we can define the geometric features representing the boundary of the distinctive parts appearing on 3D meshes. The geometric features have been used as basic primitives in several applications such as mesh simplification, mesh deformation, and mesh editing. In this paper, we propose geometric livewire and geometric livelane for extracting geometric features in a 3D mesh, which are the extentions of livewire and livelane methods in images. In these methods, approximate curvatures are adopted to represent the geometric features in a 3D mesh and the 3D mesh itself is represented as a weighted directed graph in which cost functions are defined for the weights of edges. Using a well-known shortest path finding algorithm in the weighted directed graph, we extracted geometric features in the 3D mesh among points selected by a user. In this paper, we also visualize the results obtained from applying the techniques to extracting geometric features in the general meshes modeled after human faces, cows, shoes, and single teeth.

Bending Behaviour of Composite Slab Using a New-Shaped Steel Deck Plate and Expanded Metal (신형 데크플레이트와 철판망을 적용한 합성슬래브의 휨 거동)

  • Kim, Myoung Mo;Eom, Chul Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.4 s.65
    • /
    • pp.403-412
    • /
    • 2003
  • The composite metal deck plate system has been widely used for office structures. Recently, however, the flat deck plate has been developed to apply the composite slab system to residential structures. Reduction in construction cost and time can be expected by using expanded metal instead of wire mesh as crack control reinforcements. This study proposed a composite slab system composed of a new-shaped steel deck plate and expanded metal. Twelve specimens were tested to evaluate the structural performance of the new composite slab system. The test results were summarized mainly in terms of maximum load carrying capacity and failure behaviors of each specimen.

Realistic 3D Facial Expression Animation Based on Muscle Model (근육 모델 기반의 자연스러운 3차원 얼굴 표정 애니메이션)

  • Lee, Hye-Jin;Chung, Hyun-Sook;Lee, Yill-Byung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.04a
    • /
    • pp.265-268
    • /
    • 2002
  • 얼굴은 성별, 나이, 인종에 따라 다양한 특징을 가지고 있어서 개개인을 구별하기가 쉽고 내적인 상태를 쉽게 볼 수 있는 중요한 도구로 여겨지고 있다. 본 논문은 얼굴표정 애니메이션을 위한 효과적인 방법으로 실제얼굴의 피부조직 얼굴 근육 등 해부학적 구조에 기반한 근육기반모델링을 이용하는 방법을 소개하고자 한다. 제안하는 시스템의 구성은 얼굴 와이어프레임 구성과 폴리곤 메쉬분할 단계, 얼굴에 필요한 근육을 적용시키는 단계, 근육의 움직임에 따른 얼굴 표정생성단계로 이루어진다. 와이어프레임 구성과 폴리곤 메쉬 분할 단계에서는 얼굴모델을 Water[1]가 제안한 얼굴을 기반으로 하였고, 하나의 폴리곤 메쉬를 4등분으로 분할하여 부드러운 3D 얼굴모델을 보여준다. 다음 단계는 얼굴 표정생성에 필요한 근육을 30 개로 만들어 실제로 표정을 지을 때 많이 쓰는 부위에 적용시킨다. 그 다음으로 표정생성단계는 FACS 에서 제안한 Action Unit 을 조합하고 얼굴표정에 따라 필요한 근육의 강도를 조절하여 더 자연스럽고 실제감 있는 얼굴표정 애니메이션을 보여준다.

  • PDF

Development and Performance Evaluation of the Expanded Metal Rockfall Protection Fence

  • Hwang, Young-Cheol;Kim, Bum-Joo;Noh, Heung-Jae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.3
    • /
    • pp.35-45
    • /
    • 2005
  • The rockfall protection fence is one of the most common rockfall protection methods in Korea. The typical rockfall protection fence consists mainly of three parts ; H-beam supports, wire meshes, and wire ropes. The design of the rockfall protection fence is made such that the total energy absorbing capacity of the fence. Therefore, resulting from the combined energy absorbing capacity of the three parts is larger than the falling energy of rocks. In present study, a new rockfall protection fence, constructed using expanded metals instead of the existing wire rope and wire mesh for the typical type of rockfall protection fence, was evaluated on its performance by conducting both laboratory and field tests. Also, for a comparison, the same tests were performed on the typical rockfall protection fence. The test results revealed that the expanded material is an economic alternative to the existing protection materials and the expanded metal rockfall protection fence exhibits the higher energy absorbing capacity compared to that of the typical rockfall protection fence.

  • PDF

Response of Bridge Piers Retrofitted by Stainless Steel Wire under Simulated Seismic Loading (내진 모사하중에 의한 스테인레스강 와이어 보강 교각의 응답)

  • Choi, Jun Hyeok;Kim, Sung Hoon;Lee, Do Hyung
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.4
    • /
    • pp.343-350
    • /
    • 2009
  • In the present study, a new seismic retrofitting method that employs both a stainless steel wire mesh and a permeable polymer concrete mortar was proposed for reinforced concrete bridge piers with nonseismic design details. For this purpose, a total of six nonseismically designed bridge piers were tested under lateral load reversals. The test results reveal that nonseismically designed piers with lap splices need to be retrofitted to resist earthquake induced forces. In addition, it was proven that the proposed retrofitting method can be useful in improving the strength, stiffness, and energy dissipation capacities of bridge piers designed nonseismically. It is thus expected that the proposed method may provide an improved ductility capacity without sudden softening of strength for bridge piers excursing inelastic displacement range.

Shear Performance Evaluation of the Joint between Hollow Core Slabs (Hollow core 슬래브 간 접합부의 전단저항성능 평가)

  • Hong, Geon-Ho;Baek, Jong-Sam;Park, Hong-Gun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.94-101
    • /
    • 2010
  • Recently, the interest of precast concrete is increased for rapid construction in construction fields. Experimental study about the shear performance of the joint between hollow core slabs which have internal core to reduce their weight was performed. Main test variables were thickness of the topping concrete and existence of the wiremesh. Total 8 specimens including 4 in-plane shear and 4 out of plane shear were tested. Test results were analyzed in terms of cracking load, failure load, failure aspect, stiffness and ductility, and compared its design load to develop optimum design details. Test results indicated that the shear performance of the non-shrinkage mortar specimen was similar to that of 30mm thickness topping concrete specimen, and the effect of wiremesh reinforcement did not affect the failure load or stiffness of the specimens but the increase of ductility. And this paper presents the comparison results of the test results and design load to provide the optimum detail of the joint design between the hollow core slabs.

An Experimental Study on Performance of the Fixed-type OWC Chamber for Wave-Energy Conversion (고정식 파력발전용 OWC챔버의 성능파악을 위한 실험적 연구)

  • B.S. Hyun;P.M. Lee;D.S. Gong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.28 no.2
    • /
    • pp.318-328
    • /
    • 1991
  • The present paper describes the experimental study on the fixed-type wave-energy conversion system, consisting of the OWC-type wave-energy absorbing chamber and the duct for the air turbine. For simplicity, a screen of wire mesh was employed in place of an air turbine in order to simulate its effects on OWC chamber. Experiments were performed at the towing tank in regular waves with the frequency range of 0.22-0.75Hz. Comparison wish the numerical prediction using a potential flow-based method [4] was made to validate the capability of numerical code. It was shown that the agreements between measured and calculated results are quite good, giving a confidence in prediction method. Simulation of air turbine using a wire-mesh screen was successful, at least in a qualitative sense, to investigate the inter action between the OWC chamber and an air turbine. Results also showed that the effects of a wire-mesh screen on chamber efficiency are negligible, and the present model can be effectively utilized for the practical use in ocean waves with the frequency range under 0.3Hz.

  • PDF

Elastic Modulus Extraction of Wire Mesh for Vibration Mount Development (방진마운트 개발을 위한 와이어 메쉬 탄성계수 추출)

  • Kim, Tae-Yeon;Shin, Yun-ho;Moon, S.J.;Jung, B.C.;Lee, T.J.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.7
    • /
    • pp.806-813
    • /
    • 2016
  • To alleviate the vibration problem or to satisfy the required criteria for manifesting the guaranteed performance of precise equipment, various vibration isolation materials or apparatus, such as viscoelastic material, air and coil spring, have been developed and applied. Among them, a wire mesh material is regarded as one of the good candidate for reducing the vibration in terms of moderate material price, easy shape machining and long life cycle without the property deterioration induced by the aging or environmental effects. In this paper, prior to wire mesh isolator design, the static and dynamic elastic modulus of wire mesh materials are extracted from the experiment by the simple shaped cylindrical specimens and their characteristics for applying to vibration isolator design are examined. The simple shaped specimens were made as considering the design parameters of a wire mesh mount; i.e. the density, wire diameter and wire mesh slope, and the sensitivity analysis were also performed from a view point of the extracted elastic modulus.