• Title/Summary/Keyword: 오존 $(O_3)$농도

Search Result 156, Processing Time 0.022 seconds

The Removal of Natural Organic Matter and Disinfection By-Product Precursor by Ozone (오존처리에 의한 천연유기물질 변화 및 염소 소독부산물 전구물질 제어)

  • Son, Hee-Jong;Roh, Jae-Soon;Kim, Sang-Goo;Kang, Lim-Seok;Lee, Yong-Doo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1099-1107
    • /
    • 2005
  • The purpose of this study was to find the transformation of organic matter as well as chlorine by product formation potential with ozone dosage. The removal percents of $UV_{254}$ and DOC were $23%{\sim}65%$ and $2%{\sim}15%$ and THMFP and HAAFP were $17%{\sim}52%$ and $9%{\sim}29%$ respectively at $0.5{\sim}3\;mgO_3/mgDOC$ ozone dosage. The hydrophobic and transphobic organic matter were reduced to $37%{\sim}68%$ and $35%{\sim}64%$, on the other hand the hydrophilir organic matter was increased to $40%{\sim}49%$ at $0.5{\sim}3\;mgO_3/mgDOC$ ozone dosage. The produced THMFP and HAAFP from the hydrophobic and transphilic organic matter were decreased greatly with increasing ozone dosage but these by products were increased in the hydrophilic matter. The produced THMFP and HAAFP per unit DOC were decreased and reactivity was reduced greatly with increasing crone dosage. The removal rate of THMFP per unit DOC was much higher than HAAFP by ozone treatment. The Br-THMFP per unit DOC was much more removed than chloroformFP per unit DOC with increasing ozone dosage. and The removal rate of TCAAFP per unit DOC was increased with increasing ozone dosage but TCAAFP was not affected by ozone treatment. Br-HAAFP was decreased at $1\;mgO_3/mgDOC$ ozone dosage but was not more removed above $1\;mgO_3/mgDOC$ ozone dosage. Br-HAAFP had lower removal effect than Br-THMFP by ozone treatment. The optimal ozone dosage can be determined about $1\;mgO_3/mgDOC$ by considering both disinfection by product formation and economical efficiency.

Removal of Odorous Compounds Using Ozone and Hydrogen Peroxide (오존과 과산화수소를 이용한 이취미 물질 산화 제거)

  • Lee, Hwa-Ja;Son, Hee-Jong;Roh, Jae-Soon;Lee, Sang-Won;Ji, Ki-Won;Yu, Pyung-Jong;Kang, Lim-Seog
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.12
    • /
    • pp.1323-1330
    • /
    • 2006
  • In this study, five different odor causing compounds in the Nakdong river and rapid sand filtered waters were treated by oxidation from $O_3/H_2O_2$ process. In addition, the change in BDOC formation by the $O_3/H_2O_2$ process was also investigated for considering this advanced oxidation Process as a pre-treatment to the BAC treatment process. The experimental result showed that the removal efficiency of geosmin was higher with the use of 5 mg/L of $O_3$ and 0.2 mg/L of $H_2O_2$ than with the use of 20 mg/L of $O_3$ alone for the sand filtered water. And in general, the removal efficiency of geosmin in raw water was $12{\sim}27%$ lower than the one in sand filtered water. In sand filtered water. the removal efficiencies of geosmin and IPMP decreased when $H_2O_2/O_3$ ratio increases above the optimum ratio. The optimum ratio of $H_2O_2/O_3$ dose was $0.5{\sim}1.0$ for geosmin and $0.2{\sim}1.0$ for IPMP. However, the optimum ratio of $H_2O_2/O_3$ in raw water remove geosmin appealed to $1.0{\sim}3.0$. According to the experimental results for the removal of 5 different odor causing compounds under varied $O_3$ doses, the removal efficiency of IPMP was the highest with 60% and, in overall, $O_3/H_2O_2$ process showed higher removal efficiency than $O_3$ alone process. The BDOC formation by the $O_3/H_2O_2$ process increased from $0.1{\sim}0.25$ to $0.19{\sim}0.34$ comparing to $O_3$ process alone. Therefore, it is concluded that the advanced oxidation process with $O_3/H_2O_2$ can be used as a pretreatment to the BAC treatment process.

Removal Characteristics of Synthetic Musk Compounds in Water by Ozone Treatment (오존처리에 의한 수중의 인공 사향물질 제거특성)

  • Seo, Chang-Dong;Son, Hee-Jong;Yoom, Hoon-Sik;Lee, Sang-Won;Ryu, Dong-Chun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.2
    • /
    • pp.73-78
    • /
    • 2012
  • In this study, three different synthetic musk compounds (SMCs) in the Nakdong river water (raw water) and rapid sand filtered water were treated by $O_3$ process. The experimental results showed that the removal efficiency of musk ketone (MK) was lower than removal efficiency of AHTN (7-acetyl-1,1,3,4,4,6-hexamethyl-1,2,3,4-tetrahydronaphthalene) and HHCB (1,3,4,6,7,8-hexahydro-4,6,6,7,8,8-hexamethylcyclopenta[c]-2-benzopyran) for both the raw water and the rapid sand filtered water. And in general, the removal efficiencies of three SMCs in the raw water were lower than that in the sand filtered water. Under the $O_3$ dose of 0.5~10.0 mg/L, the removal rate constants (k) of three SMCs for the raw and sand filtered waters increased rapidly with the increased $O_3$ dose. In the case of drinking water treatment plants (DWTPs) which were selected pre- and post-$O_3$ processes (located in the downstream of Nakdong River), operation conditions of pre- and post-$O_3$ process were $0.5{\sim}2.0mg{\cdot}O_3/L$ (2~4 min) and $0.5{\sim}2.5mg{\cdot}O_3/L$ (6~8 min). Therefore, $O_3$ doses and contact times of same conditions with above were very difficult to remove SMCs in DWTPs.

Oxidation of Geosmin and 2-MIB in Water Using $O_3/H_2O_2$: Kinetic Evaluation (오존과 과산화수소를 이용한 Geosmin과 2-MIB 산화: 동력학적 평가)

  • Lee, Hwa-Ja;Son, Hee-Jong;Roh, Jae-Soon;Lee, Sang-Won;Ji, Ki-Won;Yoo, Pyung-Jong;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.7
    • /
    • pp.826-832
    • /
    • 2007
  • Unpleasant tastes and odors in drinking water cause same problems for water utilities across Korea. Even though tastes and odors do not create health problems, they are main concerns for consumers who determine the safety of their drinking water. In this study, two different odor producing compounds(geosmin 2-MIB) in the Nakdong river water and rapid sand filtered rater were treated by advanced oxidation of $O_3/H_2O_2$ process. The experimental results showed that the removal efficiency of geosmin with the use of 5 mg/L of $O_3$ and $H_2O_2$ was higher than efficiency with the use of $O_3$ alone for both the raw water and the sand filtered water. And in general, the removal efficiency of geosmin was higher than 2-MIB in the sand filtered water. Under the range of $O_3$ concentration $0.5\sim2.0$ mg/L, the removal rate constants(k) of geosmin for the raw and sand filtered waters, and the one of 2-MIB in the sand filtered water were increased rapidly as doses of $O_3$, and $H_2O_2$, increased. The removal rate constants(k) do not increase any more when $H_2O_2/O_3$ ratio increases above the optimum ratio. The optimum ratio of $H_2O_2/O_3$, dose was $1.0\sim2.0$ for both geosmin and 2-MIB. The removal rate constant(k) becomes lower when OH radical consuming materials are present in raw water. The half-life of geosmin decreased rapidly as the $O_3$ and $H_2O_2$ doses increase in the sand filtered water. The half life decreased about 8.5 times with the use of 2 mg/L of $O_3$ and 10 mg/L of $H_2O_2$ than with the use of 2 mg/L of $O_3$ alone for the sand filtered water.

Prediction of $O_3$ Concentration According to the Distribution of Pressure Patterns, Pusan (기압배치 형태별 부산지역 오존농도 예측)

  • 안미정;이동인
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.155-156
    • /
    • 2000
  • 대기오염물질 중 오존은 대기성분 간의 화학반응에 의하여 광화학스모그를 형성하는 주요한 가스로서 지금까지 오존의 생성과 대기오염물질 및 기상과의 상관성을 이용한 오존 예측 연구가 다양하게 이루어져 왔다. 국내에서는 회귀모형을 이용한 오존농도 예측(허정숙등, 1993), 신경회로망을 이용한 오존농도 예측(김용국 등, 1994), Wavelet Transform을 이용한 단기오존농도 예측(김신도, 1998)등이 있고, 국외에서는 단기 오존예측(Feister & Balzer; 1991), 선형모델을 이용한 오존예측(Cox, Chu, 1992), 비선형모델을 이용한 오존예측(Peter et, 1995)등이 있다. (중략)

  • PDF

Investigation of SO2 effect on OMI-TOMS and OMI-DOAS O3 in volcanic areas with OMI satellite data (OMI 위성자료를 이용한 화산지역 고농도 이산화황 환경에서의 TOMS 오존과 DOAS 오존의 비교연구)

  • Choi, Wonei;Hong, Hyunkee;Park, Junsung;Kim, Daewon;Yeo, Jaeho;Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.6
    • /
    • pp.599-608
    • /
    • 2015
  • In this present study, we quantified the $SO_2$ effect on $O_3$ retrieval from the Ozone Monitoring Instrument (OMI) measurement. The difference between OMI-Total Ozone Mapping Spectrometer (TOMS) and OMI-Differential Optical Absorption Spectrometer (DOAS) total $O_3$ is calculated in high $SO_2$ volcanic plume on several volcanic eruptions (Anatahan, La Cumbre, Sierra Negra, and Piton) from 2005 through 2008. There is a certain correlation ($R{\geq}0.5$) between the difference and $OMI-SO_2$ in volcanic plumes and the significant difference close to 100 DU. The high $SO_2$ condition found to affect TOMS $O_3$ retrieval significantly due to a strong $SO_2$ absorption at the TOMS $O_3$ retrieval wavelengths. Besides, we calculated the difference against various $SO_2$ levels. There is the considerable difference (average = 32.9 DU; standard deviation = 13.5 DU) in the high $OMI-SO_2$ condition ($OMI-SO_2{\geq}7.0DU$). We also found that the rate of change in the difference per 1.0 DU change in middle troposphere (TRM) and upper troposphere and stratosphere (STL) $SO_2$ columns are 3.9 DU and 4.9 DU, respectively.

Removal of Chloramphenicol, Salicylic Acid and Ketoprofen using Various Oxidation Processes : Oxidation Kinetic Evaluation (다양한 산화공정을 이용한 수중의 Chloramphenicol, Salicylic Acid 및 Ketoprofen 의약물질 제거 : 산화 동력학 평가)

  • Son, Hee-Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.2
    • /
    • pp.219-226
    • /
    • 2010
  • In order to evaluate a removal characteristic of chloramphenicol, salicylic acid and ketoprofen according to dose of oxidants, $Cl_2$, $O_3$ and $O_3/H_2O_2$ are used as oxidants in this study. In case of that $Cl_2$ is used for oxidizing harmaceuticals, chloramphenicol, salicylic acid and ketoprofen is not removed entirely at $Cl_2$ dose rang of 0.5~5.0 mg/L for 60 min. However, removal tendency of salicylic acid is so obviously at $Cl_2$ dose higher than 1.0 mg/L. In addition, as $Cl_2$ dose and contact time increase, the removal rate of salicylic acid is enhanced. When $O_3$ is used as oxidant, chloramphenicol and ketoprofen is not eliminated at $O_3$ dose range of 0.2~2.0 mg/L. On the contrary, 30~70% of salicylic acid is removed at $O_3$ dose of 1.0~5.0 mg/L. Only 30% removal of salicylic acid is achieved at contact time of 5 min, however, the removal rate is enhanced remarkably at contact time over 10 min. In experiments using $O_3/H_2O_2$ as an oxidant, we can find that $O_3/H_2O_2$ is much more effective than $O_3$ only for removal of 3 pharmaceuticals, and the efficiency is raised according to increase of $H_2O_2$ dose. On reaction rate constant and half-life of 3 pharmaceuticals depending on $Cl_2$, $O_3$ and $O_3/H_2O_2$ dose, experiments using $O_3/H_2O_2$ show that oxidation of pharmaceuticals is less effective as the $H_2O_2/O_3$ ratio increases to above pproximately 1.0 related to reaction rate constant. An oxidation of salicylic acid by $Cl_2$ and $O_3$ particularly has a comparatively high reaction rate constant comparing $O_3/H_2O_2$, and thus salicylic acid is easily eliminated in oxidation processes.

Formation Characteristics of $BDOC_{rapid}$ and $BDOC_{slow}$ by Ozonation (오존처리에 의한 $BDOC_{rapid}$$BDOC_{slow}$ 생성 특성)

  • Son, Hee-Jong;Jung, Chul-Woo;Choi, Young-Ik;Bae, Sang-Dae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.12
    • /
    • pp.1274-1279
    • /
    • 2006
  • The formation characteristics of $BDOC_{rapid}$ and $BDOC_{slow}$ with different ozone dosages for 3 different kinds of waters from Maeri raw water in the down stream of Nakdong river, Hoidong reservoir water in Busan City and treated Maeri raw water(sand filtered) has been investigated in this study. The ozone dosages for producing maximum $BDOC_{total}$ in the Maeri raw water, Hoidong reservoir water and sand filtered water of Maeri were 0.9, 1.1 and 1.4 $mgO_3$/mgDOC respectively. It could be concluded that the ozone dosages for formations of maximum $BDOC_{total}$ were determined by characteristics of water. The ozone dosages for producing maximum $BDOC_{rapid}$ in the Maeri raw water, Hoidong reservoir water and sand filtered water of Maeri were 0.9, 0.9 and 1.0 $mgO_3$/mgDOC respectively that were same or lower than the used ozone dosages for producing maximum $BDOC_{total}$. $BDOC_{slow}$ was being formated and increased continuously with the higher ozone dosages which were the used ozone dosages for maximum formation of $BDOC_{total}$ and $BDOC_{rapid}$. For the best results of a pre-treatment of biofiltration, the optimum ozone dosage ranges in formation of $BDOC_{rapid}/BDOC_{total}$ were $0.6{\sim}1.0\;mgO_3$/mgDOC that were lower than the ozone dosage ranges of $0.9{\sim}1.4\;mgO_3$/mgDOC for the maximum formation $BDOC_{total}$. The reported results indicated that the best and effective ways from economic and technical points of view to determine the optimum ozone dosages of the pretreatment of biofilteration process were investigating and classifying BDOC.

A Study on the Solubilisation of Excess Sludge using Microbubble Ozone (잉여슬러지 가용화를 위한 마이크로버블 오존 이용에 관한 연구)

  • Lee, Shun-Hwa;Jung, Kye-Ju;Kwon, Jin-Ha;Lee, Se-Han
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.325-332
    • /
    • 2010
  • This study was conducted with the experiment of solubilisation of excess sludge by microbubble ozone process. To improve ozone contact efficiency, microbubble ozones which its diameter were the avearge 30 ${\mu}m$, microbubble size less than 40 ${\mu}m$ occupied about over 90% of all. In treating sludge using microbubble ozones, in case microbubble ozones are injected at microbubble ozone dosage of 0.34 g $O_3/g$ SS or less regardless of sludge concentration, microbubble ozone consumption rate was found to be 100% with no emission of waste ozones. In treating sludges by each concentration, in case the initial SS concentration of sludge is set to 6,447 mg/L, 5,557 mg/L, 3,180 mg/L, 1,092 mg/L and 515 mg/L, the amount of removed SS tended to increase with increase in initial SS concentration for the same microbubble ozone dosage, and treatment of sludge with high initial SS concentration was effective in raising the oxidation efficiency of microbubble ozones. On the other hand, as a result of reviewing acid, alkali and microbubble ozone treatment as composite treatment of sludge, use of acid treatment for the pre-treatment of microbubble ozone was more effective than alkali treatment, and in case of treatment at microbubble ozone dosage 0.05g $O_3/g$ SS with the concentration of sulfuric acid infused in the sludge, the amount of removed SS, 153.9 g, was 1.9 times more than 81.2 g the amount of single treatment of microbubble ozone.

Fabrication of $In_2O_3$-based oxide semiconductor thick film ozene gas sensor ($In_2O_3$ 계 산화물 반도체형 후막 오존 가스센서의 제조)

  • 이규정
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.1
    • /
    • pp.19-24
    • /
    • 1999
  • $In_2O_3$-based thick films for the ozone detection of ppb range have been investigated. The $In_2O_3$ sensing layer is quite sensitive to ozone, but the saturated stable sensitivity cannot be obtained at the ozone exposure of 100 ppb for 5 min. The addition of $Fe_2O_3$ into $In_2O_3$ indicates some improvement in response time and sensitivity, but it seems the improvement is not good enough for real applications. Firing of $In_2O_3$:$Fe_2O_3$ powder induces remarkable improvement in response and recovery, although the sensitivity decrease. The sensing layer fired at $1300^{\circ}C$ and operated $550^{\circ}C$ shows excellent properties of fast response time, saturated stable sensitivity and rapid recovery characteristics to 100 ppb ozone exposure for 5 min. Especially, it shows the reproducibility of the sensor signal for repeated measurements and the linearity between the ozone concentration and the sensor resistance. The preliminary results clearly demonstrated that the sensor can be successfully applied for the ozone detection of ppb range.

  • PDF