Browse > Article
http://dx.doi.org/10.5345/JKIC.2009.9.6.169

Analysis of Bending Wire Mesh  

Kim, Chun-Ho (중부대학교 토목공학과)
Jung, Dae-Suk (중부대학교 토목공학과)
Publication Information
Journal of the Korea Institute of Building Construction / v.9, no.6, 2009 , pp. 169-174 More about this Journal
Abstract
We conducted structural analysis to investigate disadvantage of wire-mesh arranged at the plane and to develop three-dimensionally bent U-type wire-mesh. In all case that distributed loading at the whole top slab and the half top slab, and the wire mesh was bent $45^{\circ}$, flexura tensile stress was the fewest in both positive moment and negative moment, and the wire mesh was bent $45^{\circ}$ in crossway the shear stresss was the fewest. Therefore, by arranging wire-mesh with $45^{\circ}$ more bent than plane, flexura tensile stress, shear stress, displacement will be reduced and structural function will be improved.
Keywords
wire mesh; bent wire mesh;
Citations & Related Records
연도 인용수 순위
  • Reference
1 건설교통부. 도로공사 설계적용기준. 2001
2 한국콘크리트학회. 콘크리트구조설계기준 해설. 2003
3 Timoshenko. Mechanics of Materials, PWS Publishin, 1997
4 Chu-Kia Wang. Reinforced Concrete Design, Wang Salmon, 1983
5 한국콘크리트학회. 토목구조물의 배근상세. 2000
6 James G. Macgregor. Reinforced Concrete Mechanics and Design, Prentice Hall, 1999