Response of Bridge Piers Retrofitted by Stainless Steel Wire under Simulated Seismic Loading  

Choi, Jun Hyeok (대한컨설탄트 철도부)
Kim, Sung Hoon (서울산업대학교 토목공학과)
Lee, Do Hyung (배재대학교 건설환경철도공학과)
Publication Information
Journal of Korean Society of Steel Construction / v.21, no.4, 2009 , pp. 343-350 More about this Journal
Abstract
In the present study, a new seismic retrofitting method that employs both a stainless steel wire mesh and a permeable polymer concrete mortar was proposed for reinforced concrete bridge piers with nonseismic design details. For this purpose, a total of six nonseismically designed bridge piers were tested under lateral load reversals. The test results reveal that nonseismically designed piers with lap splices need to be retrofitted to resist earthquake induced forces. In addition, it was proven that the proposed retrofitting method can be useful in improving the strength, stiffness, and energy dissipation capacities of bridge piers designed nonseismically. It is thus expected that the proposed method may provide an improved ductility capacity without sudden softening of strength for bridge piers excursing inelastic displacement range.
Keywords
seismic retrofitting; stainless steel wire mesh; permeable polymer concrete mortar; bridge piers;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 정영수, 박종협, 박희상, 조창백 (2002) 섬유보강 원형 철근콘크리트 교각의 내진성능 향상에 관한 유사동적 실험, 콘크리트학회논문집, 한국콘크리트학회, 제14권 제2호, pp.180-189   DOI
2 Sheikh, S.A. (2002) Performance of concrete structures retrofitted with fibre reinforced polymers, Engineering Structures, Vol. 24, pp.869-879   DOI   ScienceOn
3 Xiao, Y., Wu, H. (2003) Retrofit of reinforced concrete columns using partially stiffened steel jackets, Joournal of Structural Engineering, ASCE, Vol. 129, No. 6, pp.725-732   DOI   ScienceOn
4 이대형, 정영수, 이재형, 송호진 (2002) 주철근 겹침이음된 형상비 4.0의 원형 철근콘크리트 교각의 내진성능평가, 대한토목학회논문집, 대한토목학회, 제22권 제 5A호, pp.1193-11202
5 Priestley, M.J.N., Seible, F., Xiao, Y., Verma, R. (1994b) Steel jacket retrofitting of reinforced concrete bridge columns for enhanced shear strength-Part 2: test results and comparison with theory, ACI Structural Journal, Vol. 94, No. 4, pp.537-551
6 정영수, 이대형, 고성현, 이재훈 (2004) 주철근 겹이음된 실물비내진 원형교각의 내진성능 평가, 콘크리트학회 논문집,한국콘크리트학회, 제 16권 제 5호, pp.697-708
7 서울산업대학교 (2005) 격자망 와이어 메쉬와 고강도 침투성 폴리머 몰탈로 보강된 콘크리트 구조물(기둥)의 내진성능평가, 서울산업대학교 건설기술연구소
8 Priestley, M.J.N., Seible, F., Xiao, Y., Verma, R. (1994a) Steel jacket retrofitting of reinforced concrete bridge columns for enhanced shear strength-Part 1: theoretical considerations and test design, ACI Structural Journal, Vol. 94, No. 4, pp.394-405
9 염광수, 최상현, 이영호, 이학은 (2005) 강판피복과 CFRP를 이용한 손상된 교각의 내진보수, 한국지진공학회논문집, 한국지진공학회, 제9권 제3호, pp.69-75   DOI
10 이재훈, 손혁수, 고성현 (2004) 축방향철근 연결상세에 따른 철근콘크리트 원형교각의 내진성능, 콘크리트학회논문집, 한국콘크리트학회, 제16권 제2호, pp.249-260   DOI
11 Chai, Y.H., Priestley, M.J.N., Seible, F. (1991) Seismic retrofit of circular bridge columns for enhanced flexural performance, ACI Structural Journal, Vol. 88, No. 5, pp.572-584